Evaluation of the Effect of Uncertainties on the Acoustic Behavior of a Porous Material Located in a Duct Element Using the Monte Carlo Method
Autorzy:
Hannachi, Hanen
Trabelsi, Hassen
Kani, Marwa
Taktak, Mohamed
Chaabane, Mabrouk
Haddar, Mohamed
Powiązania:
https://bibliotekanauki.pl/articles/31339920.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
porous material
physical parameters
transmission loss
acoustic power attenuation
Monte Carlo
method
Opis:
When studying porous materials, most acoustical and geometrical parameters can be affected by the presence of uncertainties, which can reduce the robustness of models and techniques using these parameters. Hence, there is a need to evaluate the effect of these uncertainties in the case of modeling acoustic problems. Among these evaluation methods, the Monte Carlo simulation is considered a benchmark for studying the propagation of uncertainties in theoretical models. In the present study, this method is applied to a theoretical model predicting the acoustic behavior of a porous material located in a duct element to evaluate the impact of each input error on the computation of the acoustic proprieties such as the reflection and transmission coefficients as well as the acoustic power attenuation and the transmission loss of the studied element. Two analyses are conducted; the first one leads to the evaluation of the impacts of error propagation of each acoustic parameter (resistivity, porosity, tortuosity, and viscous and thermal length) through the model using a Monte Carlo simulation. The second analysis presents the effect of propagating the uncertainties of all parameters together. After the simulation of the uncertainties, the 95% confidence intervals and the maximum and minimum errors of each parameter are computed. The obtained results showed that the resistivity and length of the porous material have a great influence on the acoustic outputs of the studied model (transmission and reflection coefficients, transmission loss, and acoustic power attenuation). At the same time, the other physical parameters have a small impact. In addition, the acoustic power attenuation is the acoustic quantity least impacted by the input uncertainties.
Źródło:
Archives of Acoustics; 2023, 48, 1; 81-91
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Loadability maximisation in bilateral network for real-time forecasting system using cuckoo search algorithm
Autorzy:
Venkatasivanagaraju, S.
Rao, M. Venkateswara
Powiązania:
https://bibliotekanauki.pl/articles/38699704.pdf
Data publikacji:
2023
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
optimal power flow
NR method
short-term load forecasting
long-term load forecasting
cuckoo search algorithm
optimisation
loss minimisation
optymalny przepływ mocy
metoda NR
krótkoterminowe prognozowanie obciążeń
długoterminowe prognozowanie obciążeń
algorytm kukułki
optymalizacja
minimalizacja strat
Opis:
This manuscript proposes an optimal power flow (OPF) solution in a coordinated bilateralpower network. The primary goal of this project is to maximise the benefits of the powermarket using Newton–Raphson (NR) and cuckoo search algorithm CSA methodologies.The global solution is found using a CSA-based optimisation approach. The study isconducted on real-time bus system. To avoid this, creative techniques have lately beenused to handle the OPF problem, such as loadability maximisation for real-time predictionsystems employing the CSA. In this work, cuckoo search (CS) is used to optimise theobtained parameters that help to minimise parameters in the predecessor and consequentunits of each sub-model. The proposed approach is used to estimate the power load in thelocal area. The constructed models show excellent predicting performance based on derivedperformance. The results confirm the method’s validity. The outcomes are compared withthose obtained by using the NR method. CSA outperformed the other methods in thisinvestigation and gave more accurate predictions. The OPF problem is solved via CSAin this study. Implementing a real-time data case bus system is recommended to test theperformance of the established method in the MATLAB programme.
Źródło:
Computer Assisted Methods in Engineering and Science; 2023, 30, 1; 73-88
2299-3649
Pojawia się w:
Computer Assisted Methods in Engineering and Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the Effectiveness of Monte Carlo Filtering when Correcting Negative SEA Loss Factors
Autorzy:
Nieradka, Paweł
Dobrucki, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/31339865.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
statistical energy analysis
coupling loss factor
Monte Carlo filtering
power injection method
Opis:
The power injection method (PIM) is an experimental method used to identify the statistical energy analysis (SEA) parameters (called loss factors – LFs) of a vibroacoustic system. By definition, LFs are positive real numbers. However, it is not uncommon to obtain negative LFs during experiments, which is considered a measurement error. To date, a recently proposed method, called Monte Carlo filtering (MCF), of correcting negative coupling loss factors (CLFs) has been validated for systems that meet SEA assumptions. In this article, MCF was validated for point connections and in conditions where SEA assumptions are not met (systems with low modal overlap, non-conservative junctions, strong coupling). The effect of removing MCF bias on the results was also examined. During the experiments, it was observed that the bias is inversely proportional to the damping loss factor of the examined subsystems. The obtained results confirm that the PIM, combined with MCF, allows to determine non-negative SEA parameters in all considered cases.
Źródło:
Archives of Acoustics; 2023, 48, 3; 201-218
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic based evaluation of DGs in capacitor allocated optimal distribution network
Autorzy:
Srinivasan, G.
Amaresh, K.
Cheepati, Kumar Reddy
Powiązania:
https://bibliotekanauki.pl/articles/2173535.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ISSOT-WF
capacitor placement
capacitor sizing
feeder reconfiguration
dispersed generation
electrical distribution network
additional power loss reduction
rozmieszczenie kondensatorów
wymiarowanie kondensatorów
rekonfiguracja podajnika
generacja rozproszona
sieć dystrybucji energii
redukcja strat mocy
Opis:
Feeder reconfiguration (FR), capacitor placement and sizing (CPS) are the two renowned methods widely applied by the researchers for loss minimization with node voltage enrichment in the electrical distribution network (EDN), which has an immense impact on economic savings. In recent years, optimization of FR and CPS together can proficiently yield better power loss minimization and save costs compared to the individual optimization of FR and CPS. This work proposes an application of an improved salp swarm optimization technique based on weight factor (ISSOT-WF) to solve the cost-based objective function using CPS with and without FR for five different cases and three load levels, subject to satisfying operating constraints. In addition, to ascertain the impact of real power injection on additional power loss reduction, this work considers the integration of dispersed generation units at three optimal locations in capacitive compensated optimal EDN. The effectiveness of ISSOT-WF has been demonstrated on the standard PG&E-69 bus system and the outcomes of the 69-bus test case have been validated by comparing with other competing algorithms. Using FR and CPS at three optimal nodes and due to power loss reduction, cost-saving reached up to a maximum of 71%, and a maximum APLR of 26% was achieved after the installation of DGs at three optimal locations with the significant improvement in the bus voltage profile.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 1; e139053, 1--10
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel merchant optimization algorithm for solving optimal reactive power problem
Autorzy:
Lenin, Kanagasabai
Powiązania:
https://bibliotekanauki.pl/articles/1837360.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optimal reactive power
transmission loss
merchant optimization algorithm
Opis:
In this paper Merchant Optimization Algorithm (MOA) is proposed to solve the optimal reactive power problem. Projected algorithm is modeled based on the behavior of merchants who gain in the market through various mode and operations. Grouping of the traders will be done based on their specific properties, and by number of candidate solution will be computed to individual merchant. First Group named as “Ruler candidate solution” afterwards its variable values are dispersed to the one more candidate solution and it named as “Serf candidate solution” In standard IEEE 14, 30, 57 bus test systems Merchant Optimization Algorithm (MOA) have been evaluated. Results show the proposed algorithm reduced power loss effectively.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2021, 15, 1; 51-56
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research and Solution Proposals to Optimize Distribution Power Grids in Smart Grid Condition
Autorzy:
Pham, Trung Son
Nguyen, Dinh Tien
Nguyen, Quang Thuan
Dang, Quang Khoa
Powiązania:
https://bibliotekanauki.pl/articles/2020237.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
smart grid
power loss
energy loss
optimization
distribution power grids
strata energii
optymizacja
dystrybucja
Opis:
Smart Grid is a concept for transforming the electric power grid by using advanced automatic control and communications techniques and other forms of information technology. It integrates innovative tools and technologies from: generation, transmission and distribution. This also includes consumer appliances and equipment. This concept integrates energy infrastructure, processes, devices, information and markets into a coordinated and collaborative process. All allowing energy to be generated, distributed and consumed flexibly and efficiently. However, the Smart Grid with the integration of distributed generation itself also creates a several disadvantages. There can be problems with: stability and reliability, relay protection, isolation and operational isolation in which the problem is to create a burden on the distribution grid when transmitting electrical energy sources. Optimizing power flow and bringing high operating efficiency on Smart Grid conditions is an urgent issue. This paper focuses on researching and proposing solutions for optimal calculation of power flow on Smart Grid. The paper has researched, and analyzed calculation solutions to optimize power flow and proposed to use the Lagrange multiplier method. The study performed calculations for a typical Smart Grid model with three distributed generations. Calculation results have shown that the role of the method is to fully perform the optimal calculation of the power flow on the grid. This is in order to reduce power loss and energy loss as well as increasing operational efficiency while improving power quality in Smart Grid conditions.
Źródło:
Inżynieria Mineralna; 2021, 2; 479--486
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of smart transformer on different radialdistribution systems
Autorzy:
Mahmoud, Ibrahem Mohamed A.
Abdelsalam, Tarek Saad
Swief, Rania
Powiązania:
https://bibliotekanauki.pl/articles/1841278.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
smart transformer
smart grid
direct approach
power flow
power loss reduction
inteligentny transformator
inteligentna sieć
bezpośrednie podejście
przepływ mocy
redukcja strat mocy
Opis:
The work is intended to extend the application of a smart transformer on a radialdistribution system. In this paper, an updated algorithm on the backward/forward powerflow is introduced. The so-called direct approach of power flow is employed and analyzed.In addition, the paper focused on integrating a smart transformer to the network and solvingthe updating network also using the direct approach load flow. The solution of the smarttransformer using the direct approach power flow method is quite straightforward. Thismodel is applied to radial distribution systems which are the IEEE 33- and IEEE 69-bussystems as a case study. Also, the paper optimizes the best allocation of the smart transformerto reduce the power losses of the grid.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 271-283
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Trade based on alliance chain in energy from distributed photovoltaic grids
Autorzy:
Ding, Ran
Feng, Chaohan
Wang, Dongsheng
Sun, Rongfu
Wang, Longyang
Yuan, Shaojun
Powiązania:
https://bibliotekanauki.pl/articles/1841289.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
alliance chain
distributed photovoltaic grid
power transmission loss
pricing strategy
łańcuch sojuszu
rozproszona sieć fotowoltaiczna
straty w przenoszeniu mocy
polityka cenowa
Opis:
With the rapid development of distributed photovoltaic grids, more and more users join the power sales side, and the traditional power grid operation mode is no longer applicable. This paper analyzes the characteristics of the distributed photovoltaic grid under overload conditions, and further summarizes the problems that the distributed photovoltaic grid will face under these conditions. To solve these problems, the alliance chain technology was introduced into the distributed photovoltaic grid. At the same time, this paper establishes a photovoltaic pricing strategy that considers power transmission loss. Finally, the feasibility of the theory is verified by constructing a virtual model.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 325-336
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power loss reduction by novel feral cat swarm optimization algorithm
Autorzy:
Lenin, Kanagasabai
Powiązania:
https://bibliotekanauki.pl/articles/384742.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optimal reactive power
Transmission loss
Feral Cat Swarm Optimization Algorithm
Opis:
In this paper Feral Cat Swarm Optimization (FCS) Algorithm is proposed to solve optimal reactive power problem. Projected methodology has been modeled based on the activities of the feral cats. They have two main phases primarily “seeking mode”, “tracing mode”. In the proposed FCS algorithm, population of feral cats are created and arbitrarily scattered in the solution space, with every feral cat representing a solution. Produced population is alienated into two subgroups. One group will observe their surroundings which come under the seeking mode and another group moving towards the prey which will come under the tracing mode. New-fangled positions, fitness functions will be calculated subsequent to categorization of feral cats for seeking mode and tracing mode, through that cat with the most excellent solution will be accumulated in the memory. Feral Cat Swarm Optimization (FCS) Algorithm has been tested in standard IEEE 30 bus test system and simulation results show the projected algorithm reduced the real power loss considerably.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2020, 14, 2; 25-29
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of sound power transmission within duct systems
Autorzy:
Strek, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2146600.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
transmission loss
finite element method
dimensionless acoustic equations
sound power
izolacyjność akustyczna
metoda elementów skończonych
moc akustyczna
Opis:
External boundaries of acoustic devices can channel sound propagation, and in some cases can create buildup or attenuation of acoustic energy within a confined space. In this paper, it is proposed an efficient practical numerical method (based on FEM) of calculation of attenuation of sound power transmission through ducts. The method shows its viability by presenting the reasonably consistent anticipation of the experimental result. One can observe the mechanical behaviour of the duct’s medium for lower frequencies (high transmission loss) and wave behaviour for higher frequencies (small or zero attenuation). The authors proved that mechanical vibrations of medium reduce the possibility of acoustic energy transmission in duct systems. The radiation impedance for the duct is calculated as well.
Źródło:
Vibrations in Physical Systems; 2020, 31, 3; art. no. 2020320
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance evaluation of ZVS/ZCS high efficiency AC/DC converter for high power applications
Autorzy:
Ali, A.
Chuanwen, J.
Khan, M. M.
Habib, S.
Ali, Y.
Powiązania:
https://bibliotekanauki.pl/articles/200472.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
switching losses
zero current switching
zero voltage switching
power quality
reverse recovery loss
Opis:
The increased power density, reduced switching losses with minimum electromagnetic interference (EMI), and high efficiency are essential requirements of power converters. To achieve these characteristics, soft power converters employing soft switching techniques are indispensable. In this paper, a ZCS/ZVS PWM AC/DC converter topology has been emphasized, which finds applications in high power systems such as automobile battery charging and renewable energy systems. This converter scheme maintains zero current and zero voltage switching conditions at turn on and turn off moments of semiconductor switches, respectively and soft operation of rectifier diodes that lead to negligible switching and diode reverse recovery losses. Moreover, it improves power quality and presents high input power factor, low total harmonic distortion of the input current (THDI ) and improved efficiency. The validity of theoretical analysis of the proposed converter has been carried out experimentally on a 10 kW laboratory prototype. Experimental results prove that the soft switching operation of the semiconductor switches and diodes is maintained at 98.6% rated load efficiency. In addition, the performance evaluation has been performed by comparative analysis of the proposed converter with some prior art high power AC/DC converters. Efficiencies of the proposed and prior art high power topologies have been determined for different load conditions. The highest efficiency, power factor and lower THDI of the proposed converter topology complies with international standards.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 793-807
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Timber wolf optimization algorithm for real power loss diminution
Autorzy:
Lenin, Kanagasabai
Powiązania:
https://bibliotekanauki.pl/articles/950973.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
TWO algorithm
optimal reactive power
transmission loss
Timber Wolf optimization algorithm
Opis:
In this paper Timber Wolf optimization (TWO) algorithm is proposed to solve optimal reactive power problem. Timber Wolf optimization (TWO) algorithm is modeled based on the social hierarchy and hunting habits of Timber wolf towards finding prey. Based on their fitness values social hierarchy has been replicated by classifying the population of exploration agents. Exploration procedure has been modeled by imitating the hunting actions of timber wolf by using searching, encircling, and attacking the prey. There are three fittest candidate solutions embedded as α, β and γ to lead the population toward capable regions of the exploration space in each iteration of Timber Wolf optimization. Proposed Timber Wolf optimization (TWO) algorithm has been tested in standard IEEE 14, 30 bus test systems and simulation results show the projected algorithm reduced the real power loss efficiently.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2020, 14, 1; 24-28
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielopoziomowe przekształtniki energoelektroniczne - topologie, zasada działania, metody modulacji
Multilevel power electronic converters - topologies, operation, modulation methods
Autorzy:
Czmil, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2015051.pdf
Data publikacji:
2020
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
przekształtniki energoelektroniczne
układy topologiczne
sterowanie
struktura działania
metody modulacji
analiza strat mocy przekształtników
power electronic converters
topology control
operation
modulation methods
power loss analysis
Opis:
W artykule zostały omówione wybrane zagadnienia dotyczące budowy topologicznej, sposobu działania i sterowania oraz metod modulacji stosowanych w przekształtnikach wielopoziomowych. Dokonano przeglądu podstawowych topologii przekształtników wielopoziomowych, do których zalicza się przekształtniki z diodami poziomującymi, przekształtniki z kondensatorami poziomującymi, przekształtniki kaskadowe oraz przekształtniki hybrydowe. Opisano ogólną strukturę działania przekształtnika wielopoziomowego składającą się z kilku etapów w zależności od jego zastosowania i topologii. W strukturze działania wyszczególniono etapy zewnętrznej pętli sterowania, wewnętrznej pętli sterowania, stabilizacji napięć DC oraz modulacji. Następnie zaprezentowano podział metod modulacji stosowanych w przekształtnikach wielopoziomowych i dokonano szczegółowego opisu wybranych metod modulacji. W dalszej części artykułu zostały szczegółowo opisane metody modulacji, tj. metoda z sygnałami nośnymi z przesuniętymi poziomami oraz metoda z sygnałami nośnymi przesuniętymi fazowo posłużyły do przedstawienia analizy strat mocy w przekształtnikach wielopoziomowych.
In this paper selected issues concerning topological structure, operation and control as well as modulation methods used in multilevel converters are presented. There is reviewed general topologies of multilevel converters, which include Diode-Clamped Converters, Capacitor-Clamped Converters, Cascade Converters and Hybrid Converters. The general structure of a multilevel converter consisting of several stages depending on its application and topology is described. In the structure of operation, the stages of Outer Control Loop, Inner Control Loop, DC voltage stabilization and modulation are specified. Next, the division of modulation methods used in multilevel converters is presented and a detailed description of selected modulation methods is made. In the further part of the article the modulation methods were described in detail, i.e. the Level-Shifted Carrier Modulation Technique and Phase-Shifted Carrier Modulation Technique were used to present the analysis of power losses in multilevel converters.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Elektrotechnika; 2020, 38 [301], 1-2; 5-18
0209-2662
2300-6358
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Elektrotechnika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Continuously variable transmission leakage test results
Autorzy:
Goszczak, Jarosław
Radzymiński, Bartosz
Mitukiewicz, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/105918.pdf
Data publikacji:
2019
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
passenger car‘s driveline
power loss
efficiency improvement
continuously variable transmission
hydraulic control system
leakage values
układ napędowy samochodu osobowego
strata mocy
poprawa wydajności
przekładnia bezstopniowa
hydrauliczne układy sterowania
Opis:
After a short introduction characterizing the general outline of the issue, this paper describes the test results of oil leakage measurements through CVT actuator seals. The research was done using Jatco company's CVT 7model, the popular gearbox for small passenger cars. Several curves of leakage values are given for both actuators, concerning different conditions such as rotational speed, oil temperature or pressure. In the summary several conclusions are formulated, based on presented test results. The determined maximal value of leakage is about 1 l/min. It emerged that the influence of centrifugal force is negligible. What is more, the observed phenomena are shortly described and projected for more detailed investigation.
Źródło:
Acta Innovations; 2019, 31; 5-13
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the importance factors of the power plants within the power system reliability evaluation
Ocena współczynników ważności elektrowni w ramach oceny niezawodności systemu elektroenergetycznego
Autorzy:
Čepin, Marko
Powiązania:
https://bibliotekanauki.pl/articles/300987.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
power plant
reliability
importance
loss of load expectation
network
elektrownia
niezawodność
ważność
oczekiwany czas niepokrycia zapotrzebowania
sieć
Opis:
The objective of the paper is to develop the reliability importance factors which could identify the plants, which more or less contribute to the increased or decreased power system reliability. One group of importance factors could identify the plants, which with their increased availability would notably increase the power system reliability The other group of the importance factors could identify the plants, which with their reduced availability would notably reduce the power system reliability. The importance factors have been developed. An example of regional power system was considered for the case study. The results identify the power plants which are more susceptible to increase of the loss of load expectation and thus to decreasing of the power system reliability, if their availability is reduced. Similarly, the results identify the power plants which are more susceptible to decreasing of the loss of load expectation and thus to increase of the power system reliability, if their availability is increased. The lists of important factors can serve as a standpoint for inclusion of the power system reliability role within the power system to the planning activities. The lists of importance factors can represent the standpoint for the power system operator to reward the improvement of the power plant availability or to penalize the reduced power plant availability.
Celem artykułu jest opracowanie współczynników ważności niezawodności, pozwalających identyfikować elektrownie, które w mniejszym lub większym stopniu przyczyniają się do zwiększenia lub zmniejszenia niezawodności systemu elektroenergetycznego. Opracowano dwie grupy takich współczynników: jedne – służące do identyfikacji elektrowni, które przy zwiększonej gotowości mogą znacznie zwiększać niezawodność systemu elektroenergetycznego, i drugie – do identyfikacji tych elektrowni, których zmniejszona gotowość może znacznie zmniejszać niezawodność sieci elektroenergetycznej. Jako studium przypadku rozważano przykład regionalnego systemu elektroenergetycznego. Wyniki pozwalają na wskazanie elektrowni, które są bardziej podatne na zwiększenie oczekiwanego czasu deficytu mocy (niepokrycia zapotrzebowania), a tym samym mogą bardziej przyczyniać się do zmniejszenia niezawodności systemu elektroenergetycznego, w przypadku spadku ich gotowości. Podobnie, uzyskane wyniki pozwalają ustalić, dla których elektrowni prawdopodobieństwo zmniejszenia oczekiwanego czasu deficytu mocy jest większe, a tym samym, które elektrownie mogą bardziej przyczyniać się do zwiększenia niezawodności systemu elektroenergetycznego, gdy zwiększy się ich gotowość. Listy współczynników ważności mogą służyć jako punkt odniesienia dla działań planistycznych, a także jako podstawa dla operatora systemu elektroenergetycznego do nagradzania poprawy gotowości elektrowni lub penalizacji jej spadku.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 4; 631-637
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies