Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power system stability" wg kryterium: Temat


Tytuł:
A Method of Power System Static Stability Analysis
Metoda analizy stabilności statycznej systemów elektroenergetycznych
Autorzy:
Oziemblewski, K.
Opala, K.
Powiązania:
https://bibliotekanauki.pl/articles/397638.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
static stability of power system
grid stiffness
power swings
stabilność statyczna systemu elektroenergetycznego
sztywność sieci
kołysania mocy
Opis:
The paper reports on a study of changes in a power system’s operating parameters under a rise in its load. The results of these and similar studies may lead to an expansion of current views on a grid’s stiffness, its stability and conditions for power swings development in the system. Power swings are often the beginnings of widespread system failures.
Treść artykułu dotyczy badania zmian parametrów pracy systemu elektroenergetycznego w warunkach narastania jego obciążenia. Wyniki tych i podobnych badań mogą prowadzić do rozszerzenia aktualnych poglądów na temat sztywności sieci, jej stabilności i warunków postawania kołysań mocy w systemie. Kołysania mocy często stanowią początek rozległych awarii systemowych.
Źródło:
Acta Energetica; 2016, 1; 102-108
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel approach for power system stabilizer control parameter selection: a case-study on two-area four-machine system
Autorzy:
Gude, Murali Krishna
Salma, Umme
Powiązania:
https://bibliotekanauki.pl/articles/2086725.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
grey wolf optimizer
power system stabilizer
optimization
stability
Opis:
This paper proposes a power system stabilizer (PSS) with optimal controller parameters for damping low-frequency power oscillations in the power system. A novel meta-heuristic, weighted grey wolf optimizer (GWO) has been proposed, it is a variant of the grey wolf optimizer (GWO). The proposed WGWO algorithm has been executed in the selection of controller parameters of a PSS in a multi-area power system. A two-area four- machine test system has been considered for the performance evaluation of an optimally tuned PSS. A multi-objective function based on system eigenvalues has been minimized for obtained optimal controller parameters. The damping characteristics and eigenvalue location in the proposed approach have been compared with the other state-of-the-art- methods, which illustrates the effectiveness of the proposed approach.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 297--407
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An overview of design, control, power management, system stability and reliability in electric ships
Autorzy:
Ni, K.
Hu, Y.
Li, X.
Powiązania:
https://bibliotekanauki.pl/articles/1193412.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
electric ship
control algorithms
power electronics techniques
power drive system
stability
Opis:
With the fast development of power electronics techniques, electrification of shipboard power systems (SPS) is an unstoppable trend, and the concepts of electric ships (ESs) and all-electric ships (AESs) emerge. In order to meet the constantly increasing electricity demand in SPS, the medium voltage direct current (MVDC) SPS becomes a promising shipboard electrical network architecture. This paper aims to present a comprehensive review of the design, control, power management, system stability and reliability in ESs. The most recent technologies and academic achievements in these fields are discussed. In the near future, it is possible that the electric propulsion technology will be widely applied to various types of ships.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 5-29
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu sposobu modelowania nowych źródeł wytwórczych na wskaźniki oceny stabilności systemu elektroenergetycznego
The way of modeling new generation sources and its effect on the power system stability evaluation parameters
Autorzy:
Miller, P.
Wancerz, M.
Powiązania:
https://bibliotekanauki.pl/articles/267663.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
system elektroenergetyczny
stabilność
planowanie rozwoju sieci
power system
stability
network planning
short-circuit power
Opis:
W artykule zbadano wpływ sposobu i dokładności modelowania układów automatycznej regulacji nowych bloków wytwórczych na wskaźniki oceny stabilności systemu elektroenergetycznego. Wskaźnikami oceny są czasy krytyczne trwania zwarcia tkr oraz odpowiadające im współczynniki zapasu stabilności kt, czasy połowienia t50% oraz czasy regulacji t15%.
An effect of the way and accuracy of modeling automatic control systems of generating units on parameters of the power system stability evaluation has been investigated. The evaluation parameters are the following: values of the critical shortcircuit time tkr, and corresponding to them values of the stability margin kt,, and the regulation times t50% and t15%. The obtained results make an attempt to establishing the effect of the way generating units are modeled on the conclusions following from the power system stability analyses.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 59-62
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Polish Power System angular stability based on analysis of different disturbance waveforms
Autorzy:
Pruski, P.
Paszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/202048.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power system
eigenvalues associated with electromechanical phenomena
angular stability
system zasilania
wartości własne
zjawisko elektromechaniczne
stabilność kątowa
Opis:
The paper presents investigation results concerning assessment of the Polish Power System (PPS) angular stability based on power system state matrix eigenvalues associated with electromechanical phenomena, when using the angular stability factors calculated on the basis of these eigenvalues. The eigenvalues were calculated by analysis of the disturbance waveforms of the instantaneous power, angular speed and power angle of synchronous generators in PPS generating units when taking into account introduction of a disturbance to different units. There was assumed a disturbance in the form of a rectangular pulse introduced to the voltage regulation system of a generating unit. There was also analysed the effect of the duration of the introduced test disturbance on the calculation results of the eigenvalue influencing the measurement waveforms of the instantaneous power of generating unit no 5 in Rybnik Power Plant. The method for eigenvalue calculations used in the investigations consists in approximation of the disturbance waveforms in particular generating units with the use of the waveforms being a superposition of the modal components associated with the searched eigenvalues. The hybrid optimisation algorithm being a serial combination of the genetic and gradient algorithms was used for computations.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 435-441
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of system state matrix eigenvalues based on analysis of instantaneous power waveforms at short-circuit disturbances
Obliczenia wartości własnych macierzy stanu systemu na podstawie analizy przebiegów mocy chwilowej przy zakłóceniach zwarciowych
Autorzy:
Pruski, P.
Paszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/397175.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
power system
angular stability
electromechanical eigenvalues
transient states
system elektroenergetyczny
stabilność kątowa
elektromechaniczne wartości własne
stany nieustalone
Opis:
W artykule przedstawiono wyniki obliczeń wartości własnych (związanych ze zjawiskami elektromechanicznymi) macierzy stanu modelu systemu elektroenergetycznego (SEE) na podstawie analizy przebiegów zakłóceniowych mocy chwilowej zespołów wytwórczych SEE. Analizowano zakłócenia w postaci zwarcia małoprądowego w różnych liniach przesyłowych SEE. Wykorzystana metoda obliczeń wartości własnych polega na aproksymacji analizowanych przebiegów zakłóceniowych za pomocą przebiegów będących superpozycją składowych modalnych związanych z poszukiwanymi wartościami własnymi. Aproksymacja ta polega na minimalizacji funkcji celu określonej jako błąd średniokwadratowy, występujący między przebiegiem aproksymowanym i aproksymującym. Do minimalizacji funkcji celu wykorzystano hybrydowy algorytm optymalizacyjny, stanowiący szeregowe połączenie algorytmu genetycznego i gradientowego. Połączenie to eliminuje podstawowe wady obu algorytmów. Aby uniknąć błędów obliczeń spowodowanych utknięciem algorytmu w minimum lokalnym funkcji celu, obliczenia wartości własnych dla każdego przebiegu przeprowadzano wielokrotnie.
The paper presents the results of calculations of the eigenvalues (associated with electromechanical phenomena) of the state matrix of a power system (PS) model, based on analysis of the disturbance waveforms of instantaneous power of PS generating units. There were taken into account disturbances in the form of a low-current short circuit in various PS transmission lines. The eigenvalue calculation method used in the investigations consists in the approximation of the analysed disturbance waveforms with waveforms being a superposition of modal components associated with the searched eigenvalues. This approximation consist in the minimisation of the objective function defined as the mean square error that occurs between the approximated and approximating waveform. For the objective function minimisation, a hybrid optimisation algorithm being a serial connection of the genetic and gradient algorithms was used. This connection eliminates the basic disadvantages of these both algorithms. To avoid calculation errors caused by the algorithm getting stuck in the objective function local minimum, the eigenvalues were calculated repeatedly for each waveform.
Źródło:
Acta Energetica; 2017, 2; 177-183
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculations of Electromechanical Eigenvalues Based on Generating Unit Instantaneous Power and Angular Speed Waveforms at a Step Disturbance
Obliczenia elektromechanicznych wartości własnych na podstawie przebiegów mocy chwilowej i prędkości kątowej zespołów wytwórczych przy zakłóceniu skokowym
Autorzy:
Pruski, P.
Paszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/397197.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
power system
angular stability
eigenvalues associated with electromechanical phenomena
transient states
system elektroenergetyczny
stabilność kątowa
wartości własne związane ze zjawiskami elektromechanicznymi
stany nieustalone
Opis:
The paper presents the results of calculations of eigenvalues (associated with electromechanical phenomena) of a power system model state matrix made on the basis of analysis of disturbance waveforms of generating unit instantaneous power and angular speed. The waveforms that occur after introducing a disturbance in the form of a change in the voltage regulator reference voltage in one of the power system generating units were taken into account in the calculations. The power system model included the impact of a central frequency regulator. The eigenvalue calculation method used in the investigations consists in approximation of the analysed instantaneous power disturbance waveforms by the waveforms being a superposition of modal components associated with the searched eigenvalues and their participation factors. This approximation involves the minimisation of an objective function defined as the mean square error between the approximated and approximating waveforms. For minimisation of the objective function, a hybrid optimisation algorithm consisting of serially connected genetic and gradient algorithms was used. This combination allows one to eliminate fundamental drawbacks of both algorithms.
W artykule przedstawiono wyniki obliczeń wartości własnych (związanych ze zjawiskami elektromechanicznymi) macierzy stanu modelu systemu elektroenergetycznego (SEE), dokonane na podstawie analizy przebiegów zakłóceniowych mocy chwilowej i prędkości kątowej zespołów wytwórczych SEE. Wzięto pod uwagę przebiegi występujące po wprowadzeniu zakłócenia w postaci skokowej zmiany napięcia zadanego regulatora napięcia w jednym z zespołów wytwórczych SEE. W wykorzystanym modelu SEE uwzględniono oddziaływanie centralnego regulatora częstotliwości. Wykorzystana w artykule metoda obliczeń wartości własnych polega na aproksymacji analizowanych przebiegów zakłóceniowych za pomocą przebiegów stanowiących superpozycję składowych modalnych związanych z poszukiwanymi wartościami własnymi i ich czynnikami udziału. Aproksymacja ta polega na minimalizacji funkcji celu określonej jako błąd średniokwadratowy, występujący między przebiegiem aproksymowanym i aproksymującym. Do minimalizacji tak określonej funkcji celu wykorzystano hybrydowy algorytm optymalizacyjny, stanowiący szeregowe połączenie algorytmu genetycznego i gradientowego. Połączenie to pozwala na wyeliminowanie podstawowych wad obu algorytmów.
Źródło:
Acta Energetica; 2015, 2; 68-77
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of multi-criteria decision making methods for the assessment of optimal SVC location
Autorzy:
Aydin, Faruk
Gümüş, Bilal
Powiązania:
https://bibliotekanauki.pl/articles/2173650.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Borda count method
FACTS
MCDM
optimal location
PSAT
voltage stability
flexible alternating current transmission system
power system analysis toolbox
multi criteria decision making
metoda liczenia Bordy
podejmowanie decyzji wielokryterialnej
lokalizacja optymalna
stabilność napięcia
elastyczne systemy przesyłowe prądu przemiennego
narzędzia do analizy systemu zasilania
Opis:
The goal of multi-criteria decision making (MCDM) is to select the most appropriate of the alternatives by evaluating many conflicting criteria together. MCDM methods are widely available in the literature and have been used in various energy problems. The key problems studied in electrical power systems in recent years have included voltage instability and voltage collapse. Different flexible alternating current transmission systems (FACTS) equipment has been used for this purpose for decades, increasing voltage stability while enhancing system efficiency, reliability and quality of supply, and offering environmental benefits. Finding the best locations for these devices in terms of voltage stability in actual electrical networks poses a serious problem. Many criteria should be considered when determining the most suitable location for the controller. The aim of this paper is to provide a comparative analysis of MCDM techniques to be used for optimal location of a static VAR compensator (SVC) device in terms of voltage stability. The ideal location can be determined by means of sorting according to priority criteria. The proposed approach was carried out using the Power System Analysis Toolbox (PSAT) in MATLAB in the IEEE 14-bus test system. Using ten different MCDM methods, the most appropriate locations were compared among themselves and a single ranking list was obtained, integrated with the Borda count method, which is a data fusion technique. The application results showed that the methods used are consistent among themselves. It was revealed that the integrated model was an appropriate method that could be used for optimal location selection, providing reliable and satisfactory results to power system planners.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140555
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Damping low-frequency oscillations in a multi-machine power system using a fuzzy-multi-band power system stabilizer
Autorzy:
Essallah, Sirine
Khedher, Adel
Powiązania:
https://bibliotekanauki.pl/articles/41178019.pdf
Data publikacji:
2022
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
power system stability
low-frequency oscillations
Fuzzy-MB-PSS
stabilność systemu elektroenergetycznego
niska częstotliwość
oscylacje
Opis:
Synchronous generators are usually eguipped with power system stabilizers (PSS) to damp low-freguency oscillations. Among the various types of PSS, it has recently been demonstrated that the Multi-Band PSS (MB-PSS) has a better performance to handle all global, inter-area and local modes. However, the performance of this PSS may degrade since the power supply system is intrinsically non-linear and its operating conditions freguently change. This paper introduces a new design of MB-PSS based on Mamdani Fuzzy inference (Fuzzy-MB-PSS). Compared to the IEEE standard MB-PSS, the proposed stabilizer is more efficient owing to its ability to deal with oscillations at different operating points. The controller is tested on a power system benchmark under various disturbance conditions to prove its robustness and to demonstrate its superiority over conventional PSS and MB-PSS.
Źródło:
Journal of Power Technologies; 2022, 102, 4; 140-148
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of protective and stabilizing controllers: a study with considering natural events
Autorzy:
Ganji, E.
Mahdavian, M.
Shirzadi, H.
Powiązania:
https://bibliotekanauki.pl/articles/141493.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wind turbine
error detection system
output stability of the turbine
crow bar circuit
tuning PI controllers
power quality
Opis:
In renewable systems, there may be conditions that can be either network error or power transmission line and environmental conditions such as when the wind speed is unbalanced and the wind turbine is connected to the grid. In this case, the control system is not damaged and will remain stable in the power transmission system. Voltage stability studies on an independent wind turbine at fault time and after fixing the error is one of the topics that can strengthen the future of independent collections. At the time of the fault, the network current increases dramatically, resulting in a higher voltage drop. Hence the talk of fast voltage recovery during error and after fixing the error and protection of rotor and grid side converters against the fault current and also protection against rising DC voltage (which sharply increases during error) is highly regarded. So, several improvements have been made to the construction of a doubly-fed induction generator (DFIG) turbine such as: a) error detection system, b) DC link protection, c) crow bar circuit, d) block of the rotor and stator side converters, e) injecting reactive power during error, f) nonlinear control design for turbine blades, g) tuning and harmonization of controllers used to keep up the power quality and to stabilize the system output voltage in the power grid. First, the dynamic models of a wind turbine, gearbox, and DFIG are presented. Then the controllers are modeled. The results of the simulation have been validated in MATLAB/Simulink.
Źródło:
Archives of Electrical Engineering; 2018, 67, 4; 869-884
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of electromechanical eigenvalues based on analysis of different disturbance waveforms of a power system
Autorzy:
Pruski, P.
Paszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/97708.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power system
eigenvalues associated with electromechanical phenomena
transient states
angular stability
Opis:
The paper presents the calculation results of the power system state matrix eigenvalues associated with electromechanical phenomena (i.e. electromechanical eigenvalues). There is compared the accuracy of eigenvalue calculations performed on the basis of the analysis of disturbance waveforms of instantaneous power, angular speed and power angle of generators of particular generating units of the power system. The method used for eigenvalue calculations consists in approximation of the disturbance waveforms of generating units with waveforms being a superposition of modal components whose parameters depend on the searched eigenvalues and their participation factors. A hybrid optimisation algorithm, being a serial combination of genetic and gradient algorithms, is used for minimisation of the objective function defined as a mean square error between the approximated and approximating waveforms. In order to increase the calculation accuracy, computations were repeated many times. The computation results were averaged.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 130-143
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Transmission Grid Voltage Impact on the Operation of Power Units’ Auxiliary Systems
Ocena wpływu poziomu napięcia w sieci przesyłowej na funkcjonowanie układów potrzeb własnych bloków energetycznych
Autorzy:
Paska, J.
Kłos, M.
Rosłaniec, Ł.
Bielas, R.
Błędzińska, M.
Głaz, M.
Powiązania:
https://bibliotekanauki.pl/articles/397203.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
power system emergency states
voltage stability
power units
supply of unit auxiliaries
stany awaryjne systemu elektroenergetycznego
stabilność napięciowa
blok energetyczny
zasilanie potrzeb własnych
Opis:
This paper presents the low voltage impact on the operation of critical auxiliaries of selected generation units in the national power system. Time limits are determined for the operation of these auxiliaries at low voltage in the power system and the acceptable reduced voltages in their secondary circuits at which the generation unit is capable of interoperation with the system. Upgrades of auxiliary systems are proposed which would enable interoperation of the unit and the system at significantly reduced system voltages.
W artykule przedstawiono wpływ niskich poziomów napięć na funkcjonowanie newralgicznych odbiorników układów potrzeb własnych, wybranych bloków wytwórczych pracujących w KSE. Określono graniczne czasy pracy dla tych odbiorników przy niskich poziomach napięć w KSE oraz dopuszczalne, zaniżone poziomy napięć w obwodach wtórnych układów potrzeb własnych rozpatrywanych bloków wytwórczych, przy których blok wytwórczy jest w stanie współpracować z systemem elektroenergetycznym. Zaproponowano sposoby modernizacji układów potrzeb własnych umożliwiające współpracę bloku wytwórczego z KSE, przy znacznie zaniżonych napięciach w systemie elektroenergetycznym.
Źródło:
Acta Energetica; 2015, 4; 78-86
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast-Valving of Large Steam Turbine Units as a Means of Power System Security Enhancement
Szybkie zaworowanie turbin parowych dużych bloków jako środek zwiększenia bezpieczeństwa krajowego systemu elektroenergetycznego
Autorzy:
Sobczak, B.
Rink, R.
Kuczyński, R.
Trębski, R.
Powiązania:
https://bibliotekanauki.pl/articles/397462.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
fast-valving
power system stability
electric power engineering
szybkie zaworowanie
elektroenergetyka
Opis:
Fast-valving assists in maintaining system stability following a severe transmission system fault by reducing the turbine mechanical power. Fast-valving consists in rapid closing and opening of steam valves in an adequate manner to reduce the generator accelerating power following the recognition of a severe fault. FV can be an effective and economical method of meeting the performance requirements of a power system in the presence of an increase in wind and solar generation in the power system, newly connected large thermal units and delaying of building new transmission lines. The principle of fast-valving and advantages of applying this technique in large steam turbine units was presented in the paper. Effectiveness of fast-valving in enhancing the stability of the Polish Power Grid was analyzed. The feasibility study of fast-valving application in the 560 MW unit in Kozienice Power Station (EW SA) was discussed.
Autorzy przedstawili w artykule zasady działania szybkiego zaworowania (ang. fast-valving) i korzyści stosowania tej techniki we współczesnych systemach elektroenergetycznych. Omówione zostały modelowe badania skuteczności FV w warunkach KSE oraz analiza możliwości wprowadzenia FV na bloku 560 MW elektrowni Kozienice, wykonane w ramach I etapu pracy IASE Wrocław i Instytutu Energetyki Oddział Gdańsk dla Polskich Sieci Elektroenergetycznych SA, której przedmiotem jest analiza możliwości zastosowania FV w pracujących w KSE i planowanych do przyłączenia dużych blokach konwencjonalnych.
Źródło:
Acta Energetica; 2014, 1; 166-175
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High-speed power system stability simulation using analog computation
Autorzy:
Nagel, I.
Fabre, L.
Cherkaoui, R.
Kayal, M.
Powiązania:
https://bibliotekanauki.pl/articles/398151.pdf
Data publikacji:
2010
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
mikroelektroniczna emulacja
symulacja wysokiej prędkości
przemijająca stabilność systemu elektroenergetycznego
obliczenia analogowe
microelectronic emulation
high-speed simulation
power system transient stability
analog computation
ASIC
Opis:
This paper presents a microelectronic emulation approach for high-speed power system computation. First, the problems of existing power system simulators are detailed. This shows that microelectronic emulation is a possible solution for solving the speed problems of existing simulators. Second, this paper presents one specific emulation approach, the so-called AC emulation approach. The ultimate objective of the AC emulation approach is the realization of a power system emulator which reproduces simultaneously a large number of phenomena of different time constants or frequencies with a much higher speed than real time. Frequency dependence of the elements is preserved and the signals propagating in the emulated network are the shrunk or downscaled current and voltage waves of the real power network. The models of the power network components are detailed. Special attention is paid to the generator model which was shown to introduce a systematic error. This systematic error is quantified, analyzed and optimized. Moreover behavioral simulation results confirm the feasibility of this approach which in turn lays the foundation for such an emulator.
Źródło:
International Journal of Microelectronics and Computer Science; 2010, 1, 2; 180-187
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Investments in Generating Units and Transmission and Distribution Power Grids by 2025 on Voltage Stability and Branches Load in ENERGA SA Operational Territory – Main Findings of Research Project
Wpływ inwestycji do 2025 roku w moce wytwórcze oraz sieć przesyłową i dystrybucyjną na obciążalność węzłów i przeciążalność prądową linii znajdujących się na obszarze działania spółki ENERGA SA – najważniejsze wnioski z projektu badawczego
Autorzy:
Falkowski, D.
Zarzycki, M.
Powiązania:
https://bibliotekanauki.pl/articles/397074.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
power system
voltage stability
system elektroenergetyczny
stabilność napięciowa
Opis:
The article summarizes a research project which was conducted in order to ensure what will be the influence of future investments and changes in the Polish Power System on the stability and functionality of the ENERGA SA distribution grid system. Development of the ENERGA SA distribution grid system was also included. Only stable states were tested for various cases of system load and generation in power plants (the Nuclear Power Plant in Żarnowiec was taken into account) and also in wind farms. The system was also tested in N-1 and N-2 states. The result of this study is an overall evaluation of the ENERGA SA distribution grid condition, as well as the identification of potential weak points inside this structure.
Autorzy podsumowują projekt badawczy, zrealizowany jeszcze w trakcie studiów magisterskich, który miał na celu sprawdzenie, jak zmiany w systemie elektroenergetycznym do 2025 roku wpłyną na pracę sieci dystrybucyjnej 110 kV ENERGA SA. W projekcie skupiono się na stanach ustalonych pracy KSE dla różnych wariantów obciążenia systemu i generacji w jednostkach wytwórczych. System poddano analizie prace w stanach normalnych oraz awaryjnych przy przy wyłączeniu elementów KSE, tzw. analiza N-1 i N-2. Wynikiem opracowania była ogólna ocena przystosowania sieci dystrybucyjnej spółki ENERGA SA do pracy przy zmieniającej się strukturze KSE, jak również wskazanie potencjalnych najsłabszych punktów w strukturze zasilania sieci dystrybucyjnej.
Źródło:
Acta Energetica; 2013, 1; 4-17
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies