Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power quality energy" wg kryterium: Temat


Tytuł:
An advanced IoT system for monitoring and analysing chosen power quality parameters in micro-grid solution
Autorzy:
Khoa, Ngo Minh
Dai, Le Van
Tung, Doan Duc
Toan, Nguyen An
Powiązania:
https://bibliotekanauki.pl/articles/1841334.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy management
internet of things (IoT)
micro-grid
power quality (PQ)
ThingSpeak cloud
Opis:
This paper proposes an advanced Internet of Things (IoT) system for measuring, monitoring, and recording some power quality (PQ) parameters. The proposed systemis designed and developed for both hardware and software. For the hardware unit, three PZEM-004T modules with non-invasive current transformer (CT) sensors are used tomeasure the PQ parameters and an Arduino WeMos D1 R1 ESP8266 microcontroller isused to receive data from the sensors and send this data to the server via the internet. For the software unit, an algorithm using Matlab software is developed to send measurement datato the ThingSpeak cloud. The proposed system can monitor and analyse the PQ parameters including frequency, root mean square (RMS) voltage, RMS current, active power, and the power factor of a low-voltage load in real-time. These PQ parameters can be stored on theThingSpeak cloud during the monitoring period; hence the standard deviation in statistics of the voltage and frequency is applied to analyse and evaluate PQ at the monitoring point.The experimental tests are carried out on low-voltage networks 380/220 V. The obtained results show that the proposed system can be usefully applied for monitoring and analysing chosen PQ parameters in micro-grid solutions.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 173-188
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza hydrologiczno-środowiskowa lokalizacji małej elektrowni wodnej na rzece Budkowiczanka w miejscowości Krzywa Góra
Hydrological and environmental analysis of the location of a small hydropower plant on the Budkowiczanka River in the village of Krzywa Góra
Autorzy:
Wiatkowski, M.
Gruss, Ł.
Tomczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/399920.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
małe elektrownie wodne
odnawialne źródła energii
moc teoretyczna elektrowni
hydrologia
wskaźnik względnego opadu
odpływ
jakość wody
rzeka Budkowiczanka
small hydro power
renewable energy sources
mechanical power
hydrology
relative precipitation index
outflow
water quality
Budkowiczanka River
Opis:
W niniejszym artykule Autorzy przedstawili analizę warunków hydrologiczno-środowiskowych w aspekcie lokalizacji małej elektrowni wodnej na rzece Budkowiczance. Zlewnia rzeki Budkowiczanki wynosi A=232 km2 i znajduje się w południowo–zachodniej Polsce w województwie opolskim. Długość rzeki Budkowiczanki wynosi ok. 60 km. Autorzy zaproponowali lokalizację małej elektrowni wodnej na jazie w km 20,142 jej biegu w miejscowości Okoły-Kupi Las w gminie Murów. Badany przekrój należy zaliczyć do jednolitej części wód powierzchniowych „Budkowiczanka od Wiszni do Stobrawy”. Planowany na cele małej energetyki wodnej jaz zlokalizowany jest w odległości około 1,7 km powyżej wodowskazu Krzywa Góra. Przeanalizowano warunki hydrologiczne w rzece Budkowiczance dla profilu wodowskazowego Krzywa Góra. Na potrzeby hydrotechniki, dla rzeki Budkowiczanka, w przekroju wodowskazowym Krzywa Góra, wyznaczono stany i przepływy charakterystyczne obejmujące okres 1981-2015. Dla poszczególnych rocznych sum opadów z wielolecia 1981-2015, dla stacji Opole zlokalizowanej w pobliżu zlewni rzeki Budkowiczanki wyznaczono lata bardzo suche i suche. Dla tych lat wyznaczono miary odpływu takie jak: współczynnik odpływu, wysokość warstwy odpływu, objętość odpływu. Wyznaczono również moc teoretyczną elektrowni, w oparciu o przepływ średni w wybranych latach oraz przepływ najdłużej trwający. W badanym cieku stwierdzono występowanie ośmiu gatunków ryb. Po względem elementów: biologicznych, hydromorfologicznych i fizykochemicznych z lat 2012 i 2015, potencjał ekologiczny JCWP jest jedynie umiarkowany, a tym samym stan jednolitej części wód – zły.
In this article, the Authors presented an analysis of hydrological and environmental conditions in the aspect of the location of a small hydropower plant on the Budkowiczanka River. The catchment of the Budkowiczanka River is A = 232 km2 and it’s located in south-western Poland in the Opolskie Province. The length of the Budkowiczanka River is about 60 km. The authors proposed the location of a small hydropower at 20,142 km of its run in Okoły-Kupi Las in the Murów commune. The analyzed cross-section should be included in the body of surface water „Budkowiczanka from Wisznia to Stobrawa”. The weir planned for the purposes of small hydropower is located approximately 1.7 km above the Krzywa Góra gauging station. Hydrological conditions were analyzed in the Budkowiczanka River for the Krzywa Góra profile. For the hydrotechnic purposes states and discharges were determined. Based on the annual sums of precipitations for the Opole station, from the multi-year period of 1981–2015, very dry and dry years have been designated. This station is located near the Budkowiczanka River catchment. For these years, outflow measures were determined such as: outflow coefficient, height of the outflow layer, outflow volume. The theoretically available power of the hydropower plant was also determined, based on the average flow and the longest running flow in the selected years. In the studied river, eight species of fish were found. In terms of biological, hydromorphological and physicochemical elements from year 2012 and 2015, the ecological potential of surface water body is only moderate, and thus the status of water body is bad.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 6; 103-113
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the electric power quality on the polish fishing boats
Ocena jakości energii elektrycznej na polskich kutrach rybackich
Autorzy:
Tarnapowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/1205717.pdf
Data publikacji:
2015
Wydawca:
STE GROUP
Tematy:
electrical power quality
electrical energy system of fishing boats
quality parameters of electrical energy
passive filter
jakość energii elektrycznej
system elektroenergetyczny kutrów rybackich
parametry jakości energii elektrycznej
filtr pasywny
Opis:
Power quality is an important problem for electrical systems. Electricity receivers should operate at nominal conditions. Each deviation from nominal values may cause the malfunction of electrical devices, decreasing their durability and permanently damage the appliance. The importance of electric power quality for technical systems and individual electrical devices on fishing boats is fundamental. Utilization of equipment powered by electrical energy with a reduced quality resulting in economical losses and the treat to the screw's safety. Researches of the electrical energy's quality were carried out almost any type of fishing boats. This article presents the results of researches concerning the quality of electrical energy performed on a representative type of fishing boats. It shortly evaluates the results of tests and suggests solutions to improve the power quality parameters.
Jakość zasilania jest ważnym problemem dla systemów elektrycznych. Odbiorniki energii elektrycznej powinny pracować w warunkach znamionowych. Każde odchylenie od wartości znamionowych może powodować nieprawidłową pracę urządzeń elektrycznych, zmniejszenie ich trwałości, a w konsekwencji trwałe uszkodzenie. Znaczenie jakości energii elektrycznej dla systemów technicznych i pojedynczych urządzeń elektrycznych na kutrach rybackich jest fundamentalne. Eksplantacja urządzeń zasilanych energią elektryczną o obniżonej jakości skutkuje stratami ekonomicznymi i zagrożeniem bezpieczeństwa załogi. Badaniom jakości energii elektrycznej poddana została większość typów polskich kutrów rybackich. W niniejszym artykule przedstawiono wyniki badań jakości energii elektrycznej przeprowadzone na reprezentatywnym typie kutrów rybackich. Dokonano krótkiej oceny wyników badań i zaproponowano rozwiązania poprawiające parametry jakości energii elektrycznej.
Źródło:
Management Systems in Production Engineering; 2015, 3 (19); 123-127
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Celowość stosowania analizy skupień do oceny zagadnień związanych z jakością energii elektrycznej w sieciach kopalnianych
The purpose of using the cluster analysis to evaluate the issues related to the quality of the electric power in the mining networks
Autorzy:
Jasiński, M.
Sikorski, T.
Powiązania:
https://bibliotekanauki.pl/articles/131375.pdf
Data publikacji:
2017
Wydawca:
Uczelnia Jana Wyżykowskiego
Tematy:
jakość energii elektrycznej
JEE
analiza skupień
długoterminowe dane jakości energii elektrycznej
zdarzenia napięciowe
zasilanie zakładów górniczych
generacja rozproszona
odnawialne źródła energii
power quality
cluster analysis
long term power quality data
voltage events
mining plant supply
distributed generation
renewable sources of energy
Opis:
Artykuł prezentuje możliwość zastosowania analizy skupień w analizie danych jakości energii elektrycznej. Pierwsza cześć opisuje ogólnie metody aglomeracji danych oraz wskazuje miejsce analizy skupień w eksploracji danych. Druga część wykazuje cechy analizy skupień sprzyjające zastosowaniu w analizie danych jakości energii elektrycznej. Cześć trzecia to analiza przypadku zastosowania analizy skupień do wyłonienia zdarzeń napięciowych na podstawie posiadanych danych z stacji elektroenergetycznej wybranego zakładu górniczego zlokalizowanego w Zagłębiu Miedziowym. W artykule wyłonienie zdarzeń napięciowych polega na przeprowadzeniu analizy skupień z zastosowaniem algorytmu K-średnich, czego dokonuje się, dobierając odległości Czebyszewa przy zadanej liczby skupień.
The article states that cluster analysis may be used to power quality analysis. First part presents generally the data mining and indicate the placement of cluster analysis in data mining techniques. Second part shows the property indicates of cluster analysis, which indicate the possibility of using it in power quality data analysis. Third part is a case study how to indicates the voltage events by clustering based on power quality data of mining plant in Zagłębie Miedziowe. The indication is made by using K-mean algorithm - Chebyshev distance with the selected number of cluster.
Źródło:
Zeszyty Naukowe Uczelni Jana Wyżykowskiego. Studia z Nauk Technicznych; 2017, 6; 103-110
2543-6740
Pojawia się w:
Zeszyty Naukowe Uczelni Jana Wyżykowskiego. Studia z Nauk Technicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined monitoring and time-frequency analysis for transients in wind energy systems
Autorzy:
Łobos, T.
Sikorski, T.
Amarís, H
Alonso, M
Florez, D
Powiązania:
https://bibliotekanauki.pl/articles/1395766.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power quality monitoring
wind energy
wind power plant
Opis:
The aim of this paper is the application of selected time-varying power quality indices combined with detailed time-frequency analysis for assessment of transients in wind energy system. Presented proposition utilizes short-term harmonic distortion in voltage (STHDV) characteristic as an indicator for detail local time-frequency analysis of the transients. Introduced ideas can be treated as hybrid system absorbing both power quality indices and time-frequency representation.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 261-269
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność energetyczna urządzeń oświetleniowych a jakość energii elektrycznej
Energy efficiency of lighting devices versus power quality
Autorzy:
Czapp, S.
Powiązania:
https://bibliotekanauki.pl/articles/268717.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
oświetlenie elektryczne
efektywność energetyczna
jakość energii elektrycznej
electrical lighting
energy efficiency
power quality
Opis:
Energooszczędne urządzenia oświetleniowe od wielu lat są stosowane m.in. w gospodarstwach domowych, obiektach użyteczności publicznej, obiektach przemysłowych i oświetleniu ulicznym, a obowiązująca od 2011 r. Ustawa o efektywności energetycznej z pewnością ich stosowanie zintensyfikuje. Urządzenia te pobierają prąd odkształcony, a w niektórych przypadkach ? silnie odkształcony. Powoduje to różnorodne problemy instalacyjne. W pracy przeprowadzono analizę odkształcenia prądu pobieranego przez wybrane lampy i oceniono je z punktu widzenia wymagań odnośnie do jakości energii elektrycznej.
Energy efficient lighting is increasingly placed in residential, public and industrial indoors as well as in outdoor lighting. This process is assisted by Energy Efficiency Plan 2011 prepared by Euro Parliament. The load current of high efficient lamps usually is distorted and sometimes the distortion is remarkably high. This phenomenon can cause serious problems in the supply installation. This paper presents an analysis of current distortion in lamps circuits and evaluation of this distortion in terms of power quality standards.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 195-200
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy balance and quality in electric network powering IT objects
Autorzy:
Bednarek, K.
Kasprzyk, L.
Powiązania:
https://bibliotekanauki.pl/articles/97479.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
quality of energy
disturbance waveforms
higher harmonics
energy balance
reactive power compensation
Opis:
The paper deals with elements of issues regarding the impact of electromagnetic disturbances and electric energy management. The energy balance and tests of distortions of voltage and current waveforms in the power supply system of an IT facility such as a computer laboratory were carried out. The measurements covered current and voltage values, active power, reactive power and apparent power, power factor and THD (Total Harmonics Distortion) factor for voltage and current, waveforms and content of current and voltage harmonics in the facility under consideration. On top of this, effects of the UPS EVER POWERLINE power supply, provided with the reactive power compensation function (without connecting reactive compensation components) were tested in reference to the reactive power consumption by devices connected in parallel with the UPS to the electric network in the object. The analyses were carried out in terms of introducing rationalization of energy management and eliminating the impact of disturbances in systems covering power supply and energy receivers, that is, achieving technical (reliability of devices) and economic benefits (reduction in operational costs resulting from occurring power losses and in charges collected for consumption of electricity) in using large powered objects.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 113-126
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy Saving LED and CFL Lamps - Rated vs. True Power and Current Consumption
Energooszczędne lampy LED i CFL - dane znamionowe a rzeczywista moc i pobór prądu
Autorzy:
Mikoś, Zbigniew
Jachimski, Marcin
Bień, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/275834.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
LED lamps
CFL lamps
power measurement
energy measurement
power quality
lampy LED
lampy CFL
pomiar mocy
pomiar energii
jakość energii
Opis:
There is a very high availability of energy-saving lamps for consumer use on the market. Manufacturers, wanting to reach the widest possible range of customers, present on the packaging various data that do not inform the user about the real energy properties of the lamp. The authors have measured the energy parameters of several randomly selected LED and CFL lamps available in commercial networks and compared the obtained results with the parameters declared by the manufacturers.
Na rynku można zauważyć bardzo dużą dostępność lamp energooszczędnych przeznaczonych do zastosowań konsumenckich. Producenci, chcąc dotrzeć do jak najszerszego kręgu odbiorców, prezentują na opakowaniach różne dane, które nie informują użytkownika o rzeczywistych własnościach energetycznych lampy. Autorzy wykonali pomiary parametrów energetycznych kilku, przypadkowo wybranych lamp LED oraz CFL dostępnych w sieciach handlowych i porównali otrzymane dane pomiarowe z parametrami deklarowanymi przez producentów.
Źródło:
Pomiary Automatyka Robotyka; 2020, 24, 2; 51-58
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy Storage Control Strategy In a Prosumer System and Its Impact on the Distribution Grid
Strategia sterowania zasobnikiem energii w instalacji prosumenckiej i jej wpływ na pracę sieci dystrybucyjnej
Autorzy:
Urbanek, P.
Wasiak, I.
Pawełek, R.
Powiązania:
https://bibliotekanauki.pl/articles/396788.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
microsystem
prosumer installation
prosumer
electricity storage
energy storage control
electric power quality
mikrosystem
instalacja prosumencka
prosument
zasobnik energii elektrycznej
sterowanie zasobnikiem energii
jakość energii elektrycznej
Opis:
This paper discusses the operation of a low voltage prosumer system consisting of receivers and power sources. The system represents a hypothetical customer with variable energy input and output. The main technical issues related to the operation of such a system are presented. The application of an electric energy storage in the system for the purpose of managing the active power and providing the ancillary services relevant for the system's owner is discussed. The basic criterion of the system's performance is maximizing the use of the energy generated by the prosumer and maintaining the power factor at a desired level. The storage efficiency was tested using a simulation model developed in the PSCAD / EMTDC program. Sample simulation results are presented.
Artykuł dotyczy analizy pracy instalacji prosumenckiej niskiego napięcia składającej się z odbiorników oraz źródeł energii elektrycznej. Badana instalacja odwzorowuje hipotetycznego odbiorcę ze zmiennym obciążeniem oraz zmienną produkcją energii. Przedstawiono główne problemy techniczne związane z pracą takiej instalacji. Rozważono zastosowanie w instalacji zasobnika energii elektrycznej, którego celem jest zarządzanie mocą czynną oraz realizacja usług pomocniczych istotnych z punktu widzenia właściciela instalacji. Podstawowym kryterium pracy układu jest maksymalizacja wykorzystania energii produkowanej przez prosumenta oraz utrzymanie współczynnika mocy na żądanym poziomie. Skuteczność pracy zasobnika zbadano za pomocą modelu symulacyjnego opracowanego w programie PSCAD/EMTDC. Zaprezentowano przykładowe wyniki symulacji
Źródło:
Acta Energetica; 2017, 2; 213-221
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental and Practical Aspects of the use of Peat for Agriculture and Energy Aims
Autorzy:
Kowalczyk-Juśko, A.
Onuch, J.
Kościk, B.
Skowron, P.
Chołody, M.
Kosidło, A.
Rawski, J.
Powiązania:
https://bibliotekanauki.pl/articles/124083.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
peat
physical properties
energy value
power generation
improving soil quality
Opis:
The aim of this study was to evaluate physical and energetic parameters of peat. Utility of the peat in horticulture and power generation were also estimated. Peat was mined from the Klejniki deposit, (Hajnówka municipality, Podlaskie province) in the north-eastern part of Poland. It was found that peat can be used for power generation, in the air-dry moisture condition. Peat parameters are similar to lignite. It can also be suitable for the production of horticultural substrates and incorporated into soil as a component for improving physical and chemical properties. The examined peat fulfills the requirements of for agricultural applications.
Źródło:
Journal of Ecological Engineering; 2016, 17, 4; 138-142
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
From A Climate Action Plan (CAP) to a Microgrid: The SEEU Sustainability Concept Including Social Aspects
Autorzy:
Abazi, Alajdin
Iljazi, Iljas
Spirovski, Darko
Powiązania:
https://bibliotekanauki.pl/articles/1035820.pdf
Data publikacji:
2011
Wydawca:
Academicus. International Scientific Journal publishing house
Tematy:
Microgrid
Intelligent Microgrid
Climate Action Plan (CAP)
Energy Efficiency
Power Quality (PQ)
Green House Gases (GHG)
Carbon Footprint
Opis:
Following new global trends, the South East European University (SEEU), besides excellence in teaching and research, is committed to contributing to climate change effects and energy efficiency. SEEU will introduce a microgrid as a further step from the CAP towards energy sustainability. This paper presents the SEEU CAP and microgrid and also highlights benefits that are related to socio-economic conditions and the environment, including social aspects and sustainability.
Źródło:
Academicus International Scientific Journal; 2011, 04; 42-59
2079-3715
2309-1088
Pojawia się w:
Academicus International Scientific Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid synchronization and symmetrical components extraction with PLL algorithm for grid connected power electronic converters - a review
Autorzy:
Bobrowska-Rafał, M.
Rafał, K.
Jasiński, M.
Kaźmierkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200073.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase locked loop PLL
symmetrical component extraction
grid synchronization
grid-connected converter
smart grid
renewable energy sources (RES)
voltage dip
higher harmonics
power quality
Opis:
In this paper, a review of Phase Locked Loop (PLL) algorithms and symmetrical component extraction methods intended for grid-connected power electronic converters are presented. Proposed classification is based on voltage representation in three coordinates: natural (abc), stationary (alfa beta) and rotating coordinates (dq). The three selected algorithms are described in details: Dual Second Order Generalized Integrator (DSOGI-PLL), Dual Virtual Flux – both in stationary coordinates. The third one, in rotating dq coordinates, is Dual Synchronous Reference Frame PLL (DSRF-PLL). A comparison of PLL algorithms is presented. Also, selected experimental results are given to verify practical application of discussed algorithms.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 485-497
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość energii elektrycznej w punkcie identyfikacji w systemie elektroenergetycznym
Quality of electrical energy in the identification point in the power system
Autorzy:
Cieślik, S.
Powiązania:
https://bibliotekanauki.pl/articles/266663.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii elektrycznej
miara jakości energii
poziom jakości energii
quality of electric energy
power quality
electric power system
Opis:
W artykule przedstawiono uzasadnienie i propozycję definicji jakości energii elektrycznej w punkcie identyfikacji w systemie elektroenergetycznym. Punktem wyjścia było założenie, że energia elektryczna jest towarem w systemie elektroenergetycznym. Podano również definicje pojęć ściśle związanych z jakością energii elektrycznej w tych systemach.
The paper presents the justification and proposal of a definition for quality of electrical energy in the point of identification in the power system. The starting point is the assumption that electrical energy is a commodity in the power system. A definition of terms closely related to the quality of electrical energy in these systems is also presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 11-14
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalizacja źródeł zaburzeń napięcia w oparciu o zagregowane dane pomiarowe
Location of voltage disturbances sources based on aggregated measuring data
Autorzy:
Chmielowiec, Krzysztof
Wiczyński, Grzegorz
Firlit, Andrzej
Dutka, Mateusz
Barczentewicz, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/268160.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii elektrycznej
liczniki energii elektrycznej
zaburzenia napięcia
źródła zaburzeń
power quality
energy meters
power disturbances
disturbances sources
Opis:
W ostatnim czasie operatorzy elektroenergetycznych systemów dystrybucyjnych w Polsce zainstalowali w swoich sieciach kilkadziesiąt tysięcy bilansujących liczników energii elektrycznej wyposażonych, zgodnie z wymaganiami Urzędu Regulacji Energetyki, w funkcje pomiaru wskaźników jakości dostawy energii elektrycznej. Liczniki te, z racji swoich nowych funkcji pomiarowych oferują nowe możliwości oceny funkcjonowania oraz diagnostyki sieci dystrybucyjnych. Są też źródłem znaczącego wolumenu danych pomiarowych. Artykuł prezentuje możliwości wykorzystania zagregowanych wartości 10-minutowych pomiaru jakości energii elektrycznej, pochodzących z rozproszonych przyrządów pomiarowych (liczników i analizatorów) energii elektrycznej, w celu lokalizacji dominujących źródeł zaburzeń w elektroenergetycznej sieci dystrybucyjnej.
Recently, electricity distribution system operators in Poland have installed tens of thousands of balancing electricity meters, in accordance with the requirements of the Energy Regulatory Office, with the function of measuring the quality of electricity supply indicators. These meters, due to their new power quality measuring functions and significant volume, offer new possibilities in the assessment of functioning and diagnostics of power distribution systems. The article presents the possibility of using aggregated 10-minute power quality measurement data from electricity from dispersed electricity meters to locate dominant sources of disturbances in the power distribution network.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 53-56
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of the wind generation integration related power quality issues by energy storage
Autorzy:
Kook, K. S.
Liu, Y.
Atcitty, S.
Powiązania:
https://bibliotekanauki.pl/articles/262823.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
wind turbine generator (WTG)
wind farm
Power Quality Energy storage system (ESS)
power flow fluctuation
PSS/E
power system stability
Opis:
The wind power which has been expected to be a promising alternative energy source can bring new challenges when it is connected to the power grid due to the fluctuation nature of the wind and the comparatively new types of its generators. This paper illustrates a possible solution to mitigate these integration issues of the wind power by application of the energy storage to the wind farm in power systems focusing on its short-duration perspective. The simulation model for the Energy Storage System (ESS) connected to the wind farm is implemented using the Power System Simulator for Engineering(PSS/E) which is one of the most widely used program for the power system analysis in US. Employing a sample power system, the control effect of the ESS for mitigating the wind generation related power quality issues by suppressing the power flow fluctuation of the wind farm, and improving power system stability is validated. The counteracting effect of the ESS in the wind farm to the disturbance on the grid is also shown.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 77-82
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies