Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power flow" wg kryterium: Temat


Tytuł:
Physical properties of triticale starch. Part III. Determination of flow curves of triticale starch pastes
Właściwości fizyczne skrobi pszenżyta. III. Wyznaczanie krzywych płynięcia kleików skrobi pszenżyta
Autorzy:
Gambus, H.
Fortuna, T.
Nowonta, A.
Palasiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1398900.pdf
Data publikacji:
1987
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
triticale starch
flow curves
"n" and "K" constants of the Oswald-de Waele power equation
Opis:
Flow curves of pastes from 53 Polish triticale breeding lines were investigated. Rheological parameters of those pastes, viz. constants "n" and "K" of the power equation, were determined. Seven starches can be distinguished among all the samples, their pastes possessing properties of the Newtonian liquid.
W celu określenia właściwości reologicznych kleików skrobiowych pszenżyta wyznaczono ich krzywe płynięcia. Przebadano w ten sposób skrobie z 53 polskich rodów pszenżyta. Z krzywych płynięcia wyliczono stałe „n" i „K" modelu potęgowego Ostwalda i de Waele (tabela). Dla większości skrobi pszenżyta stała „n" mieściła się w zakresie 0,44-0,68. Natomiast skrobie siedmiu rodów (nr 22, 24, 29, 30, 33, 43, 44) nie wykazywały zdolności tworzenia lepkości strukturalnej, lecz odznaczały się właściwościami płynu newtonowskiego (stała „n" od 0,90-1,10). Przypuszcza się, że spowodowane to było uwarunkowaniami genetycznymi lub podwyższoną aktywnością enzymów amylolitycznych w ziarnie [1, 5]. Kleiki, które miały stałą „n" zbliżoną do jedności charakteryzowały się najniższą stałą „K": od 33-181 mPa·sn, natomiast powstałe znacznie wyższymi wartościami tej stałej (od 1127 do 7966 mPa·sn). Z wyjątkiem wymienionych siedmiu rodów krzywe płynięcia pozostałych kleików były typowe dla płynów nienewtonowskich rozrzedzanych ścinaniem (rys. 1). Zaobserwowano niewielką zależność pomiędzy stałymi modelu potęgowego „n" i „K"; r = -0,31 przy poziomie istotności α= 0.05.
Źródło:
Acta Alimentaria Polonica; 1987, 13, 2; 107-114
0137-1495
Pojawia się w:
Acta Alimentaria Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetyczne charakterystyki degradacji przyczepy
Energetistic characteristics of trailers degradation
Autorzy:
Kaźmierczak, H.
Kromulski, J.
Pawłowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/329112.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
degradacja
trwałość
stanowisko
moc
rozpływ energii
przyczepa
degradation
durability
station
power
energy flow
trailer
Opis:
Przedstawiono ideę energetycznej metody analizy procesu degradacji węzłów zawieszenia przyczepy, poddawanej wymuszeniom kinematycznym na stanowisku badań przyśpieszonych.
There is presented an idea of energetistic method of suspension node degradation process of trailer subjected to kinematic forcing on the station for accelerated tests.
Źródło:
Diagnostyka; 2005, 33; 89-94
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Investigations of the Upqc Arrangement
Autorzy:
Benysek, G.
Powiązania:
https://bibliotekanauki.pl/articles/262602.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
power flow control
harmonics compensation
reactive power compensation
Opis:
This paper presents the fundamental properties and dependences describing the UPQC (Unified Power Quality Conditioner) arrangements. The UPQC devices simultaneously permit to fulfill the following functions: voltage and current harmonics compensation, network voltage and load current symmetrization as well as network voltage stabilization and power flow control. The selected results of the experimental investigations conducted on the small power laboratory model have been described. Applied method for DC link capacity selection was talked over in details and confirmed with experimental results. Results of experimental investigations, including operation of the UPQC arrangement in case of thyristor rectifier load were also introduced.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 27-34
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of the wind generation integration related power quality issues by energy storage
Autorzy:
Kook, K. S.
Liu, Y.
Atcitty, S.
Powiązania:
https://bibliotekanauki.pl/articles/262823.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
wind turbine generator (WTG)
wind farm
Power Quality Energy storage system (ESS)
power flow fluctuation
PSS/E
power system stability
Opis:
The wind power which has been expected to be a promising alternative energy source can bring new challenges when it is connected to the power grid due to the fluctuation nature of the wind and the comparatively new types of its generators. This paper illustrates a possible solution to mitigate these integration issues of the wind power by application of the energy storage to the wind farm in power systems focusing on its short-duration perspective. The simulation model for the Energy Storage System (ESS) connected to the wind farm is implemented using the Power System Simulator for Engineering(PSS/E) which is one of the most widely used program for the power system analysis in US. Employing a sample power system, the control effect of the ESS for mitigating the wind generation related power quality issues by suppressing the power flow fluctuation of the wind farm, and improving power system stability is validated. The counteracting effect of the ESS in the wind farm to the disturbance on the grid is also shown.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 77-82
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komputerowe metody analizy rozpływów mocy w układach elektroenergetycznych
Computer methods of the analysis of load flow in electric power systems
Autorzy:
Brożek, J.
Jedynak, P.
Powiązania:
https://bibliotekanauki.pl/articles/267974.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rozpływy mocy
systemy elektroenergetyczne
sieci rozdzielcze
rozproszone źródła mocy
load flow
power systems
distribution network
dispersed generation
Opis:
W artykule przedstawia się zastosowanie dedykowanych programów komputerowych do obliczeń rozpływów mocy w systemach elektroenergetycznych. Ze względu na rozmiar zadania oraz nieliniowość równań opisujących zależności na moce węzłowe, do rozwiązania rozpływów mocy wykorzystuje się iteracyjne metody rozwiązywania układów równań nieliniowych. Wynikiem analizy jest wektor napięć węzłowych umożliwiający obliczenie parametrów analizowanej sieci. Lokalizowanie w elektroenergetycznej sieci rozdzielczej rozproszonych źródeł mocy powoduje konieczność obliczeń rozpływów mocy również w tej sieci. W pracy przedstawia się wyniki obliczeń rozpływów mocy fragmentu systemu elektroenergetycznego oraz sieci rozdzielczej, w której zainstalowano rozproszone źródło mocy. Przeprowadzone badania wykazały przydatność dedykowanych programów komputerowych do analizy rozpływów mocy.
In the paper the application of dedicated computer programs for the calculation of the load flow in electric power systems is presented. Due to the size of the task as well as non-linearity of the equations describing the dependences of the nod-powers, the load flows are calculated with the use of an iteration-method of solving non-linear equations. The result o the calculations is a vector of no-loads enabling the computation of the parameters of the analyzed system. The installation of dispersed power sources in electric power distribution networks causes the necessity of calculating load flows also in i networks. The paper contains some results of computations of the load flows for a fragment of a power electric system and a distribution network in which there is installed a dispersed power source. The analyses show the usefulness of the dedicated computer programs for analyzing the load flow.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 25; 21-24
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ degradacji urządzeń pomiarowych na pozyskiwanie symptomów niesprawnej pracy złożonych obiektów energetycznych
Influence of measuring equipment degradation on gaining of symptoms of large power units inefficient operation
Autorzy:
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/327488.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
symulacja neuronowa
diagnostyka cieplno-przepływowa
turbina parowa
neural simulation
thermal diagnostics
flow diagnostics
steam power plants
measuring system
Opis:
Opisywana jest możliwość budowania relacji cieplno-przepływowych diagnostycznych z zastosowaniem metody sztucznych sieci neuronowych. Są one zastosowane do detekcji zdegradowanych urządzeń pomiarowych w złożonych systemach pomiarowych. Przedstawiono to na przykładzie bloku energetycznego dużej mocy. Wykorzystano obliczenia symulacyjne degradacji. Rozważano zarówno degradacje samego systemu pomiarowego jak i degradacje geometrii urządzeń składowych. Pokazano dobrą jakość określania symptomów degradacji. Wykorzystano przykłady z praktyki eksploatacyjnej.
Possibility of building of diagnostic relations with usage of artificial neural networks ANN is described in the paper. The relations are applied for detection of the degraded measuring devices in steam power cycles of complex electricity generation systems. The example of the large steam turbine power plant is shown in the paper. Neuronal diagnostic relations are created on the basis of simulation calculations. There are taking into account both degradations of that of measuring equipment as well as simultaneously occurring degradations of measuring equipment and components of thermal cycle. Good quality of neuronal calculations is stated. Application of these relations is shown on some examples from exploitation practice.
Źródło:
Diagnostyka; 2008, 2(46); 67-70
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polish aspects in the modern design solutions of steam turbine flow systems
Autorzy:
Gardzilewicz, A.
Obrzut, D.
Szymaniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/259290.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
steam turbine
power cycles
flow systems
efficiency
errosion
Opis:
This paper presents new solutions of turbine stages which have been applied to high-power steam turbine flow systems. The structures, elaborated in Poland, were designed with the use of the authors’ original computational software and verified by measurements performed on real turbine sets.
Źródło:
Polish Maritime Research; 2009, S 1; 14-21
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of dynamic properties of hydraulic lines for fluid power transmission
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247615.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
delivery of a pump
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
This paper presents the results of a hydraulic line dynamic properties analysis taking into account inertia of the fluid flowing in rigid and flexible lines, the compressibility effect for this fluid and the viscous friction effect. The following are described and analyzed: solution of the wave equation in the form binding four variables: pressure and flow rate at the line input, and pressure and flow rate and the line output; two of the above-mentioned variables should be regarded as independent (input) and the other two as dependent (output), the accuracy comparison of distributed parameters model to lumped parameters model with regard to applicability range in hydraulic systems analysis, pressure value at given installation points as a response to rapid valve closing (transient response) or to valve opening (waterhammer effect). In these considerations the hydraulic line is regarded as a two-port with two inputs and two outputs with a definite transmittance matrix. Main considerations concern the variable resistance model. A general solution is given as a function of the Laplace operator. Introducing appropriate simplifications into the variable resistance model, the constant resistance model and lossless line model is obtained. Also, general solutions for three different lump parameter models are presented. For the lumped parameters lin presents three equivalent models possible, i.e. as: a symmetrical two-port, a two-port with shared resistance and a two-port with capacitance at the output.
Źródło:
Journal of KONES; 2010, 17, 3; 467-475
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of a power transmission system under uncertain load conditions and network configurations
Autorzy:
Zio, E.
Piccinelli, R.
Delfanti, M.
Olivieri, V.
Pozzi, M.
Powiązania:
https://bibliotekanauki.pl/articles/2069672.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
vulnerability
electric power transmission network
load flow
power flow betweenness centrality
uncertainty
Opis:
In this paper, the load flow problem in a power transmission network is studied in presence of load and Power generation uncertainties and transmission lines failures. Network performance indicators are computed and the importance of the different components is evaluated by a power flow betwenness centrality measure.
Źródło:
Journal of Polish Safety and Reliability Association; 2010, 1, 1; 279--284
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przekształcenia warunków hydrologicznych w dolinie Dolnej Wdy wskutek budowy stopni wodnych
The transformation of hydrological conditions in the lower part of the Wda valley as a result of the building barrages
Autorzy:
Szumińska, Danuta
Powiązania:
https://bibliotekanauki.pl/articles/87515.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Geograficzne
Tematy:
dolina Wdy
stopień wodny
zbiornik zaporowy
elektrownia wodna
przepływ
antropopresja
the Wda river valley
barrage
storage reservoir
water power station
flow
anthropogenic change
Opis:
W pracy omówiono zmiany warunków wodnych spowodowane budową stopni piętrzących w dolnym biegu Wdy. Najsilniejsze przekształcenia związane są z funkcjonowaniem kaskady hydroenergetycznej Żur-Gródek. Jej obecność spowodowała znaczne zwiększenie powierzchni zbiorników wodnych oraz przekształcenie reżimu Wdy poniżej kaskady. Na odcinkach zbiornikowych, a w szczególności w Zbiorniku Żur ma miejsce akumulacja materiału wnoszonego przez Wdę i jej dopływy. Wskutek wykorzystania hydroenergetycznego, poniżej kaskady wzrosła nieregularność przepływów, co powoduje zmiany warunków życia biologicznego w korycie. Znaczne i częste wahania przepływów są też przyczyną uruchamiania rumowiska, które akumulowane jest w kolejnym zbiorniku - Kozłowo i na odcinku Wdy powyżej tego zbiornika. Pomimo pewnych negatywnych aspektów zbiorniki zaporowe, w połączeniu z otaczającymi lasami, stanowią atrakcyjny element krajobrazu doliny Wdy i główną atrakcję Wdeckiego Parku Krajobrazowego.
The paper presents the changes of water conditions in the lower part of the Wda river, caused by the construction of barrages. The strongest transformation are connected with the use of the water power stations Żur and Gródek. This two barrages caused considerable enlargement of the water areas and changed regime of the Wda river downstream the Gródek dam. The bed load from the Wda river and their tributaries has been accumulating in the reservoirs, especially in the Żur reservoir. The outflow irregularity increased in the part of the Wda river downstream of the cascade, as the effect of using water for power stations. Large and frequent changes in the volume of the flow cause decrease of the number of species and the size of populations in the Wda river. Despite of some negative aspects reservoirs and their surrounding there are the most attractive element of the Wda valley landscape and the main attraction of the Wda Landscape Park.
Źródło:
Prace Komisji Krajobrazu Kulturowego; 2010, 13; 110-121
1896-1460
2391-5293
Pojawia się w:
Prace Komisji Krajobrazu Kulturowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sound Radiation from a Roundabout
Autorzy:
Piddubniak, O.
Piddubniak, N.
Powiązania:
https://bibliotekanauki.pl/articles/177962.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
roundabout
car sound radiation
stationary phase method
acoustic pressure
power flow density
Opis:
Sound propagation from the vehicles moving on the city roundabout, with taking into account the wind is investigated. Solution of the problem for one moving sound source is found by means of the integral Fourier transforms extended over space variables and time. Inverse transforms are calculated approximately, using a stationary phase method and iterative technique. The solution for a general problem is obtained as a superposition of many partial solutions. The numerical analysis of noise characteristics is performed for the three-way Korfanty roundabout case in Łódz.
Źródło:
Archives of Acoustics; 2010, 35, 3; 437-456
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on blending characteristics of axial flow impellers
Autorzy:
Fort, I.
Jirout, T.
Powiązania:
https://bibliotekanauki.pl/articles/185615.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wirnik osiowy
wirnik tarczowy
przepływ burzliwy
axial flow impeller
pitched-blade impeller
turbulent flow
impeller power input
blending time
Opis:
This paper presents an analysis of the blending characteristics of axial flow high-speed impellers under a turbulent regime of flow of an agitated low viscosity liquid. The conductivity method is used to determine the time course of blending (homogenisation) of miscible liquids in a pilot plant fully baffled mixing vessel, and a torquemeter is used for measuring the impeller power input in the same system. Four-blade and six-blade pitched blade impellers and three high efficiency axial flow impellers are tested for the given degree of homogeneity (98%). The experimental results and also the results of the authors' previous study, in accordance with the theoretical approach described in the literature, show that there is a universal relationship between the impeller power number and the dimensionless blending time, taking into consideration the impeller-to-vessel diameter ratio, independent of the geometry of the axial flow impeller but dependent on the degree of homogeneity. This relationship is found to be valid on a pilot plant scale under a turbulent flow regime of an agitated liquid.
Źródło:
Chemical and Process Engineering; 2011, 32, 4; 311-319
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of dynamic properties attributable to hydraulic lines onto operation of avionic
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247057.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
The present paper is dedicated to discuss how dynamic parameters of a hydraulic line intended to transfer hydraulic power from a source of hydraulic power (a hydraulic pump) to an actuating device (a hydraulic motor) can affect operation of an avionic hydraulic drive. Avionic hydraulic drives are operated with fast-varying waveforms of flow intensities and pressures. It is why analysis of most hydraulic drive systems must take account of compressibility of working fluid and elasticity of hydraulic lines. It leads to a wave model for propagation of energy variation down a hydraulic line (a pipe). The paper deals with flow of a compressible liquid via a hydraulic line with flexible walls. Theoretical deliberations were successfully verified by experimental research studies that were carried out on a dedicated test bench, therefore the presented amplitude vs. frequency characteristic curves of the hydraulic line could be obtained from both theoretical considerations and experimental research studied. The experimental research studies were carried out for hydraulic line terminated with a fixed flow restrictor alone and a flow restrictor combined with a hydraulic accumulator as well as for a hydraulic line supplied from a source of constant pressure and terminated with a valve with adjustable flow together with a hydraulic accumulator. The theoretical calculations for the amplitude vs. frequency characteristic curve are based on a model for a hydraulic line with its resistance depending on frequency.
Źródło:
Journal of KONES; 2011, 18, 4; 535-542
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvisation process for banks capacitor compensation applied fuzzy logic knowledge for nodal detection on electrical network
Autorzy:
Gasbaoui, B.
Oudda, M.
Nasri, A.
Powiązania:
https://bibliotekanauki.pl/articles/384634.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
capacitor placement
fuzzy logic
Harmony Search Optimization (HSO)
capacitor seizing
power flow
Opis:
The main problem of electrical distribution systems is the reactive power flow. It causes reduction of active power transmission, diminishes power losses, and augments the drop voltage. In this research we described an efficiency approach FLC-HSO to solve the optimal power flow (OPF) combinatorial problem. The proposed approach employ tow algorithms, Fuzzy logic controller (FLC) algorithm for nodal detection and harmony search optimization (HSO) algorithm for optimal seizing capacitor of OPF combinatorial problem control variables. HSO method is more proficient in improving combinatory problem. The proposed approach has been examined and tested on the standard IEEE 57-bus test system with different objectives that reflect cost function minimization, voltage profile improvement, and voltage stability enhancement. The proposed approach results have been compared to those that reported in the literature recently. The results are promising and show the effectiveness and robustness of the proposed approach.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2011, 5, 4; 11-16
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of commutation conditions on steady states in matrix converter
Autorzy:
Borkowski, D.
Sobczyk, T. J.
Powiązania:
https://bibliotekanauki.pl/articles/141341.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik macierzowy
regulacja przepływu mocy
metoda bilansu harmonicznych
matrix converter
power flow control
harmonic balance method
Opis:
The paper investigates a significant influence of transients on steady states in a matrix converter with the one-periodic control strategy. Proposed controller can be used as an interconnection device within a power system for a power flow control. However, the presence of inductances in external systems has the significant influence on steady state of a matrix converter operation. The special current injection method has been developed to ensure a proper operation of a matrix converter. Presented analysis of steady states is carried out in a frequency domain using the harmonic balance method. Obtained numerical results, which are confirmed by a time domain analysis, prove the effectiveness of the proposed method.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 77-83
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies