Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "plasma temperature" wg kryterium: Temat


Tytuł:
Influence of dense deuterium plasma pulses on materials in Plasma Focus device
Autorzy:
Ivanov, L.
Pimenov, V.
Maslyaev, S.
Dyomina, E.
Gribkov, V.
Mezzetti, F.
DeChiara, P.
Powiązania:
https://bibliotekanauki.pl/articles/146708.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
high-temperature plasma
material science
plasma focus
Opis:
Experiments on the influence of high-temperature plasma nanosecond pulse radiation, as generated in plasma focus device, on the W-Cu pseudoalloy, V-35at%Ti alloy, austenitic chromium-manganese 10Cr12Mn20W and 25Cr12Mn20W steels have been carried out. Features of damages, phase-structural transformations and chemical content changes in those materials under such irradiation were investigated.
Źródło:
Nukleonika; 2000, 45, 3; 203-207
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-channel X-ray detection head for diagnostics of plasma in noisy environment
Autorzy:
Ryć, L.
Kaczmarczyk, J.
Martinez, J. F.
Scholz, M.
Słysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/148717.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
high-temperature plasma
semiconductor detector
X-ray diagnostics
Opis:
A compact, three-channel, noise-resistant detection head based on semiconductor detectors has been built for the diagnostics of X-ray emission from plasmas. It is useful in the energy range of 0.5–20 keV.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 95-97
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time-integrated diagnostics of X-ray emission from PALS and PF 1000 : preliminary results
Autorzy:
Ryć, L.
Krása, J.
Juha, L.
Kaczmarczyk, J.
Paduch, M.
Parys, P.
Tomaszewski, K.
Scholz, M.
Powiązania:
https://bibliotekanauki.pl/articles/148024.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
high-temperature plasma
semiconductor detector
thermoluminescent detector
X-ray diagnostics
Opis:
Thermoluminescent and semiconductor detectors operating in an integrating mode have been applied to the measurement of X-ray flashes of high intensity from large plasma facilities. A detection head of special kind has been developed to perform comparison measurements with the use of the detectors of both kinds.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 41-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrathin oxynitride films for CMOS technology
Autorzy:
Beck, R.B.
Jakubowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/308025.pdf
Data publikacji:
2004
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
MOS technology
gate stack
ultrathin oxynitride layers
high temperature processing
plasma processing
Opis:
In this work, a review of possible methods of oxynitride film formation will be given. These are different combinations of methods applying high-temperature oxidation and nitridation, as well as ion implantation and deposition techniques. The layers obtained using these methods differ, among other aspects in: nitrogen content, its profile across the ultrathin layer,... etc., which have considerable impact on device properties, such as leakage current, channel mobility, device stability and its reliability. Unlike high-temperature processes, which (understood as a single process step) usually do not allow the control of the nitrogen content at the silicon-oxynitride layer interface, different types of deposition techniques allow certain freedom in this respect. However, deposition techniques have been believed for many years not to be suitable for such a responsible task as the formation of gate dielectrics in MOS devices. Nowadays, this belief seems unjustified. On the contrary, these methods often allow the formation of the layers not only with a uniquely high content of nitrogen but also a very unusual nitrogen profile, both at exceptionally low temperatures. This advantage is invaluable in the times of tight restrictions imposed on the thermal budget (especially for high performance devices). Certain specific features of these methods also allow unique solutions in certain technologies (leading to simplifications of the manufacturing process and/or higher performance and reliability), such as dual gate technology for system-on-chip (SOC) manufacturing.
Źródło:
Journal of Telecommunications and Information Technology; 2004, 1; 62-69
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of low temperature plasma nox control system for marine diesel engine
Autorzy:
Borkowski, T.
Myśków, J.
Hołub, M.
Kalisiak, S.
Powiązania:
https://bibliotekanauki.pl/articles/243384.pdf
Data publikacji:
2007
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
marine diesel engine
exhaust emission gas treatment
low temperature plasma reactor
Opis:
The control of nox emissions from marine engines proves a challenge. Diesel engine manufacturers have been investigating a variety of methods with aim of reducing nox emissions. Currently, the plasma technology is undergoing rapid development in application to diesel engine exhausts. A combination of non-thermal plasma with catalysts can be referred to plasma assisted catalysts technology. This paper briefly describes research efforts aimed at non-thermal plasma reactor development for ship use with primary focus on NO oxidation condition. The part scale plasma reactor models have been designed and manufactured for the purpose of this trial. Exhaust emission plasma after-treatment module was fitted on exhaust outlet path of the marine test bed engine for fractional exhaust gas stream examination. Subsequently, the comprehensive series of trials were performed to assess the exhaust flow properties of the main exhaust channel and plasma reactor by-pass duct. Emission measurements were carried out on engine at steady-state operation. The NO reaction activity was a major task of the experiment and throughout the measurements, the engine outlet nox levels (NO and NO2) were monitored with simultaneous NO, NO2, N2O level recording after NTP reactor.
Źródło:
Journal of KONES; 2007, 14, 3; 91-99
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of thermal state in reactor during plasma pyrolysis of polymers
Ocena stanu cieplnego w reaktorze podczas pirolizy plazmowej polimerów
Autorzy:
Szuszkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/328133.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
piroliza plazmowa
temperatura
warunki termiczne
polimer
plasma pyrolysis
temperature
thermal conditions
polymer
Opis:
Thermal conditions existing in the reactor, especially around the plasma jet, greatly influence on the course of the plasma pyrolysis including synthesis of derivative compounds. Measurements of the temperature distribution in the reactor will be helpful in carrying out the experiment of the plasma pyrolysis of polymers and also will be utilized to build the model of the plasma pyrolysis.
Warunki termiczne panujące w reaktorze, szczególnie w otoczeniu strumienia plazmy, mają istotny wpływ na przebieg pirolizy plazmowej, w tym na syntezę związków wtórnych. Pomiar rozkładu temperatury w reaktorze będzie pomocny w przeprowadzaniu eksperymentu pirolizy plazmowej polimerów, a także posłuży do budowy modelu pirolizy plazmowej.
Źródło:
Diagnostyka; 2009, 2(50); 51-54
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of low temperature plasma capabilities to modify the structure and function of bio-polymers
Autorzy:
Motrescu, I.
Hara, T.
Ogino, A.
Tanaka, S.
Fujiwara, T.
Kawagishi, H.
Kodani, S.
Popa, G.
Nagatsu, M.
Powiązania:
https://bibliotekanauki.pl/articles/385288.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
biopolymers
biomolecules
low temperature plasma
modification
plasma processing
Opis:
The possibility to modify biopolymers using low temperature plasma is investigated. Two types of plasma are employed in this study: an atmospheric pressure plasma and a low pressure microwave plasma. In both cases changes of the structure and function of the exposed molecules are reported, the effects being stronger for the low-pressure plasma irradiation.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 150-152
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of low temperature inactivation of spores using microwave excited air plasma
Autorzy:
Nagatsu, M.
Singh, M. K.
Zhao, Y.
Fujioka, Y.
Ogino, A.
Powiązania:
https://bibliotekanauki.pl/articles/385185.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
plasma sterilization
low temperature plasma
microwave plasma
air plasma
VUV
radicals
Opis:
In the present study, we investigated the inactivation characteristics and contribution of different inactivating factors generated in a low temperature and low pressure nitrogen, oxygen and air-simulated plasma for the inactivation of Geobacillus stearothermophilus spores. We used three optical filters i.e. thin quartz (lambda>180 nm), lithium fluorine (LiF, lambda>120 nm) and Pyrex glass (lambda>300 nm) plates to identify the most efficient wavelength range. The effect of optical radiations alone was studied through placing a small isolated and evacuated chamber with spore sample inside the plasma chamber.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 108-111
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania tribologiczne powłok ceramicznych natryskiwanych plazmowo
The tribological studies of plasma-sprayed ceramic coatings
Autorzy:
Feldshtein, E.
Laber, A.
Devojno, O.
Yatskievich, O.
Powiązania:
https://bibliotekanauki.pl/articles/189380.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
natryskiwanie plazmowe
powłoki ceramiczne
współczynnik tarcia
temperatura
zużycie
plasma spraying
ceramic coatings
friction coefficient
temperature
wear
Opis:
W artykule przedstawiono wpływ powłok ceramicznych Al2O3, Al2O3-B i Al2O3-Mo natryskiwanych plazmowo i rodzaju tarcia na właściwości tribologiczne, tj. współczynniki tarcia, zużycie, temperaturę węzła tarcia. Jako grubość powłok przyjęto 0,5-0,7 mm, materiałem, na który nakładano powłoki była stal C45.
Plasma-sprayed coatings on the base of ceramic powders Al2O3, Al2O3-B and Al2O3-Mo were investigated. The thickness of coatings after processing was equal to 0.5–0.7 mm, the base material was steel C45. The analysis of metallographic samples of coatings allowed us to find that ceramic coatings consists of quasi-molten and then harden particles. The molten intensity of coating material Al2O3-B is more in comparison with other materials. Research using friction-wear machine of the Amsler type determined that values of the friction coefficient for coatings are practically equal when dry friction. The presence of gearbox oil decreases the friction coefficients of the researched coatings by about 3 to 4 times in comparison with dry friction conditions. During dry friction and friction with gearbox oil, the surface of Al2O3 coating abrades more quickly in comparison with coats alloyed. The relative solid wear of ceramic coating alloyed by boron is considerably smaller in comparison with other coatings. The presence of oil decreases relative solid wear of researched coatings more then 20 times in comparison with dry friction conditions according to the peculiarity of friction pair work. The presence of oil guarantees the removal of wear products successfully from the friction area.
Źródło:
Tribologia; 2010, 2; 23-34
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of High Temperature Annealing on Fluorine Distribution Profile and Electro-Physical Properties of Thin Gate Oxide Fluorinated by Silicon Dioxide RIE in CF4 Plasma
Autorzy:
Kalisz, M.
Głuszko, G.
Beck, R. B.
Powiązania:
https://bibliotekanauki.pl/articles/308059.pdf
Data publikacji:
2010
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
capacitance-voltage characteristics
current-voltage characteristics
fluorine plasma
high temperature annealing process
radio frequency reactive ion etching
Opis:
This study describes the effects of high temperature annealing performed on structures fluorinated during initial silicon dioxide reactive ion etching (RIE) process in CF4 plasma prior to the plasma enhanced chemical vapour deposition (PECVD) of the final oxide. The obtained results show that fluorine incorporated at the PECVD oxide/Si interface during RIE is very stable even at high temperatures. Application of fluorination and high temperature annealing during oxide layer fabrication significantly improved the properties of the interface (Ditmb decreased), as well as those of the bulk of the oxide layer (Qeff decreased). The integrity of the oxide (higher Vbd ) and its uniformity (Vbd distribution) are also improved.
Źródło:
Journal of Telecommunications and Information Technology; 2010, 1; 25-28
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CVD diamond detectors for fast alpha particles escaping from the tokamak D-T plasma
Autorzy:
Wodniak, I.
Drozdowicz, K.
Dankowski, J.
Gabańska, B.
Igielski, A.
Kurowski, A.
Marczewska, B.
Nowak, T.
Woźnicka, U.
Powiązania:
https://bibliotekanauki.pl/articles/146634.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
CVD diamond detector
lost alpha particles
high temperature plasma diagnostics
Opis:
Measurements of the so-called lost alpha particles escaping from thermonuclear plasma in future tokamaks (such as ITER) for energy production would be essential for monitoring the energy balance in these devices. The detection would have to be carried out in a harsh environment (with high nuclear radiation fluxes, high temperature, etc.), which limits the use of common semiconductors for charged particle detection. Diamond seems to be an attractive material for alpha particle detectors in these conditions. In this paper an analysis of properties of a diamond detector for spectrometric alpha measurements is reported. A high purity CVD (chemical vapour deposition) single crystal diamond detector was used, fabricated for this dedicated application by the Diamond Detector Ltd. The energy calibration was carried out using a triple alpha particle isotope source, AMR33 (239Pu, 241Am, 244Cm). A very good energy resolution, ca. 20 keV at ca. 5.5 MeV had been obtained, which is comparable to that of the silicon detector. The linearity of the diamond detector amplitude response to the alpha particle energy was analyzed with the use of mono-energetic (0.4–2 MeV) ion beam from a Van de Graaff accelerator. Results of the measurements using the AMR33 source deviate at most 30 keV from the calibration line obtained in this way.
Źródło:
Nukleonika; 2011, 56, 2; 143-147
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accelerated Ageing of the Implantable, Ultra-Light, Knitted Medical Devices Modified by Low-Temperature Plasma Treatment – Part 1. Effects on the Physical Behaviour
Badania przyspieszonego starzenia implantowalnych, ultra lekkich, dzianych wyrobów medycznych modyfikowanych powierzchniowo plazmą nisko temperaturową – Część 1. Wpływ na właściwości fizyczne
Autorzy:
Struszczyk, M. H.
Gutowska, A.
Pałys, B
Cichecka, M
Kostanek, K
Wilbik-Hałgas, B.
Kowalski, K.
Kopias, K.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/233165.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
implants
ultra-light medical devices
knitted structures modification
low-temperature plasma
physical behaviour
starzenie implantów
wyroby medyczne
właściwości fizyczne
dziane wyroby medyczne
Opis:
The aim of the research was to validate the effects of accelerated ageing on the physical properties of newly-designed ultra-light three dimensional (3-D) knitted implants undergoing one-sided modification by low-temperature plasma treatment using low molecular weight fluoroorganic donors. The influence of storing the knitted medical devices for 1 or 2 years at accelerated conditions was studied taking into account their selected physical properties in relation to key usable features. The presented study is a continuation of previous research for the elaboration of a new-idea of three-dimensional implants applied in hernioplasty (general surgery), vaginoplasty and urinary incontinence treatment (urologynaecology).
Celem prowadzonych badań była walidacja wpływu przyspieszonego starzenia na fizyczne właściwości nowo opracowanej konstrukcji ultralekkich, trójwymiarowych dzianych implantów poddanych jednostronnej modyfikacji nisko temperaturową plazmą w obecności niskocząsteczkowego związku fluoroorganicznego. Ocenie poddano wybrane kluczowe z punktu widzenia aspektów użytkowych, właściwości fizyczne zaprojektowanych dzianych wyrobów medycznych poddanych procesowi przyspieszonego starzenia. Prezentowana praca stanowi kontynuację wcześniejszych badań dotyczących opracowania trójwymiarowych implantów stosowanych w rekonstrukcji przepuklin (chirurgia ogólna), plastyce pochwy lub do chirurgicznego leczenia nietrzymania moczu (urologinekologia).
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 121-127
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczenie stężenia struktur azbestowych w powietrzu – nowa metoda
Determination of the concentration of asbestos structures in the air – a new method
Autorzy:
Rożkowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/2062730.pdf
Data publikacji:
2012
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
azbest
ochrona powietrza
zanieczyszczenie powietrza azbestem
metoda badawcza
transmisyjny mikroskop elektronowy
niskotemperaturowa plazma
asbestos
air protection
air contamination by asbestos
research method
transmission electron microscope
low-temperature oxygen plasma
Opis:
Azbest jest toksycznym minerałem, który powoduje wyniszczające efekty zdrowotne u ludzi. Z powodu jego toksyczności konieczne jest posiadanie skutecznych metod do wykrywania i kwantyfikacji azbestu w środowisku. Przez lata opracowano wiele metod, jednak każda z tych metod ma swoje mocne i słabe strony. Publikacja przedstawia kompleksową metodę kontroli stężeń struktur azbestowych w powietrzu. Metoda zawiera procedury: lokalizacji punktów pobierania próbek, pobierania próbek z powietrza, przygotowania próbek do analizy, identyfikacji struktur na podstawie cech morfologicznych, chemicznych, strukturalnych, zliczania struktur w próbce i wyznaczania stężenia struktur azbestowych w powietrzu.
Asbestos is a toxic mineral known to produce debilitating health effects in humans. Because of its toxicity, it is necessary to have effective methods to detect asbestos in the environment. Over the years, a number of methods have been developed, but each method has its own strengths and weaknesses. The paper presents the composite method for the control of concentrations of asbestos structures in the air. The method involves the following procedures: location of sample collection points, collection of air samples, preparation of samples for analysis, identification of structures based on morphological, chemical and structural features, counting of asbestos structures in the sample and determination of concentrations of asbestos structures in the air.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2012, 450; 83--90
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Modified Knitted Hernia Implants after Implantation: I. Biological Effect on the Structural and Usable Properties
Poimplantacyjna ocena modyfikowanych dzianych implantów do zaopatrywania przepuklin: I. Wpływ implantacji na właściwości użytkowe oraz strukturalne
Autorzy:
Kostanek, K.
Struszczyk, M. H.
Chrzanowski, M.
Żywicka, B.
Paluch, D.
Szadkowski, M.
Gutowska, A.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/233588.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
knitted hernia implants
low temperature plasma treatment
biological evaluation
dziane implanty leczenie przepukliny
niska temperatura plazmy
ocena biologicznych
Opis:
The purpose of this article is to discuss the solution of the main clinical adverse events occurring in less invasive reconstruction of hernia. The study attempted to design the knitted implants, contributing to reduce the risk of adhesion to the viscera. Specially designed knitting structure of the hernia implant allowed to introduce the one-side enhancement of the surface in the form of loops stitched-out of the surface accelerated the connective tissue in-growth. The opposite side was modified the treatment in low-temperature plasma of low molecular weight fluorogenic compound resulted in the deposition of fluoropolymer nano-layer. The effect of the modification on the adhesion of implant to viscera was studied in vivo. Additionally, the influence of the implantation time on the structural properties, the connective tissue covering implants single monofilaments as well as the stability of the fluoropolymer layer formed during the implantation were detailed investigated.
Artykuł omawia techniczną próbę rozwiązania głównych problemów występujących w rekonstrukcjach przepukliny, wykonywanych techniką małoinwazyjną. W badaniach podjęto próbę zaprojektowania dzianego implantu, którego właściwości wpływają na zmniejszenie ryzyka jego adhezji do narządów wewnętrznych. Specjalnie opracowana struktura dziewiarska implantu do zaopatrywania przepuklin pozwoliła na uzyskanie jednostronnego rozwinięcia powierzchni w postaci wystających z powierzchni pętelek wspomagających proces wgajania tkanką łączną. Druga powierzchnia implantu została poddana modyfikacji w środowisku plazmy niskotemperaturowej niskocząsteczkowego związku fluoroorganicznego prowadząc do uformowania nanowarstwy fluoropolimeru. Umożliwiło to obniżenie ryzyka adhezji implantu dzianego do narządów wewnętrznych, co potwierdzono w badaniach in vivo. Prowadzono także ocenę wpływu czasu implantacji na właściwości strukturalne implantu, stopień pokrycia tkanką łączną pojedynczych monofilamentów oraz stabilność uformowanej nanowarstwy fluoropolimeru.
Źródło:
Fibres & Textiles in Eastern Europe; 2013, 6 (102); 79-83
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kryteria modelowania numerycznego niskotemperaturowej plazmy nietermicznej
Criteria for numerical modeling of low-tempe- rature non-thermal plasma
Autorzy:
Pianko-Oprych, P.
Powiązania:
https://bibliotekanauki.pl/articles/2072177.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
niskotemperaturowa plazma nietermiczna
modelowanie numeryczne
CFD
low-temperature non-thermal plasma
numerical modeling
Opis:
W pracy omówiono krytyczne parametry niezbędne do właściwego zdefiniowania problemu obliczeniowego z udziałem niskotemperaturowej plazmy nietermicznej w reaktorze typu DBD. Dobór tych parametrów jest zagadnieniem złożonym z uwagi na nieliniowy charakter zjawisk, przebiegających podczas wyładowań elektrycznych. Pomocne w tym zakresie są kody obliczeniowe numerycznej mechaniki płynów, które umożliwiają ilościowy opis nieliniowych relacji pomiędzy zmiennymi w czasie parametrami.
Critical parameters necessary to properly define a computational problem involving a low-temperature non-thermal plasma reactor of DBD type are discussed in the paper. A choice of these parameters is a complex issue due to nonlinear nature of the phenomena which take place during the electrical discharge. The codes of computational fluid dynamics are helpful in this issue. They enable the quantitative description of non-linear relationships between the time-dependent parameters.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 5; 459--461
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies