Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power generator" wg kryterium: Temat


Tytuł:
Mitigation of the wind generation integration related power quality issues by energy storage
Autorzy:
Kook, K. S.
Liu, Y.
Atcitty, S.
Powiązania:
https://bibliotekanauki.pl/articles/262823.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
wind turbine generator (WTG)
wind farm
Power Quality Energy storage system (ESS)
power flow fluctuation
PSS/E
power system stability
Opis:
The wind power which has been expected to be a promising alternative energy source can bring new challenges when it is connected to the power grid due to the fluctuation nature of the wind and the comparatively new types of its generators. This paper illustrates a possible solution to mitigate these integration issues of the wind power by application of the energy storage to the wind farm in power systems focusing on its short-duration perspective. The simulation model for the Energy Storage System (ESS) connected to the wind farm is implemented using the Power System Simulator for Engineering(PSS/E) which is one of the most widely used program for the power system analysis in US. Employing a sample power system, the control effect of the ESS for mitigating the wind generation related power quality issues by suppressing the power flow fluctuation of the wind farm, and improving power system stability is validated. The counteracting effect of the ESS in the wind farm to the disturbance on the grid is also shown.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 77-82
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power injection control system and experimental model based on manufacturer characteristic curves for a photovoltaic generation system
Autorzy:
Rico, A.
Cadaval, E. R.
Montero, M. I. M.
Powiązania:
https://bibliotekanauki.pl/articles/262582.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
Inverter Current Controller (ICC)
Inverter Reference Current Generator (ICRG)
maximum power point tracking (MPPT)
Photovoltaic Cell (PV Cell)
PV Voltage and PV Current
VI characteristic equations
Opis:
This paper attempts to validate the performance of a power injection control block for Photovoltaic Generation Systems (PVGS). This device uses a control module based on detecting the power injected into the supply by the inverter, instead of measuring the power generated by the PVGS. The performance is evaluated using the concept of Maximum Energy Curve that takes into account both transient and permanent control performance. The paper presents a basic and simple procedure to obtain a model from the manufacturer characteristic curves of the photovoltaic cells. MATLAB Simulink is used as simulation tool to obtain the response of the proposed system to changes in temperature and irradiance.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 69-75
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of fuel type on working parameters of testing combustion micro-engine
Autorzy:
Jankowski, A.
Rusin, M.
Powiązania:
https://bibliotekanauki.pl/articles/244792.pdf
Data publikacji:
2008
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
combustion engines
reciprocating engines
micro power generator
microengine
alternative fuels
Opis:
The choice of appropriate additives to alternative type of fuels determines the basic problem related with diversification of fuels used to the internal-combustion engines. The research micro engine with swept volume of 165 mm3 and the rotational speed reaching 25000 rpm was fuelled with various liquid fuels of the methyl and ethyl alcohol base. To the alcohol, additives were added with various percentage compositions, such like castor oil and nitro methane. In the fuel system the mixer of fuel with air was applied, that permitted on supply with the liquid fuel, but the composition of the fuel-air mixture was controlled with the quantity of supplied air. Registered was the graph of compression pressure in mini combustion chamber, the maximum power and shaft output torque was measured with the different composition fuels supplied to engine. Research proved that not only alcohol type applied as fuel, but also above all percentage participation of additives to the fuels influenced most on the micro engine work parameters. For the same type of alcohol, but with the different additives, the maximum power and the maximum torque differed significantly. For the micro engine of this type, the best fuel was based on the methyl alcohol and has composition of 60% methanol as fuel, 15% nitro methane (CH3NO2) as fuel additive and 25% of lubricant - castor oil. Article presents the design of the power shaft output micro engine, tested fuels, exemplary graphs of compression pressures in mini chamber on the prototype of a miniature power shaft engine, graphs of the rotary torque and of the engine power of supplied with various fuels.
Źródło:
Journal of KONES; 2008, 15, 4; 187-195
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of the ignition and combustion processes in the single compression engine
Autorzy:
Kraszewska, H.
Rusin, M.
Powiązania:
https://bibliotekanauki.pl/articles/244754.pdf
Data publikacji:
2008
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
combustion engines
reciprocating engines
micro power generator
vallar microengine
combustion processes
Opis:
An aim of work was analysing of combustion and ignition processes in chambers with small volume at the use of different sorts of fuels, fuel liquid and air mixtures and fuel gas ones. For experiments, the machine of single compression the cubic capacity of 400 mm3 approx and average piston speeds 4 m/s was used. Investigated physical processes allowed better recognizing processes occurring in miniature- real engines. For the feeding of the machine of single compression, homogeneous mixtures of hydrogen with air, propane with air and mixtures methyl and ethyl alcohol in the stoichiometric relation with air were used. Adequately earlier prepared mixtures warranted the repeatability conditions of the experiment. Experiments effected with the machine of single compression showed small increases of pressure from combustion process. The occurrence this can be explained with significant heat conduction to walls during comparatively long compressing and combustion. In carried research with the machine of single compression with very large ratio surface combustion chamber to its volume, one obtained comparatively low value of the maximum compression pressure. The researches showed that on processes of compression, combustion and ignition, the greater influence had geometry of combustion chamber, average piston speed than sorts applied fuels.
Źródło:
Journal of KONES; 2008, 15, 4; 277-281
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary mocy obciążenia silników elektrycznych z użyciem hamownicy prądu stałego
Measurements of the electrical motor output power with use of a d.c. generator
Autorzy:
Banach, H.
Powiązania:
https://bibliotekanauki.pl/articles/156859.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
moc obciążenia silnika
napięcie indukowane
moc wewnętrzna hamownicy
cechowanie hamownicy
motor output power
generated voltage
d.c. generator mechanical power
d.c. generator calibration
Opis:
W artykule przedstawiono sposób pomiaru mocy obciążenia silnika elektrycznego w oparciu o znajomość strat jałowych i mocy wewnętrznej hamownicy. Pomiary przeprowadza się z użyciem specjalnie wycechowanej hamownicy prądu stałego W pierwszym etapie cechowania hamownicy wyznacza się straty jałowe w funkcji prędkości obrotowej Po = f(n) dla stałej wartości prądu wzbudzenia, natomiast w drugim etapie wyznacza się, wg opracowanej metody, charakterystykę napięcia indukowanego w funkcji prądu twornika Ui = f(Ia) dla jednej bądź kilku obranych prędkości obrotowych. Metoda ta opiera się na pomiarach napięcia na zaciskach twornika przy pracy prądnicowej i przy pracy silnikowej, dla założonych wartości prądu twornika. Wartość napięcia indukowanego jest średnią arytmetyczną z obu pomiarów. Znajomość charakterystyki Ui = f(Ia) dla n = const. bardzo ułatwia wyznaczenie mocy wewnętrzną. Po dodaniu do mocy strat jałowych mocy wewnętrznej, otrzymuje się moc na wale badanego silnika. Wg opracowanej metody sporządzono rodzinę charakterystyk Ui = f(Ia) dla dwóch hamownic o mocach PN =1,5 kW oraz PN =3,5 kW. Opisany sposób pomiaru mocy obciążenia cechuje prostota i dość duża dokładność, co predestynuje go do zastosowań w laboratoriach, szczególnie przy wyznaczaniu sprawności silników elektrycznych metodą bezpośrednią.
The paper presents the measurement method for determining the electric motor output power on the basis of no-load losses and d.c. generator mechanical power. Measurement are taken with use of a special calibrated d.c. generator. In the first calibration step, the no-load losses are measured as a function of the rotational speed at a constant excitation current. In the second step there are determined characteristics of the generated voltage as a function of the rotor current Ui = f(Ia) for one or several rotational speeds. For this purpose the method worked out by the author is applied. It allows determining the curves of the generated voltage in a simple way, without knowledge of the armature winding resistance parameters. The described method is based on measurements of the terminal voltage under motor and generator operation for different values of the armature current. The generated voltage value is the arithmetic average of both measuring results. It is possible to calculate the mechanical power on the basis of the characteristics Ui = f(Ia) at n = const.. The investigated motor output power is a sum of the no-load losses and the mechanical power of the d.c. generator. According to the described method, the set of characteristics Ui = f(Ia) for two d.c. generators of rated power PN =1,5 kW and PN =3,5 kW was determined. The presented method for measuring the output power is simple and its measuring accuracy is satisfactory. It can be applied in research laboratories, especially for determining the efficiency by the direct method.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 5, 5; 310-313
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca regulatora generatora w warunkach sprzyjających powstawaniu lawiny napięcia - wybrane problemy
Autorzy:
Klucznik, J.
Małkowski, R.
Szczeciński, P.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/397002.pdf
Data publikacji:
2009
Wydawca:
ENERGA
Tematy:
regulator generatora
awaria napięcia
stabilizator systemowy
regulacja napięcia
voltage regulator
generator
power system stability
Opis:
W artykule zwrócono uwagę na wybrane zagadnienia związane z pracą wieloparametrowego regulatora generatora w warunkach awarii napięciowej. Przedstawiono wyniki analizy wpływu, tak często pomijanego elementu układu regulatora generatora, jakim jest stabilizator systemowy. Zwrócono uwagę na celowość automatyzacji procesu zaniżania mocy czynnej, dla zwiększenia możliwości generacji mocy biernej. Ponadto, wskazano błędy w strukturze toru głównego regulacji napięcia w przypadku układu z tzw. przejmowaniem sygnałów przez bramki LV i HV.
Źródło:
Acta Energetica; 2009, 1; 51-60
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kompensacji prądowej na pracę generatora przy zmianach napięcia w KSE
Autorzy:
Zajczyk, R.
Szczeciński, P.
Powiązania:
https://bibliotekanauki.pl/articles/396885.pdf
Data publikacji:
2010
Wydawca:
ENERGA
Tematy:
Krajowy System Elektroenergetyczny
generator
kompensacja prądu
National Power System
current compensation
Opis:
Artykuł prezentuje wpływ kompensacji prądowej na wrażliwość zmian mocy biernej generatora przy zmianach napięcia w sieci. Wyniki badań przedstawiono dla dwóch różnych sposobów estymacji sygnału od kompensacji prądowej, które pozwalają regulatorowi generatora utrzymywać zadaną wartość napięcia w innym miejscu niż zaciski generatora. W artykule omówiono niezbędne zmiany, które należy wprowadzić w regulacji grupowej ARNE, przy wprowadzeniu kompensacji prądowej w układach regulacji generatorów.
Źródło:
Acta Energetica; 2010, 2; 77-82
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
AC/DC/AC converter in a small hydroelectric power plant
Autorzy:
Sikorski, A.
Korzeniowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200049.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction generator
AC/DC/AC converter
hydroelectric power plant
Opis:
The article discusses application of AC/DC/AC converter cooperating with an induction generator in small hydroelectric power plants. The induction generator works with power grid or a separated group of receivers, enabling to generate power even at low speeds of the turbine. The article provides also results of the investigation concerning the functioning of the generator coupled with AC/DC/AC converter in steady and transient states during start-up and voltage decay.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 507-511
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of power control schemes in dfig for wind energy generation
Analiza porównawcza metod stosowanych do regulacji mocy czynnej i biernej w dwustronnie zasilanym generatorze indukcyjnym
Autorzy:
Jedut, L.
Rosołowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/410545.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wind generation
doubly-fed induction generator
active and reactive power control
stator flux reference frame
Opis:
This paper describes two algorithms applied for active and reactive power control in wind turbine driven doubly fed induction generator (DFIG). The first proposed method applies the PI controllers for regulation of DFIG power and the rotor current while the second one utilizes a difference approximation of a given flux derivative. Both algorithms are based on the model description with reference to the stator flux linkage frame. General description of the analyzed methods is delivered and some results of simulations are included.
W artykule przedstawiona jest analiza dwóch algorytmów stosowanych do regulacji mocy czynnej i biernej w elektrowniach wiatrowych z dwustronnie zasilanymi generatorami indukcyjnymi. W pierwszej rozważanej metodzie stosowane są regulatory PI do kontroli mocy i prądu wirnika, podczas gdy w drugiej - całkowanie ciągłe jest aproksymowane za pomocą zależności przyrostowych. W obu algorytmach model maszyny jest zapisany względem układu współrzędnych związanych ze strumieniem stojana. Zamieszczony jest opis rozważanych modeli oraz wyniki przeprowadzonych symulacyjnych testów.
Źródło:
Present Problems of Power System Control; 2011, 1; 75-88
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy conversion in small water plants with variable speed PM generator
Autorzy:
Sobczyk, T. J.
Mazgaj, W.
Szular, Z.
Węgiel, T.
Powiązania:
https://bibliotekanauki.pl/articles/140885.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnes trwały
prądnica
prostownik PWM
mała energetyka wodna
energetyka wodna
permanent magnet generator
PWM rectifier
small hydro power
Opis:
The Small Hydro Power Plants allow to increase the energy amount from renewable sources, especially from small rivers in mountainous areas. This paper presents a new concept of a energy conversion system for application in a Small Hydropower Plant (SHP) which is based on a permanent magnet generator (PM generator) with a propeller turbine integrated with the generator rotor. The PM generator can work at a variable speed and therefore energy produced by the PM generator has to be converted by means of a power electronic unit to fit to the three-phase power grid parameters. For this concept, dimensions and parameters of the PM generator were specially designed on account of integration with water turbine. The paper precisely describes elements of energy conversion system and also presents the results of numerical tests for chosen working conditions. An original algorithm of control strategy for power electronic unit was used to adjust generated energy to the required parameters of the three-phase grid.
Źródło:
Archives of Electrical Engineering; 2011, 60, 2; 159-168
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koordynacja układów regulacji generatorów i transformatorów elektrociepłowni przemysłowej
Autorzy:
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397382.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
układ regulacji
generator
transformator
elektrociepłownia przemysłowa
control system
transformer
thermal power station
Opis:
Generatory elektrociepłowni przemysłowych (zwykle w liczbie kilku) pracują równolegle, przyłączone do szyn zbiorczych 6 kV. Szyny zbiorcze 6 kV są połączone ze stacją 110 kV za pomocą co najmniej dwóch (zwykle kilku) transformatorów 110/6 kV. Układy regulacji generatorów są często nietrafnie nastawiane, a algorytmy działania regulatorów transformatorów 110/6 kV są nieprawidłowe, uniemożliwiając współpracę układów regulacji elektrociepłowni. W artykule podano propozycję koordynacji algorytmów działania układów regulacji.
Źródło:
Acta Energetica; 2011, 1; 51-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Phase-locked loop technique system with orthogonal signal generator for power electronics controllers
Wykorzystanie układu pętli synchronizacji fazowej z zastosowaniem generatora sygnałów ortogonalnych w energoelektronicznych układach sterowania
Autorzy:
Wyszomirski, M.
Rosołowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/410547.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phase-locked loop
Orthogonal Signal Generator
frequency estimation
phase-angle detection
power electronics controller
Opis:
This paper presents a Phase-Locked Loop (PLL) scheme with Orthogonal Signal Generator (OSG). The proposed technique enables to eliminate the influence of distortions from the observed signal on proper determination of its parameters as a phase, magnitude or frequency. A simulation model of the system is developed and results of investigation are provided. Some recommendations on the scheme settings for elimination of harmonic and inter-harmonic components are also included. It was verified that the proposed PLL with OSG system can be considered as an useful and effective tool in implementations that require a great accuracy of the phase angle and frequency estimation. The system could be applied in three-phase power systems control units such as FACTS converters or doubly-fed induction generators control scheme. Simulation results demonstrate the effectiveness and robustness of the proposed solution.
W artykule przedstawiono układ pętli synchronizacji fazowej (PSF) z generatorem sygnałów ortogonalnych (GSO). Proponowana technika umożliwia wyeliminowanie wpływu zakłóceń zanalizowanego sygnału na określenie jego parametrów takich jak faza, amplituda czy częstotliwość. Przedstawiono model symulacyjny proponowanego układu i zaprezentowano wyniki doświadczeń. Zawarto także niektóre z zalecanych konfiguracji schematu w celu eliminacji składowych harmonicznych i interharmonicznych sygnału. Dowiedziono, że proponowany system PSF z GSO może być rozpatrywany jako użyteczne i efektywne narzędzie w implementacjach wymagających dużej dokładności estymacji fazy i częstotliwości. Proponowany system może być stosowany w układach sterowania trójfazowych systemów takich jak FACTS lub w układach sterowania generatorów indukcyjnych dwustronnie zasilanych (DFIG). Wyniki symulacji wskazują na skuteczność i poprawność działania zaproponowanego rozwiązania.
Źródło:
Present Problems of Power System Control; 2011, 1; 61-74
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Communication issues in the control system of reactive power compensator for hydroelectric plant with induction generator
Autorzy:
Olesiński, R.
Hańczur, P.
Wiśniewski, J.
Koczara, W.
Powiązania:
https://bibliotekanauki.pl/articles/141283.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
generator indukcyjny
kompensacja mocy biernej
PLC
SCADA
induction generator
reactive power compensation
communication technology
Opis:
The presented paper concerns the issues of communication networks applied to monitoring and control of reactive power compensator for small hydroelectric plants installed in areas distant from urban agglomerations. Ethernet, CAN, Modbus and GPRS transmission protocols has been used. Industrial programmable controller as a data collector has been used also.
Źródło:
Archives of Electrical Engineering; 2012, 61, 3; 411-420
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial assumption to the mathematical model of the marine elektromagnetic system with the shaft-generator
Założenia wstępne do opisu modelu matematycznego okrętowego systemu elektroenergetycznego z prądnicą wałową
Autorzy:
Nienartowicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/359554.pdf
Data publikacji:
2012
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
siłownia okrętowa
elektrownia okrętowa
dynamika
model matematyczny
system elektroenergetyczny
prądnica wałowa
power plant
electric power station
dynamics
mathematical model
electromagnetic system
shaft generator
Opis:
The electromagnetic systems with the shaft-generator are being widely used in marine engineering, nowadays. Simulating investigations of transitory electromagnetic processes in such system require complex mathematical model studies to describe properly the dynamics of the containing objects. The following article is the first part of the final description of the mathematical model of marine electromagnetic system with the shaft-generator. It contains both the discussion about external factors affecting the electromagnetic processes in such system and initial assumptions that should be met by the proposed mathematical model.
Współczesna technika okrętowa szeroko stosuje systemy elektroenergetyczne z prądnicą wałową. Badania symulacyjne procesów przejściowych elektromagnetycznych w takim systemie wymagają opracowania kompleksowego modelu matematycznego, opisującego dynamikę obiektów w nim zawartych. Poniższy artykuł jest pierwszą częścią docelowego, końcowego opisu matematycznego modelu okrętowego systemu elektro-energetycznego z prądnicą wałową. Omawia się w nim uwarunkowania zewnętrzne, wpływające na przebieg procesów elektromagnetycznych w systemie oraz podaje się przyjęte założenia wyjściowe, które powinny być spełnione przez proponowany model matematyczny.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2012, 29 (101); 146-150
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Minimization of active power losses in a power transmission system - selected aspects of the computation problem scope
Autorzy:
Wancerz, M
Kacejko, P.
Powiązania:
https://bibliotekanauki.pl/articles/97427.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power transmission system
generator
transformation ratio
Opis:
The paper presents fundamental problems concerning optimization of reactive power flow at simultaneous minimization of active power losses performed in order to enhance voltage conditions in a power system. Calculations have been done in order to show that adequate control of reactive power production in generators as well as proper transformation ratio control of system transformers can contribute to the reduction of active power losses in the system and ensure adequate voltage conditions in all system nodes.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 254-263
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies