Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "poly(L-lactide-co-trimethylene carbonate)" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Blends of poly(L-lactide) and poly(L-lactide-co-trimethylene carbonate) as promising materials for bone and cartilage tissue engineering
Autorzy:
Marchewka, J.
Laska, J.
Powiązania:
https://bibliotekanauki.pl/articles/286020.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poly(L-lactide)
poly(L-lactide-co-trimethylene carbonate)
polymer blends
mechanical properties
biomaterials
Opis:
The aim of this work was to evaluate the properties of polymer blends of poly(L-lactide) and poly(L-lactide-co-trimethylene carbonate) 15/85 and to select two compositions to be used to prepare the materials for bone and cartilage tissue engineering. PLLA and PLLATMC as the polymers with significantly different mechanical properties could be used to prepare a wide range of polymer blends. They were investigated by ultimate tensile strength and Young modulus measurements. Considering similar mechanical properties to these types of human tissues PLLA:PLLATMC 80:20 and 30:70 blends have been chosen as appropriate materials for bone and cartilage engineering, respectively. The materials were examined by thermal analysis (thermogravimetry and differential scanning calorimetry), ATR-FTIR spectroscopy and surface analysis (roughness and contact angle measurements). Miscibility of two polymers was discussed. High thermal stability of the blends allow to process them by fused deposition modelling which is one of the most promising methods for the manufacturing of computationally designed scaffolds. Based on the results of thermal analysis at least partial miscibility of PLLA and PLLATMC in the examined blends is indicated. Detailed interpretation of ATR-FTIR spectra let to distinguish the polymers despite their structural similarities. Surface properties of the materials depend on the preparation method and on their form.
Źródło:
Engineering of Biomaterials; 2018, 21, 145; 8-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioresorbowalne kopolimery L-laktydu i węglanu trimetylenu w kontrolowanym uwalnianiu paklitaksleu
Bioresorbable copolymers of L- lactide and trimethylene carbonate for controlled delivery of paclitaxel
Autorzy:
Musiał-Kulik, M.
Ksperczyk, J.
Pastusiak, M.
Gębarowska, K.
Janeczek, H.
Libera, M.
Zając, M.
Powiązania:
https://bibliotekanauki.pl/articles/285568.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktyd-ko-węglan trimetylenu)
paklitaksel
restenoza
degradacja hydrolityczna
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
restenosis
hydrolytic degradation
Opis:
Skład komonomerów jak również mikrostruktura łańcucha polimerowego są ważnymi czynnikami determinującymi sposób degradacji polimeru oraz profil uwalniania leku. Celem badań było określenie wpływu mikrostruktury łańcucha na uwalnianie paklitakselu. Dwa rodzaje PLATMC (70:30) zostały użyte do przygotowania matryc z 3% i 5% zawartością leku oraz matryc bez leku. Materiały zostały zsyntezowane w różnych temperaturach i dlatego różniły się pod względem właściwości fizykochemicznych. Wszystkie matryce badano za pomocą spektroskopii NMR, GPC, DSC, SEM zarówno przed jak i w czasie procesu degradacji. Ilość uwolnionego paklitakselu szacowano przy pomocy HPLC. Otrzymane wyniki wskazują, iż podczas inkubacji w mikrostrukturze łańcucha kopolimerowego nie zaszły znaczące zmiany. Wolniejszy profil uwalniania odnotowano w przypadku PLATMC o wyższym współczynniku randomizacji, zsyntezowanego w wyższej temperaturze. Kopolimer ten wydaje się być atrakcyjnym materiałem do tworzenia systemów kontrolowanego uwalniania paklitakselu.
Comonomers composition as well as the chain microstructure are very important factors determining time of polymer degradation and drug release profile. In this study it was aimed to determine the influence of chain microstructure on paclitaxel release. Two types of PLATMC (70:30) were used to prepare matrices with 3% and 5% of drug and also drug free matrices. They were synthesised at different temperature and thus differed in physicochemical properties. All of the matrices were investigated before and during hydrolytic degradation process by means of NMR spectroscopy, GPC, DSC, SEM. The amount of liberated paclitaxel was assessed with the use of HPLC. The obtained results indicated no significant changes in chain microstructure during incubation period of time. Slower release profile was noticed for PLATMC synthesised at higher temperature and possessed higher randomisation ratio. This type of copolymer seems to be very attractive candidate for controlled paclitaxel delivery systems.
Źródło:
Engineering of Biomaterials; 2011, 14, 105; 25-28
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterylizacja radiacyjna bioresorbowalnych kopolimerów zawierających lek cytostatyczny
Radiation sterilization of bioresorbable copolymers with the cytostatic drug
Autorzy:
Musiał-Kulik, M.
Gębarowska, K.
Janeczek, H.
Pastusiak, M.
Kasperczyk, J.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/284740.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktydo-ko-węglan trimetylen)
paklitaksel
promieniowanie gamma
napromienianie wiązką elektronów
sterylizacja
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
gamma irradiation
electron beam radiation
sterilization
Opis:
Istnieje wiele metod sterylizacji wyrobów medycznych. Jednak najbardziej użytecznymi metodami sterylizacji syntetycznych, bioresorbowalnych polimerów wydają się być promieniowanie gamma oraz napromienianie wiązką elektronów (EB). Celem tej pracy było określenie wpływu wspomnianych metod na trzy rodzaje matryc - zawierających 3%, 5% paklitakselu oraz matryc bez leku. Badane matryce otrzymano z dwóch rodzajówpoli(L-laktydo-ko-węglanu trimetylenu) zsyntezowanych w 150°C (P1) oraz 120°C (P2). Nie zaobserwowano znaczących różnic w składzie komonomerów matryc sterylnych i niesterylnych, zawierających paklitaksel, jak i matryc bez leku. Spadek temperatury zeszklenia (Tg) wynikał ze zmniejszenia się średniej długości bloków laktydylowych oraz węglanowych, a także utraty Mn po procesie sterylizacji. Zauważalne były niewielkie różnice we właściwościach fizykochemicznych matryc napromienianych promieniowaniem gamma oraz wiązką elektronów. Otrzymane wyniki pokazują, iż lepszą metodą sterylizacji poli(L-laktydo-ko-węglanu trimetylenu) wydaje się być napromienianie wiązką elektronów.
There are many methods of sterilization approved for medical devices. However, the most usable methods of synthetic, bioresorbable polymers sterilization seem to be gamma radiation and electron beam irradiation (EB). The aim of this work was to determine the impact of mentioned methods on three types of matrices - containing 3%, 5% of paclitaxel and also drug free matrices. The studied matrices were obtained from two poly(L-lactide-co-trimethylene-carbonates) synthesized at 150°C (P1) and 120°C (P2). No significant differences of comonomers' composition were observed in sterile and non-sterile matrices containing paclitaxel as well as drug free matrices. The decrease of the glass transition temperature (Tg) resulted from decrease of the lactidyl and carbonate units' content and the Mn loss after radiation. Small dissimilarities of physicochemical features between gamma and EB radiated matrices were noticeable. Thus, the obtained data showed that better method of sterilization of poly(L-lactide-co-trimethylene carbonates) seems to be electron beam radiation.
Źródło:
Engineering of Biomaterials; 2013, 16, 118; 18-22
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterylizacja radiacyjna bioresorbowalnych kopolimerów zawierających lek cytostatyczny
Radiation sterilization of bioresorbable copolymers with the cytostatic drug
Autorzy:
Musiał-Kulik, M.
Gębarowska, K.
Janeczek, H.
Pastusiak, M.
Kasperczyk, J.
Dobrzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/286205.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
poli(L-laktydo-ko-węglan trimetylen)
paklitaksel
promieniowanie gamma
napromieniowanie wiązką elektronów
sterylizacja
poly(L-lactide-co-trimethylene carbonate)
paclitaxel
gamma irradiation
electron beam radiation
sterilization
Opis:
Istnieje wiele metod sterylizacji wyrobów medycznych. Jednak najbardziej użytecznymi metodami sterylizacji syntetycznych, bioresorbowalnych polimerów wydają się być promieniowanie gamma oraz napromienianie wiązką elektronów (EB). Celem tej pracy było określenie wpływu wspomnianych metod na trzy rodzaje matryc - zawierających 3%, 5% paklitakselu oraz matryc bez leku. Badane matryce otrzymano z dwóch rodzajów poli(L-laktydo-ko-węglanu trimetylenu) zsyntezowanych w 150°C (P1) oraz 120°C (P2). Nie zaobserwowano znaczących różnic w składzie komonomerów matryc sterylnych i niesterylnych, zawierających paklitaksel, jak i matryc bez leku. Spadek temperatury zeszklenia, Tg, wynikał ze zmniejszenia się średniej długości bloków laktydylowych oraz węglanowych, a także utraty Mn po procesie sterylizacji. Zauważalne były niewielkie różnice we właściwościach fizykochemicznych matryc napromienianych promieniowaniem gamma oraz wiązką elektronów. Otrzymane wyniki pokazują, iż lepszą metodą sterylizacji poli(L-laktydo-ko-węglanu trimetylenu) wydaje się być napromienianie wiązką elektronów.
There are many methods of sterilization approved for medical devices. However, the most usable methods of synthetic, bioresorbable polymers sterilization seem to be gamma radiation and electron beam irradiation (EB). The aim of this work was to determine the impact of mentioned methods on three types of matrices - containing 3%, 5% of paclitaxel and also drug free matrices. The studied matrices were obtained from two poly(L-lactide-co-trimethylene-carbonates) synthesized at 150°C (P1) and 120°C (P2). No significant differences of comonomers' composition were observed in sterile and non-sterile matrices containing paclitaxel as well as drug free matrices. The decrease of the glass transition temperature, Tg, resulted from decrease of the lactidyl and carbonate units' content and the Mn loss after radiation. Small dissimilarities of physicochemical features between gamma and EB radiated matrices were noticeable. Thus, the obtained data showed that better method of sterilization poly(L-lactide-co-trimethylene carbonates) seems to be electron beam radiation.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 74-78
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron beam sterilization of implantable rods with risperidone and with 17-β-estradiol: a structural, thermal and morphology study
Autorzy:
Wilińska, Justyna
Turek, Artur
Borecka, Aleksandra
Rech, Jakub
Kasperczyk, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/306226.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sterylizacja wiązką elektronów
17β-estradiol
rysperydon
electron beam sterilization
implantable rods
poly(L-lactide-co-glycolide-co-trimethylene carbonate)
risperidone
17-β-estradiol
Opis:
Poly(L-lactide-co-glycolide-co-trimethylene carbonate) rods with risperidone and 17-β-estradiol were sterilized by electron beam irradiation. The aim of the study was to assess electron beam irradiation impact on terpolymer composition, chain microstructure, glass transition temperature, molecular weight and the morphological features of rods. Methods: Hot melt extrusion in the formulation of rods was applied. Sterilization of the rods was performed by electron beam in an electron beam accelerator (10 MeV, 360 mA, 25 kGy). The following methods in the development of rods were applied: nuclear magnetic resonance, differential scanning calorimetry, gel permeation chromatography and scanning electron microscopy. Results: Sterilization influenced only glass transition temperature in blind rods and rods with risperidone. As for the other parameters, no significant changes were observed as far as a sterilization effect is concerned. However, some changes were noted after introducing drug substances and after extrusion. Conclusions: Electron beam irradiation of rods with risperidone and rods with 17-β-estradiol is an adequate method for sterilizing implantable drug delivery systems.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 39-47
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies