Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power measurements" wg kryterium: Temat


Tytuł:
Prototype of a DSP-based instrument for in-service wireless transmitter power measurement
Autorzy:
Angrisani, L.
Cennamo, F.
Scarpato, G.
Schiano Lo Moriello, R.
Powiązania:
https://bibliotekanauki.pl/articles/220862.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wireless transmitters
power measurements
in-service testing
DSP
Opis:
A prototype of a DSP-based instrument for in-service transmitter power measurements is presented. The instrument implements a signal-selective algorithm for power measurements that is suitable for use in wireless environments, where possible uncontrolled interfering sources are present in the radio channel and are overlapped to the signal emitted by the transmitter under test, possibly in both time and frequency domain. The measurement method exploits the principles of cyclic spectral analysis, which are briefly recalled in the paper. Potentialities, as well as limitations of the prototype use are discussed, and the results of experiments with both modulated and unmodulated interfering sources are presented.
Źródło:
Metrology and Measurement Systems; 2014, 21, 4; 699-708
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja błędów częstotliwościowych obwodów wejściowych przy pomiarach wartości skutecznej sygnałów i mocy czynnej
Frequency errors correction of input circuit in RMS and power measurements
Autorzy:
Furmankiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/155215.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
korekcja dynamiczna
pomiar wartości skutecznej
pomiary mocy
dynamic correction
RMS measurements
power measurements
Opis:
W artykule przedstawiono metodę programowej korekcji błędów częstotliwościowych liniowych obwodów wejściowych realizowaną w dziedzinie widmowej. Metoda wymaga znajomości częstotliwościowych charakterystyk błędów modułu i błędów fazowych korygowanego obwodu. Niepewność wyznaczenia tych charakterystyk jest jednym ze składników decydujących o skuteczności korekcji. Przedstawiono analizę niepewności pomiarów po korekcji przy pomiarach wartości skutecznej i mocy czynnej sygnałów odkształconych.
This paper presents a software method of dynamic errors correction realised in spectrum domain. The correcting method is based on the knowledge of frequency characteristics of magnitude and phase errors. Measurement uncertainty of this errors influence on correction efficiency. An analyses of measurement uncertainty after correction with RMS and real power of distorted signals measurements is also shown.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 691-694
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty analysis of measuring system for instantaneous power research
Autorzy:
Dzwonkowski, A.
Swędrowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/221896.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measuring system
metrological analysis
power measurements
measurement uncertainty
induction motor diagnostics
Opis:
The electrical power drawn by an induction motor is distorted in case of appearance of a certain type of failures. Under spectral analysis of the instantaneous power one obtains the components which are connected with definite types of damage. An analysis of the amplitudes and frequencies of the components allows to recognize the type of fault. The paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped to determine the measurement uncertainty which can be expected during bearing diagnostic measurements, by the method relying on measurement and analysis of the instantaneous power of an induction machine.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 573-582
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary parametrów silnika pojazdu z wykorzystaniem akcelerometru
Measuring vehicle engines parameters with accelerometer
Autorzy:
Nowik, M.
Powiązania:
https://bibliotekanauki.pl/articles/320247.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
pomiar przyspieszenia
pomiary momentu i mocy
przenośna hamownia
acceleration measurements
torque and power measurements
protable dynamometer
Opis:
W artykule omówiono metodologię wykonywania pomiarów parametrów ruchu pojazdu z wykorzystaniem czujników przyspieszenia. Przedstawiony został sposób kalibracji statycznej czujnika pozwalający m.in. na znaczne ograniczenie błędu wnoszonego do pomiaru wynikającego z niedokładnego zamontowania akcelerometru na obiekcie, którego parametry ruchu są mierzone. Oprócz samego pomiaru trajektorii poruszania się pojazdu, przedstawiono również metodę uzyskiwania informacji na temat głównych parametrów silnika (maksymalny moment i moc) oraz tworzenia ich przebiegów w odniesieniu do prędkości obrotowej.
In this paper, techniques of vehicle movement parameters measurments using acceleration sensors has been discussed. Author has described a method of acceleration and vehicle speed aquisition and evaluating characteristics of engines torque and power.
Źródło:
Elektrotechnika i Elektronika; 2008, 27, 2; 98-103
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power losses measurements of nanocrystalline and amorphous magnetic cores
Pomiary strat mocy w rdzeniach nanokrystalicznych i amorficznych
Autorzy:
Gozdur, R.
Majocha, A.
Powiązania:
https://bibliotekanauki.pl/articles/1368678.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
power loss
bridge method
low-loss magnetic materials
power measurements
strata mocy
metoda mostkowa
niskostratne materiały magnetyczne
pomiary mocy
Opis:
Artykuł dotyczy zagadnień związanych z pomiarem mocy strat w rdzeniach magnetycznych wykonanych z niskostratnych taśm nanokrystalicznych i amorficznych. W artykule zaprezentowana została opracowana metoda mostkowa pomiaru strat mocy. Metoda należy do grupy bezpośrednich metod pomiaru mocy strat w układzie mostka niezrównoważonego. W treści zamieszczono najważniejsze elementy analizy obwodowej, schematy układów pomiarowych i algorytm pomiaru stratności w próbkach magnetycznych zamkniętych. Aplikację proponowanej metody przedstawiono na przykładzie pomiaru stratności w toroidalnym pakietowanym rdzeniu amorficznym wykonanym z materiału Metglas-2605S3A i toroidalnym rdzeniu zwijanym wykonanym z taśmy Magnetec Nanoperm. W zestawieniach wyników pomiarów ujęto stratności wyznaczone w szerokim zakresie indukcji przy częstotliwości 50Hz. Osiągniętą rozdzielczość i dokładność metody potwierdzają wyniki pomiarów stratności których wartość nie przekraczała 200mW. Dodatkowo w artykule zaprezentowano budżet niepewności i analizę dokładności zaprezentowanych wyników pomiarów.
The paper refers to the measurement of power loss in magnetic cores made of low-loss amorphous and nanocrystalline ribbons. Elaborated bridge method of power loss measurement is presented in the article. The most important issues of circuit analysis, circuit diagram and algorithm of measurement in closed magnetic specimens have been included in the content. Application of the suggested method is shown on the example of power loss measurements in toroidal, stacked amorphous core made of Metglas-2605S3A and toroidal, winding core made of Magnetec - Nanoperm ribbon. In the measurement results there are power losses determined for different maximum induction by the magnetizing frequency of 50Hz included. Achieved resolution and accuracy of the method confirm the measurement results whose values have not crossed 200mW/kg. Additionally in the paper the analysis and budget of uncertainty is presented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 175-179
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Hybrid Filtering Solution for Marine Electric Network
Autorzy:
Xu, X - Y.
Mindykowski, J.
Chen, C. L. P.
Powiązania:
https://bibliotekanauki.pl/articles/259582.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
electrical engineering
marine vehicle power systems
power system harmonics
power system measurements
quality control
Opis:
This paper presents a Hybrid APF/PFC/PPF Circuit (active power filtering and power factor correction circuit aided by shunt passive filter) for harmonic suppression and power factor correction in a marine electric network. By employing the proposed hybrid circuit, marine electric power network voltage and current can be maintained as being sinusoidal, and the power factor is close to 1. The effectiveness of the proposed method that is applied to a marine electric network is demonstrated through a simulation experiment. The results show that the expected performances are achieved.
Źródło:
Polish Maritime Research; 2010, 2; 72-78
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Test Bench for Selected Transmission Parameters of Power Line Conductors
Autorzy:
Chruszczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/227032.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LabVIEW
power line measurements
power line communication
amplitude spectrum
phase spectrum
crosstalk measurement
Opis:
This paper presents automatic test bench used for measurement of selected high frequency parameters of a power copper line. The aim is fast estimation of line behavior in context of Power Line Communication (PLC). The hardware interface uses sinusoidal waveform generator, digital oscilloscope and a PC-class computer. The software interface created in LabVIEW environment performs signal processing and data presentation.
Źródło:
International Journal of Electronics and Telecommunications; 2015, 61, 1; 59-65
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary wyższych harmonicznych napięcia w sieci 400 kV
Measurements of voltage harmonics in 400 kV transmission network logic
Autorzy:
Pawełek, R.
Wasiak, I.
Błajszczak, G.
Jurek, M.
Olak, J.
Powiązania:
https://bibliotekanauki.pl/articles/267443.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyższe harmoniczne
jakość energii elektrycznej
pomiary jakości energii elektrycznej
voltage harmonics
power quality
power quality measurements
Opis:
Przedstawiono analizę wyników pomiarów wyższych harmonicznych napięcia wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Wyniki pomiarów z dzielnika rezystancyjnego przyjęto jako referencyjne odnosząc do nich wyniki pomiarów uzyskane przy wykorzystaniu przekładników. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
The paper deals with the analysis of voltage harmonics measurements performed in the transmission network of 400 kV. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 139-142
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie Internetu do badania stabilności źródeł promieniowania optycznego
Internet in optical sources stability measurements
Autorzy:
Hermanowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/317634.pdf
Data publikacji:
2002
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
automatyzacja stanowisk pomiarowych
GPIB-Ethernet
pomiary mocy optycznej
wzorcowanie przyrządów pomiarowych
systems automation
optical power measurements
test and instrument calibration
Opis:
Opisano przykład wykorzystania rozproszonego systemu pomiarowego do pomiaru parametrów źródeł promieniowania optycznego. W systemie tym przyrządy pomiarowe są sterowane przez szynę GPIB i środowisko LabWindows. Konwerter GPIB-ENET służy do komunikacji komputera z rzeczywistym systemem pomiarowym. Podkreślono, że jest możliwa zdalna konfiguracja systemu, diagnozowanie aparatury oraz odbiór danych pomiarowych.
The objective is to build automatic system for optical sources calibration. System consists of GPIB controlled instruments. GPIB-Ethernet converter provides remote access to the system. The use of Internet technology in measurements enables unlimited abilities for system developing and data acquisition
Źródło:
Telekomunikacja i Techniki Informacyjne; 2002, 3-4; 79-84
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of Voltage Harmonics in 400 kV Transmission Network
Pomiary wyższych harmonicznych napięcia w sieci 400 kV
Autorzy:
Pawełek, R.
Wasiak, I.
Jurek, M.
Powiązania:
https://bibliotekanauki.pl/articles/397094.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
voltage harmonics
power quality
power quality measurements
wyższe harmoniczne
jakość energii elektrycznej
pomiary jakości energii elektrycznej
Opis:
The paper deals with the analysis of voltage harmonics measurements performed in the 400 kV transmission network. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.
W artykule przedstawiono analizę wyników pomiarów wyższych harmonicznych napięcia, wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Wyniki pomiarów z dzielnika rezystancyjnego przyjęto jako referencyjne, odnosząc do nich wyniki pomiarów uzyskane przy wykorzystaniu przekładników. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
Źródło:
Acta Energetica; 2014, 2; 127-134
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary rezystancji termicznej tranzystorów mocy z wykorzystaniem metod pirometrycznych
Application of the pirometric methods for the thermal resistance of power transistors measurements
Autorzy:
Górecki, K.
Zarębski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157592.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary rezystancji termicznej tranzystorów
metody pirometryczne
application of pirometric methods
thermal resistance
power transmitors measurements
Opis:
Praca dotyczy pomiarórw rezystancji termicznej wybranych tranzystorów mocy przy wykorzystaniu metod pirometrycznych. Zamieszczono szereg wyników pomiarów tego parametru w funkcji mocy wydzielanej w elemencie, uzyskanych przy zastosowaniu różnych radiatorów obudów i orientacji przestrzennej badanych tranzystorów. Zbadano również nierównomierność przestrzennego rozkładu temperatury w badanej strukturze.
In this paper the problem of measurements of the thermal resistance (Rth) of the selected power transistors with the use of the pirometric method is considered. The measuremental results Rth of bipolar transistors 2N3055 and MOS transistors IRF840 for the dissipated power changing as well as for the various kinds of device cases the temperature distribution on the chip has been estimated.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 1, 1; 41-44
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie modułu FPGA platformy sprzętowej sbRIO-9602 do obliczania fazora z zastosowaniem DFT
The use of FPGA module of sbRIO-9602 system for phasor computation with the use of DFT
Autorzy:
Barczentewicz, S.
Nabielec, J.
Powiązania:
https://bibliotekanauki.pl/articles/151469.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyznaczanie fazora
FPGA
pomiary w systemie elektroenergetycznym
błędy obliczeniowe
phasor estimation
power system measurements
computational errors
Opis:
Praca dotyczy problemu implementacji algorytmu obliczania fazora w jednym układzie scalonym FPGA-SPARTAN, w którym jednocześnie zaimplementowany jest protokół komunikacyjny czasu rzeczywistego dostosowany do PSS (Power Stabilization System). Przedstawione rozwiązanie pozwala na implementację takich obliczeń z możliwie najmniejszą objętością zajmowanych zasobów FPGA i przy jak najmniejszych błędach obliczeniowych. Algorytm obliczeń oparty został o dyskretne przekształcenie Fouriera.
This work presents a novel approach to implementation of the phasor estimation algorithm using a single FPGA module, with simultaneous communication protocol compatible with Power Stabilization System on it. The presented implementation allows for calculations using as little resources as possible. This paper is organized as follows. In Section 1 the definitions and convention of graphical representation of phasor and synchrophasor (Fig. 1) given by [1] are quoted. Moreover, the definition of discrete Fourier transform is recalled [4], for explanation of its usage in the presented algorithm. In Section 2 the programming environment LabVIEW FPGA and the used instrumentation (sbRIO-9602 platform with FPGA module Xilinx Spartan, ADC converter NI9215E) are described. Furthermore, the proposed algorithm of phasor estimation is presented. Figure 2 shows the simplified block diagram of the designed algorithm. Afterwards, the methodology and results from the conducted tests are listed. Table 1 presents the resources utilization statistics of FPGA, and Table 2 shows the compilation of the test results of computational errors of module and phase estimation. Phasor estimation algorithm is based on DFT computation, and more specifically only one DFT bin is used when sampling frequency and observation length are known. Algorithm uses this fact to minimize demand for FPGA resources. Conducted tests showed that the main problem with obtaining high accuracy of algorithm is limited precision of fixed-point calculations.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 3, 3; 141-143
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wind turbine harmonics caused by unbalanced grid currents
Autorzy:
Dettmann, K. D.
Schostan, S.
Schulz, D.
Powiązania:
https://bibliotekanauki.pl/articles/262590.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
AC machines
circuit analysis
current measurement
harmonic analysis
harmonic distortion
power system harmonics
power system measurements
sequences
wind energy
wind power generation
Opis:
For wind turbines that feed into public grids limits for voltage and current harmonics must be assured. To verify that the actual levels are valid, measurements are necessary. Problems can occur to determine which part of these harmonics has its origin in the wind turbine. It is shown that also harmonics which originally have zero sequences can be transferred over a delta-star-transformer, if the currents of the wind turbine are asymmetric due to unbalanced loads. Measurements in an existing wind turbine configuration are discussed, which confirm the described effects.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 17-23
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applications of monitoring of electric power parameters to performance evaluation of a model vacuum-assisted moulding installation
Autorzy:
Ziółkowski, E.
Brzeziński, M.
Wrona, R.
Smyksy, K.
Zyzak, P.
Powiązania:
https://bibliotekanauki.pl/articles/382938.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mechanizacja procesów odlewniczych
automatyzacja procesów odlewniczych
pomiar elektroenergetyczny
formowanie podciśnieniowe
mechanisation of foundry processes
automation of foundry processes
electric power measurements
vacuum-assisted moulding processes
Opis:
Vacuum conditions in foundry installations are generated using electric-driven vacuum pumps. The purpose of the experiment is to evaluate the performance of a vacuum-assisted system for compaction of moulding sand basing on registered plots of selected electric power parameters of the power-supplying system of the pumps. Model testing done on an experimental vacuum system installation, power-supplied from a system incorporating the recorders of instantaneous current and voltage values. Following the numerical procedure, the experimental data are analysed to yield mathematical relationships between the variations of the generated vacuum pressure levels and variations of selected electric power parameters. Registered and computed values of selected parameters: instantaneous and RMS voltage and current values, active, reactive and apparent power levels and power coefficient allow for diagnosing the adequacy and reliability of the system operation. According to the authors, the applied monitoring of the power parameters of a vacuum-assisted installation may become an effective and easy practical method of evaluating the performance of such installations, used also in foundry plants.
Źródło:
Archives of Foundry Engineering; 2012, 12, 2; 267-272
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and assessment of measurements results of electric power demand in a model vacuum-assisted moulding installation
Autorzy:
Smyksy, K.
Wrona, R.
Brzeziński, M.
Ziółkowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/380436.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mechanizacja procesów odlewniczych
automatyzacja procesów odlewniczych
pomiar elektroenergetyczny
formowanie podciśnieniowe
mechanisation of foundry processes
automation of foundry processes
electric power measurements
vacuum assisted moulding processes
Opis:
In this article the main problems related with the proper choice of the design and operation parameters of vacuum installation in vacuum moulding system have been discussed. In such system a vacuum are generated using electric-driven vacuum pumps. The aim of the experiment is to evaluate the performance of a vacuum system basing on registered plots of selected electric power parameters of the power-supplying system of the pumps with parallel measurements instantaneous values of pressure in selected points of model stand. The measurements system for power-supply unit has incorporated the recorders of instantaneous current and voltage values. Following the suitable numerical procedure, the experimental data are analysed to yield mathematical relationships between the variations of the generated vacuum pressure levels and variations of selected electric power parameters. According to the authors, the applied measurements system of the parameters of a vacuum-assisted installation may become an effective and easy practical method of evaluating the performance of such installations, used also in industry.
Źródło:
Archives of Foundry Engineering; 2012, 12, 4; 135-140
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stany nieustalone towarzyszące pomiarowi impedancji pętli zwarcia w obwodach wyjściowych zasilaczy bezprzerwowych UPS
Transient states associating loop impedance measurement in the output line of UPS power supplies
Autorzy:
Olesz, M.
Katarzyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/266602.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
stany nieustalone
zasilacze bezprzerwowe
pomiary jakości energii elektrycznej
impedancja pętli zwarcia
transients
uninterruptible power supplies
power quality measurements
fault loop impedance
Opis:
W pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem wielokanałowym potwierdziły poprawność danych uzyskiwanych w celu określenia reakcji zasilacza na zaburzenia występujące na wejściu i wyjściu urządzenia. W pracy analizowano wyniki pomiarów impedancji pętli zwarciowej zmierzone przyrządem wymuszającym poziomy prądu zwarciowego na linii zasilającej odbiorniki energii elektrycznej we wszystkich stanach pracy zasilacza, a następnie porównywano je z wynikami obliczeń przeprowadzonych na uzyskanych przebiegach prądu i napięcia.
The paper presents the methodology and the results of transient measurement in on-line Uninterruptable Power Supply (UPS). There were two power quality measurement instruments (synchronised with time) used for registering the events in UPS input and output. The recorders compress the obtained measurement data, which may introduce additional measurement errors of measured values, i.e. voltage and current. Additional registrations with a multi-channel oscilloscope confirmed the correctness of the obtained data in order to determine the reaction of the UPS to the disturbances occurring in UPS input and output. The work analysed the results of loop impedance, measured by a meter that forces short-circuit current in the line supplying electric load, in all states of the UPS, and then they were compared with the results of calculations carried out on the obtained current and voltage waveforms. The measurement of fault loop impedance in UPS output line should be performed in active static switch (bypass mode), because UPS will operate in this mode after switching from inverter operation due to high current forcing during a short circuit in the UPS output. Measurement of fault loop impedance in UPS output circuits, when it is in AC-DC-AC double conversion mode, may result with loop impedance overstating by meters, which in turn limits recognition of the tested installation as safe from the protection against electric shock by automatic power off point of view. The values of calculated loop impedance at forced high current, i.e. 160 A in the UPS output, when it is respectively in the manual bypass and static switch mode, are 4% and 2.5% lower than the ones presented by meter after measure by forcing high current. Differences in impedance of the static switch and manual bypass UPS mode can be the basis for the estimation of the thyristor impedance. Estimation of direct measurement results with 14.6 m, and according to the calculation of recorded transients it is about 16.1 m.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 61; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prace profesora Włodzimierza Krukowskiego (1887 - 1941) w dziedzinie układów pomiarowych i ich rola w rozwoju metrologii elektrycznej
The work of Professor Wlodzimierz Krukowski (1887 - 1941) in the field of measurement circuits and their role in the development of electrical metrology
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/156445.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomocnicze układy laboratoryjne
pomiary rezystancji wewnętrznej akumulatorów
rezystory wzorcowe
kompensator prądu przemiennego
pomiary 3- fazowe mocy
pomiary energii
pomiary strat
auxiliary laboratory systems
battery internal resistance measurement
standard resistors
AC potentiometer
3-phase power measurements
energy losses
power losses
Opis:
Przedstawiono studium o pracach Profesora Politechniki Lwowskiej Włodzimierza Krukowskiego twórcy wielu elektrycznych układów pomiarowych i ich historycznym znaczeniu dla rozwoju metrologii elektrycznej. We wprowadzeniu scharakteryzowano krótko karierę zawodową i dorobek Profesora oraz Jego uczniów i następców. Następnie omówiono Jego prace dotyczące pomocniczych układów laboratoryjnych, w tym: do regulacji napięcia przy sprawdzaniu przyrządów, do eliminacji wpływu prądów upływu izolacji i do pomiaru ogniw wzorcowych i rezystancji wewnętrznej akumulatorów. Przedstawiono Jego podstawowe prace w dziedzinie układów do dokładnych pomiarów rezystancji wzorcowych, kompensatorów prądu stałego i przemiennego oraz przykład patentu do pomiarów mocy w obwodach trójfazowych. Podkreślono ponadczasową rolę prac Profesora w metrologii.
The study about works of Professor Vladimir Krukowski of Lvov Polytechnic, author of many electrical measurement systems and his historical significance for the development of the electrical metrology is presented. The introduction briefly characterizes career and achievements of the Professor, his collaborators and successors. He put an enormous personal and organizational contributions to the development of the electrical measurement techniques in three European countries: Germany, Poland and Ukraine. There are discussed his works concerned with laboratory circuits supporting measurements, including ones for voltage regulation at instrument calibration, for elimination of isolation leakage current impact on measurements, and circuit for the measurement of standard cells and internal resistances of batteries. The main work of prof. Krukowski in the field of high accuracy measuring systems, both the DC and AC, is also discussed. Fundamental work of prof. Krukowski in the field of systems for accurate measurement of standard resistances, DC and AC potentiometers, and an example of a patent for power measurements in three phase circuits are described. Fundamental input to the metrology of prof. Krukowski's works is underlined.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 144-153
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obwód wejściowy układu do pomiaru parametrów napięcia w sieci elektroenergetycznej
The input circuit for the measurement of voltage parameters in a power network
Autorzy:
Rzeszutko, J.
Powiązania:
https://bibliotekanauki.pl/articles/276438.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiary
sieć elektroenergetyczna
measurements
power network
Opis:
W artykule opisano skonstruowany przez autora obwód wejściowy urządzenia służącego do analizy widmowej napięcia elektrycznego w paśmie od 35 Hz do 10 kHz. Przedstawiono etap projektowania obwodów oraz badania właściwości układu. Szczególnie skupiono się na wyznaczeniu charakterystyki amplitudowo-częstotliwościowej członu filtrującego, estymując jego transmitancję przy użyciu widmowych gęstości mocy sygnałów i napięć. Metoda ta umożliwia bardzo dobrą analizę właściwości układu bez konieczności stosowania wyspecjalizowanej aparatury laboratoryjnej. Do estymacji transmitancji użyto wygenerowanego przebiegu prostokątnego o częstotliwości 50 Hz oraz oscyloskopu cyfrowego i komputera. Na podstawie transmitancji wyznaczono charakterystykę członu filtrującego w badanym paśmie częstotliwości.
Abstract - The paper describes the input circuit constructed by the author of for an formed device for the spectral analysis of the voltage in frequency band from 35 Hz to 10 kHz.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 7-8; 58-62
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable-frequency Prony method in the analysis of electrical power quality
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221630.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
Prony method
harmonics
measurements
Opis:
The article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal, are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The proposed modification of least squares Prony method is based on introduction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 39-48
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short time algorithm of power waveforms fundamental harmonic estimation with use of pronys methods
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221769.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
Prony's method
harmonics
measurements
Opis:
This paper presents an example of practical use of Prony's method for monitoring of power waveform fundamental harmonic fluctuations, which is required for the analysis of window synchronizations in frequency analyses in power monitoring systems. The example presented offers verification of the authors' theoretical considerations published earlier in articles about Prony's method and its opportunities for practical use for real life signals. The investigations shown are based on the least squares Prony's method, which, in connection with digital filtrations, enables estimations of fundamental frequency at the rate of even tens of times per one fundamental harmonic period.
Źródło:
Metrology and Measurement Systems; 2011, 18, 3; 371-378
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wieloparametrowe przyrządy do pomiaru wielkości energetycznych
Multifunctions measurement instruments for power systems
Autorzy:
Furmankiewicz, L.
Rybski, R.
Powiązania:
https://bibliotekanauki.pl/articles/157527.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przyrządy wieloparametrowe
pomiary wielkości energetycznych
multifunctions measurements
multifunctions measurements instruments
power systems
Opis:
W artykule przedstawiono przegląd opracowanych w Instytucie Metrologii Elektrycznej i wdrożonych do produkcjiw OBRME METROL w Zielonej Górze przyrządów pomiarowych przeznaczonych do pomiaru parametrów sieci energetycznych i oceny jakości energii elektrycznej. Przedstawiono metody przetwarzania i strukturę przyrządów. Omówiono modele matematyczne obwodów wejściowych, przedstawiono wyniki badań oraz metodę korekcji błędów wnoszonych przez obwody wejściowe.
Sampling instruments capable of measuring multiple electrical parameters in three phase systems are presented in this paper. A software method of correcting an errors that are introduced by measuring transformers on power measurements accuracy with distorted signals also is presents. The method has been implemented in sampling of power meters. result of the method also are shown.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 2/3, 2/3; 41-46
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of a new capacitor bank installation on power quality parameters : an industrial case study
Wpływ przyłączenia nowej baterii kondensatorów na jakość energii elektrycznej : analiza wybranego przypadku przemysłowego
Autorzy:
Wysocki, W.
Powiązania:
https://bibliotekanauki.pl/articles/268691.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii elektrycznej
pomiary
moc bierna
power quality
measurements
reactive power
Opis:
This paper deals with the results of three phase measurements of power quality parameters. The measurements were executed in order to match the new capacitor bank with the operating conditions of a supply station in a small factory near Cracow. The measurements were conducted under rated voltage (three-phase, 230/400V) in the LV switchgear. The main objective of the analysis was to assess power quality during long-term operating conditions both before and after the installation of a new capacitor bank. The analysis also aimed to check the influence of the capacitor bank on power quality and identifying the quantitative benefits of reactive power compensation.
Dokument traktuje o wynikch trójfazowych pomiarów parametrów jakości energii. Pomiary zostały wykonane w celu dostosowania nowej baterii kondensatorów do warunków pracy stacji zasilającej małą fabrykęi w pobliżu Krakowa. Pomiary były wykonywane przy napięciu znamionowym 230/400V w rozdzielnicy głównej nn. Głównym celem przedstawionej analizy wyników jest ocena jakości energii podczas długotrwałych warunków pracy przed i po instalacji nowej baterii kondensatorów, jak również, sprawdzenie jej wpływu na tę jakość energii elektrycznej i przekonanie się o ilościowych korzyściach płynących z kompensacji mocy biernej.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 165-168
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities for determining the interference between a power supply network and a converter fed drive
Autorzy:
Beniak, R.
Gardecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1193393.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
power quality
converter drives
voltage and current measurements
Opis:
Measuring instruments, measurement methods, and an exemplary analysis of the impact of chosen operating stages of the converter drive on the power supply network have been presented. The measurements of electrical and mechanical parameters in drive systems used in industry are complex. The task is difficult due to the necessity of connecting a measuring instrument into electric circuits of an active facility with the use of only short non-operational periods of the device. However, a wellchosen model of a drive system allows the multivariate research of the impact of drive parameters and a control algorithm used on voltage and current harmonic content and performance of the system, and therefore on a simulation analysis of the impact of the drive on the power supply network.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 17-26
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies