Tytuł:
HVDC auxiliary emergency power control strategy for power disturbance in two different positions of AC/DC interconnection system
Autorzy:
Li, Congshan
He, Ping
Wang, Youyi
Ji, Yuyi
Yang, Cunxiang
Powiązania:
https://bibliotekanauki.pl/articles/141502.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
unbalanced power
emergency control
power angle stability
frequency stability
control logic
Opis:
High voltage direct current (HVDC) emergency control can significantly improve the transient stability of an AC/DC interconnected power grid, and is an important measure to reduce the amount of generator and load shedding when the system fails. For the AC/DC interconnected power grid, according to the location of failure, disturbances can be classified into two categories: 1) interconnected system tie-line faults, which will cause the power unbalance at both ends of the AC system, as a result of the generator rotor acceleration at the sending-end grid and the generator rotor deceleration at the receiving-end grid; 2) AC system internal faults, due to the isolation effect of the DC system, only the rotor of the generator in the disturbed area changes, which has little impact on the other end of the grid. In view of the above two different locations of disturbance, auxiliary power and frequency combination control as well as a switch strategy, are proposed in this paper. A four-machine two-area transmission system and a multi-machine AC/DC parallel transmission system were built on the PSCAD platform. The simulation results verify the effectiveness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 245-263
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power System Transient Stability Case Study: A Power Sub-Station Plant in Sudan
Autorzy:
Abbas, Asma
Kamal, Ramadan Doud
Elmustafa, Sayed Ali Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1193487.pdf
Data publikacji:
2021
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Dynamic Stability
GARRI power stations
Swing Equation
Transient Stability
power angle
synchronism
Opis:
Power system stability is defined by the tendency of the energy system to develop recovery forces equal or greater than the disturbing forces to maintain a stable equilibrium state. In general, power system stability problems are usually divided into two parts, steady state and transient state. An extension of steady-state stability is dynamic stability. Transient stability deals with the effects of large disturbances such as malfunctions, sudden line interruptions, and sudden application or load removal. This research is presents load angle method to transient stability problem for multi-machine system. The ETAP program is used to simulate the above method to study transient stability. A sub-station plant in Khartoum (GARRI) with four generation sections (1, 2 and 4) has been taken as a case study. The simulation result shows that when a single line-ground fault occurs at main busbar and cleared at time t = 0.4 sec the system is stable, in case 2, when the same fault cleared at t = 3 sec the system become unstable.
Źródło:
World Scientific News; 2021, 158; 267-284
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
A computer simulation of the phase shifter effects in the power system with wye connection of the series transformer
Autorzy:
Sarnicki, M.
Tarakan, B.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/268014.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej i biernej
regulacja kąta mocy
Phase Shifter
active and reactive power flow control
power angle
Opis:
Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
The following article describes the adjustment of the active and reactive power using the phase shifter. The winding of the booster transformer (series) is wye connected. The article shows the regulation of the active and reactive power for selected power system that is 10 bus system with phase shifter. The phase shifter also regulates flow of the active and reactive power simultaneously in the power system. The most common situation is when the both power regulation are independent and it is a better way to have control of both of them. The simultaneous regulation of the active and reactive power is possible by adding transformed voltage from different phases.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 167-169
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
A comparison transmission capacity of two regulation transformers with quadrature regulation and in-phase regulation
Autorzy:
Sarnicki, M.
Zajczyk, R.
Tarakan, B.
Tarakan, K.
Powiązania:
https://bibliotekanauki.pl/articles/267801.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
regulacja przepływu mocy biernej
regulacja kąta mocy
transformator dodawczy
Phase Shifter
active power flow control
reactive power flow control
power angle
booster transformer connections
Opis:
Poniższy artykuł przedstawia możliwość regulacji mocy czynnej i biernej przepływającej pomiędzy podsystemami elektroenergetycznymi. Do regulacji przepływów wykorzystano przesuwnik fazowy i transformator dodający napięcie w fazie. Zilustrowana została regulacja mocy czynnej i biernej w badanym systemie elektroenergetycznym. Istotna jest zależność regulacji danej mocy od układu połączeń strony SN transformatora dodawczego (czy układ działa, jako przesuwnik czy jako transformator dodający napięcie w fazie).
This paper describes the regulation of active and reactive power between the subsystems in larger power system. To regulate the flow were used phase shifters and booster transformer which adds voltages in phase. The regulation of the active power and reactive in considered power system was shown in this article. Important is the way to regulate a certain kind of power (active or reactive), which strongly depends of MV side connections of booster transformer (whether the system acts as a phase shifter or as a transformer which adds the voltage in phase).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 89-91
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and Theoretical Study on a Wind Energy Unit
Autorzy:
Abusamaha, Hanan M.
Dawoud, Farah
Al-Qalab, B.
Ayadi, O.
Powiązania:
https://bibliotekanauki.pl/articles/123619.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wind turbine
angle of attack
power curve
Opis:
The conversion process in the wind turbine, from mechanical (kinetic) energy to electrical energy, is affected by many factors that increase or decrease the useful output of the wind energy convertor. In this paper, three factors were studied experimentally on a Horizontal Axis Wind Energy Unit “EEEC” in laboratory-scale. The aim of this experiment was to study the influence of the number of blades, the angle of attack and the incident angle on the wind energy unit parameters to optimize its efficiency. For this purpose, the effect of the number of blades was studied firstly, in order to select the number of blades where the maximum inputs obtained at lab ambient temperature 25 °C and atmospheric pressure. Then, different readings of the incident angle and angle of attacks were taken. The data was analyzed using Microsoft Excel software. The results show that the maximum parameters of wind unite energy that produce the maximum efficiency, namely: voltage (volt), current (ampere) and rotational speed (rpm) are obtained when the number of blades is 4, the incident angle is 0° (when the rotor direction is with wind direction) and the angle of attack is 75°. Finally, these results were implemented in a simulation program (HOMER software) that uses this turbine in a resident along with storage to cover the needs of a selected house.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 207-214
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power and thrust coefficients of the horizontal axis tidal stream turbine with different twist angles, blade numbers, and section profiles
Autorzy:
Abbasi, Alireza
Ghassemi, Hassan
Molyneux, David
Powiązania:
https://bibliotekanauki.pl/articles/135026.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
HATST
twist angle
blade profile
blade number
power coefficient
thrust coefficients
Opis:
The purpose of this research was to investigate the power and thrust coefficients of a horizontal axis tidal stream turbine (HATST) with different blade geometries, including twist angles, blade numbers, and section profiles. The RANS equations and Star-CCM+ commercial software were used to numerically analyze these variables. Furthermore, the turbulence model used in this study is a Realisable k-ε turbulent model. Nine different models were defined by changing the twist angle, thickness, camber, and blade numbers. The results are presented, and the power and thrust coefficients are compared against TSR for each of the nine different models. The pressure distribution and flow velocity contour are also presented and discussed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 57 (129); 11-20
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of using various methods for car shock absorbers diagnostic tests
Autorzy:
Guzek, Marek
Zdanowicz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/263600.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
shock absorbers testing
EUSAMA test
phase angle method
half-power bandwidth method
simulation tests
Opis:
The work concerns the diagnostic assessment of the technical condition of the car suspension. The paper discusses practical problems that usually appear during testing of car shock absorbers mounted in a vehicle. The results of experimental tests for passenger car, carried out according to the EUSAMA standard test, were compared with the results obtained using newer methods (phase angle method and half power bandwidth method - HPBM). The article also deals with the issue of incompatibility of typical excitation at diagnostic devices for testing suspension with the one that often occurs in road conditions (by simulation method). The main purpose of the work was to assess the usefulness and reliability of various diagnostic methods intended for the testing of vehicle shock absorbers without disassembly them from the vehicle. The analyses carried out indicated the advantages and disadvantages of these methods in practice. It is also shown that the conditions of diagnostic tests correspond poorly to the operating conditions of the shock absorbers under normal vehicle operating conditions. An important factor in this case is the sliding friction in the suspension.
Źródło:
Archiwum Motoryzacji; 2020, 88, 2; 99-108
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Phase-locked loop technique system with orthogonal signal generator for power electronics controllers
Wykorzystanie układu pętli synchronizacji fazowej z zastosowaniem generatora sygnałów ortogonalnych w energoelektronicznych układach sterowania
Autorzy:
Wyszomirski, M.
Rosołowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/410547.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phase-locked loop
Orthogonal Signal Generator
frequency estimation
phase-angle detection
power electronics controller
Opis:
This paper presents a Phase-Locked Loop (PLL) scheme with Orthogonal Signal Generator (OSG). The proposed technique enables to eliminate the influence of distortions from the observed signal on proper determination of its parameters as a phase, magnitude or frequency. A simulation model of the system is developed and results of investigation are provided. Some recommendations on the scheme settings for elimination of harmonic and inter-harmonic components are also included. It was verified that the proposed PLL with OSG system can be considered as an useful and effective tool in implementations that require a great accuracy of the phase angle and frequency estimation. The system could be applied in three-phase power systems control units such as FACTS converters or doubly-fed induction generators control scheme. Simulation results demonstrate the effectiveness and robustness of the proposed solution.
W artykule przedstawiono układ pętli synchronizacji fazowej (PSF) z generatorem sygnałów ortogonalnych (GSO). Proponowana technika umożliwia wyeliminowanie wpływu zakłóceń zanalizowanego sygnału na określenie jego parametrów takich jak faza, amplituda czy częstotliwość. Przedstawiono model symulacyjny proponowanego układu i zaprezentowano wyniki doświadczeń. Zawarto także niektóre z zalecanych konfiguracji schematu w celu eliminacji składowych harmonicznych i interharmonicznych sygnału. Dowiedziono, że proponowany system PSF z GSO może być rozpatrywany jako użyteczne i efektywne narzędzie w implementacjach wymagających dużej dokładności estymacji fazy i częstotliwości. Proponowany system może być stosowany w układach sterowania trójfazowych systemów takich jak FACTS lub w układach sterowania generatorów indukcyjnych dwustronnie zasilanych (DFIG). Wyniki symulacji wskazują na skuteczność i poprawność działania zaproponowanego rozwiązania.
Źródło:
Present Problems of Power System Control; 2011, 1; 61-74
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie przepływami mocy w systemie elektroenergetycznym z wykorzystaniem transformatorów z regulacją wzdłużno-poprzeczną
The control of power flows in power system using phase-angle voltage control transformers
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266590.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rozpływ mocy
zespół transformatorowy
regulacja wzdłużono-poprzeczna
power flow
transformer unit
phase-angle voltage control
Opis:
Transformatory z regulacją wzdłużno-poprzeczną pozwalają na kształtowanie zarówno poziomu, jak i kąta napięcia. Daje to możliwość regulacji parametrów stanu układu przesyłowego, a w efekcie wpływa na zmianę rozpływu mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
The functioning of the power transmission system is the result of using, among others, devices for the transmission and transformation electricity. Proper operation and control of these devices allows to maintain the correct parameters and continuity of electricity supply to final customers. In the group of devices of electricity transformation it can be distinguished from control transformers that have the ability to shape both the magnitude and the angle of voltage. In this way, it can be adjusted state parameters of power system allow the selection of the size of active and reactive power transmission. This property lets they provide a potential opportunity to influence the power load flow (including active power) in electric power networks. The paper is presented a problem of phase-angle voltage control in power system and model of such a transformer unit. The presented transformer unit model are used for power network calculation, especially to power flows control. It was prepare some power flows cases in high voltage networks. There is presented results of power flow system study with using the voltage angle control of such transformer units.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 73-80
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Voltage-regulating and Phaseshifting Transformers to Control Power Flows in the Power System
Wykorzystanie transformatorów z regulacją skośną do sterowania przepływami mocy w systemie elektroenergetycznym
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/397531.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
rozpływ mocy
zespół transformatorowy
regulacja wzdłużno-poprzeczna
active and reactive power flow
regulating transformer
voltage-magnitude-regulating
phase-angle-regulating
Opis:
Transmission system performance results from, among other factors, the use of devices for electricity transmission and transformation. Proper operation and control of these devices allows maintaining proper electricity parameters and the continuous supply to end consumers. In the group of electricity transforming devices transformers can be distinguished by the ability to control both the magnitude and phase angle of voltage. In this way transmission system state parameters are adjusted, which enable selecting the reactive and active power. On the one hand, these are devices of a complex structure, resulting in difficult operating conditions, while on the other hand they provide a potential opportunity to influence the power flow (including active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.
Funkcjonowanie systemu przesyłowego jest wynikiem wykorzystywania pracy m.in. urządzeń służących do przesyłu, jak i transformacji energii elektrycznej. Prawidłowa eksploatacja i sterowanie tymi urządzeniami pozwala na zachowanie właściwych parametrów energii elektrycznej oraz ciągłości zasilania odbiorców końcowych. W grupie urządzeń pozwalających na transformację energii elektrycznej można wyróżnić transformatory z regulacją, które mają możliwość kształtowania zarówno poziomu, jak i kąta napięcia. W ten sposób regulowane są parametry stanu układów przesyłowych pozwalające na dobór przesyłanych wielkości mocy biernej oraz czynnej. Z jednej strony układy te są urządzeniami o skomplikowanej budowie, co wpływa na utrudnione warunki ich eksploatacji, ale jednocześnie z drugiej strony dają one potencjalnie możliwość wpływu na rozpływy mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego, przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
Źródło:
Acta Energetica; 2015, 4; 87-98
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu jednoczesnej zmiany kąta pochylenia łopatek i wału mieszadła na proces wytwarzania zawiesiny lekkich cząstek
Research into the impact of simultaneous change of stirrer blades and shaft inclination angles on the process of floating particles suspension production
Autorzy:
Olejniczak, K.
Wesołowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2072219.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mieszanie
moc mieszania
pochylenie łopatek i wału
zawiesina lekkich cząstek
mixing, mixing power
blades and shaft inclination angle
floating particles suspension
Opis:
W pracy badano wpływ jednoczesnej zmiany kąta pochylenia łopatek i wału mieszadła na proces wytwarzania zawiesiny lekkich cząstek. Podczas badań dyspergowano granulat polietylenu w wodzie w mieszalniku bez przegród. Stosowano mieszadło turbinowe z sześcioma łopatkami. Wyniki wykreślono w postaci klasycznych charakterystyk mocy mieszania. Stwierdzono występowanie istotnego wpływu kąta pochylenia łopatek i brak wpływu kąta pochylenia wału na przebieg procesu.
Influence of simultaneous change of blades and agitator shaft inclination angle on the floating particles suspension production was studied. During the experimental tests polyethylene granulate was dispersed in water in a mixer without baffles. A turbine agitator with six blades was used in experiments. The results were plotted as classical mixing power characteristics. A significant influence of blades inclination angle and no effect of shaft inclination on the process were found.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 5; 455--456
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja miernika fazy z odniesieniem wyniku pomiaru do państwowego wzorca jednostki miary kąta płaskiego
Calibration of phase meter with relation to the national standard of an angle measurement unit
Autorzy:
Szutkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/268385.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kąt fazowy
współczynnik mocy
prąd AC
moc i energia prądu AC
licznik energii elektrycznej prądu AC
phase angle
power factor
AC current
AC voltage
power energy
AC energy
AC current meter
Opis:
W referacie zaprezentowano metodę do pomiaru wartości kąta przesunięcia fazowego pomiędzy sygnałami prądu i napięcia przemiennego z odniesieniem wyniku pomiaru do państwowego wzorca jednostki miary kąta płaskiego, z wykorzystaniem enkodera inkrementalnego. Opracowana metoda pomiarowa ma zastosowanie do pomiaru wartości kątów przesunięć fazowych pomiędzy sygnałami o znacznej amplitudzie i znacznej różnicy wartości tych amplitud. Spójność pomiarowa pomiaru kątów między sygnałami elektrycznymi jest najczęściej odnoszona do Państwowego wzorca jednostek miar czasu i częstotliwości. W przypadku pomiarów kąta między sygnałami prądu i napięcia w elektroenergetyce zapewnienie spójności pomiarowej do wzorca czasu i częstotliwości jest bardzo kłopotliwe ze względu na duże wartości amplitud mierzonych sygnałów oraz na występujące duże różnice wartości amplitud.
The paper presents a method for measuring the value of the phase angle between current and alternating current signals with reference to the national standard of the angle of flat unit, using an incremental encoder. The developed measurement method is used to measure the values of the phase shift angles between high amplitude signals and a significant difference in the values of these amplitudes. The traceability for the measurement phase of angle between electrical signals is most often referred to the national time and frequency standard. In the case of measuring angles between current and voltage signals in the power supply, it is very troublesome to ensure the consistency of the measurement with the time and frequency standard because of the large amplitude values of the measured signals and differences amplitude.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 217-219
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy pomiarów odkształconych przebiegów prądowych przy zastosowaniu dostępnych na rynku przekładników i przetworników prądowo-napięciowych
Problems of measuring distorted currents using commercially available current transformers and current-voltage transducers
Autorzy:
Wiśniewski, Grzegorz
Macierzyński, Dariusz
Habrych, Marcin
Miedziński, Bogdan
Powiązania:
https://bibliotekanauki.pl/articles/199218.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
urządzenia zasilające górnicze sieci elektroenergetyczne
przetworniki prądowo-napięciowe
przekładniki prądowe
błędy prądowe
błędy kątowe
mining power networks
current-voltage converters
current transformers
current errors
angle errors
Opis:
W artykule przedstawiono porównawcze wyniki badań właściwości metrologicznych wybranych, dostępnych na rynku przekładników i przetworników prądowych. Sformułowano odpowiednie wnioski odnośnie do ich przydatności w układach pomiarowych prądów o stosunkowo małych wartościach (od 1 A do 30 A) ale o częstotliwości zmieniającej się w zakresie od 10 Hz do 550 Hz.
The article presents comparative results of metrological properties of selected current transformers and current -voltage transducers available on the market. Appropriate conclusions were formulated regarding their usefulness in current measuring systems with relatively small values (from 1 A to 30 A) but with a frequency varying from 10 Hz to 550 Hz.
Źródło:
Maszyny Górnicze; 2019, 37, 4; 3-14
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel source side power quality improved soft starting of three-phase induction motor using a symmetrical angle controller through pic microcontroller
Autorzy:
Selvaperumal, S.
Krishnamoorthy, N.
Prabhakar, G.
Powiązania:
https://bibliotekanauki.pl/articles/2086849.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft starting of three phase induction motor
symmetrical angle controller
AC voltage controller
power quality improvement
rozruch trójfazowego silnika indukcyjnego
symetryczny kontroler kąta
kontroler napięcia prądu przemiennego
poprawa jakości energii elektrycznej
Opis:
PIC microcontroller has a vital role in various types of controllers and nowadays the presence of PIC microcontroller is unavoidable in most control applications. This paper describes the enhancement of soft starting of induction motors using PIC microcontroller. Soft starting is required for the induction motors with reduced applied voltages so that the peak starting current is reduced and the startup of the motor is smooth with controlled torque and reduced mechanical vibrations, reduced starting current with correspondingly reduced bus voltage drops. While many of the available schemes of soft starting offer better results in view of smooth starting process, the proposed methodology offers soft starting as well as it cares about the source current quality. In contrast to the conventional multistep starting scheme, in this work a continuously controlled starting scheme is proposed. The three phase AC voltage controller topology is used as the core controller. In each of the half cycles, instead of a single conduction period with a single delay angle, the proposed AC voltage controller is switched symmetrically in each half cycle with multiple pulses in each quarter cycle. Symmetrically placed fixed numbers of switching pulses are used. The paper also describes the various time ratio controls namely the phase angle controller, the extinction angle controller and the symmetrical angle controller. The design aspects of the proposed soft starting scheme and the validation of the proposed system in the MATLAB SIMULINK environment are presented in this paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136746, 1--12
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel source side power quality improved soft starting of three-phase induction motor using a symmetrical angle controller through pic microcontroller
Autorzy:
Selvaperumal, S.
Krishnamoorthy, N.
Prabhakar, G.
Powiązania:
https://bibliotekanauki.pl/articles/2128138.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft starting of three phase induction motor
symmetrical angle controller
AC voltage controller
power quality improvement
rozruch trójfazowego silnika indukcyjnego
kontroler kąta symetryczny
kontroler napięcia prądu przemiennego
poprawa jakości energii elektrycznej
Opis:
PIC microcontroller has a vital role in various types of controllers and nowadays the presence of PIC microcontroller is unavoidable in most control applications. This paper describes the enhancement of soft starting of induction motors using PIC microcontroller. Soft starting is required for the induction motors with reduced applied voltages so that the peak starting current is reduced and the startup of the motor is smooth with controlled torque and reduced mechanical vibrations, reduced starting current with correspondingly reduced bus voltage drops. While many of the available schemes of soft starting offer better results in view of smooth starting process, the proposed methodology offers soft starting as well as it cares about the source current quality. In contrast to the conventional multistep starting scheme, in this work a continuously controlled starting scheme is proposed. The three phase AC voltage controller topology is used as the core controller. In each of the half cycles, instead of a single conduction period with a single delay angle, the proposed AC voltage controller is switched symmetrically in each half cycle with multiple pulses in each quarter cycle. Symmetrically placed fixed numbers of switching pulses are used. The paper also describes the various time ratio controls namely the phase angle controller, the extinction angle controller and the symmetrical angle controller. The design aspects of the proposed soft starting scheme and the validation of the proposed system in the MATLAB SIMULINK environment are presented in this paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136746, 1--12
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies