Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probe calibration" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
A 2-Port, Space-Saving, Maintenance-Friendly Pneumatic Probe for Velocity Measurements
Autorzy:
Olczyk, A.
Magiera, R.
Kabalyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/221299.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pneumatic probes
probe calibration
uncertainty of measurements
velocity measurements
Opis:
This paper presents the concept, design and experimental results of tests, in laboratory conditions, of a 2-port, space-saving pneumatic probe. The main features of the probe are a result of restrictions imposed by the functioning environment: a limited space for probe installation, the possibility of processing only two output signals and requirements for simplicity and reliability of the probe. A cylindrical shape of the probe tip is proposed as a general concept, similar to the classic, cylindrical, 3-port probe. The main difference arises in using only two pressure signals: one from the overpressure zone on the front side of the cylinder and another, from the underpressure zone on the back side. After performing an appropriate calibration procedure, it is possible to measure the flow velocity and correct the pressure difference obtained by means of a velocity coefficient kv. This paper also presents an analysis of the kv coefficient uncertainty to evaluate the quality of measurements.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 171-185
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the influence of calibration sphere parameters on the results of articulating probe head qualification
Autorzy:
Gruza, Maciej
Gąska, Adam
Gąska, Piotr
Harmatys, Wiktor
Sładek, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/103260.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
calibration
accuracy
przegubowa głowica sondy
kalibrowanie
precyzja
Opis:
The qualification of probe heads before the measurements performed with their usage is now a standard procedure. It is used for correction of probe head’s and measuring tip systematic errors. The calibration sphere, which is used for this process, should have adequately small form errors. However, it is not always possible to use a highly accurate spheres and it is a common practice to use a sphere that was provided by the manufacturer of the CMM for a long time. This is why, the authors have tried to answer the question about the impact of the calibration sphere inaccuracies on the results of probe head qualification process.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 2; 252-259
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja sond psychrometrycznych
Psychometric probes calibration
Autorzy:
Guz, Ł.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/960164.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sonda psychrometryczna
potencjał wody
wilgotność względna
kalibracja
psychrometric probe
water potential
relative humidity
calibration
Opis:
Potencjał wody jest wyznacznikiem zdolności przemieszczania się wody w materiałach porowatych, jakimi są materiały budowlane. Gdy potencjał wody jest bliski zeru, para wodna zawarta w przegrodzie jest praktycznie w stanie nasycenia i istnieje ryzyko wykroplenia się wody wewnątrz konstrukcji. Zmierzony przez sondę psychrometryczną potencjał wody może być w prosty sposób przeliczony na wilgotność względną materiału porowatego. Aby możliwy był pomiar potencjału wody, należy każdą sondę skalibrować, tzn. określić zależność pomiędzy potencjałem wody i napięciem generowanym na termozłączu. W wyniku zapisu zmieniającego się napięcia na sondzie otrzymuje się krzywą psychrometryczną, której kształt odzwierciedla fizyczne zjawiska przemian fazowych wody zachodzących podczas pomiarów. Przy wilgotności względnej poniżej ok. 92% kształt krzywej psychrometrycznej jednak nie pozwala na jednoznaczne określenie etapu parowania wykroplonej na termozłączu wody, gdyż niewielka ilość wykroplonej wody, odparowując, nie powoduje ustabilizowania się temperatury termozłącza w punkcie rosy. Zmierzone wówczas napięcie generowane wskutek zjawiska Seebecka nie będzie dokładnie odzwierciedlać wilgotności względnej materiału porowatego, dlatego metody wykorzystujące do analizy napięcie na sondzie są wtedy obarczone pewnym błędem. Metoda analizy, wykorzystująca powierzchnię pola pod krzywą psychrometryczną, która jest proporcjonalna do czasu chłodzenia termozłącza, umożliwia w tych warunkach pomiar. Dzięki krzywej kalibracyjnej wiążącej powierzchnię pod krzywą psychrometryczną z potencjałem wody (lub też z wilgotnością względną) można określić stan wilgotności, pomimo iż kształt krzywej psychrometrycznej na to nie pozwala. Powyższa metoda może również obniżyć dolną granicę pomiarową wilgotności względnej dla sond psychrometrycznych.
Water potential determines the ability of water migration in porous materials like buildings materials. When water potential is close to zero, water vapor contained in buildings materials is almost saturated and the risk of water vapor condensation in the wall construction appears. Water potential measured with psychrometric probe can be easily recalculated into moisture of the porous material. To enable the water potential measurements, each probe must be previously calibrated which means finding a correlation between water potential and voltage generated on thermocouple. As a result of voltage changes, the trace on thermocouple junction is forming calibration curve which shape reflects the physical phenomena of water phase transition during measurement. However at the low value of water potential, below 92%, the shape of psychrometric curve does not allow to determine the evaporation phase of condensed water on thermocouple. Evaporation of a small amount of water does not cause the temperature stabilization of the thermocouple at dew point temperature. Measured voltage generated through Seebeck effect would not precisely represent the relative moisture of the porous material, that is why the methods using this voltage on probe will be embarked with some error. In these circumstances very helpful can be the analysis method used field under psychrometric probe, that in some range is proportional to thermocouple cooling time. With calibration curve correlating field under psychrometric curve to water potential (or with relative humidity) it can be determined the water potential even when shape of psychrometric curve not allow to this. This method allows to decrease the lower boundary of measurements with psychrometric probe.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 133-138
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in the development of the semi-empirical calibration of neutron probes based on Monte Carlo modeling
Autorzy:
Woźnicka, Urszula
Powiązania:
https://bibliotekanauki.pl/articles/1841776.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
neutron well logging
calibration of the borehole neutron probe
general neutron parameter of neutron transport
Opis:
The method of the semi-empirical calibration of a neutron well logging probe was developed by Jan Andrzej Czubek on the concept of the general neutron parameter (GNP) and tested positively at the neutron calibration station in Zielona Góra, Poland. The neutron probe responses in a wide range of neutron parameters (and thus lithology, porosity and saturation) were also computed using the Monte Carlo method. The obtained simulation results made it possible to determine the calibration curves using the Czubek concept in a wider range than by means of the original method. The very good compatibility of both methods confirms the applicability of the GNP as well as the Monte Carlo numerical experiments, which allow for a significant extension of the semi-empirical calibration in complex well geometries taking into account e.g., casing or invaded zones.
Źródło:
Geology, Geophysics and Environment; 2020, 46, 3; 251-254
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of errors in on-wafer measurements due to multimode propagation in CB-CPW
Autorzy:
Lewandowski, A.
Wiatr, W.
Powiązania:
https://bibliotekanauki.pl/articles/307779.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
on-wafer measurements
multimode propagation
error analysis
conductor-backed coplanar waveguide (CB-CPW)
microstrip-like mode
numerical electromagnetic analysis
on-wafer probe
calibration
de-embedding
monolithic microwave integrated circuit (MMIC)
Opis:
We study for the first time errors in on-wafer scattering parameter measurements caused by the parasitic microstrip-like mode propagation in conductor-backed coplanar waveguide (CB-CPW). We determine upper bound for these errors for typical CPW devices such as a matched load, an open circuit, and a transmission line section. To this end, we develop an electromagnetic-simulations-based multimode three-port model for the transition between an air-coplanar probe and the CB-CPW. Subsequently, we apply this model to examine errors in the device S parameters de-embedded from measurements affected by the parasitic MSL mode. Our analysis demonstrates that the multimode propagation in CB-CPW may significantly deteriorate the S-parameters measured on wafer.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 2; 16-22
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies