Comparison of the results for calculation of vortex currents after sudden expansion of the pipe with different diameters
Autorzy:
Kholboev, B. M.
Navruzov, D. P.
Asrakulova, D. S.
Engalicheva, N. R.
Turemuratova, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/2174200.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
fluktuacja prędkości
prąd wirowy
anizotropia turbulencji
two-fluid turbulence model
sudden expansion
velocity fluctuation
intensity of fluctuations
gas resistance
quasi-periodic regime
Opis:
In this work, a numerical study of a sharply expanding highly swirling flow is carried out using v2-f models based on the Comsol Multiphysics 5.6 software package and a two-fluid turbulence model. The results obtained are compared with known experimental data with different pipe diameters. The purpose of this work is to test the ability of models to describe anisotropic turbulence. It is shown that the two-fluid model is more suitable for studying such flows.
Źródło:
International Journal of Applied Mechanics and Engineering; 2022, 27, 2; 115--123
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Delimitacja prądów strumieniowych nad półkulą północną na podstawie reanaliz ERA5 o wysokiej rozdzielczości przestrzennej
The delimitation of jet streams in the Northern Hemisphere on the basis of high-resolution ERA5 Reanalysis
Autorzy:
Degirmendžić, Jan
Powiązania:
https://bibliotekanauki.pl/articles/2175592.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwa Geofizyczne
Tematy:
delimitacja
prąd strumieniowy
jet streak
matryca sferyczna
półkula północna
orografia
delimitation
jet stream
spherical cap matrix
Northern Hemisphere
orography
Opis:
Celem analizy jest delimitacja górnotroposferycznych prądów strumieniowych w polach wiatru o wysokiej rozdzielczości przestrzennej. Wykorzystano 6-godzinne pola wiatru (U, V) na powierzchni 300 hPa o rozdzielczości 0.25°×0.25° z bazy ERA5. Analiza dotyczy zakresu 0°-90°N, sezonu zimowego oraz 40-lecia 1981-2020. Procedura polega na wyznaczeniu pozycji tzw. jet streaków, czyli regionów o najwyższym potencjale cyklogenetycznym osadzonych w osi prądu strumieniowego. Określono pozycję geograficzną gridów centralnych jet streaków oraz prędkość wiatru w tych gridach. Punkt centralny jet streak (JSC) zdefiniowano jako lokalne maksimum prędkości wiatru. Identyfikując JSC zastosowano matrycę sferyczną o stałym promieniu R=500 km. Nie wykorzystano matrycy lat×lon, ponieważ zmniejsza ona swoje rozmiary ku biegunowi, co powoduje zwiększenie udziału small-scale wind features w ogólnej liczbie wykrytych jet streaków w szerokościach okołobiegunowych. Wykryto 311 712 jet streaków. Wyniki analizy przedstawiono na mapach częstości jet streaków oraz średniej prędkości wiatru w JSC. Makroskalowa struktura prądów strumieniowych tworzy układ spirali ze strefą wejścia nad Afryką i strefą wyjścia nad północną Europą. Wśród podzwrotnikowych prądów strumieniowych można wyróżnić: NAAJ (North Africa-Asian Jet) oraz EAJ (East Asian Jet). Strefą graniczną jest obszar niezbyt silnych jet streaków nad Himalajami. Te strumienie są wąskie i mają równoleżnikowy przebieg. Prądy strumieniowe nad wschodnim Pacyfikiem (wschodnia część NPJ) oraz nad Atlantykiem (NAJ) cechują się większą dyspersją szerokości geograficznej, co przejawia się poszerzeniem strugi na mapach klimatycznych oraz mają orientację WSW - ENE. Nad kontynentami widać wyraźny podział na dwa strumienie: polarny (w wyższych szerokościach geograficznych) oraz podzwrotnikowy. Strumień polarny nad środkową i północną Eurazją oraz strumień podzwrotnikowy nad Ameryką Północną mają epizodyczny charakter. Odnoga widoczna poniżej 35°N nad Ameryką zanika w polu prędkości. Prąd strumieniowy nad zachodnim Pacyfikiem – EAJ (lub zachodnia część NPJ) jest najsilniejszy spośród wszystkich makroskalowych struktur na półkuli północnej. Zidentyfikowano obszary górskie, które w wyniku interakcji z hemisferyczym prądem strumieniowym przyczyniają się do formowania układów jet streak. Przedstawiona metoda pozwala na precyzyjną identyfikację stref prądów strumieniowych o największym potencjale cyklogenetycznym.
The aim of this research is an attempt at delimiting the upper tropospheric jet streams based on high resolution (0.25°×0.25°) wind fields from ERA5. The procedure is intended to position the jet streaks (JS), i.e. regions cyclogenetically active, embedded within a jet stream. The geographic coordinates of JS-central grid (JSC) and also wind speed in that grid are specified. The analysis: extends for the winter seasons of 1981-2020, is applied to the 300-hPa level and covers the Northern Hemisphere. Jet streak center (JSC) is defined as a local wind maximum. It meets the following criteria: 1. wind speed in JSC ≥ 50 ms-1, 2. wind speed at every other grid, situated no further then 500 km from the JSC ≤ wind speed at JSC. The spherical cap matrix with constant radius equal to 500 km was used for the JSC detection. The lat×lon matrices are not applicable because their dimension decreases with increasing latitude - therefore they have an ability to detect an excessive number of small-scale wind features in high latitudes. It is an undesirable property because smaller than meso-alfa wind features cannot be classified as jet streaks. JSC points were identified on 6-hourly maps. A total number of 311 712 jet streak centers were inventoried. The results of the analysis are presented on the JSC frequency map and average JSC wind speed map. The local impact of orography was also identified on the JSC frequency maps. Macro-structure of jet streams reveals spiral-like shape with entrance region over Africa and exit region over the northern Europe. NAAJ (North Africa-Asian Jet) and EAJ (East Asian Jet) represent subtropical jet stream. Separation zone is formed from weakly active jet streaks over Himalaya. NAAJ and EAJ are relatively narrow and zonally oriented. Variability in jet stream latitude is higher over the eastern Pacific (eastern part of NPJ) and Atlantic (NAJ), which is manifested as a widening of the jet stream flow. In these two geographic regions the jet flow is WSW - ENE oriented. There is a clear division into two streams over the continents: polar in higher latitudes and subtropical. PFJ over the middle and northern Europe and STJ branch over the North America are episodic in nature. The last one, visible below 35°N in JSC frequency field, vanishes in JSC wind speed field. The jet stream over the western Pacific (EAJ / the western part of NPJ) is the strongest of all macro-scale structures in the Northern Hemisphere. Mountain areas that contribute to the formation of jet streaks by interaction with the hemispheric jet stream have been identified. These areas are as follows: Zagros Mountains, Himalayas, mountains of north-eastern Burma, Sayan and Altai Mountains, Scandinavian Mountains, Alps, Pyrenees, mountains of Scotland, Iceland and western Ireland, Japanese Alps, Kyushu Mountains, Chugach Mountains (Alaska), Coast Mountains of Canada, Cascade Range, Sierra Nevada, Sierra Madre Occidental, Appalachian Mountains (Blue Ridge Mountains, Allegheny Plateau, Adirondack Mountains) and the ice cap of southern tip of Greenland. This study presents a novel approach that enables the accurate detection of the jet streaks. It will be used in future research focusing on the contemporary changes in the position and activity of the upper tropospheric jet streams.
Źródło:
Przegląd Geofizyczny; 2022, 3-4; 73--97
0033-2135
Pojawia się w:
Przegląd Geofizyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of conditions for loss of bearing capacity of underground ammonia pipelines based on the monitoring data and flexible search algorithms
Autorzy:
Mysiuk, R.V.
Yuzevych, V.M.
Yasinskyi, M.F.
Kniaz, S.V.
Duriagina, Z.A.
Kulyk, V.V.
Powiązania:
https://bibliotekanauki.pl/articles/24200550.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
underground ammonia pipeline
pump station
thermal background
corrosion current
data processing
cloud computing
podziemny rurociąg amoniaku
stacja pomp
tło termiczne
prąd korozyjny
przetwarzanie danych
chmura obliczeniowa
Opis:
Purpose: The study aims to diagnose the corrosion current density in the coating defect on the outer surface of the ammonia pipe depending on the distance to the pumping station, taking into account the interaction of media at the soil-steel interface and using modern graphical data visualization technologies and approaches to model such a system. Design/methodology/approach: The use of an automated system for monitoring defects in underground metallic components of structures, in particular in ammonia pipelines, is proposed. The use of the information processing approach opens additional opportunities in solving the problem of defect detection. Temperature and pressure indicators in the pipeline play an important role because these parameters must be taken into account in the ammonia pipeline for safe transportation. The analysis of diagnostic signs on the outer surface of the underground metallic ammonia pipeline is carried out taking into account temperature changes and corrosion currents. The parameters and relations of the mathematical model for the description of the influence of thermal processes and mechanical loading in the vicinity of pumping stations on the corresponding corrosion currents in the metal of the ammonia pipeline are offered. Findings: The paper evaluates the corrosion current density in the coating defect on the metal surface depending on the distance to the pumping station and the relationship between the corrosion current density and the characteristics of the temperature field at a distance L = 0…20 km from the pumping station. The relative density of corrosion current is also compared with the energy characteristics of the surface layers at a distance L = 0…20 km from the pumping station. An information system using cloud technologies for data processing and visualization has been developed, which simplifies the process of data analysis regarding corrosion currents on the metal surface of an ammonia pipeline. Research limitations/implications: The study was conducted for the section from the pumping station to the pipeline directly on a relatively small data set. Practical implications: The use of client-server architecture has become very popular, thanks to which monitoring can be carried out in any corner of the planet, using Internet data transmission protocols. At the same time, cloud technologies allow you to deploy such software on remote physical computers. The use of the Amazon Web Service cloud environment as a common tool for working with data and the ability to use ready-made extensions is proposed. Also, this cloud technology simplifies the procedure of public and secure access to the collected information for further analysis. Originality/value: Use of cloud environments and databases to monitor ammonia pipeline defects for correct resource assessment.
Źródło:
Archives of Materials Science and Engineering; 2022, 115, 1; 13--20
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka on-line izolatorów przepustowych typu OPI w transformatorach WN
On-line diagnostics of OPI bushings in HV transformers
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2146333.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
izolator przepustowy
tgδ
współczynnik strat dielektrycznych
prąd upływu
transformer
bushing
dielectric loss factor
leakage current
Opis:
Parametrem diagnostycznym izolatorów przepustowych stosowanym standardowo on-line jest pomiar tg między punktem pomiarowym P i kołnierzem K. Wykazano, że tg nie informuje w sposób dostateczny o stanie technicznym izolatora przepustowego. Polecanym parametrem diagnostycznym on-line izolatora jest prąd upływu mierzony w obwodzie rezystancji włączonej między punkty P-K. Korzystne jest sumowanie sygnałów prądowych z izolatorów trzech faz. Sumowanie należy realizować na transformatorku (rys. 9). Pomiar prądu sumarycznego 0 jest prosty w realizacji i wolny od zakłóceń.
The standard diagnostic parameter HV bushings used on-line is the measurement of tgδ between the measuring point P and the flange K. It has been shown that tgδ does not sufficiently inform about the technical condition of the bushing. The recommended on-line diagnostic parameter of the insulator is the leakage current I measured in the circuit of resistance connected between points P-K. It is advantageous to sum the current signals from the insulators of the three phases. Adding up should be done on a transformer (Fig. 9). Measurement of the summary current 0 is simple to implement and free from interferences.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 35--40
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda szacowania natężenia prądu korozyjnego na podstawie ugięcia elementów żelbetowych
Method of estimation of corrosion current based on deflection of reinforced concrete elements
Autorzy:
Recha, Faustyn
Powiązania:
https://bibliotekanauki.pl/articles/38173613.pdf
Data publikacji:
2022
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
korozja stali zbrojeniowej
ugięcie elementów żelbetowych
prąd korozyjny
corrosion of reinforcing steel
deflection of reinforced concrete element
corrosion current
Opis:
W pracy podjęto problematykę ugięcia elementów żelbetowych, podlegających wpływom korozji zbrojenia. Praca ma charakter w pełni teoretyczny. Skupiono się na wyprowadzeniu zależności, wiążącej gęstość natężenia prądu korozyjnego z krzywizną ugięcia. W zamyśle przedstawionej metody jest to nowy element, umożliwiający wstępne oszacowanie gęstości prądu korozyjnego w oparciu o bezinwazyjne pomiary ugięć konstrukcji.
The study takes into account the problem of deflection of reinforced concrete elements subject to the influence of reinforcement corrosion. The work is fully theoretical. The focus was on deriving the dependence linking the corrosion current density with the deflection curvature. In the concept of the presented method, it is a new element that enables preliminary estimation of the corrosion current density based on non-invasive measurements of structure deflections.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2022, 14; 57-64
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Napięcia i prądy łożyskowe w maszynach elektrycznych
Bearing voltages and currents in electrical machines
Autorzy:
Jarek, Tomasz
Berhausen, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/2142552.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
napięcie łożyskowe
prąd łożyskowy
electrical machines
bearing voltage
bearing current
Opis:
W artykule przedstawiono podstawowe informacje dotyczące zjawiska napięć i prądów łożyskowych w maszynach elektrycznych. Omówiono podstawowe zagadnienia dotyczące przyczyn występowania zjawisk zarówno w przypadku zasilania maszyny bezpośrednio z sieci jak i przy zasilaniu z przekształtników energoelektronicznych. Zaprezentowano również nowe metody ograniczania napięć łożyskowych bazujące na dodatkowym uzwojeniu pomocniczym nawiniętym wokół jarzma stojana oraz na uzwojeniu ekranującym umieszczonym wewnątrz klinów żłobkowych stojana.
The article presents basic information on the phenomenon of bearing voltages and currents in electrical machines. The basic issues concerning the causes of the described phenomena were discussed, both in the case of powering the machine directly from the AC grid as well as in the case of powering from power electronic converters. New methods of limiting bearing voltages were also presented: based on an additional auxiliary winding wound around the stator yoke and on a shielding winding located inside the stator slot wedges.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 169--172
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems related to the correct determination of switching power losses in high-speed SiC MOSFET power modules
Autorzy:
Zięba, Dawid
Rąbkowski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2173649.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
SiC MOSFET
power modules
channel current
switching losses
time alignment
moduł mocy
prąd kanału
straty przełączania
wyrównanie czasu
Opis:
High-speed switching capabilities of SiC MOSFET power modules allow building high power converters working with elevated switching frequencies offering high efficiencies and high power densities. As the switching processes get increasingly rapid, the parasitic capacitances and inductances appearing in SiC MOSFET power modules affect switching transients more and more significantly. Even relatively small parasitic capacitances can cause a significant capacitive current flow through the SiC MOSFET power module. As the capacitive current component in the drain current during the turn-off process is significant, a commonly used metod of determining the switching power losses based on the product of instantaneous values of drain-source voltage and drain current may lead to a severe error. Another problem is that charged parasitic capacitances discharge through the MOSFET resistive channel during the turn-on process. As this happens in the internal structure, that current is not visible on the MOSFET terminals. Fast switching processes are challenging to measure accurately due to the imperfections of measurement probes, like their output signals delay mismatch. This paper describes various problems connected with the correct determination of switching power losses in high-speed SiC MOSFET power modules and proposes solutions to these problems. A method of achieving a correct time alignment of waveforms collected by voltage and current probes has been shown and verified experimentally. In order to estimate SiC MOSFET channel current during the fast turn-off process, a method based on the estimation of nonlinear parasitic capacitances current has also been proposed and verified experimentally.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140695
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review and comparison of methods for limiting leakage currents in single-phase transformerless PV inverter topologies
Autorzy:
Kołodziejski, Wojciech
Jasielski, Jacek
Kuta, Stanisław W.
Szerszeń, Grzegorz
Machowski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/29521110.pdf
Data publikacji:
2022
Wydawca:
Akademia Tarnowska
Tematy:
Differential Mode (DM) voltage
Common Mode (CM) voltage
grid-tied inverter
leakage current
parasitic capacity
photovoltaic (PV) systems
transformerless inverter
napięcie trybu różnicowego (DM).
napięcie trybu wspólnego (CM).
falownik podłączony do sieci
prąd upływowy
pojemność pasożytnicza
systemy fotowoltaiczne (PV).
falownik beztransformatorowy
Opis:
Transformerless inverters are widely used in different photovoltaic nonisolated ac module applications, mainly in grid-tied photovoltaic (PV) generation systems, due to the benefits of achieving high efficiency over a wide load range, and low cost. Various transformerless inverter topologies have been proposed to meet the safety requirement of low ground leakage currents, such as specified in the VDE-4105 standard and low-output ac-current distortion. Topology modifications of transformerless full bridge inverters are designed to balance and maintain a constant common mode output voltage, thereby eliminating or reducing leakage currents. This article reviews and compares the different methods for limiting leakage currents in known topologies of the full-bridge transformerless inverters, such as: H4, H5, H6, HERIC, and their improvements. The main topologies and strategies used to reduce the leakage current in transformerless schemes are summarized, highlighting advantages and disadvantages and establishing points of comparison with similar topologies. To compare the properties of different medium to high power inverters, PV inverter topologies were implemented using IGBTs and tested with the same components, same simulation parameters in PSPICE to evaluate their performance in terms of energy efficiency and leakage current characteristics. The detailed power stage operating principles, extended PWM modulator, and integrated universal gate driver with galvanic isolation in the transmission path of control signal for all IGBTs of the inverter, as well isolated and floating bias power supply for gate drivers are described.
Źródło:
Science, Technology and Innovation; 2022, 16, 3-4; 1-19
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwarcie awaryjne transformatora
Emergency short-circuit of the transformer
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2135014.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
zwarcie symetryczne
zwarcie awaryjne
prąd udarowy
transformer
symmetrical short-circuit
emergency short-circuit
surge current
Opis:
Jedną z prób przewidzianą w programie badań pełnych transformatorów nowych jest próba zwarcia. Sposób przeprowadzenia tej próby jest opisany w normie PN-EN 60076-5. W eksploatacji transformatorów, które pracują w sieci elektroenergetycznej, zdarzają się także zwarcia przypadkowe. Przykładem jest transformator 16 MVA, 110/20kV z wyjściem kablowym. Kabel został uszkodzony. Powstało zwarcie dwufazowe. Transformator uległ awarii. Bazując na tym przykładzie i wykorzystując schematy zastępcze, obliczono prąd udarowy przy zwarciu symetrycznym i prąd udarowy przy zwarciu dwufazowym. Oceniono przepięcia indukowane przy wyłączaniu prądu zwarcia. Wskazano przyczynę awarii transformatora.
One of the tests included in the test program for complete new transformers is the short-circuit test. The method of carrying out this test is described in the PN-EN 60076-5 standard. In the operation of transformers that operate in the power grid, accidental short-circuits also occur. An example is a 16 MVA, 110 / 20kV transformer with cable outlet. The cable has been damaged. A two-phase short circuit has arisen. The transformer has failed. Based on this example and using equivalent diagrams, the impulse current for symmetrical shortcircuit and the impulse current for two-phase short-circuit were calculated. The induced overvoltage when switching off the short-circuit current was assessed. The cause of the transformer failure is indicated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 11--19
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bipolar pulsed radiofrequency neuromodulation of median nerve for treatment of carpal tunnel syndrome – a preliminary study
Neuromodulacja bipolarna nerwu pośrodkowego za pomocą pulsacyjnego prądu o częstotliwości radiowej w leczeniu zespołu cieśni nadgarstka – doniesienie wstępne
Autorzy:
Krzywda, Adam
Wypych-Ślusarska, Agata
Krupa-Kotara, Karolina
Oleksiuk, Klaudia
Głogowska-Ligus, Joanna
Skrzypek, Michał
Słowiński, Jerzy L.
Powiązania:
https://bibliotekanauki.pl/articles/1806833.pdf
Data publikacji:
2021-10-27
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
bipolar neuromodulation
carpal tunnel syndrome
median nerve
pulsed radiofrequency
neuromodulacja bipolarna
zespół cieśni nadgarstka
nerw pośrodkowy
prąd pulsacyjny o częstotliwości radiowej
Opis:
INTRODUCTION: The results of direct surgical release of the median nerve in patients with carpal tunnel syndrome are frequently far from being satisfactory. Aim of the presented study is to assess the early results of bipolar pulsed radiofrequency (PRF) neuromodulation of the median nerve (MN) for treatment of carpal tunnel syndrome (CTS). MATERIAL AND METHODS: Fifteen adult patients with CTS (10 women and 5 men, mean age 58.5 years) were treated. The bipolar technique of neuromodulation was applied, with confirmation of the correct electrode position by neurophysiological examination. The study protocol included the Boston Carpal Tunnel Questionnaire (BCTQ), Numerical Rating Scale (NRS) for pain assessment and tip pinch strength assessment performed before neuromodulation as well as 4 and 12 weeks after treatment. Moreover, the sensory nerve conduction velocity (SNCV) was assessed before and 12 weeks after the intervention. RESULTS: A significant improvement in symptom severity (33.53 ± 8.25 at the baseline vs. 18.33 ± 11.06 and 25.67 ± 12.39 at 4 and 12 weeks) and functional status (21.0 ± 5.79 vs. 12.07 ± 7.20 and 17.73 ± 9.09) BCTQ subscores, as well as tip pinch strength (3.39 ± 1.68 vs. 5.86 ± 1.98 and 4.93 ± 2.22) were observed. A reduction in pain and improvement in SNCV were also found, but did not reach statistical significance. CONCLUSIONS: Bipolar PRF neuromodulation of MN is a promising therapeutic tool for patients with CTS and could potentially be an alternative to direct surgical release of MN. A longer follow-up period is required to assess the longevity of clinical improvement after the treatment.
WSTĘP: Wyniki chirurgicznego odbarczenia nerwu pośrodkowego u części chorych z zespołem cieśni nadgarstka są niezadowalające. Celem pracy jest ocena wczesnych wyników leczenia zespołu cieśni nadgarstka (carpal tunnel syn-drome – CTS) za pomocą bipolarnej neuromodulacji nerwu pośrodkowego (median nerve – MN) z użyciem prądu o częstotliwości radiowej w trybie pulsacyjnym (pulsed radiofrequency – PRF). MATERIAŁ I METODY: Leczeniu poddano 15 dorosłych pacjentów z CTS (10 kobiet i 5 mężczyzn, średni wiek 58,5 roku). Zastosowano technikę bipolarnej neuromodulacji z użyciem prądu PRF. Prawidłowość położenia elektrod potwierdzano neurofizjologicznie. Protokół badania składał się z kwestionariusza objawów zespołu cieśni nadgarstka (Boston Carpal Tunnel Questionnaire – BCTQ), skali numerycznej NRS (Numerical Rating Scale) dla oceny bólu oraz oceny siły mięśniowej przed neuromodulacją oraz 4 i 12 tygodni po leczeniu. Ponadto oceniano szybkość przewodnictwa czuciowego w nerwie pośrodkowym (sensory nerve conduction velocity – SNCV) przed i 12 tygodni po interwencji. WYNIKI: Stwierdzono znamienną poprawę w zakresie podskal BCTQ dotyczących ciężkości objawów (33,53 ± 8,25 przed zabiegiem vs. 18,33 ± 11,06 i 25,67 ± 12,39 po upływie 4 i 12 tygodni od zabiegu) oraz stanu czynnościowego (21,0 ± 5,79 vs. 12,07 ± 7,20 i 17,73 ± 9,09), a także poprawę siły mięśniowej (3,39 ± 1,68 vs. 5,86 ± 1,98 i 4,93 ± 2,22). Ponadto stwierdzono redukcję bólu i poprawę SNCV, jednak parametry te nie osiągnęły znamienności statystycznej. WNIOSKI: Neuromodulacja nerwu pośrodkowego za pomocą prądu PRF przeprowadzona techniką bipolarną jest obiecującą metodą leczenia pacjentów z CTS i może być alternatywą dla chirurgicznego uwolnienia nerwu pośrodkowego. Dla oceny trwałości poprawy klinicznej po zastosowanym leczeniu konieczny będzie dłuższy okres obserwacji.
Źródło:
Annales Academiae Medicae Silesiensis; 2021, 75; 107-110
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analyses of residential building efficiency for AC and DC distribution networks
Autorzy:
Ahmad, Faraz
Dastgeer, Faizan
Gelani, Hasan E.
Khan, Sidra
Nasir, Mashood
Powiązania:
https://bibliotekanauki.pl/articles/2173601.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC distribution system
efficiency analysis
AC vs DC
residential buildings
solar PV
system dystrybucji prądu stałego
analiza wydajności
prąd zmienny
prąd stały
AC/DC
budynki mieszkalne
fotowoltaika
Opis:
The escalating prevalence of rooftop solar PVs and DC powered home appliances are the driving forces for the research in the field of DC distribution at residential level. The current research work presents comparative analyses of AC and DC distribution systems considering various scenarios for the specific purpose of efficiency/energy savings. A modern Bakersfield CA, USA home is considered for the analyses. The loads are classified according to the power demand. Rooftop solar PVs are also included in each residential building. Mathematical equations are devised for the efficiency analysis of residential buildings powered with AC as well as DC. The results reveal strong dependence of the efficiency values on the utilization/types of loads, efficiencies of the power electronic converters (PECs), solar capacity and seasonal conditions, as a function of the time of day. It is concluded that AC system presents better efficiency values as compared to the DC counterpart except during the time periods when solar power is available and when the penetration of variable speed drive (VSD) based loads is high.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; art. no. e136732
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analyses of residential building efficiency for AC and DC distribution networks
Autorzy:
Ahmad, Faraz
Dastgeer, Faizan
Gelani, Hasan E.
Khan, Sidra
Nasir, Mashood
Powiązania:
https://bibliotekanauki.pl/articles/2128137.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC distribution system
efficiency analysis
AC vs DC
residential buildings
solar PV
system dystrybucji prądu stałego
analiza wydajności
prąd zmienny
prąd stały
AC/DC
budynki mieszkalne
fotowoltaika
Opis:
The escalating prevalence of rooftop solar PVs and DC powered home appliances are the driving forces for the research in the field of DC distribution at residential level. The current research work presents comparative analyses of AC and DC distribution systems considering various scenarios for the specific purpose of efficiency/energy savings. A modern Bakersfield CA, USA home is considered for the analyses. The loads are classified according to the power demand. Rooftop solar PVs are also included in each residential building. Mathematical equations are devised for the efficiency analysis of residential buildings powered with AC as well as DC. The results reveal strong dependence of the efficiency values on the utilization/types of loads, efficiencies of the power electronic converters (PECs), solar capacity and seasonal conditions, as a function of the time of day. It is concluded that AC system presents better efficiency values as compared to the DC counterpart except during the time periods when solar power is available and when the penetration of variable speed drive (VSD) based loads is high.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136732, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhanced feature extraction algorithms using oscillatory-mode pulsed Eddy Current techniques for aircraft structure inspection
Wykorzystanie techniki impulsowych prądów wirowych (PEC) w trybie oscylacyjnym do ulepszenia algorytmów do wyodrębnienia cech w kontroli struktury samolotu
Autorzy:
Lysenko, Iuliia
Kuts, Yurii
Protasov, Anatoliy
Redka, Mykhailo
Uchanin, Valentin
Powiązania:
https://bibliotekanauki.pl/articles/36443448.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
pulsed eddy current
natural oscillation frequency
attenuation
amplitude signal characteristics
phase signal characteristics
impulsowy prąd wirowy
częstotliwość drgania naturalnego
osłabienie
amplituda sygnału fazowego
właściwości sygnału fazowego
Opis:
A review of the existing literature shows that modern pulsed eddy current (PEC) technique for flaw detection in aircraft structure inspection is typically carried out in aperiodic mode. At the same time, the unstable characteristic points of the EC signal usually used as informative parameters can restrict the potential of this excitation mode due to significant measurement errors. This article considers an advanced PEC method of NDT based on the oscillatory mode. To obtain the conditions concerned with different modes of EC probe response oscillations, an equivalent scheme of the "testing object - EC probe" system was developed and analyzed. The frequency and attenuation coefficient of natural oscillations are proposed as the informative parameters of the probe signals. The obtained mathematical model of the probe signals allows for the dependence of proposed signal parameters on the characteristics of the testing object to be evaluated. Herein, we first develop algorithmic software for determining and analyzing the discrete amplitude and phase characteristics of PEC NDT signals based on the simulation results. The errors of the natural frequency oscillations and the attenuation coefficient determination as well as the optimal time for its determination are analyzed in order to minimize the possible errors. Next, the proposed informative parameters are experimentally investigated using a set of specimens. The obtained results confirm the possibility of the proposed methodology to enhance the inspection procedures related to the electrical conductivity and geometric parameters measurements as well as the detected defect sizing.
Przegląd istniejącej literatury wskazuje, że nowoczesna technika impulsowych prądów wirowych (PEC) do wykrywania wad w inspekcji konstrukcji lotniczych jest zwykle prowadzona w trybie aperiodycznym. Przy tym, niestabilne punkty charakterystyczne w sygnale prądów wirowych, które zwykle są używane jako parametry informacyjne, mogą ograniczać potencjał tego trybu wzbudzenia ze względu na znaczne błędy pomiarowe. W niniejszym artykule rozważano zaawansowaną metodę PEC dla badań nieniszczących (NDT) opartą na trybie oscylacyjnym. W celu uzyskania warunków związanych z różnymi trybami oscylacji odpowiedzi sondy prądów wirowych, opracowano i przeanalizowano równoważny schemat układu „obiekt badany - sonda”. Jako parametry informacyjne dla sygnałów brano częstotliwość i współczynnik tłumienia drgań własnych.Tak powstały model matematyczny sygnałów pozwala na ocenęzależności proponowanych parametrów sygnałów od właściwości obiektu badanego. Najpierw na podstawie wyników symulacji opracowano algorytmiczne oprogramowanie do wyznaczania i analizy dyskretnych charakterystyk amplitudowych i fazowych sygnałów PEC NDT. Analizowano błędy wyznaczania częstotliwości drgań własnych oraz współczynnika tłumienia, a także optymalny czas jego wyznaczania w celu minimalizacji możliwych błędów. Następnie, zaproponowane parametry informacyjne badano eksperymentalnie z wykorzystaniem zestawu próbek. Otrzymane wyniki potwierdzają możliwość zastosowania proponowanej metody do usprawnienia procedur inspekcyjnych związanych z pomiarami przewodności elektrycznej, parametrów geometrycznych oraz oceny rozmiarów wykrywanych defektów.
Źródło:
Transactions on Aerospace Research; 2021, 3 (264); 1-16
0509-6669
2545-2835
Pojawia się w:
Transactions on Aerospace Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study on fault ride-through capability of VSC-based HVDC transmission system
Autorzy:
Khoa, Ngo Minh
Toan, Nguyen An
Tung, Doan Duc
Powiązania:
https://bibliotekanauki.pl/articles/1841366.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
converter system
experimental waveform
fault ride through
High Voltage Direct Current
voltage sag
system konwertera
eksperymentalny przebieg
prąd stały wysokiego napięcia
spadek napięcia
Opis:
For voltage-source-converter based high-voltage-direct-current (VSC-HVDC)transmission systems, fault ride-through (FRT) capability is a very important grid requirement in order to enhance its operational availability under an alternating current (AC) gridfault condition. Voltage sags during a short-circuit fault in power transmission lines can leadto fluctuations in the direct current (DC) link voltage of converter systems, and may inducereversed power flow and even trip a VSC-HVDC transmission system. A practical methodis developed in this paper for investigating FRT capability of VSC-HVDC transmissionsystem characteristics during a voltage sag event using experimental results from Smart Grid Laboratory. Symmetrical and asymmetrical voltage sag events with different remaining voltages are applied to an AC grid that lasts with a variable duration. The experimental waveforms of the two converter systems are recorded and analyzed in order to evaluate theFRT capability of VSC-HVDC transmission systems.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 37-51
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of plastic deformation carbon steel on the process of burning electric arc
Autorzy:
Vakulenko, Igor Alex
Plitchenko, Sergey
Kurt, Bulent
Askerov, Hangardas
Proydak, Svetlana
Erdogdu, Ahmet Emrah
Powiązania:
https://bibliotekanauki.pl/articles/2091226.pdf
Data publikacji:
2021
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
substructure
density dislocation
electric current
plastic deformation
cementite
ferrite
podbudowa
dyslokacja gęstości
prąd elektryczny
deformacja plastyczna
cementyt
ferryt
Opis:
During a study of the combustion process of a direct polarity electric arc, a directly proportional dependence of the electric current value on the degree of cold plastic deformation of carbon steel used as an electrode was found. To calculate the value of the electric current during arc burning, in the indicated ratio, it was proposed to replace the surface tension force of the liquid metal with the surface tension of ferrite of plastically deformed carbon steel. Calculation of the ferrite’s surface tension value on the deformation degree of the steel under study through the size of the coherent scattering regions was used to explain the observed dependence of the electric current during arc burning. From the analysis of the considered correlation ratios, it was found that with an increase in the cold deformation degree, the refinement of the coherent scattering regions results in the ferrite’s surface tension increase and consequently, to an increase in the electric current during arc burning. Comparative analysis of the obtained results of calculating the value of electric current during arc burning through the surface tension of ferrite of cold-deformed carbon steel showed a fairly good coincidence with experimental data. The differences did not exceed 9%.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2021, 112; 211--218
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies