Tytuł:
Properties of the power conditioning system with a five-level cascaded converter and supercapacitor energy storage
Autorzy:
Zygmanowski, M.
Grzesik, B.
Michalak, J.
Powiązania:
https://bibliotekanauki.pl/articles/200041.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascaded H-bridge multilevel converters
power conditioning system
power quality
Opis:
The paper presents the power conditioning system (PCS) with a five-level cascaded H-bridge converter and supercapacitor energy storage. The paper focuses on such properties of a power electronic converter as its operation, power losses, start-up as well as the DC-link voltage balancing method and controller. A laboratory model of the PCS and its test results have been presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 525-540
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wydajności obliczeniowej systemu pomiarowego jakości energii elektrycznej opartego na urządzeniu embedded BeagleBoard z systemem operacyjnym Linux
An efficiency analysis of the power quality monitoring system based on BeagleBoard embedded with Linux operating system
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/274929.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
analiza sygnałów
jakość energii elektrycznej
metoda Prony’ego
urządzenie wbudowane
przetwarzanie sygnałów
signal analysis
power quality
Prony's method
embedded system
signal processing
Opis:
W artykule przedstawiono możliwości zastosowania niskobudżetowego modułu embedded BeagleBoard na bazie procesora OMAP firmy Texas Instruments, działającego pod kontrolą systemu Linux, do budowy zaawansowanego urządzenia pomiarowego parametrów jakości energii elektrycznej. W artykule przeanalizowano czasy obliczeń złożonych algorytmów przetwarzania sygnałów na przykładzie metody Prony'ego, mogących mieć zastosowanie przy wyznaczaniu parametrów jakości energii elektrycznej. Czasy te będą porównane z czasami obliczeń dla typowych urządzeń klasy PC o architekturze 8086. Dodatkowo zostaną pokazane możliwości dołączenia do systemu urządzeń peryferyjnych oraz sond pomiarowych.
The article show the possibilities of use of the low cost BeagleBoard embedded system based on Texas Instruments OMAP processor with Linux operating system used for advanced power quality monitoring system. The authors show analysis results of the required time computation for presented advanced signal analysis methods like Prony's method, which can be used for power quality parameters estimation. The results were compared with computations made for PC standard computers, with x86 architecture. Additional, the article show possibility of peripheral devices connections to the presented system.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 50-52
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prony’s method with reduced sampling - numerical aspects
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/220676.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
signal analysis
harmonic analysis
signal processing
power quality
Opis:
This paper presents a new modification of the least-squares Prony’s method with reduced sampling, which allows for a significant reduction in the number of the analysed signal samples collected per unit time. The specific combination of non-uniform sampling with Prony’s method enables sampling of the analysed signals at virtually any average frequency, regardless of the Nyquist frequency, maintaining high accuracy in parameter estimation of sinusoidal signal components. This property allows using the method in measuring devices, such as for electric power quality testing equipped with low power signal processors, which in turn contributes to reducing complexity of these devices. This paper presents research on a method for selecting a sampling frequency and an analysis window length for the presented method, which provide maximum estimation accuracy for Prony’s model component parameters. This paper presents simulation tests performed in terms of the proposed method application for analysis of harmonics and interharmonics in electric power signals. Furthermore, the paper provides sensitivity analysis of the method, in terms of common interferences occurring in the actual measurement systems.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 521-534
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short time algorithm of power waveforms fundamental harmonic estimation with use of pronys methods
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221769.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
Prony's method
harmonics
measurements
Opis:
This paper presents an example of practical use of Prony's method for monitoring of power waveform fundamental harmonic fluctuations, which is required for the analysis of window synchronizations in frequency analyses in power monitoring systems. The example presented offers verification of the authors' theoretical considerations published earlier in articles about Prony's method and its opportunities for practical use for real life signals. The investigations shown are based on the least squares Prony's method, which, in connection with digital filtrations, enables estimations of fundamental frequency at the rate of even tens of times per one fundamental harmonic period.
Źródło:
Metrology and Measurement Systems; 2011, 18, 3; 371-378
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable-frequency Prony method in the analysis of electrical power quality
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221630.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
Prony method
harmonics
measurements
Opis:
The article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal, are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The proposed modification of least squares Prony method is based on introduction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 39-48
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modem PLC a jakość energii
Modem PLC and Power Quality
Autorzy:
Zbydniewski, Ł.
Bień, A.
Powiązania:
https://bibliotekanauki.pl/articles/152719.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jakość energii
kanał PLC
transmisja PLC
power quality
PLC channel
PLC transmission
Opis:
W artykule omówiono obowiązujące aktualnie standardy oraz regulacje prawne w zakresie technologii PLC (ang. Power Line Communications). Scharakteryzowano w skrócie kanał transmisyjny, jaki tworzą zwykłe przewody instalacji elektrycznej. Przedstawiono wyniki pomiarów w sieci energetycznej budynku wielomieszkaniowego dużego polskiego miasta. W pomiarach wykorzystano modemy PLC.
In this article present Power Line Communications (PLC) technology standards and regulations were examined. Short characterization of PLC channel made from standard power lines was presented. Results of measurements in a multi-apartment bulding in Poland were presented. In researches were also utilized the HomePlug 1.0 standard PLC mode.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 142-145
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of supra-harmonics through signal processing methods in smart grids
Autorzy:
Yalcin, T.
Ozdemir, M.
Kostyla, P.
Leonowicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/136245.pdf
Data publikacji:
2017
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
ensemble empirical mode decomposition
power quality
Fourier analysis
Short Time Fourier Transformation
Opis:
Nowadays supra-harmonic distortion studies are gaining attention day by day in power quality research area. When handling communication systems especially Power Line Carrier (PLC) systems in frequency range 2-150 kHz, they are suitable for causing electromagnetic interference (EMI) to other systems. This study shows results of analysis employing advanced method called ensemble empirical mode decomposition (EEMD) to describe supra-harmonic distortion. Unlike the traditional method (short time fourier transform-STFT), EEMD gives extensive representation for supra-harmonic components.
Źródło:
Transactions on Environment and Electrical Engineering; 2017, 2, 2; 80-85
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pattern Recognition Methods for Detecting Voltage Sag Disturbances and Electromagnetic Interference in Smart Grids
Autorzy:
Yalcin, T.
Ozdemir, M.
Powiązania:
https://bibliotekanauki.pl/articles/136160.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
C4.5 decision trees
electromagnetic interference
feature extraction
hilbert huang transform
power quality disturbance
smart grids
support vector machines
Opis:
Identification of system disturbances, detection of them guarantees smart grids power quality (PQ) system reliability and provides long lasting life of the power system. The key goal of this study is to find the best accuracy of identification algorithm for non-stationary, non-linear power quality disturbances such as voltage sag, electromagnetic interference in smart grids. PQube, power quality and energy monitor, was used to acquire these distortions. Ensemble Empirical Mode Decomposition is used for electromagnetic interference reduction with first intrinsic mode function. Hilbert Huang Transform is used for generating instantaneous amplitude and instantaneous frequency feature of real time voltage sag power signal. Outputs of Hilbert Huang Transform is intrinsic mode functions (IMFs), instantaneous frequency (IF), and instantaneous amplitude (IA). Characteristic features are obtained from first IMFs, IF, and IA. The six features—, the mean, standard deviation,skewness, kurtosis of both IF and IA are then calculated. These features are normalized along with the inputs classifiers. The proposed power system monitoring system is able to detect power system voltage sag disturbances and capable of recognize electromagnetic interference component. In this study based on experimental studies, Hilbert Huang Transform based pattern recognition technique was used to investigate power signal to diagnose voltage sag and in power grid. Support Vector Machines and C4.5 Decision Tree were operated and their achievements were matched for precision and CPU timing. According to the analysis, decision tree algorithm without dimensionality reduction produces the best solution.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 3; 86-93
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Hybrid Filtering Solution for Marine Electric Network
Autorzy:
Xu, X - Y.
Mindykowski, J.
Chen, C. L. P.
Powiązania:
https://bibliotekanauki.pl/articles/259582.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
electrical engineering
marine vehicle power systems
power system harmonics
power system measurements
quality control
Opis:
This paper presents a Hybrid APF/PFC/PPF Circuit (active power filtering and power factor correction circuit aided by shunt passive filter) for harmonic suppression and power factor correction in a marine electric network. By employing the proposed hybrid circuit, marine electric power network voltage and current can be maintained as being sinusoidal, and the power factor is close to 1. The effectiveness of the proposed method that is applied to a marine electric network is demonstrated through a simulation experiment. The results show that the expected performances are achieved.
Źródło:
Polish Maritime Research; 2010, 2; 72-78
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thirty-six pulse rectifier scheme based on zigzag auto-connected transformer
Autorzy:
Xiao-Qiang, Ch.
Chun-Ling, H.
Hao, Q.
Min, L.
Powiązania:
https://bibliotekanauki.pl/articles/140726.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
autotransformer
harmonic suppression
multipulse rectifier
power quality
Opis:
In this paper, a low kilo-volt-ampere rating zigzag connected autotransformer based 36-pulse rectifier system supplying vector controlled induction motor drives (VCIMD) is designed, modeled and simulated. Detailed design procedure and magnetic rating calculation of the proposed autotransformer and interphase reactor is studied. Moreover, the design process of the autotransformer is modified to make it suitable for retrofit applications. Simulation results confirm that the proposed 36-pulse rectifier system is able to suppress less than 35th harmonics in the utility line current. The influence of load variation and load character is also studied to demonstrate the performance and effectiveness of the proposed 36-pulse rectifiers. A set of power quality indices at AC mains and DC link are presented to compare the performance of 6-, 24- and 36-pulse AC-DC converters.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 117-132
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of a new capacitor bank installation on power quality parameters : an industrial case study
Wpływ przyłączenia nowej baterii kondensatorów na jakość energii elektrycznej : analiza wybranego przypadku przemysłowego
Autorzy:
Wysocki, W.
Powiązania:
https://bibliotekanauki.pl/articles/268691.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii elektrycznej
pomiary
moc bierna
power quality
measurements
reactive power
Opis:
This paper deals with the results of three phase measurements of power quality parameters. The measurements were executed in order to match the new capacitor bank with the operating conditions of a supply station in a small factory near Cracow. The measurements were conducted under rated voltage (three-phase, 230/400V) in the LV switchgear. The main objective of the analysis was to assess power quality during long-term operating conditions both before and after the installation of a new capacitor bank. The analysis also aimed to check the influence of the capacitor bank on power quality and identifying the quantitative benefits of reactive power compensation.
Dokument traktuje o wynikch trójfazowych pomiarów parametrów jakości energii. Pomiary zostały wykonane w celu dostosowania nowej baterii kondensatorów do warunków pracy stacji zasilającej małą fabrykęi w pobliżu Krakowa. Pomiary były wykonywane przy napięciu znamionowym 230/400V w rozdzielnicy głównej nn. Głównym celem przedstawionej analizy wyników jest ocena jakości energii podczas długotrwałych warunków pracy przed i po instalacji nowej baterii kondensatorów, jak również, sprawdzenie jej wpływu na tę jakość energii elektrycznej i przekonanie się o ilościowych korzyściach płynących z kompensacji mocy biernej.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 165-168
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid Voltages Sensorless Control of the PWM Rectifier with Active Filtering
Autorzy:
Wojciechowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/262568.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
active filters
power quality
predictive control
estimation
techniques
Opis:
The paper presents structure and experimental results of the control system of the PWM rectifier with active filtering function. Proposed control system was designed for maximum filtering performance in steady state. This task is realized by predictive algorithms applied for both control as well as calculation of grid currents. Accuracy of these algorithms strongly depends on precise information about future samples of equivalent electromotive force of the grid, which is in general distorted and unbalanced. For this purpose, a novel estimator and predictor is proposed. The control of DC voltage is realized with application of variable gain PI controller. It ensures high dynamics in transient states and low gain for steady state oscillations of DC voltage. Proposed control system is AC voltages sensor less and has excellent active filtering performance, even at presence of grid voltage distortions.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 35-43
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywny pomiar i analiza jakości energii elektrycznej
Effective measurement and analysis of quality electrical energy
Autorzy:
Włas, M.
Powiązania:
https://bibliotekanauki.pl/articles/267292.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii
pomiary
rezonans równoległy
sieci energetyczne
power quality
measurements
resonance
power networks
Opis:
W artykule przestawiono stan prawny oraz parametry określające jakość energii elektrycznej (JEE). Przedstawiono dwa rodzaje urządzeń do pomiaru JEE – stacjonarne analizatory i urządzenia przenośne. Wskazano konieczność ciągłego monitoringu wskaźników JEE. Artykuł przedstawia cztery przypadki pomiaru parametrów energii elektrycznej, gdzie doszło do awarii systemu zasilania lub baterii kondensatorów czego przyczyną było pogorszenia JEE. Dla opisanych przypadków przedstawiono wyniki pomiarów i wyjaśniono przyczyny awarii.
The article resetting legal status and parameters defining the quality of electricity (QoE). There are two types of measurement devices JEE - stationary analyzers and portable devices. It indicated the need for continuous monitoring of indicators QoE. This article presents four cases parameter measurement of electricity, where there was a failure of the power supply or capacitor Bank. Author present the results of measurements and explains the cause of the failure or reactive power appear.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 89-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza toru sygnałowego flickermetru dla napięcia sieciowego zmodulowanego przebiegiem harmonicznym
Analysis of flickermeter signal chain for supply voltage modulated with harmonic waveform
Autorzy:
Wiczyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/152095.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jakość napięcia
flickermeter
charakterystyka amplitudowo-częstościowa
wskaźnik Pst
power quality
amplitude-frequency characteristics
Pst parameter
Opis:
Normatywną miarą uciążliwości wahań napięcia są wskaźniki długookresowego Plt i krótkookresowego Pst migotania światła. Wartości wskaźników określane są na podstawie sygnału wyjściowego otrzymywanego z układu "Flickermetru". Tor sygnałowy tego układu jest na tyle złożony, że wyznaczenie wartości wyjściowych nie jest proste. Uznano więc za celowe przeanalizowanie kolejnych etapów przetwarzania dla harmonicznej zmienności wartości skutecznej napięcia. W wyniku uzyskano pełną charakterystykę amplitudowo-częstościową zawierającą fragmenty nie objete normalizacją normatywną.
Normalized measures of disturbances caused by light flickers resulting fromvoltage fluctuations are factors of the long-term and short-term light flickers, respectively, determinated by the flickermeter output signal. Because the signal circuit of this device is very complex, the following steps of processing were analyzed. For this purpose, the simplest case the supply voltage modulation with a harmonic signal has been selected. A segment function is used in processing realized with a simplified flickermeter circuit. The following effects of performed processing are described. A full amplitude frequency characteristic for a range over 50 Hz, which is often omitted in the literature, has been obtained.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 9, 9; 30-33
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka sinusoidalnych wahań napięcia w sieci elektroenergetycznej z wykorzystaniem wskaźnika ΔV10
Diagnostics of sinusoidal voltage fluctuations in a power grid using the ΔV10 index
Autorzy:
Wiczyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/152302.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jakość energii elektrycznej
modulacja amplitudy
modelowanie
wskaźnik ΔV10
amplitude modulation
modelling
power quality
ΔV10 index
Opis:
W artykule omówiono definicję wskaźnika ΔV10. Zaproponowano schemat blokowy miernika ΔV10 i wyznaczono jego równanie przetwarzania dla sinusoidalnej zmienności napięcia. Porównano wartości wskaźników ΔV10 i Pst. Prezentując wyniki porównań obu miar przybliżono możliwości diagnostyczne wskaźnika ΔV10. Odwołując się do zamieszczonych zależności ΔV10, Pst i ƒm wykazano, że dla zmienności napięć występujących w sieciach elektroenergetycznych niemożliwe jest przeliczanie jednej miary do drugiej.
The ΔV10 index is a measure of voltage fluctuations in power grids proposed by the Japanese CRIEPI Institute [1] and used all over the Far East countries. European standards prefer Pst and Plt indicators in voltage fluctuation measurements [11]. The ΔV10 and Pst/Plt are different in terms of the characteristics of measurement signal chains [6]. Therefore the measures may be characterized by different diagnostic capabilities. This may lead to the situation where some receivers may be described as faultless while voltage fluctuations are acceptable for one measure and may be described as faulty with the voltage fluctuations being unacceptable for the other measure. On the other hand, some level of uncertainty may appear as the influence of a receiver may be classified as obnoxious with the use of one measure and not-obnoxious with the use of the other. The paper includes analytical determination of the ΔV10 index value dependency on the voltage fluctuation reproduced with a sinusoidal amplitude modulation (Eq. (2)). The calculations have been made for the assumed signal chain model of a ΔV10 index measuring instrument (Fig. 3). The values of ΔV10 and Pst indexes at a given sinusoidal voltage fluctuation have been compared (Figs. 4-6). On the basis of the obtained ΔV10 and Pst dependencies on ƒm it has been assumed that for the voltage fluctuations present in power grids of unknown type and frequency it is impossible to convert one measure into the other.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 425-428
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies