Tytuł:
Low-rank coals in Poland: prospection - mining - progress
Autorzy:
Kasiński, J. R.
Powiązania:
https://bibliotekanauki.pl/articles/1204914.pdf
Data publikacji:
2002
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
lignite resources
coal quality
power production
coal mining
by-products
perspectives
Tertiary
Polska
Opis:
Low-rank coal resources occur in Poland commonly within Tertiary deposits. Miocene coal-bearing deposits are most substantial; resources related to them are located in the eight lignite-bearing regions with total quantity above 40 bill. Mg. Origin of major lignite deposits are tectonic and subrosional. Coal of the 4 economic seams belongs to the hypolignite group and is of rather good quality. Lignite in Poland is exploited from more than two hundred years. Recently, four large mines operate in central Poland (Adamów, Bełchatów and Konin) and south-eastern Poland (Turów). They produce about 60 mil. Mg of lignite per year. Almost whole coal is used as energy resource for five mouth-mine power plants, producing ca. 52 mil. MWh annually, and covering ca. 40% of Poland recent requirements. This energy is the cheapest one in Poland. Small amounts of lignite cover local requirements, and are used for production of valuable fertilisers. Also by-products: ceramic and kaolin clays, bentonite, quartz sand and aggregate, and bog-lime are selectively exploited. The Legnica region is regarded as the most probable new operating mining area in the future. Complex technologies applied recently allow to substantially decrease environmental impact of mining, and the reclaimed areas are returned to agriculture and forestry. Final excavations are used as waste storage areas, and part of them is transformed into scenic lakes. Proper environmental protection and reclamation procedures are extremely important, because future of lignite mining development depends on its social acceptance.
Źródło:
Polish Geological Institute Special Papers; 2002, 7; 17-30
1507-9791
Pojawia się w:
Polish Geological Institute Special Papers
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Weryfikacja doświadczalna analizatora jakości energii elektrycznej na statku m/s "Horyzont II"
Experimental verification of electrical power quality analyser on the ship m/s "Horyzont II"
Autorzy:
Tarasiuk, T.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157618.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
weryfikacja doświadczalna analizatora jakości
analizator jakości energii elektrycznej
experimental verification of electrical power
electrical power quality analyser
Opis:
W pracy przedstawiono strukturę i model fizyczny analizatora jakości energii elektrycznej opracowanego dla potrzeb energetyki okrętowej. Wspomniany model zrealizowany został z wykorzystaniem procesorów sygnałowych i przeszedł z wynikiem pozytywnym badania swoich właściwości w warunkach laboratoryjnych.Ostatecznej weryfikacji walorów użytkowych modelu dokonano na statku szkolno-badawczym Akademii Morskiej w Gdyni m/s "Horyzont II". W pracy przedstawiono wybrane przykłady przeprowadzonych badań.
Ii the paper the structure and physical model of the ships electrical power quality analyser has been presented. The above - mentioned model is based on the digital signals processing and it has been positively tested under the laboratoty conditions. The final verification of the operational properties of this device has been carried out on Gdynia Maritime University training ship m/v "Horizont II".
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 1, 1; 31-36
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procedury zapewnienia jakości działalności remontowej i inwestycyjnej urządzeń elektroenergetycznych
Procedures of Quality Assurance in Electrical Power Equipment Repairs and Investments
Autorzy:
Dąbrowska-Kauf, G.
Powiązania:
https://bibliotekanauki.pl/articles/360251.pdf
Data publikacji:
2004
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
urządzenia elektroenergetyczne
system zarządzania jakością
normy serii ISO 9000-2000
procedury zapewnienia jakości
EXPLO-SHIP 2004
electrical power equipment
quality management system
ISO 9000-2000 series
procedures of assuring quality
Opis:
W przedsiębiorstwach sektora energetycznego istnieje konieczność wdrożenia systemów zarządzania jakością w celu zapewnienia konkurencyjności na europejskim rynku energii elektrycznej. W artykule omówiono zasady tworzenia dokumentacji systemu jakości zgodnie z wymaganiami normy serii ISO 9000 -2000, a szczególnie opracowywania procedur zapewnienia jakości działalności remontowej i inwestycyjnej urządzeń elektroenergetycznych w przedsiębiorstwie sektora energetycznego.
Power industry enterprises have to implement quality management systems in order tobe competitive on the European power market. The article outlines the establishment of quality system documentation according to standards of ISO 9000 - 2000 series, in particular the compiling of procedures of quality assurance in electrical power equipment repairs and investments in the power industry.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2004, 1 (73); 161-170
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza toru sygnałowego flickermetru dla napięcia sieciowego zmodulowanego przebiegiem harmonicznym
Analysis of flickermeter signal chain for supply voltage modulated with harmonic waveform
Autorzy:
Wiczyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/152095.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jakość napięcia
flickermeter
charakterystyka amplitudowo-częstościowa
wskaźnik Pst
power quality
amplitude-frequency characteristics
Pst parameter
Opis:
Normatywną miarą uciążliwości wahań napięcia są wskaźniki długookresowego Plt i krótkookresowego Pst migotania światła. Wartości wskaźników określane są na podstawie sygnału wyjściowego otrzymywanego z układu "Flickermetru". Tor sygnałowy tego układu jest na tyle złożony, że wyznaczenie wartości wyjściowych nie jest proste. Uznano więc za celowe przeanalizowanie kolejnych etapów przetwarzania dla harmonicznej zmienności wartości skutecznej napięcia. W wyniku uzyskano pełną charakterystykę amplitudowo-częstościową zawierającą fragmenty nie objete normalizacją normatywną.
Normalized measures of disturbances caused by light flickers resulting fromvoltage fluctuations are factors of the long-term and short-term light flickers, respectively, determinated by the flickermeter output signal. Because the signal circuit of this device is very complex, the following steps of processing were analyzed. For this purpose, the simplest case the supply voltage modulation with a harmonic signal has been selected. A segment function is used in processing realized with a simplified flickermeter circuit. The following effects of performed processing are described. A full amplitude frequency characteristic for a range over 50 Hz, which is often omitted in the literature, has been obtained.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 9, 9; 30-33
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Vienna rectifier
Autorzy:
Radomski, Cz.
Powiązania:
https://bibliotekanauki.pl/articles/262643.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power electronics
electric power quality
PFC rectifiers
improving THD(i)
Opis:
It is common to find the inexpensive but robust electric power rectification method to lullil the demands of clean power conversion [1-12]. The Vienna rectifier structure [1] is one of the hopeful construction to fulfil these demands. It may be classified as the Clean Power Converter. It lets us obtain PFC rectification in simpler than the PWM converter system. The \ inina rectifier has three control points. In addition the Vienna rectifier is the three voltage level system with less current ripples than in the case of the PWM converter. However, it has some disadvantages. The Vienna rectifier system is an unidirectional converter. It can function onlv in the rectifier mode, the working in the inverter mode is impossible and the generation of the reactive power is strongly restricted. Usually the Vienna rectifier is controlled on the basis of the direct current control method [4,5,6]. However, this method is not perfect because it lets the improper control sequences appears. In this paper the mathematical model of the Vienna rectifier is derived. The voltage space vectors and their dependencies to the phase currents are denned. The range of the phase displacement angle and the maximum voltage space vector module v. phase displacement angle is drawn out for the case of the sinusoidal space vector modulation. The drawn out relations are proven by simulation results.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 49-56
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Developments of power quality studies in electric transportation system
Autorzy:
Burchi, G.
Foiadelli, F.
Zaninelli, D.
Powiązania:
https://bibliotekanauki.pl/articles/262769.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
electric transportation
traction converter
probabilistic methods
Opis:
The paper deals with the update studies on Power Quality for electric traction systems. Probabilistic methods of analysis are presented both for the supply lines and the rolling stocks. Simulation software tools are created for disturbance propagation studies and examples of application are reported with reference to the Italian railway case.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 107-112
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of voltage unbalance in power systems supplying high speed railway
Autorzy:
Burchi, G.
Lazaroiu, C.
Golovanov, N.
Roscia, M.
Powiązania:
https://bibliotekanauki.pl/articles/262785.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
high speed railway
voltage unbalance
power quality
Opis:
The electric high speed railway loads supplied by the three phase power system represent one of the main sources of voltage unbalance perturbation in the grid. The power system configuration and (he load conditions influence the degree of this power quality perturbation. The present paper deals with the problems raised by the practical determination of the voltage unbalance factor in conformity with the European and IEEE standards. The procedure for identifying a vulnerability area in which the voltage unbalance presents values that exceed the standard limits is elaborated and comparison on the use of the two mentioned set of standards is performed. A case study referred to the 63 buses CJGRE network analyzed in the paper gives rise to interesting comments and discussion.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 113-119
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of voltage flicker by superconducting synchronous Condenser (SUPERVAR)
Autorzy:
Tsai, S. S.
Liu, Y.
Ingram, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/262647.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
superconductivity
synchronous condenser
voltage flicker
power quality
Opis:
Voltage flicker caused by the electric arc furnace (EAF) and the mitigation using the superconducting synchronous condenser (SuperVAR) by the American Superconductor Corp. are considered in this paper. The modeling of EAF, SuperVAR and the system used are discussed. Fast reactive power support to reduce voltage flicker problem by an EAF is desirable. The voltage fluctuation amplitude is used as an index to evaluate the effectiveness of SuperVAR for two different MVar levels. At the PCC (point of common coupling) bus, the application of the SuperVAR can improve the voltage flicker by 6% and 19% by applying DC1A type and AC4A type exciter to the SuperVAR. With an DC1A type exciter, the SuperVAR can output only between +1 and -2 MVAR and with an AC4A type exciter the SuperVAR can provide its full rated power (8MVAR) to the system, making the voltage flicker a less severe.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 39-44
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sampled method of active power filter control. Part 1
Autorzy:
Szromba, A.
Powiązania:
https://bibliotekanauki.pl/articles/262771.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
shunt active power filter
power factor
power quality
Opis:
The aim of the paper is to demonstrate how to use sampled method of control of a shunt active power filter to maintain invariable power of a supplying voltage source, even though the supplied load varies randomly. The definition by S. Fryze of load current components is used as a basis for the construction of a family of shunt active power filters. The under discussion family of filters is designed to work synchronically with a time period T. The period T may be regulated in some range. The distinctive property of these filters is maintaining non-deformed source current in every one individually considered period T. Main features of the family of filters are described in the first part of the paper, which is devoted to DC circuit. Then in the second part, the results, which are obtained in DC circuit, are implemented to a single- and then to a three-phase circuit. Additionally, some new features, which may be applied only for AC circuit, are discussed in the second part. All the presented waveforms are obtained using computer simulation tools.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 91-98
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity of electrical equipment to voltage sags and short interruptions : recommendations for testing
Autorzy:
Djokic, S.
Milanovic, J. V.
Powiązania:
https://bibliotekanauki.pl/articles/262651.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
voltage sags
short interruptions
sensitivity of equipment
testing of equipment
Opis:
General testing procedures for testing different types of electrical equipment against various types of voltage sags and short interruptions are proposed and described in this paper. The recommendations for testing are discussed with respect to a number of sag and interruption parameters, non-ideal voltage supply characteristics, type of equipment, operating/loading conditions of the equipment and multiplicity of the malfunction criteria of the equipment. Presented analysis is illustrated.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 17-32
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of a neutral wire filter inductor in a three-leg four-wire active power filter
Autorzy:
Pettersson, S.
Salo, M.
Tuusa, H.
Powiązania:
https://bibliotekanauki.pl/articles/262723.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
four-wire system
power quality
vector control
control delay compensation
performacnce
Opis:
Three-leg active power filter topology is the cost effective solution implementing a four-wire active power filter but it has some disadvantages compared to four-leg topology. The lack of a neutral wire filter inductor results in larger filter losses and therefore the efficiency of the topology is impaired. The neutral wire filter inductor is typically used with the four-leg four-wire active power filter topology and significantly reduces switching frequency current ripple. In this paper the suitability of a neutral wire filter inductor for the three-leg topology is studied. The performance of three-leg topology with a neutral wire filter inductor is studied through computer simulations and laboratory tests. The results indicate that the use of the neutral wire filter inductor clearly improves the performance of three-leg topology.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 83-89
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aplikacja transformacji SPWVD w pomiarach jakości energii elektrycznej z wykorzystaniem procesora DSP
The application of SPWVD transformation in power quality measurements with DSP processor use
Autorzy:
Szmajda, M.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/153262.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jakość energii elektrycznej
transformacja Wignera-Ville'a
procesor DSP
power quality
Wigner-Ville transformation
DSP processor
Opis:
W artykule przedstawiono badania dotyczące zastosowania wygładzonej pseudo-transformacji Wignera-Ville'a w pomiarach wybranych parametrów jakości energii elektrycznej. Przeprowadzono analizę wyników badań transformacji najczęściej występujących zakłóceń sygnału elektroenergetycznego takich jak: harmoniczne, wolne (zapady, podwyższenia napięcia) i szybkie zmiany napięcia (fliker) oraz przepięcia przejściowe sinusoidalne eksponencjalnie tłumione. "Sygnałem elektroenergetycznym" autorzy nazywają sygnał sinusoidalny o częstotliwości 50Hz oraz nominalnej wartości skutecznej 230V, mający na celu modelować przebieg napięcia sieci zasilającej niskiego napięcia. Zaprezentowano również aplikację metody w systemie mikroprocesorowym zbudowanym w oparciu o procesor sygnałowy DSP.
The paper presents the research concerning the Smoothed Pseudo Wigner-Ville Distribution in power quality parameters measurement. Also, some investigations of SPWVD results of most frequently appearing disturbances in the power network were done. The disturbances include harmonics, slow (sags, swells) and fast voltage changes (flicker) and fast transients. The application of the method in DSP microprocessor system were presented.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 10, 10; 70-72
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control circuit for series active power filters based on programmable logic devices
Autorzy:
Supronowicz, H.
Olszewski, A.
Gawiński, H.
Powiązania:
https://bibliotekanauki.pl/articles/262739.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power electronics
active power filter
power quality
Opis:
This paper describes a control circuit for the active power filters working with three-phase AC power line. It describes logic circuitries as well as laboratory test results. The control circuit was realized with programmable logic devices, fast analog-to-digital and digital-to-analog converters. Proposed system working with open-loop control, it allows significantly simplifying its logic structure. Programmable logic devices do simultaneously a few independent tasks, so a control algorithm can be performing fast, improving considerably compensation dynamic. This paper includes results of laboratory tests of the active power filter consisted of proposed control circuit and a voltage-source converter.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 21-25
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka izolowanego systemu elektroenergetycznego na przykładzie jednostki pływającej
Diagnostics of isolated electrical power system on example of the ship
Autorzy:
Mindykowski, J.
Tarasiuk, T.
Szmit, E.
Czarkowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/327684.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
izolowany system elektroenergetyczny
jakość
energia elektryczna
zniekształcenia sygnałów
isolated electrical power system
electrical power quality
waveform distortions
Opis:
Publikacja omawia zaawansowane techniki diagnostyczne wykorzystywane do pomiarów jakości energii elektrycznej w izolowanych systemach elektroenergetycznych stosowanych na jednostkach pływających, małych wyspach, terenach zajętych przez strony walczące itp. W publikacji zawarto obserwacje poczynione podczas dotychczasowej współpracy oraz badań prowadzonych na trzech różnych obiektach pływających, z których jeden był tzw. all electric ship, gdzie podstawową część odbiorników energii elektrycznej stanowiły obwody nieliniowe, posiadające zasadniczy wpływ na parametry jakości energii elektrycznej.
Publication treats of advanced diagnostic technologies used for electrical power quality measurements in isolated electrical power systems, applied on ships, small islands, territories occupied by fighting sides, etc. Publication includes observations made during the present cooperation and tests carried out onboard three different ships, which one of them was all electric ship, where main part of power consumers were non-linear circuits having principle influence on the parameters of electrical power quality.
Źródło:
Diagnostyka; 2006, 2(38); 171-176
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Investigations of the Upqc Arrangement
Autorzy:
Benysek, G.
Powiązania:
https://bibliotekanauki.pl/articles/262602.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
power flow control
harmonics compensation
reactive power compensation
Opis:
This paper presents the fundamental properties and dependences describing the UPQC (Unified Power Quality Conditioner) arrangements. The UPQC devices simultaneously permit to fulfill the following functions: voltage and current harmonics compensation, network voltage and load current symmetrization as well as network voltage stabilization and power flow control. The selected results of the experimental investigations conducted on the small power laboratory model have been described. Applied method for DC link capacity selection was talked over in details and confirmed with experimental results. Results of experimental investigations, including operation of the UPQC arrangement in case of thyristor rectifier load were also introduced.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 27-34
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies