Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probes" wg kryterium: Temat


Tytuł:
Wireless system for radiometric measurements
Autorzy:
Jakowiuk, A.
Pieńkos, P. J.
Kowalska, E.
Filipiak, P.
Świstowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/146860.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiometric probes
radon concentration measurements
wireless communication
Opis:
Wireless system for radiometric measurements contains probes, for gamma radiation measurements and other probes for radon concentration measurements in air and water. The probes have the form of droplet-tight cylinders powered from a local battery. Measuring data collecting unit, based on a portable computer, communicates directly with the probes in a wireless manner using the WiFi communication network, or through the internet using mobile phone GSM network. Serial port wire connection is also possible. The local battery ensures at least 14 days of continuous operation of the probes. For long term measurements, the probes can also be powered from solar panels. Construction and operation of the probes are described. Results of scintillation probes investigation are given. Detection efficiency of the developed probes is comparable with the laboratory probes offered in our country.
Źródło:
Nukleonika; 2012, 57, 4; 637-641
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ustalenie przyczyn nadmiernych przemieszczeń osiowych wirnika silnika
Determination of causes of excessive axial movements of rotor engines
Autorzy:
Walczak, R.
Goleniewski, G.
Jasiński, K.
Korytkowski, A. W.
Powiązania:
https://bibliotekanauki.pl/articles/258065.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
diagnostyka
maszyna
wiroprądowy czujnik drgań
diagnostics
machine
proximity probes
Opis:
W pracy przedstawiono problem nadmiernych drgań wzdłużnych wirnika silnika napędzającego agregat pompowy. Wirnik został uszkodzony w wyniku drgań. W trakcie badań diagnostycznych sprawdzono zamocowanie silnika oraz osiowanie silnika i pompy. Sprawdzono pracę rozsprzęglonego silnika, który bez pompy pracował poprawnie. Po ponownym zesprzęgleniu praca agregatu nie zmieniła się w porównaniu z warunkami początkowmi. W badaniach diagnostycznych wykorzystano czujniki wiroprądowe, które były zamocowane do połówek sprzęgła po stronie silnika i po stronie pompy. Pomiary wykazały, że przyczyną nadmiernych drgań silnika była praca pompy. Ostatecznie okazało się, że pompa została niepoprawnie dobrana do instalacji. Dobrano za dużą pompę, co spowodowało nierówność ciśnień po dwóch stronach łopatek pompy, co z kolei było przyczyną drgań wzdłużnych pompy i wymuszanie drgań osiowych wirnika silnika.
The problem of excessive vibration of pump-engine aggregate was presented in the paper. The operating personnel claimed that a new engine attached to a pump was damaged due to axial excessive vibrations. The engine anchoring and engine and pump alignments were checked. The engine without the pump operated perfectly well. When the engine and pump were clutched the aggregate vibrations did not changed in comparison to the outset conditions. The proximity probes were attached to pump and engine shafts on the both sides of the clutch. The measurement indicated that the pump caused vibrations. Eventually, it turned out that the pump was oversized, and vibration was caused by pressure unevenness.
Źródło:
Problemy Eksploatacji; 2010, 1; 111-120
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use and calibration of 5-hole pressure probes to measurement of airflow velocity
Autorzy:
Ruchała, P.
Grabowska, K.
Małachowski, P.
Santos, L.
Back, D.
Powiązania:
https://bibliotekanauki.pl/articles/245287.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
aerodynamic measurement
turbomachinery
measuring devices
flow direction measurement
multi-hole probes
Opis:
Multi-hole probes are simple and robust device to measurement of flow velocity magnitude and direction in wide range of angles of attack – up to 75°. They become popular as they may be easily use to measurement of unknown flow velocity, while optical methods, like PIV or LDA, require some knowledge about the flow for proper setting of measurement devices. Multi-hole probes are also more lasting in comparison with CTA hot-wire probes, which may be damaged by a dust. A multi-hole probe measures air pressure with one pressure tap on its tip and a few (usually 2, 4, 6 or more) taps on conical or semispherical surface of the probe tip. Based on measured pressures, some non-dimensional pressure coefficients are calculated, which are related to flow velocity direction (i.e. two angles in Cartesian or spherical coordinate system) and magnitude. Finding relations between these parameters is relatively complex, which for years was limiting application of multi-hole probes. The article summarizes methods of multi-hole probes calibration and use, which may be classified as nulling and non-nulling methods or – with other criteria – as global and local methods. The probe, which was presented in the article, was the 5-hole straight probe manufactured by Vectoflow GmbH and calibrated in the stand designed and manufactured at the Institute of Aviation. The local interpolation algorithm has been used for calibration, with some modifications aimed on mitigate of mounting uncertainty, which is related with the non-alignment of flow velocity direction and probe axis Results of calibration showed that the accuracy of presented methodology is satisfactory. The standard measurement uncertainty was assessed for 0.2° for the pitch angle and yaw angle, which is better than accuracy declared by the probe’s manufacturer (1.0°). The measurement uncertainty of the flow velocity is approximately 0.12 m/s, similarly like in manufacturer’s data.
Źródło:
Journal of KONES; 2018, 25, 2; 319-327
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of the delay time of wireless communication of CNC machine tools’ probes and controller
Autorzy:
Jankowski, M.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/220903.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
probes
CNC machine tools
communication delay
measurement speed
Opis:
Touch-trigger probes for CNC milling machines usually use wireless communication in the radio or IR band. Additionally they enable triggering signal filtering in order to avoid false triggers of the probe. These solutions cause a delay in trigger signal transmission from the probe to the machine tool controller. This delay creates an additional pre-travel component, which is directly proportional to the measurement speed and which is the cause of a previously observed but not explained increase of the pre-travel with the increase of the measurement speed. In the paper, a method of testing the delay time of triggering signal is described, an example of delay time testing results is presented and the previous, unexplained results of other researchers are analysed in terms of signal transmission delay.
Źródło:
Metrology and Measurement Systems; 2018, 25, 2; 377-386
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface probes for building materials moisture measurement by reflectometric method
Sondy powierzchniowe do pomiarów wilgotności materiałów budowlanych metodą reflektometryczną
Autorzy:
Jedut, A.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/126528.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
TDR method
surface probes
moisture measurement
metoda TDR
sondy powierzchniowe
pomiary wilgotności
Opis:
The problem of building materials moisture, resulting from their porous structure, has a meaningful value for environmental engineering for the sake of its numerous, negative consequences. After breaking the limited states, the negative aspects both for building users’ health, mechanical, physical and chemical properties of barriers can be observed. Therefore, the essential matter is to provide the possibility of barriers moisture state evaluation. Among the techniques used for building materials moisture measurement, the TDR method application should be underlined for the sake of its simplicity in use and high precision, especially with the use of surface probes. The construction of probes presented in this paper enables non-invasive and accurate moisture measurements, both in laboratory and in situ conditions. The formulas obtained from conducted investigations make possible the evaluation of selected building materials moisture states.
Problem zawilgocenia materiałów budowlanych, wynikający z ich porowatej struktury, ma duże znaczenie dla inżynierii środowiska z uwagi na jego liczne, negatywne następstwa. Przy przekroczeniu stanów dopuszczalnych obserwuje się niekorzystne skutki dla zdrowia użytkowników budynku spowodowane wzrostem liczby szkodliwych mikroorganizmów i grzybów oraz obniżeniem parametrów komfortu cieplnego, a także negatywny wpływ wilgoci na właściwości mechaniczne i fizykochemiczne przegrody. Ważną kwestię stanowi zatem możliwość oszacowania stanu wilgotnościowego materiałów budowlanych. Spośród dostępnych technik pomiarowych dużą precyzją oraz prostotą stosowania wyróżnia się metoda reflektometrii w domenie czasowej (Time Domain Reflectometry), szczególnie z zastosowaniem sond powierzchniowych. Sondy o konstrukcji przedstawionej w tej pracy umożliwiają bezinwazyjne i dokładne pomiary wilgotności zarówno w warunkach laboratoryjnych, jak i w obiektach rzeczywistych. Równania otrzymane na podstawie przeprowadzonych badań mogą posłużyć do oceny stanów wilgotnościowych wybranych materiałów budowlanych.
Źródło:
Proceedings of ECOpole; 2010, 4, 1; 61-66
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studium przypadków - badanie złączy austenitycznych na terminalu LNG
Case study - the study of austenitic joints for LNG terminal
Autorzy:
Śliwowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/107756.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
studium przypadku
badanie ultradźwiękowe
złącza austenityczne
spoiny austenityczne
konwencjonalne głowice ultradźwiękowe echa PE
głowice ultradźwiękowe nadawczo-odbiorcze fal podłużnych TRL
głowice ultradźwiękowe z podwójną matrycą phase-array
nadawczo-odbiorcze PA DMA-TRL
case study
ultrasonic inspection
austenitic welds (austenitic welded joints)
austenitic welds (seams)
conventional ultrasonic pulse echo probes PE
ultrasonic twin probes of longitudinal waves TRL
ultrasonic dual matrix phase-array probes PA DMA-TRL
Opis:
W referacie rozważono, w ramach studium przypadku, zadanie ultradźwiękowego badania doczołowych austenitycznych złączy spawanych na zbiornikach ciekłego gazu terminalu LNG, w zakresie średnic do DN 60 m oraz zakresie grubości 10 ÷ 40 mm. Przedstawiono podstawowe problemy występujące przy ultradźwiękowym badaniu austenitycznych złączy spawanych o dużej grubości ziaren w spoinach. W ramach studium przypadku prześledzono dobór techniki badania - w oparciu o dostępną wiedzę, istniejące dokumenty normatywne i badania na reprezentatywnych próbkach złączy. Zaprezentowano plan badania obwodowych złączy spawanych zbiorników austenitycznych z wykorzystaniem konwencjonalnego ultradźwiękowego systemu badawczego, opartego na technice wielogłowicowej. Omówiony został sposób nastawiania zakresu pomiarowego i czułości badania na reprezentatywnej próbce odniesienia w postaci spoiny austenitycznej z reflektorami referencyjnymi przewidzianymi dla każdej strefy przeszukiwania. Przedstawiono również alternatywne nowoczesne rozwiązanie skanera z dwoma głowicami ultradźwiękowymi z podwójną matrycą phase-array typu PA DMA-TRL, współpracującymi z aparaturą sterującą lokalizacją i akwizycją wyników badania. Omówione zostały zalety nowoczesnej techniki badawczej. Prezentowane studium przypadku jest przykładem sformułowania założeń do przygotowania procedury badania obiektu dla technicznie ważnego i odpowiedzialnego zadania badawczego – ocena zgodności z wymaganiami złączy austenitycznych w zbiornikach magazynowych ciekłego gazu LNG.
In paper, in a frame of case study, the ultrasonic inspection of austenitic girth butt welds in storage tank of LNG terminal for the range of diameter till 60 m and thickness range 10 ÷ 40 mm was studied. There are presented the fundamental problems arise by ultrasonic testing of austenitic coarse grained welds. The examination technique selection based on accessible knowledge, existing standards and tests on representative weld specimen is followed through in a frame of case study. It is presented the scan plan of testing the austenitic girth welds using conventional ultrasonic system, based on the multiprobe scanning. There is presented a range and sensitivity setting on reference block manufactured on the base of representative austenitic weld with reference reflectors dedicated to each area of interest of inspected weld volume. It is also presented the new modern solution of scanner with only two probes. Each of them is dual matrix phase –array probe working in pitch-catch mode and cold symbolic PA DMA-TRL. They are connected with phase-array apparatus controlled localization and acquisition of experimental data. There are discussed advantages such a modern examination technique reached highest level of NDT techniques. The presented case study is an assumption formulation example of examination procedure for technically important and responsible object - like assessment of requirements agreement with technical regulations for the austenitic welds in storage tanks of liquid gas LNG.
Źródło:
Badania Nieniszczące i Diagnostyka; 2016, 1-2; 19-26
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sondy fluorescencyjne typu „light up” do detekcji i obrazowania G-kwadrupleksów in vitro i in vivo. Cz. 1 i 2
Light up fluorescent probes for detection and visualizing the G-quadruplexes in vitro and in vivo. Part 1 and 2
Autorzy:
Baranowski, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/1409732.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
G-kwadrupleks
fluorescencja
ligandy wiążące się do G-kwadrupleksu
sondy fluorescencyjne
obrazowanie komórkowe
detekcja in vitro
G-quadruplex
Fluorescence
G-quadruplex binding ligand
Fluorescent probes
cellular imaging
in vitro detection
Opis:
G-quadruplexes are non-canonical guanosine rich four stranded nucleic acids structures consisting of at least two or more G-tetrads stabilized by an array of Hoogsteen hydrogend bonds and monovalent cations. The distinguishing feature of the G-quadruplexes is their high thermal stability and structural polymorphism in aqueous media. In parallel, a great number of GQ structures have been extensively surveyed ex vivo by means of biophysical techniques such as nuclear magnetic resonance (NMR) spectroscopy, circular dichroism (CD) spectroscopy, and X-ray crystallography. Accumulating evidence suggesting that G-quadruplexes play essential role in a numerous biological processes in vivo, including DNA replication and transcription, RNA translation as well as genomic maintenance. Consequently, G-quadruplexes has attracted attention as therapeutic targets in cancer or hereditary diseases as well as molecular target in cellular biology. Study on G-quadruplexes:ligand interaction by NMR, CD, UV and fluorescence spectroscopy in vitro or in vivo has become an intensive research work area of many groups in recent years. Nowadays, there are available large amount of organic compounds that selectively bind to G-quadruplexes and their photophysical and kinetic properties were comprehensively characterized but only few of them are endowed with fluorescence properties that could be applicable as fluorescent probes in cellular biology or in vitro detection. Interestingly, the group of these fluorescent probes is characterized by a vast structural diverisity resulting from the different way of interaction with G-quadruplexes as well as G-quadruplex polymorphism. This review focuses on the G-quadruplex-selective light up fluorescent probes that have been employed for in vitro detection as well as cellular imaging along with a summary of the key photophysical, biophysical, and biological properties of reported examples.
Źródło:
Wiadomości Chemiczne; 2020, 74, 11-12; 883-901
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sole stilbazoliowe jako sondy fluorescencyjne do monitorowania lokalnej lepkości i pH roztworów
Stilbazolium salts as fluorescence probes for monitoring local viscosity and pH of solutions
Autorzy:
Bajorek, A.
Wrześniewska, I.
Pietrzak, M.
Powiązania:
https://bibliotekanauki.pl/articles/1207619.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
sondy fluorescencyjne
jodki styrylopirydyniowe
jodki styrylochinoliniowe
fluorescent probes
styrylopirydyniowe iodides
iodide styrylochinoliniowe
Opis:
Serię 7. barwników stilbazoliowych, p-podstawionych jodków 2- i 4-styrylochinoliniowych oraz 2- i 4-styrylopirydyniowych otrzymano przez kondensację aldehydu 4-(N,N-dimetyloamino)benzoesowego oraz aldehydu 4-(N,N-dimetyloamino)-1-naftoesowego z jodkami N-podstawionych pikolin i metylochinolin. Wyznaczono właściwości spektroskopowe otrzymanych związków w rozpuszczalnikach znacznie różniących się polarnością, oraz zbadano ich przydatność jako sond fluorescencyjnych do badania lokalnej lepkości i pH roztworów.
A series of p-substituted 2- or 4-styrylquinolinium iodides and 2- or 4- styrylpyridinium iodides were prepared by the condensation of 4-(N,N-dimethylamino)benzaldehyde and 4-(N,N-dimethylamino)-1-naphthaldehyde with N-substituted picolines and methylquinolinium iodides. Spectroscopic properties of the dyes are characterized in organic solvents. These dyes were then tested as fluorescence probes to study the local viscosity and pH of the solutions.
Źródło:
Chemik; 2011, 65, 4; 255-260
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected methods of electronand ion-diagnostics in tokamak scrape-off-layer
Autorzy:
Sadowski, M. J.
Powiązania:
https://bibliotekanauki.pl/articles/146123.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
diagnostics
electrons
ions
fusion products
probes
tokamak
Opis:
This invited paper considers reasons why exact measurements of fast electron and ion losses in tokamaks, and particularly i n a scrape-off-layer and near a divertor region, are necessary in order to master nuclear fusion energy production. Attention is also paid to direct measurements of escaping fusion products from D-D and D-T reactions, and in particular of fast alphas which might be used for plasma heating. The second part describes the generation of so-called runaway and ripple-born electrons which might induce high energy losses and cause severe damages of internal walls in fusion facilities. Advantages and disadvantages of different diagnostic methods applied for studies of such fast electrons are discussed. Particular attention is paid to development of a direct measuring technique based on the Cherenkov effect which might be induced by fast electrons in appropriate radiators. There are presented various versions of Cherenkov-type probes which have been developed by the NCBJ team and applied in different tokamak experiments. The third part is devoted to direct measurements of fast ions (including those produced by the nuclear fusion reactions) which can escape from a high-temperature plasma region. Investigation of fast fusion-produced protons from tokamak discharges is reported. New ion probes, which were developed by the NCBJ team, are also presented. For the fi rst time there is given a detailed description of an ion pinhole camera, which enables irradiation of several nuclear track detectors during a single tokamak discharge, and a miniature Thomson-type mass-spectrometer, which can be used for ion measurements at plasma borders.
Źródło:
Nukleonika; 2015, 60, 2; 199-206
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in MJ plasma focus research at IPPLM
Autorzy:
Scholz, M.
Karpinski, L.
Krauz, V. I.
Kubeš, P.
Paduch, M.
Sadowski, M. J.
Powiązania:
https://bibliotekanauki.pl/articles/147514.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
PF-1000 facility
magnetic probes
interferometry
neutron yield scaling
Opis:
The results of studies of the plasma dynamics and neutron emission on a PF-1000 facility in the stage of pinch formation are presented. The measurements were performed using various modifications of the calibrated magnetic probes, 16 frame interferometry, silver activation counters and photomultiplier tube (PMT) neutron probes. The current measurements at a distance of 40 mm from the axis of the electrodes was measured. This dependence agrees well with the known scaling, Yn similar to I4. The evolution plasma density during pinch formation and a neutron emission were study.
Źródło:
Nukleonika; 2012, 57, 2; 183-188
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probes for fault localization in computer networks
Autorzy:
Traczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/308948.pdf
Data publikacji:
2004
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
fault localization
probes
computer networks
partitions
logic design
Opis:
Fault localization is a process of isolating faults responsible for the observable malfunctioning of the managed system. This paper reviews some existing approaches of this process and improves one of described techniques - the probing. Probes are test transactions that can be actively selected and sent through the network. Suggested innovations include: mixed (passive and active) probing, partitioning used for probe selection, logical detection of probing results, and adaptive, sequential probing.
Źródło:
Journal of Telecommunications and Information Technology; 2004, 3; 23-27
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne aspekty niedopasowania zakresów spektralnych sond pomiarowych do obowiązujących kryteriów oceny zagrożenia nielaserowym promieniowaniem optycznym
Practical aspects of measuring detectors spectral unfitting to obligatory criteria of occupational hazard evaluation arising from non-coherent optical radiation
Autorzy:
Pawlak, A.
Wolska, A.
Powiązania:
https://bibliotekanauki.pl/articles/158968.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
promieniowanie optyczne
pomiary radiometryczne
pomiary spektroradiometryczne
niedopasowanie spektralne sond pomiarowych
optical radiation
radiometric measurements
spectroradiometer measurements
spectral mismatch of measurement probes
Opis:
W artykule przedstawiono przykłady niedopasowania widmowego metody radiometrycznej stosowanej do wyznaczania poziomów ekspozycji na stanowiskach pracy zgodnie z obowiązującymi kryteriami oceny zagrożenia promieniowaniem optycznym w środowisku pracy. Na przykładzie badań porównawczych wykonanych spektroradiometrem OL 750 oraz radiometrem ILT 1400 z zestawem sond pomiarowych dedykowanych wybranym zagrożeniom promieniowaniem optycznym, przeanalizowano potencjalne różnice wskazań wynikające z niedopasowania widmowego stosowanych sond pomiarowych. Wykazano, że niedopasowanie widmowe sond pomiarowych przy wyznaczaniu poziomu ekspozycji dla zagrożenia fotochemicznego oczu i skóry promieniowaniem UV oraz termicznego siatkówki oka promieniowaniem VIS + IR-A w nieznacznym stopniu wpływa na wynik pomiaru. Natomiast w przypadku wyznaczania poziomu ekspozycji na promieniowanie UV-A stwierdzono niedoszacowanie wyników pomiaru wynoszące ok. 30%, które należałoby uwzględniać przy wyznaczaniu poziomu ekspozycji oczu na promieniowanie UV-A.
The article presents examples of spectral unfitting of a radiometric measurement method, which is used for determining of the exposure level on workstations according to obligatory criteria of the occupational hazard evaluation arising from an optical radiation. The comparative measurements were carried out using spectroradiometric and radiometric methods and the potential percentage differences of measurement results were obtained. The spectral unfitting of detectors used for actinic UV measurements and thermal retina hazard form range VIS+IR-A showed small difference of measured exposure levels had small influence on hazard evaluation. However, the spectral unfitting of UV-A irradiance resulted in 30% underestimation of the radiometric method which underestimation should be taken into account during the exposure level determination.
Źródło:
Prace Instytutu Elektrotechniki; 2015, 268; 122-140
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary ciśnienia metanu w pokładach węgla kamiennego w GZW mierzone metodą bezpośrednią
Methane pressure in coal seams of the USCB measured by direct method
Autorzy:
Wierzbicki, M.
Skoczylas, N.
Kudasik, M.
Powiązania:
https://bibliotekanauki.pl/articles/166477.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
ciśnienie złożowe metanu
sonda ciśnieniowa
metan
wyrzuty metanu i skał
coal seam methane pressure
pressure probes
methane
methane and rock outbursts
Opis:
Ciśnienie złożowe metanu w porach i szczelinach pokładów węgla kamiennego jest podstawowym czynnikiem determinującym stan zagrożeń zjawiskami gazodynamicznymi. Ze względu na problemy metrologiczne, jego pomiary wykonywane są stosunkowo rzadko. Autorzy opracowania skonstruowali sondy ciśnieniowe oraz wykonali liczną serię pomiarów ciśnienia złożowego w kopalniach GZW. Zmierzone ciśnienia złożowe mieściły się w przedziale 1,2÷12,3 bar. Także na krótkich otworach badawczych o długości 2 metry zarejestrowano ciśnienia zbliżone do 10 bar. Wyniki pomiarów ciśnienia złożowego potwierdziły, że pomiędzy poszczególnymi kopalniami występują istotne różnice średnich wartości mierzonych ciśnień.
The coal seam methane pressure in pores and cracks of coal beds is a basic factor determining the level of risk of gaso-geodynamic phenomena. Due to some metrological problems, this parameter is not measured frequently. The authors of the paper constructed their own pressure probes and performed a series of multiple measurements of the coal seam methane pressure in the mines of the Upper Silesian Coal Basin. The measured values fell within the range of 1.2-12.3 bar. The values of ca. 10 bar were also registered in the shortest (2 m) test boreholes. At this point, it needs to be stated that there are considerable differences between mean pressure values measured in particular mining facilities.
Źródło:
Przegląd Górniczy; 2015, 71, 7; 21-25
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pochodne kumaryny jako molekularne sensory fluorescencyjne stosowane do monitorowania procesów fotopolimeryzacji
Coumarin derivatives as molecular fluorescence probes applied for monitoring photopolymerization processes
Autorzy:
Pudo, A.
Kamińska, I.
Ortyl, J.
Powiązania:
https://bibliotekanauki.pl/articles/134684.pdf
Data publikacji:
2015
Wydawca:
ADVSEO
Tematy:
pochodne kumaryny
fotopolimeryzacja
sensory fluorescencyjne
FPT
fluorescence probes
cationic photopolymerization
radical photopolymerization
coumarin derivatives
polymerization processes monitoring
Opis:
This paper presents research on the use of coumarin derivatives as fluorescent molecular probes for monitoring cationic and free radical photopolymerization processes, using for that purpose modern FPT method (Fluorescence Probe Technology). Literature review on the main trends of applications and spectroscopic properties of coumarin derivatives was described. In the following part of publication, relations between change of fluorescence characteristic and physicochemical changes occurring in the polymerizable composition, (both microviscosity and polarity) were explained. This article also presented the basic methodology of studies on the control of the photopolymerization reaction on-line and off-line, using fluorescence spectroscopy and parameters such as: fluorescence intensity ratio R, number of progress of the reaction β and molecular probe sensitivity S.
Źródło:
Technical Issues; 2015, 1; 47-53
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pochodne kumaryny do roli molekularnych sensorów fluorescencyjnych do zastosowań w naukach life science
Coumarin derivatives for the role of molecular fluorescent sensors for the application in life science
Autorzy:
Czarna, M.
Kamińska, I.
Ortyl, J.
Powiązania:
https://bibliotekanauki.pl/articles/134827.pdf
Data publikacji:
2015
Wydawca:
ADVSEO
Tematy:
kumaryna
sensory molekularne
fluoroscencja
coumarin
fluorescence
molecular sensor
molecular probes
fluorophores
Opis:
Fluorescent spectroscopy is an important method in life science which has recently gained popularity. Fluorescent spectroscopy is widely used for example by the researches in the variety of biological structures, intercellular interactions, various kinds of biomolecules and also for understanding of the biochemical processes which take place inside the living organisms. For this purpose, an application of fluorescent sensors and searching for more efficient and more sensitive fluorophore for illustrating, labelling and detection, have become a developing trend in biochemistry, medicine, biology and also in many other chemistry researches. Nowadays, issues which are connected to fluorescence are mainly applied to the newest achievements in the field of fluorescent methods and measurement techniques and also to the development and applications of fluorescent probes, what is closely showed up in this article.
Źródło:
Technical Issues; 2015, 4; 3-10
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies