Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power model" wg kryterium: Temat


Tytuł:
A Comparative Analysis of the Power of Selected European Countries. The Economic Determinants
Autorzy:
Paluch, Alicja
Spustek, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/1807597.pdf
Data publikacji:
2021-09-30
Wydawca:
Wyższa Szkoła Bezpieczeństwa Publicznego i Indywidualnego Apeiron w Krakowie
Tematy:
power of a state
economic power-building factors
a state power model
Opis:
The ever-increasing need for in-depth analysis and quantification of the national power, in particular ‘hard’ and ‘soft’ power-generating factors as well as difficulties in identifying a comprehensive and effective method for scientific determination of the national power, have given rise to research in the indicated scientific issues within this article. The presented considerations aim to define the assumptions for a descriptive sub-model that would enable a comparison of Poland’s power in the economic sphere (which is a component of the non-military sphere) with the power of selected European countries. The research hypothesis is that, among the variety of descriptive variables in the economic sphere of the national power, there is a subset of mutually independent variables, at the same time strongly correlated with the national power, which make it possible to define assumptions for the sub-model of the national power. The steps of the research procedure were carried out using the method of system analysis (multi-criteria comparative analysis) and statistical analysis. The research activities undertaken have shown that the factors that are strongly correlated with the national power in the economic area of the European countries adopted for the analysis are: dynamics of industrial production, private sector credit flows and economic freedom index. The comparative analysis carried out demonstrates that the greatest increase in the economic power in the analysed period took place in Germany (0.68). Slightly smaller growth was recorded in the Czech Republic (0.62) and Poland (0.60), while the lowest value of increase was in Romania (0.23). The conducted qualitative comparative analysis of the economic power of selected European countries allowed to conclude that the independent variables identified are crucial for the formation of the economic power of the analysed countries. At the same time, a fairly strong position of the Czech Republic and Poland in relation to the economic power of Germany was found. The performed quantification of the economic power of the European countries provides a basis for the correct determination of changes in the power distribution of political units, assessment of the power and resources held by the state.
Źródło:
Security Dimensions; 2021, 37(37); 22-42
2353-7000
Pojawia się w:
Security Dimensions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A dynamic model as a tool for design and optimization of propulsion systems of transport means
Autorzy:
Peruń, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/11542694.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
dynamic model
gear design
power transmission system
model dynamiczny
konstukcja przekładni
układ napędowy
Opis:
Designing power transmission systems is a complex and often time-consuming problem. In this task, various computational tools make it possible to speed up the process and verify a great many different solutions before the final one is developed. It is widely possible today to conduct computer simulations of the operation of various devices before the first physical prototype is built. The article presents an example of a dynamic model of power transmission systems, which has been developed to support work aimed at designing new and optimizing existing systems of that type, as well as to help diagnose them by designing diagnostic algorithms sensitive to early stages of damage development. The paper also presents sample results of tests conducted with the model, used at the gear design stage. In the presented model, the main goal is to reproduce the phenomena occurring in gears as well as possible, using numerous experiments in this direction featured in the literature. Many already historical models present different ways of modeling, but they often made significant simplifications, required by the limitations of the nature of computational capabilities. Differences also result from the purpose of the models being developed, and the analysis of these different ways of doing things makes it possible to choose the most appropriate approach.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2023, 33, 2; 183--195
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849273.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849268.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A zero-dimensional model used as a basis for numerical modelling of OP-650 boiler
Zerowymiarowy model kotła jako podstawa do obliczeń numerycznych kotła OP 650
Autorzy:
Hernik, B.
Pronobis, M.
Powiązania:
https://bibliotekanauki.pl/articles/172845.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power boiler
OP650 boiler
zero-dimensional model
CFD modelling
numerical modelling
kocioł energetyczny
kocioł OP-650
model zero-wymiarowy
modelowanie CFD
modelowanie numeryczne
Opis:
The numerical modelling of power boiler furnaces is often performed in the engineering practice. Quite often, however, the balance calculations of the entire boiler are not carried out. In this case, the flue gas temperature at the furnace outlet results from the numerical model and depends on the adopted assumptions (e.g. wall fouling or emissivity). However, the value determined in this way may be wrong, and the presented calculation method makes it impossible to verify it. One of the ways to improve the numerical model accuracy is the verification of the flue gas temperature at the furnace outlet value by calculations fully balanced by a zero-dimensional (0D) model based on measuring data. The numerical calculations should be carried in such a way that the average temperature at the furnace outlet in the computational fluid dynamical (CFD) model equals the temperature obtained from the 0D model. At the same time, the matching of this temperature should result from carefully selected assumptions of the numerical model, which have to correspond to the actual phenomena occurring in the furnace. This model presents the verification of the CFD model for the OP-650 boiler of a 225 MWel power unit. The results of numerical modelling of boiler according to non-premixed combustion model with mixture fraction/PDF (probability density function) approach was presented. Also numerical modelling of boiler with species transport model with volumetric reactions and finite rate chemistry was done.
W praktyce inżynierskiej często wykonywane jest numeryczne modelowanie palenisk kotłów energetycznych, przy czym często nie prowadzi się obliczeń bilansowych całego kotła. Temperatura spalin na wylocie z paleniska wynika wówczas z modelu numerycznego i zależy od przyjętych założeń (np. zanieczyszczenie ścian lub ich emisyjność). Tak wyznaczona wartość temperatury może jednak być błędna, a opisany sposób liczenia uniemożliwia jej weryfikację. Sposobem na poprawę dokładności modelu numerycznego jest weryfikacja temperatury spalin na wylocie z paleniska za pomocą w pełni zbilansowanych obliczeń modelem 0-wymiarowym opartym na danych pomiarowych. Obliczenia numeryczne powinny być tak prowadzone, aby średnia temperatura na wylocie z komory paleniskowej kotła w modelu CFD była równa temperaturze uzyskanej z modelu zerowymiarowego. Jednocześnie dopasowanie tej temperatury powinno wynikać z odpowiednio dobranych założeń modelu numerycznego, które muszą odpowiadać realnemu przebiegowi zjawisk zachodzących w palenisku. W niniejszej pracy dokonano opisanej weryfikacji modelu CFD dla kotła OP 650 do bloku 225 MWel. Przedstawiono wyniki modelowania numerycznego kotła wg algorytmu mixture fraction/PDF - z wykorzystaniem modelu spalania non-premixed oraz wyniki dla modelu opartego na reakcjach objętościowych z wykorzystaniem modelu finite-rate/eddy-dissipation.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 17-26
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced compact modeling of the deep submicron technologies
Autorzy:
Grabiński, W.
Bucher, M.
Sallese, J.-M.
Krummenacher, F.
Powiązania:
https://bibliotekanauki.pl/articles/309312.pdf
Data publikacji:
2000
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
ultra deep submicron (UDSM) technology
compact modeling
EKV MOS transistor model
MOSFET
matching
low power
RF applications
Opis:
The technology of CMOS large-scale integrated circuits (LSI's) achieved remarkable advances over last 25 year and the progress is expected to continue well into the next century. The progress has been driven by the downsizing of the active devices such as MOSFETs. Approaching these dimensions, MOSFET characteristics cannot be accurately predicted using classical modeling methods currently used in the most common MOSFET models such as BSIM, MM9 etc, without introducing large number of empirical parameters. Various physical effects that needed to be considered while modeling UDSM devices: quantization of the inversion layer, mobility degradation, carrier velocity saturation and overshoot, polydepletion effects, bias dependent source/drain resistances and capacitances, vertical and lateral doping profiles, etc. In this paper, we will discuss the progress in the CMOS technology and the anticipated difficulties of the sub-0.25 žm LSI downsizing. Subsequently, basic MOSFET modeling methodologies that are more appropriate for UDSM MOSFETs will be presented as well. The advances in compact MOSFET devices will be illustrated using application examples of the EPFL EKV model
Źródło:
Journal of Telecommunications and Information Technology; 2000, 3-4; 31-42
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis on the velocity of dust particles in the plate-type electrostatic precipitators used in thermoelectric power plants
Autorzy:
Popa, G. N.
Şora, I.
Dinis, C. M.
Deaconu, S. I.
Powiązania:
https://bibliotekanauki.pl/articles/207451.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
electrostatic precipitators
mathematical models
thermoelectric power plants
dust particles
gas velocity
power plant
elektrofiltry
model matematyczny
elektrownia
cząstki pyłu
prędkość gazu
Opis:
Experimental data collected from different plate-type electrostatic precipitators used in a thermoelectric power plant has been analyzed. The following parameters were considered: the collection efficiency, average migration velocity of dust particles, velocity distribution of the gas in the input and output channels of precipitators. The average migration velocity of dust particles can be estimated using various mathematical models, and the gas velocity can be computed using the velocity distributions from the input channels of the precipitators. The traveling time of dust particles between the electrodes is smaller than the traveling time along the precipitator sections.
Źródło:
Environment Protection Engineering; 2014, 40, 1; 85-102
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An approach to suppress high-frequency resonance using model predictive and selective harmonic elimination combined strategy
Autorzy:
Chen, Sitong
Chen, Xiaoqiang
Wang, Ying
Xiong, Ye
Powiązania:
https://bibliotekanauki.pl/articles/1841300.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CRH5 EMUs and traction power supply coupled system
high-frequency oscillation
high speed railway
model predictive control (MPC)
selective harmonic elimination pulse-width modulation (SHEPWM)
CRH5 EMU i system sprzężony z zasilaniem trakcyjnym
oscylacja wysokiej częstotliwości
kolej dużych prędkości
kontrola predykcyjna modelu (MPC)
selektywna eliminacja harmoniczna modulacja szerokości impulsu (SHEPWM)
Opis:
High-frequency resonance is a prominent phenomenon which affects the normal operation of the high-speed railway in China. Aiming at this problem, the resonance mechanism is analyzed first. Then, model predictive control and selective harmonic elimination pulse-width modulation (MPC-SHEPWM) combined control strategy is proposed, where the harmonics which cause the resonance can be eliminated at the harmonic source. Besides, the MPC is combined to make the current track the reference in transients. The proposed control has the ability to suppress the resonance while has a faster dynamic performance comparing with SHEPWM. Finally, the proposed MPC-SHEPWM is tested in a simulation model of CRH5 (Chinese Railway High-speed), EMUs (electric multiple units) and a traction power supply coupled system, which shows that the proposed MPC-SHEPWM approach can achieve the resonance suppression and shows a better dynamic performance.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 415-430
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An efficient microgrid model based on Markov fuzzy demand-side management
Autorzy:
Jabash Samuel, G. K.
Sivagama Sundari, M. S.
Bhavani, R.
Jasmine Gnanamalar, A.
Powiązania:
https://bibliotekanauki.pl/articles/27311444.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
smart grid
fuzzy Markov decision process
power scheduling
operating cost
nonlinear model predictive control
inteligentna sieć
planowanie mocy
koszt operacyjny
proces decyzyjny Markowa rozmyty
regulator predykcyjny nieliniowego modelu
Opis:
Today’s electricity management mainly focuses on smart grid implementation for better power utilization. Supply-demand balancing, and high operating costs are still considered the most challenging factors in the smart grid. To overcome this drawback, a Markov fuzzy real-time demand-side manager (MARKOV FRDSM) is proposed to reduce the operating cost of the smart grid system and maintain a supply-demand balance in an uncertain environment. In addition, a non-linear model predictive controller (NMPC) is designed to give a global solution to the non-linear optimization problem with real-time requirements based on the uncertainties over the forecasted load demands and current load status. The proposed MARKOV FRDSM provides a faster scale power allocation concerning fuzzy optimization and deals with uncertainties and imprecision. The implemented results show the proposed MARKOV FRDSM model reduces the cost of operation of the microgrid by 1.95%, 1.16%, and 1.09% than the existing method such as differential evolution and real coded genetic algorithm and maintains the supply-demand balance in the microgrid.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 3; art. no. e145569
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości zastosowania sterowania predykcyjnego turbiną parową elektrowni jądrowej
Analysis of model predictive control applicability for control of nuclear power plant steam turbine
Autorzy:
Kobylarz, A.
Duzinkiewicz, K.
Grochowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/269092.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
turbina parowa
elektrownia jądrowa
sterowanie predykcyjne
sterowanie PID
steam turbine
nuclear power plant
model predictive control
PID control
Opis:
Artykuł przedstawia wyniki wstępnej analizy możliwości zastosowania sterowania predykcyjnego MPC turbiną parową elektrowni jądrowej. Tradycyjnie przyjmuje się, że turbina pracuje w jednym punkcie pracy odpowiadającym jej mocy nominalnej, co pozwala na stosowanie klasycznych regulatorów PID. Synteza sterowania dla warunków zmiennego punktu pracy wymaga uwzględnienia nieliniowego charakteru procesów turbiny oraz możliwości naruszania przez generowane sterowanie ograniczeń dopuszczalnego działania. W algorytmie MPC wykorzystany został opracowany wcześniej nieliniowy model turbiny 4CKC465. Opracowany algorytm MPC został porównany z regulatorem PID strojonym dla trajektorii zadanej. Proponowane sterowanie MPC umożliwia sterowanie turbiną z zadowalającymi skutkami. W artykule dokonano krótkiej analizy wpływu parametrów algorytmu MPC na jakość sterowania turbiną parową.
The results of a preliminary analysis of the model predictive control (MPC) in steam turbine of nuclear power plant applicability was presented. Traditionally it is assumed that the turbine works in single operating point corresponding to its nominal power, what allows the usage of classic PID controllers. Synthesis of control for varying operating point conditions requires taking under consideration a nonlinear character of processes taking place within steam turbine as well as possibility of control constraints violation. In MPC algorithm, previously developed nonlinear model of 4CK465 steam turbine was used. Designed MPC algorithm was compared with PID controller tuned for a given trajectory. MPC control proposed in this paper gives satisfactory results of steam turbine control. In this article a brief analysis of the MPC algorithms parameters impact into control quality of steam turbine was presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 83-86
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza oddziaływania stopnia zawilgocenia oraz temperatury na parametry schematu zastępczego izolacji papierowo-olejowej wyznaczonego w oparciu o model Cola-Cola
Analysis of the impact of the degree of moisture and temperature on the parameters substitute schema paper-oil insulation on the basis of the Cole-Cole model
Autorzy:
Wolny, S.
Adamowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/158804.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
izolacja papierowo-olejowa
spektroskopia częstotliwościowa dielektryków
model Cola-Cola
transformatory energetyczne
paper-oil insulation
frequency dielectric spectroscopy
Cole-Cole model
power transformers
Opis:
Transformatory dużej mocy należą do najważniejszej grupy urządzeń układów sieci elektroenergetycznych, których stan izolacji papierowo-olejowej transformatora w bardzo dużym stopniu decyduje o ich prawidłowej pracy. Pomimo rozwoju produkcji nowych materiałów elektroizolacyjnych, np. papierów syntetycznych, nadal w większości urządzeń dominuje izolacja oparta na bazie celulozy w połączeniu z olejem mineralnym. Obecnie metody diagnozowania stanu izolacji pozwalają przedsiębiorstwom energetycznym bezpiecznie wydłużać czas eksploatacji transformatorów energetycznych przy akceptowalnie niskim ryzyku wystąpienia awarii. W artykule opisano jedną z metod wykorzystywanych w diagnostyce izolacji papierowo–olejowej, tzn. spektroskopię częstotliwościową dielektryków – określoną skrótem FDS (Frequency Dielectric Spectroscopy). Na podstawie uzyskanych pomiarów obliczono wartości parametrów modelu Cola-Cola (εs, ε∞, α, τ). Przedstawiono możliwość wykorzystania parametrów modelu Cola-Cola, pod kątem ich przydatności do symulacji oddziaływania stopnia zawilgocenia oraz temperatury na parametry schematu zastępczego izolacji papierowo-olejowej.
Transformers belong to the most important group of devices of power networks systems the state of paper-oil insulated transformer to a large extent decides their correct operation. Despite the development of production of new materials, electrical insulation, for example, synthetic papers, most devices still dominate the insulation based on cellulose in combination with mineral oil. Currently, methods for diagnosis of insulation allow energy companies to safely extend the life of power transformers at acceptably low risk of failure.The article describes one of the methods used in the diagnosis insulation paper-oil, ie frequency dielectric spectroscopy – defined abbreviation FDS (Frequency Dielectric Spectroscopy). Based on the measurements was calculated parameters of the Cole-Cole model (εs, ε∞, α, τ). Presents the possibility of using Cole-Cole model parameters, under their suitability to simulate the impact of the degree of moisture and temperature the substitute schema parameters insulation of paper and oil.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 259; 107-108
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza mocy i sprawności układu kogeneracyjnego turbiny gazowej i parowej
The Comparative Study on Selected Operation Parameters of a Combined Cycle Plant
Autorzy:
Chinhenha, A.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/947654.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Morski w Gdyni. Wydawnictwo Uniwersytetu Morskiego w Gdyni
Tematy:
obieg gazowo-parowy
moc elektryczna i sprawność całkowita obiegu
model analityczny
badania symulacyjne
analiza parametrów
combined cycle plant
electric power and total efficiency
analytical model
simulation research
parameters analysis
Opis:
Przedmiotem pracy są badania symulacyjne i analiza wybranych parametrów siłowni pracującej w obiegu gazowo-parowym. Celem pracy jest opracowanie metodyki oceny mocy i sprawności siłowni z turbinami pracującymi w obiegu gazowo-parowym z wykorzystaniem autorskiego modelu analitycznego rozważanej instalacji. Uzyskane na podstawie przyjętego modelu szacunkowe wartości mocy i sprawności siłowni porównano z wynikami uzyskanymi podczas testów odbiorczych przykładowej instalacji, przeprowadzonych przez jedno z wiodących konsorcjów, działających w obszarze systemów wytwarzania energii (SIEMENS AG. Power Generation Group).
This paper deals with analysis and simulation research of selected parameters of combined cycle plant. Presented work is focused on elaboration of the evaluation methodology of power and efficiency of combined cycle plant based on the author’s analytical model of considered installation. The estimated values of power and efficiency obtained on the basis of the elaborated model have been compared with the results obtained during the final tests of the exemplary installations carried out by the one of the leading producers of the systems in the power generation field.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Gdyni; 2018, 103; 26-42
1644-1818
2451-2486
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Gdyni
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy bloku nadkrytycznego 900 Mwe współpracującego z obiegiem ORC
Thermodynamic analysis of the supercritical 900MWe power unit, co-operating with an ORC cycle
Autorzy:
Ziółkowski, P.
Mikielewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/172841.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blok nadkrytyczny
obieg ORC
model numeryczny
supercritical power unit
ORC cycle
numerical model
Opis:
W pracy przedstawiono analizę termodynamiczną bloku nadkrytycznego o mocy 900 MWe współpracującego z obiegiem ORC (organic Rankine cycle). Wykonano symulacje numeryczne pracy siłowni dla warunków nominalnych określając jej moc i sprawność elektryczną. Ponadto przeanalizowano pracę bloku współpracującego z obiegiem ORC dla czterech czynników roboczych, tj.: propan, izobutan, pentan i etanol. W układzie ORC górne źródła ciepła stanowi woda z systemu odzysku ciepła o temperaturze 90 °C wspomagana ciepłem z upustu pary z turbiny parowej. Analizę wykonano za pomocą kodów numerycznych typu CFM.
The paper presents thermodynamic analysis of the supercritical 900 MWe power unit, cooperating with an ORC cycle. Numerical simulations of the power unit at its nominal operating conditions were conducted to compute its power and electric efficiency. Furthermore, operation of the power unit with an ORC medium was conducted for four types of the medium, i.e., propane, isobutene, pentane and ethanol. As a heat source for the ORC setup, water from the heat recovery system at the temperature of 90 °C supported with steam extracted from the steam turbine, was used. The analysis was performed with use of CFM type numerical codes.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 165-174
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy zakładowej sieci elektroenergetycznej przy uwzględnieniu niepewności parametrów modelu sieci
The analysis of the operation of an industrial power network taking into account the uncertainty of network model parameters
Autorzy:
Nocoń, A.
Paszek, S.
Walczak, J.
Powiązania:
https://bibliotekanauki.pl/articles/267181.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
zakładowa sieć energetyczna
praca wyspowa
stany przejściowe
niepewność parametrów modelu
poprawa stabilności kątowej
industrial power network
work autonomously
transient states
uncertainty of the model parameters
improving the angular stability
Opis:
W artykule przedstawiono analizę pracy w wybranych stanach nieustalonych zakładowej sieci elektroenergetycznej pracującej autonomicznie i we współpracy z Krajowym Systemem Elektroenergetycznym (KSE). Założono, że w sieci zainstalowane są dwa zespoły wytwórcze: jeden z generatorem asynchronicznym a drugi z generatorem synchronicznym. Badano zachowanie się zespołów wytwórczych m.in. w następujących stanach nieustalonych: przejście sieci zakładowej od współpracy z KSE do pracy autonomicznej oraz wyłączenie zespołu asynchronicznego w czasie autonomicznej pracy sieci. W analizie uwzględniono niepewność parametrów wybranych modeli elementów sieci. Opisano zagadnienie modelowania rozrzutu parametrów modeli układów elektrycznych. Polega ono na wyznaczeniu obwiedni (pasm granicznych) rodziny przebiegów analizowanych sygnałów. Obwiednie te wyznaczano przez wielokrotne symulacje przy zmienianych w odpowiedni sposób parametrach modelu sieci. Pokazano możliwości poprawy stabilności kątowej analizowanej sieci przy zastosowaniu układów stabilizujących o odpowiedniej strukturze i optymalizowanych parametrach. Zaproponowano wprowadzenie tych układów stabilizujących do układu regulacji mocy turbiny oraz do układu wzbudzenia generatora synchronicznego.
The analysis of the operation of an industrial power network in selected transient states is presented in the paper. The network works autonomously and in cooperation with the Polish National Power System (PNPS). It was assumed that two generating units, one with an asynchronous generator and the other with a synchronous generator, were installed in the network. There was investigated the behaviour of the generating units in the following transient states: network transition from cooperation with the PNPS to autonomous operation and switching off the asynchronous unit during autonomous operation of the network. In the analysis, there was taken into account the uncertainty of the parameters of selected models of the network elements. The problem of modelling the dispersion of parameters of electrical system models is described in the paper. It consists in determining envelopes (limit bands) of a family of waveforms of the analysed signals. These envelopes were determined by multiple simulations for appropriately changed parameters of the network model. Possibilities of improving the angular stability of the analysed network using stabilizing systems with a suitable structure and optimized parameters are shown. Introduction of these stabilizing systems to the turbine governor and the synchronous generator excitation system is proposed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 79-82
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wrażliwości modelu potęgowego liczby zdarzeń drogowych w Polsce
Sensitivity analysis of power model of road accidents in Poland
Autorzy:
Rogowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/194098.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
model potęgowy
bezpieczeństwo ruchu drogowego
prognozowanie
power model
road safety
forecasting
Opis:
Wypadki drogowe stanowią istotny problem społeczny i ekonomiczny, stąd różnorodne działania zmierzające zarówno do zmniejszenia ich liczby, jak i ich skutków. Jednym z pierwszych modeli szacujących liczbę ofiar śmiertelnych w ruchu drogowym był model Smeeda będący modelem potęgowym o zmiennych objaśniających – liczbie pojazdów i liczbie ludności. Choć klasyczny model Smeeda, przynajmniej w warunkach polskich, jest nieprzydatny, to z parametrami estymowanymi metodą najmniejszych kwadratów jako model wykorzystujący klasyczne podejście do prognozy wypadków na podstawie zmiennych opisujących wystawienie na ryzyko, dość dobrze opisuje liczbę ofiar śmiertelnych i rannych w wypadkach drogowych, jak i liczbę wypadków drogowych. Jednak jego przydatność do celów prognostycznych warunkowana jest zmiennością w czasie parametrów modelu i wrażliwością modelu na zamiany wartości zmiennych objaśniających i parametrów modelu. W artykule przedstawiono wyniki analizy wrażliwości modeli potęgowych dla których parametry estymowano na podstawie danych rzeczywistych z lat 2000–2011. Stwierdzono małą wrażliwość modeli na zmiany wartości zmiennych objaśniających (uwzględniając zakres danych właściwy dla warunków polskich), co można uznać za zaletę w przypadku prognozowania – minimalizacja błędów związanych z prognozowaniem wartości zmiennych objaśniających. Jednocześnie stwierdzono bardzo dużą wrażliwość modeli na zmiany wartości parametrów – wykładników potęg, co powoduje duże trudności w doborze danych rzeczywistych do szacowania parametrów modeli. Zaproponowano modele z ustaloną wartością parametru jednej ze zmiennych objaśniających i parametrem w funkcji czasu dla drugiej zmiennej, podając postacie tych funkcji.
Road accidents are a major social and economic problem, therefore various activities are undertaken in order to reduce both their number and consequences. The Smeed’s model has been one of the first. It is a power model with two explanatory variables: population and the number of vehicles. In Polish conditions the Smeed’s classic model is useless. However, the exponential models with parameters estimated by the least squares method describe reasonably well the number of fatalities and road accidents injuries, as well as the number of road accidents itself. Nevertheless, their usefulness for forecasting purposes is conditioned on the changes the values of the parameters at the time and on the sensitivity to changes of explanatory variables values and model parameters. This paper presents the results of the sensitivity analysis for the power models which parameters were estimated on the base of actual data from the years 2000-2011. Models low sensitivity to changes of explanatory variables values have been found, which can be regarded as an advantage in case of forecasting; by minimizing errors connected with forecasting the values of explanatory variables. At the same time, it was detected that models were very sensitive to changes of parameters values – the exponents. Models with a fixed value of the parameter to one of the explanatory variables and a function of the time for the second variable have been proposed as well as proposed forms of these functions.
Źródło:
Transport Miejski i Regionalny; 2013, 5; 33-39
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies