Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power curve" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Experimental and Theoretical Study on a Wind Energy Unit
Autorzy:
Abusamaha, Hanan M.
Dawoud, Farah
Al-Qalab, B.
Ayadi, O.
Powiązania:
https://bibliotekanauki.pl/articles/123619.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wind turbine
angle of attack
power curve
Opis:
The conversion process in the wind turbine, from mechanical (kinetic) energy to electrical energy, is affected by many factors that increase or decrease the useful output of the wind energy convertor. In this paper, three factors were studied experimentally on a Horizontal Axis Wind Energy Unit “EEEC” in laboratory-scale. The aim of this experiment was to study the influence of the number of blades, the angle of attack and the incident angle on the wind energy unit parameters to optimize its efficiency. For this purpose, the effect of the number of blades was studied firstly, in order to select the number of blades where the maximum inputs obtained at lab ambient temperature 25 °C and atmospheric pressure. Then, different readings of the incident angle and angle of attacks were taken. The data was analyzed using Microsoft Excel software. The results show that the maximum parameters of wind unite energy that produce the maximum efficiency, namely: voltage (volt), current (ampere) and rotational speed (rpm) are obtained when the number of blades is 4, the incident angle is 0° (when the rotor direction is with wind direction) and the angle of attack is 75°. Finally, these results were implemented in a simulation program (HOMER software) that uses this turbine in a resident along with storage to cover the needs of a selected house.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 207-214
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Partial Shading Detection in Solar System Using Single Short Pulse of Load
Autorzy:
Bartczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/221207.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
maximum power point
partial shading
load pulse
test station
I-V curve
Opis:
A single photovoltaic panel under uniform illumination has only one global maximum power point, but the same panel in irregularly illuminated conditions can have more maxima on its power-voltage curve. The irregularly illuminated conditions in most cases are results of partial shading. In the work a single short pulse of load is used to extract information about partial shading. This information can be useful and can help to make some improvements in existing MPPT algorithms. In the paper the intrinsic capacitance of a photovoltaic system is used to retrieve occurrence of partial shading.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 193-199
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza właściwości reologicznych kompozytów polietylenu z węglanem wapnia wyznaczonych podczas przepływu przez dyszę płaską oraz cylindryczną o takiej samej wartości promienia hydraulicznego - pomiary typu in-line
Analysis of rheological properties of polyethylene composites with calcium carbonate determined during flow through a flat and a cylindrical die with the same hydraulic radius value - in-line measurements
Autorzy:
Kloziński, A.
Powiązania:
https://bibliotekanauki.pl/articles/946260.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Inżynierii Materiałów Polimerowych i Barwników
Tematy:
polietylen
węglan wapnia
reologia in-line
promień hydrauliczny
MVR
wykładnik płynięcia
krzywa lepkości
polyethylene
calcium carbonate
in-line rheology
hydraulic radius
power low index
viscosity curve
Opis:
W artykule przedstawiono wyniki badań reologicznych polietylenu małej gęstości (PE-LD) oraz jego kompozytów z węglanem wapnia, zawierających 7, 14, 21 i 28 % mas. napełniacza. Kompozyty polimerowe wytworzone zostały w procesie wytłaczania dwuślimakowego. Pomiary właściwości reologicznych przeprowadzono w warunkach procesu wytłaczania, przy użyciu reometru typu in-line z płaską (L = 20, W = 2 mm, H = 2 mm) oraz cylindryczną (L = 20 mm, R = 1,8 mm) głowicą pomiarową. Porównano właściwości reologiczne materiałów polimerowych podczas przepływu przez dysze o różnej geometrii (dysza cylindryczna i płaska), ale takiej samej wartości promienia hydraulicznego (Rh = 0,9) i długości. Ocena właściwości reologicznych kompozytów została przeprowadzona w oparciu o model potęgowy Ostwalda-de Waele’a. Określono wpływ dodatku CaCO3 na charakterystykę pracy wytłaczarki, przebiegi krzywych płynięcia, przebiegi krzywych lepkości oraz objętościowego wskaźnika szybkości płynięcia (MVR).
The article has reported the results of rheological testing of low-density polyethylene (LDPE) and its calcium carbonate composites containing 7, 14, 21 and 28 wt % filler, respectively. The polymer composites were produced in a twin-screw extrusion process. The measurements of the rheological properties of the polymeric materials ware made under extrusion process conditions, using an in-line rheometer with a slit (L = 20, W = 2 mm, H = 2 mm) and s cylindrical (L = 20 mm, R = 1,8 mm) extrusion die. The rheological properties of polymer materials were compared during the flow through dies with different geometry (cylindrical and slit die), but the same value of the hydraulic radius (Rh = 0.9) and length. The rheological parameters were determined based on the Ostwald-de-Waele power-law model. The effect of the addition of CaCO3 on the characteristic of extruder operation; the flow curves; the viscosity curves, and volume-flow rate (MVR) have been determined.
Źródło:
Przetwórstwo Tworzyw; 2018, T. 24, Nr 6 (186), 6 (186); 11-21
1429-0472
Pojawia się w:
Przetwórstwo Tworzyw
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interakcje pomiędzy układami przesyłowymi prądu stałego w warunkach obniżonej mocy zwarciowej
Interaction between HVDC links in low short circuit power conditions
Autorzy:
Kosmecki, M.
Madajewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/266337.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
HVDC
stabilność napięciowa
interakcje
przewroty komutacyjne
Maximum Power Curve
multi-infeed system
interaction
Opis:
Analiza wybranych zagadnień równoległej pracy dwóch układów przesyłowych prądu stałego (HVDC) o odmiennych technologiach, tj. układu tyrystorowego (LCC – Line Commutated Converter) i tranzystorowego (VSC – Voltage Source Converter) jest przedmiotem niniejszego referatu. Pokazano, że równoległa praca układów jest możliwa w warunkach niskiej mocy zwarciowej tam, gdzie sam układ LCC o równoważnej mocy nie mógłby pracować stabilnie w trybie regulacji mocy. Warunkiem jest praca falownika łącza VSC HVDC w trybie regulacji napięcia AC. Z drugiej strony w określonych okolicznościach to właśnie ten tryb może być przyczyną pogorszenia warunków pracy układu LCC, co wskazuje na potrzebę dokładnej analizy takich przypadków celem właściwego doboru nastaw odpowiednich układów regulacji.
This paper describes the results of an analysis of selected problems in the parallel operation of two HVDC systems based on different technologies, namely Line Commutated Converter (LCC HVDC) and Voltage Source Converter (VSC HVDC). Using Maximum Power Curves (MPC) technique it is shown that the parallel operation of the two systems in low short circuit power conditions is possible where a single LCC HVDC scheme of equivalent rated power would fail to operate stably in constant power mode. However, the prerequisite for such operation is active AC voltage control offered by the VSC inverter. It is also shown that the positive influence of the VSC converter is noticeable if the two inverters are a considerable distance apart (e.g. 100 or 200 km). On the other hand, EMTP simulations reveal also adverse effects of the mutual influence, particularly apparent in low ESCR systems where the so-called voltage and power instability problem of the AC/DC systems is be more evident. This phenomenon is the basic cause of the undesirable interaction between the LCC HVDC and VSC HVDC resulting in more difficult return to nominal operating conditions after a commutation failure in the LCC system. The proposed and demonstrated solution is to tune down the PLL and voltage controller gains in order to make the overall system less stiff.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 23-26
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of constant parameters of copper as power-law hardening material at different test conditions
Autorzy:
Kowser, M. A.
Mahiuddin, M.
Powiązania:
https://bibliotekanauki.pl/articles/955240.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
power-law hardening constant
work-hardening process
stress hardening exponent
power-law hardening material
heat treatment
tensile test
stress-strain curve
proces utwardzania
obróbka cieplna
próba rozciągania
Opis:
In this paper a technique has been developed to determine constant parameters of copper as a power-law hardening material by tensile test approach. A work-hardening process is used to describe the increase of the stress level necessary to continue plastic deformation. A computer program is used to show the variation of the stress-strain relation for different values of stress hardening exponent, n and power-law hardening constant, α . Due to its close tolerances, excellent corrosion resistance and high material strength, in this analysis copper (Cu) has been selected as the material. As a power-law hardening material, Cu has been used to compute stress hardening exponent, n and power-law hardening constant, α from tensile test experiment without heat treatment and after heat treatment. A wealth of information about mechanical behavior of a material can be determined by conducting a simple tensile test in which a cylindrical specimen of a uniform cross-section is pulled until it ruptures or fractures into separate pieces. The original cross sectional area and gauge length are measured prior to conducting the test and the applied load and gauge deformation are continuously measured throughout the test. Based on the initial geometry of the sample, the engineering stress-strain behavior (stress-strain curve) can be easily generated from which numerous mechanical properties, such as the yield strength and elastic modulus, can be determined. A universal testing machine is utilized to apply the load in a continuously increasing (ramp) manner according to ASTM specifications. Finally, theoretical results are compared with these obtained from experiments where the nature of curves is found similar to each other. It is observed that there is a significant change of the value of n obtained with and without heat treatment it means the value of n should be determined for the heat treated condition of copper material for their applications in engineering fields.
Źródło:
International Journal of Applied Mechanics and Engineering; 2014, 19, 4; 687-698
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and modeling of load parameters of wind power station
Autorzy:
Medykovskyj, M.
Kravchyshyn, V.
Shunevych, O.
Powiązania:
https://bibliotekanauki.pl/articles/410969.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
wind power station (WPS)
load curve
management system
input load parameters simulation
Opis:
The method and the load parameters dynamics simulation algorithm fed to the input of the energy-dynamic wind power station modes management system have been developed. Based on the real data analysis, we obtained dependencies of the management system input data changes for the specific time intervals. Input load parameters were simulated using the developed method. We have obtained data for the neural network training with the justification of changes in active wind power composition. The results are shown in a load parameters table as input management system data and estimated load charts. The results are important for the wind power station management system simulation as they provide higher reliability and accuracy of the results.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2015, 4, 2; 19-24
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hilbert curve fractal antenna for detection and on-line monitoring of partial discharges in power transformers
Antena fraktalna Hilberta do detekcji i monitoringu wyładowań niezupełnych w transformatorach energetycznych
Autorzy:
Sikorski, W.
Szymczak, C.
Siodła, K.
Polak, F.
Powiązania:
https://bibliotekanauki.pl/articles/300766.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
fault diagnosis
maintenance of power transformers
partial discharge detection
monitoring
UHF method
Hilbert curve fractal antenna
diagnostyka uszkodzeń
eksploatacja transformatorów energetycznych
detekcja wyładowań niezupełnych
monitoring wyładowań niezupełnych
metoda UHF
antena fraktalna Hilberta
Opis:
This article describes the design of UHF Hilbert curve fractal antenna (HCFA) specially adapted for the partial discharge monitoring system. The authors present the mathematical apparatus for calculating resonant frequencies of Hilbert fractal antenna and results of a computer simulation of the developed prototype. In the design process, the antenna’s working environment (mineral oil) and the mechanical construction of the transformer inspection window were taken into consideration as well. The article also shows the results of laboratory tests carried out in the transformer tank model with different type of partial discharge sources. Both simulations and partial discharge measurements showed that the HCFA, due to such properties as: multi-resonance, small size, low fabrication cost and high sensitivity, is an interesting alternative to other UHF probes installed in transformer inspection window.
W artykule zaprezentowano projekt anteny fraktalnej Hilberta przeznaczonej do stosowania w systemach monitoringu wyładowań niezupełnych wykorzystujących metodę UHF. Autorzy szczegółowo opisali aparat matematyczny służący do estymacji częstotliwości rezonansowych anteny fraktalnej Hilberta oraz wyniki symulacji komputerowych. Ponadto, w artykule zaprezentowano wyniki pomiarów laboratoryjnych, w trakcie których generowano impulsy wyładowań niezupełnych w modelu kadzi transformatora energetycznego. Zarówno wyniki symulacji komputerowych jak i pomiarów laboratoryjnych wykazały, że prototypowa antena fraktalna Hilberta, dzięki takim własnościom jak: wielorezonansowość, małe wymiary, niski koszt produkcji oraz wysoka czułość, stanowi ciekawą alternatywę dla innych czujników UHF instalowanych w oknie rewizyjnym transformatora energetycznego.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 3; 343-351
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie efektowności turbin wiatrowych dużej mocy
Research studies on the efficiency of wind turbine generators
Autorzy:
Szczyrba, T.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/159046.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
turbiny wiatrowe
elektrownie wiatrowe
sprawność
wydajność
efektywność
wind turbine
efficiency
power curve
wind power plant
generator
Opis:
Podstawowym celem przeprowadzonych badań, było określenie wpływu zmian gęstości powietrza atmosferycznego na wyniki obliczeń wskaźników charakteryzujących efektywność elektrowni wiatrowych. Przy czy założono, że efektywność opisuje wielkość energii elektrycznej wyprodukowanej w określonym przedziale czasowym, przy istniejących warunkach atmosferycznych dla danej lokalizacji i przy uwzględnieniu jakości wyprodukowanej energii oraz rzeczywistej sprawności podzespołów prądotwórczych instalacji wiatrowych i ich układów sterowania. W części opisowej scharakte-ryzowano zastosowane urządzenia pomiarowe, usytuowanie mierników i sposób ich kalibracji oraz podstawowe zalecenia dotyczące metodyki wykonywania pomiarów wartości temperatury, ciśnienia oraz wilgotności powietrza atmosferycznego. Natomiast w części wynikowej przedstawiono wykresy obrazujące wpływ zarejestrowanych parametrów atmosferycznych i obliczonej na ich podstawie gęstości powietrza na przebiegi empirycznej krzywej mocy oraz na wartości rzeczywistej sprawności.
The primary objective of the research studies was to determine the impact of the air density changes on the calculation results of indicators characterizing the efficiency of a wind power plant. The equipment used for measuring purposes, location of metres and their calibration methods were characterized in the descriptive part of the article. Additionally, basic recommendations on the methodology of measuring the ambient air values of temperature, pressure and humidity. Wherein, it was assumed that the efficiency is being described by the electric force generated in a specified period of time, under existing weather conditions for the given location, taking into account the quality of the generated energy and the real efficiency of components of the wind turbine generators and their control systems. In the part of the describing the results, graphs showing the impact of the recorded atmospheric parameters on the courses of empirical power curve and the real efficiency value were presented.
Źródło:
Prace Instytutu Elektrotechniki; 2013, 261; 97-104
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza statystyczna parametrów pracy elektrowni wiatrowej o mocy nominalnej 1,2 MW
Statistical analysis of working parameters of a wind power plant with 1,2 MW nominal power
Autorzy:
Szmechta, M.
Zmarzły, M.
Adamkiewicz, N.
Powiązania:
https://bibliotekanauki.pl/articles/275008.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
elektrownia wiatrowa
SOAP
krzywa mocy
efektywność turbiny wiatrowej
turbina wiatrowa
wind turbine
power curve
efficiency of wind turbine
Opis:
Artykuł przedstawia analizę statystyczną wyników pomiarów podstawowych parametrów pracy turbiny wiatrowej o mocy nominalnej równej 1,2 MW. Dokonano analizy pomiarów prędkości wiatru, prędkości obrotowej generatora oraz chwilowej mocy produkowanej przez turbinę. Poddano analizie wyniki obróbki statystycznej, dokonując próby opisania punktów charakterystycznych układu automatycznego sterowania. Zaproponowano kierunek prac zmierzających do poprawy efektywności układów sterowania turbin.
In this paper the statistical analysis of the primary wind turbine parameters is presented. The measurements were acquired from a wind turbine of 1,2 MW nominal power. In this article wind speed, rotor speed and momentary power production measurements were analysed. The statistical analysis results enable to formulate characteristic points of automatic control system. The research directions of effectiveness improvement of wind turbine control systems were proposed.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 65-68
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical approach to the physics of fuel cells
Autorzy:
Wijewardena Gamalath, K. A. I. L.
Peiris, B. M. P.
Powiązania:
https://bibliotekanauki.pl/articles/411573.pdf
Data publikacji:
2012
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
ogniwa paliwowe
transport jonów
gradient stężenia
straty polaryzacyjne
krzywa polaryzacji
krzywa mocy
fuel cell
ion transport rate
concentration gradient
polarization losses
polarization curve
power curve
Opis:
Ion transport rate of PAFC, AFC, PEMFC, DMFC and SOFC fuel cells under the influence of an electric field and concentration gradient were evaluated for static electrolytes. AFC are the best fuel cells for high er current applications while direct methanol fuel cells DMFC are the best for lower current applications AT lower temperatures. An equation for voltage output of a general fuel cell was obtained in terms of temperature and partial pressure of reactants. Performance of a 2D fuel cell was analyzed by simulating polarization and power curves for a fuel cell operating at 60 ?C with a limiting current density of 1.5 A cm- 2. The maximum power for this fuel cell was 8.454 W delivering 82% of maximum loading current density. When the temperature was increased by one third of its original value, the maximum power increased by 6.75% and at 60 ?C for a 10 times increment of partial pressure of reactants, the maximum power increased by 2.43%.The simulated power curves of the fuel cells were best described by cubic fits.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2012, 2; 15-27
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies