Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power loss" wg kryterium: Temat


Tytuł:
3D loss and heat analysis at the end region of 4-poles 1150 MW nuclear power turbine generator
Autorzy:
Zhou, G.
Han, L.
Fan, Z
Liao, Y.
Huang, S.
Powiązania:
https://bibliotekanauki.pl/articles/950663.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
loss and heat
end region
4-poles nuclear power turbine generator
electromagnetic field
temperature field
Opis:
To study the principle of loss and heat at the end region of large 4-poles nuclear power turbine generator, 3D transient electromagnetic field and 3D steady temperature field finite element (FE) models of the end region are established respectively. Considering the factors such as rotor motion, core non-linearity and time-varying of electromagnetic field, the anisotropic heat conductivity and different heat dissipation conditions of stator end region, a 50 Hz, 1150 MW, 4-poles nuclear power turbine generator is investigated. The loss and heat at the generator end region are calculated respectively at no-load and rated-load, and the calculation results are compared with the test data. The result shows that the calculation model is accurate and the generator design is suitable. The method is valuable for the research of loss and heat at the end region of large 4-poles nuclear power turbine generator and the improvement of the generator’s operation stability. The method has been applied successfully for the design of the larger nuclear power turbine generators.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 47-61
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A hybridized approach for design and optimization of ORPD under unbalanced conditions
Autorzy:
Shareef, S. M.
Rao, R. S.
Powiązania:
https://bibliotekanauki.pl/articles/1839102.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
ORPD
power loss
voltage profile
Cuckoo Search
Glow Worm Swarm
Opis:
The issue of ORPD (Optimal Reactive Power Dispatch) for enhancing security and economy of a power system has been given substantial consideration in recent days. The major inspiration behind deploying an ORPD system for enhancing power system efficiency is to reallocate the RP (reactive power) in such a manner that power loss be minimized, and voltage profiles get enhanced. Hence, this paper concerns the major objectives, namely, reduction of power loss and voltage deviation that are related to solving ORPD problem under unbalanced condition. To attain these objectives, an amalgamation of two algorithms, called CS (Cuckoo Search) and GWSO (Glow Worm Swarm), is adopted for optimizing, and hence the proposed model is referred to as CP-GWSO. This algorithm functions with the control parameters, namely load reactance, voltage and transformer tap settings that are tuned to attain the optimum outcome. The entire empirical part of the investigations is performed on two IEEE standard test bus systems, the IEEE 14 and the IEEE 39 bus systems. Finally, the proposed scheme is compared to the conventional methods, and its efficiency is confirmed.
Źródło:
Control and Cybernetics; 2018, 47, 4; 309-328
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel merchant optimization algorithm for solving optimal reactive power problem
Autorzy:
Lenin, Kanagasabai
Powiązania:
https://bibliotekanauki.pl/articles/1837360.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optimal reactive power
transmission loss
merchant optimization algorithm
Opis:
In this paper Merchant Optimization Algorithm (MOA) is proposed to solve the optimal reactive power problem. Projected algorithm is modeled based on the behavior of merchants who gain in the market through various mode and operations. Grouping of the traders will be done based on their specific properties, and by number of candidate solution will be computed to individual merchant. First Group named as “Ruler candidate solution” afterwards its variable values are dispersed to the one more candidate solution and it named as “Serf candidate solution” In standard IEEE 14, 30, 57 bus test systems Merchant Optimization Algorithm (MOA) have been evaluated. Results show the proposed algorithm reduced power loss effectively.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2021, 15, 1; 51-56
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on the effect of harmonie components of the current supplying an induction motor with reactive power compensation with the use of capacitors on the power loss and voltage variations
Autorzy:
Nawrowski, R.
Stein, Z.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/97224.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
induction motor
current and voltage harmonics
power loss compensation
Opis:
The paper presents an analysis of the effect of voltage harmonics on the power loss in an LV line supplying an induction motor with reactive power compensation, with the use of capacitors, and analysis of the values of output voltage of an MV/LV transformer depending on the load type and value.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 275-287
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power loss reduction by novel feral cat swarm optimization algorithm
Autorzy:
Lenin, Kanagasabai
Powiązania:
https://bibliotekanauki.pl/articles/384742.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optimal reactive power
Transmission loss
Feral Cat Swarm Optimization Algorithm
Opis:
In this paper Feral Cat Swarm Optimization (FCS) Algorithm is proposed to solve optimal reactive power problem. Projected methodology has been modeled based on the activities of the feral cats. They have two main phases primarily “seeking mode”, “tracing mode”. In the proposed FCS algorithm, population of feral cats are created and arbitrarily scattered in the solution space, with every feral cat representing a solution. Produced population is alienated into two subgroups. One group will observe their surroundings which come under the seeking mode and another group moving towards the prey which will come under the tracing mode. New-fangled positions, fitness functions will be calculated subsequent to categorization of feral cats for seeking mode and tracing mode, through that cat with the most excellent solution will be accumulated in the memory. Feral Cat Swarm Optimization (FCS) Algorithm has been tested in standard IEEE 30 bus test system and simulation results show the projected algorithm reduced the real power loss considerably.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2020, 14, 2; 25-29
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wybranych odnawialnych źródeł energii na straty mocy czynnej i biernej w systemie elektroenergetycznym
Impact of the selected renewable energy sources on active and reactive power losses in a power system
Autorzy:
Tarakan, B.
Tarakan, K.
Zajczyk, R.
Czapp, S.
Sarnicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266608.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odnawialne źródła energii
OZE
farma fotowoltaiczna
farmy wiatrowe
straty mocy czynnej
straty mocy biernej
renewable energy sources
photovoltaic farm
wind farms
loss of active power
loss of reactive power
Opis:
Moc zainstalowana oraz produkcja energii elektrycznej z odnawialnych źródeł energii od kilkunastu lat systematycznie w Polsce wzrasta. Należy spodziewać się, że tendencja ta w najbliższych latach zostanie utrzymana. Dość dużym zainteresowaniem cieszą się źródła wiatrowe oraz źródła fotowoltaiczne, co sprawia, że przy znacznych ich mocach zainstalowanych konieczne staje się badanie wpływu tych źródeł na system elektroenergetyczny. W artykule przedstawiono analizę wpływu farmy fotowoltaicznej i farmy wiatrowej na poziom strat mocy czynnej i biernej w systemie elektroenergetycznym. Obliczenia wykonano z wykorzystaniem programu DIgSILENT PowerFactory.
The rated power and the production of energy from renewable energy sources for several years steadily increases in Poland. It is expected that this trend will be continued in the coming years. Wind and photovoltaic sources are very popular and in consequence it becomes necessary to study the impact of these sources on the power system. The article presents an analysis of the impact of photovoltaic farm and wind farm on the level of loss of active and reactive power in the power system. Calculations were performed with the use of DIgSILENT PowerFactory software.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of induced voltages and power losses in high voltage power cables for selected methods of cables sheaths bonding
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
Autorzy:
Czapp, S.
Dobrzyński, K.
Klucznik, J.
Lubośny, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397047.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
power cable
induced voltage
power loss
kabel elektroenergetyczny
napięcie indukowane
strata mocy
Opis:
Power is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s outer non-conductive sheath. These voltages depend on the earthing/bonding of the cable’s sheaths, and on the cable configuration. These voltages induce currents, which, in turn, cause additional power losses in the cable. The article presents multivariate analysis of the voltages induced in a selected cable line in steadystate condition. Single-point bonding of sheaths has been discussed, as well as their both-ends bonding, transposition, and transposition of cores (conductors). For each case, the losses of active power in this line have been calculated.
Streszczenie Dostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu uziemienia żył powrotnych kabli oraz konfiguracji kabli. Konsekwencją napięć indukowanych są prądy indukowane, a te z kolei są przyczyną dodatkowych strat mocy w kablach. W artykule przedstawiono wielowariantową analizę napięć indukowanych w wybranej linii kablowej. Rozpatrzono uziemienie jednostronne żył powrotnych, uziemienie dwustronne żył powrotnych, transpozycję żył powrotnych oraz transpozycję żył roboczych. Dla każdego z przypadków obliczono straty mocy czynnej w tej linii.
Źródło:
Acta Energetica; 2017, 2; 29-35
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antitrust Damages Actions in Ukraine: Current Situation and Perspectives
Autorzy:
Gerasymenko, Anzhelika
Mazaraki, Nataliia
Powiązania:
https://bibliotekanauki.pl/articles/530348.pdf
Data publikacji:
2015-12-31
Wydawca:
Uniwersytet Warszawski. Wydawnictwo Naukowe Wydziału Zarządzania
Tematy:
antitrust damages actions
private antitrust enforcement
harm from antitrust infringement
non-infringement scenario
economic effect of cease of antitrust infringements
welfare loss from market power
Opis:
The article gives an overview of Ukrainian legislation and experiences concerning antitrust damages actions. The analysis has led to a number of conclusions: private claims are rare in Ukraine due to difficulties in obtaining evidence, high legal costs, and lacking confidence in the Ukrainian court system. The paper gives examples of Ukrainian private antitrust enforcement practice and provides a statistical analysis of the dynamics of ‘compensated’ damages caused by antitrust infringements in Ukraine. The value of ‘compensated’ damages is compared to the value of the economic effect of stopping antitrust infringements, as well as to the value of the overall welfare loss deriving from market power in the national economy. Finally, some new sources of damages caused by market power are discussed considering the development perspectives of this branch of antitrust activity.
Źródło:
Yearbook of Antitrust and Regulatory Studies; 2015, 8(12); 195-214
1689-9024
2545-0115
Pojawia się w:
Yearbook of Antitrust and Regulatory Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Continuously variable transmission leakage test results
Autorzy:
Goszczak, Jarosław
Radzymiński, Bartosz
Mitukiewicz, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/105918.pdf
Data publikacji:
2019
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
passenger car‘s driveline
power loss
efficiency improvement
continuously variable transmission
hydraulic control system
leakage values
układ napędowy samochodu osobowego
strata mocy
poprawa wydajności
przekładnia bezstopniowa
hydrauliczne układy sterowania
Opis:
After a short introduction characterizing the general outline of the issue, this paper describes the test results of oil leakage measurements through CVT actuator seals. The research was done using Jatco company's CVT 7model, the popular gearbox for small passenger cars. Several curves of leakage values are given for both actuators, concerning different conditions such as rotational speed, oil temperature or pressure. In the summary several conclusions are formulated, based on presented test results. The determined maximal value of leakage is about 1 l/min. It emerged that the influence of centrifugal force is negligible. What is more, the observed phenomena are shortly described and projected for more detailed investigation.
Źródło:
Acta Innovations; 2019, 31; 5-13
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distributed generation’s integration planning involving growth load models by means of genetic algorithm
Autorzy:
Rahman, Y. A.
Manjang, S.
Yusran, A.
Ilham, A.
Powiązania:
https://bibliotekanauki.pl/articles/141167.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed generation
genetic algorithm
load models
power loss
load growth
Opis:
The growth in the system load accompanied by an increase of power loss in the distribution system. Distributed generation (DG) is an important identity in the electric power sector that substantially overcomes power loss and voltage drop problems when it is coordinated with a location and size properly. In this study, the DG integration into the network is optimally distributed by considering the load conditions in different load models used to surmount the impact of load growth. There are five load models tested namely constant, residential, industrial, commercial and mixed loads. The growth of the electrical load is modeled for the base year up to the fifth year as a short-term plan. Minimization of system power loss is taken as the main objective function considering voltage limits. Determination of the location and size of DG is optimally done by using the breeder genetic algorithm (BGA). The proposed studies were applied to the IEEE 30 radial distribution system with single and multiple placement DG scenarios. The results indicated that installing an optimal location and size DG could have a strong potential to reduce power loss and to secure future energy demand of load models. Also, commercial load requires the largest DG active injection power to maintain the voltage value within tolerable limits up to five years.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 667--682
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic based evaluation of DGs in capacitor allocated optimal distribution network
Autorzy:
Srinivasan, G.
Amaresh, K.
Cheepati, Kumar Reddy
Powiązania:
https://bibliotekanauki.pl/articles/2173535.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ISSOT-WF
capacitor placement
capacitor sizing
feeder reconfiguration
dispersed generation
electrical distribution network
additional power loss reduction
rozmieszczenie kondensatorów
wymiarowanie kondensatorów
rekonfiguracja podajnika
generacja rozproszona
sieć dystrybucji energii
redukcja strat mocy
Opis:
Feeder reconfiguration (FR), capacitor placement and sizing (CPS) are the two renowned methods widely applied by the researchers for loss minimization with node voltage enrichment in the electrical distribution network (EDN), which has an immense impact on economic savings. In recent years, optimization of FR and CPS together can proficiently yield better power loss minimization and save costs compared to the individual optimization of FR and CPS. This work proposes an application of an improved salp swarm optimization technique based on weight factor (ISSOT-WF) to solve the cost-based objective function using CPS with and without FR for five different cases and three load levels, subject to satisfying operating constraints. In addition, to ascertain the impact of real power injection on additional power loss reduction, this work considers the integration of dispersed generation units at three optimal locations in capacitive compensated optimal EDN. The effectiveness of ISSOT-WF has been demonstrated on the standard PG&E-69 bus system and the outcomes of the 69-bus test case have been validated by comparing with other competing algorithms. Using FR and CPS at three optimal nodes and due to power loss reduction, cost-saving reached up to a maximum of 71%, and a maximum APLR of 26% was achieved after the installation of DGs at three optimal locations with the significant improvement in the bus voltage profile.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 1; e139053, 1--10
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficient Performance and Lower Complexity of Error Control Schemes for WPAN Bluetooth Networks
Autorzy:
El-Bendary, M. A. M.
El-Tokhy, M. A. R.
Powiązania:
https://bibliotekanauki.pl/articles/308324.pdf
Data publikacji:
2014
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
Bluetooth
EDR
packet loss
power efficiency
Wireless Personal Area Network
Opis:
This paper presents a new technique of reduction retransmission time by decreasing the discarded packets and combating the complexity through error control techniques. The work is based on Bluetooth, one of the most common Wireless Personal Area Network. Its early versions employ an expurgated Hamming code for error correction. In this paper, a new packet format using different error correction coding scheme and new formats for the EDR Bluetooth packets are presented. A study for the Packet Error Probability of classic and Enhanced Data Rate (EDR) packets is also presented to indicate the performance. The simulation experiments are performed over Additive White Gaussian Noise (AWGN) and Rayleigh flat-fading channels. The experimental results reveal that the proposed coding scheme for EDR packets enhances the power efficiency of the Bluetooth system and reduce the losses of EDR packets.
Źródło:
Journal of Telecommunications and Information Technology; 2014, 4; 100-107
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Effect of Uncertainties on the Acoustic Behavior of a Porous Material Located in a Duct Element Using the Monte Carlo Method
Autorzy:
Hannachi, Hanen
Trabelsi, Hassen
Kani, Marwa
Taktak, Mohamed
Chaabane, Mabrouk
Haddar, Mohamed
Powiązania:
https://bibliotekanauki.pl/articles/31339920.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
porous material
physical parameters
transmission loss
acoustic power attenuation
Monte Carlo
method
Opis:
When studying porous materials, most acoustical and geometrical parameters can be affected by the presence of uncertainties, which can reduce the robustness of models and techniques using these parameters. Hence, there is a need to evaluate the effect of these uncertainties in the case of modeling acoustic problems. Among these evaluation methods, the Monte Carlo simulation is considered a benchmark for studying the propagation of uncertainties in theoretical models. In the present study, this method is applied to a theoretical model predicting the acoustic behavior of a porous material located in a duct element to evaluate the impact of each input error on the computation of the acoustic proprieties such as the reflection and transmission coefficients as well as the acoustic power attenuation and the transmission loss of the studied element. Two analyses are conducted; the first one leads to the evaluation of the impacts of error propagation of each acoustic parameter (resistivity, porosity, tortuosity, and viscous and thermal length) through the model using a Monte Carlo simulation. The second analysis presents the effect of propagating the uncertainties of all parameters together. After the simulation of the uncertainties, the 95% confidence intervals and the maximum and minimum errors of each parameter are computed. The obtained results showed that the resistivity and length of the porous material have a great influence on the acoustic outputs of the studied model (transmission and reflection coefficients, transmission loss, and acoustic power attenuation). At the same time, the other physical parameters have a small impact. In addition, the acoustic power attenuation is the acoustic quantity least impacted by the input uncertainties.
Źródło:
Archives of Acoustics; 2023, 48, 1; 81-91
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the importance factors of the power plants within the power system reliability evaluation
Ocena współczynników ważności elektrowni w ramach oceny niezawodności systemu elektroenergetycznego
Autorzy:
Čepin, Marko
Powiązania:
https://bibliotekanauki.pl/articles/300987.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
power plant
reliability
importance
loss of load expectation
network
elektrownia
niezawodność
ważność
oczekiwany czas niepokrycia zapotrzebowania
sieć
Opis:
The objective of the paper is to develop the reliability importance factors which could identify the plants, which more or less contribute to the increased or decreased power system reliability. One group of importance factors could identify the plants, which with their increased availability would notably increase the power system reliability The other group of the importance factors could identify the plants, which with their reduced availability would notably reduce the power system reliability. The importance factors have been developed. An example of regional power system was considered for the case study. The results identify the power plants which are more susceptible to increase of the loss of load expectation and thus to decreasing of the power system reliability, if their availability is reduced. Similarly, the results identify the power plants which are more susceptible to decreasing of the loss of load expectation and thus to increase of the power system reliability, if their availability is increased. The lists of important factors can serve as a standpoint for inclusion of the power system reliability role within the power system to the planning activities. The lists of importance factors can represent the standpoint for the power system operator to reward the improvement of the power plant availability or to penalize the reduced power plant availability.
Celem artykułu jest opracowanie współczynników ważności niezawodności, pozwalających identyfikować elektrownie, które w mniejszym lub większym stopniu przyczyniają się do zwiększenia lub zmniejszenia niezawodności systemu elektroenergetycznego. Opracowano dwie grupy takich współczynników: jedne – służące do identyfikacji elektrowni, które przy zwiększonej gotowości mogą znacznie zwiększać niezawodność systemu elektroenergetycznego, i drugie – do identyfikacji tych elektrowni, których zmniejszona gotowość może znacznie zmniejszać niezawodność sieci elektroenergetycznej. Jako studium przypadku rozważano przykład regionalnego systemu elektroenergetycznego. Wyniki pozwalają na wskazanie elektrowni, które są bardziej podatne na zwiększenie oczekiwanego czasu deficytu mocy (niepokrycia zapotrzebowania), a tym samym mogą bardziej przyczyniać się do zmniejszenia niezawodności systemu elektroenergetycznego, w przypadku spadku ich gotowości. Podobnie, uzyskane wyniki pozwalają ustalić, dla których elektrowni prawdopodobieństwo zmniejszenia oczekiwanego czasu deficytu mocy jest większe, a tym samym, które elektrownie mogą bardziej przyczyniać się do zwiększenia niezawodności systemu elektroenergetycznego, gdy zwiększy się ich gotowość. Listy współczynników ważności mogą służyć jako punkt odniesienia dla działań planistycznych, a także jako podstawa dla operatora systemu elektroenergetycznego do nagradzania poprawy gotowości elektrowni lub penalizacji jej spadku.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 4; 631-637
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies