Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "plasma focus (PF)" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Temporal distribution of linear densities of the plasma column in a plasma focus discharge
Autorzy:
Cikhardtova, B.
Kubeš, P.
Cikhardt, J.
Paduch, M.
Zielinska, E.
Kravárik, J.
Řezáč, K.
Kortanek, J.
Šíla, O.
Powiązania:
https://bibliotekanauki.pl/articles/147356.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus (PF)
plasma pinch
plasma diagnostics
Opis:
Experiments were carried out on the PF-1000 plasma focus device, with a deuterium filling and with deuterium puffing from a gas-puff nozzle placed on the axis of the anode face. The current was reaching 2 MA. 15 interferometric frames from one shot were recorded with a Nd:YLF laser and a Mach–Zehnder interferometer, with 10–20 ns delay between the frames. As a result, the temporal and spatial distribution of the linear densities and the radial and axial velocities of the moving of plasma in the dense plasma column could be estimated.
Źródło:
Nukleonika; 2015, 60, 2; 315-318
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic field measurements on PF - 1000 and PF - 3 facilities: current sheath structure and neutron scaling
Autorzy:
Krauz, V. I.
Mitrofanov, K. N.
Scholz, M.
Myalton, V. V.
Paduch, M.
Grabovskii, E. V.
Karpinski, L.
Koidan, V. S.
Vinogradov, V. P.
Vinogradova, Y. V.
Zielinska, E.
Powiązania:
https://bibliotekanauki.pl/articles/147526.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus (PF)
magnetic probe
current sheath
neutron scaling
Opis:
The comparative analysis of the magnetic field distribution, the dynamics and structure of the plasma current sheath, and the neutron yield scaling in two largest plasma focus facilities, PF-3 and PF-1000 is done. The power-low dependence of the neutron yield on the current in the imploding plasma sheath has been demonstrated experimentally. For the first time the presence of the Bz magnetic field components is experimentally shown.
Źródło:
Nukleonika; 2012, 57, 2; 201-204
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Important issues in high - current plasma experiments of the Z - pinch type
Autorzy:
Sadowski, M. J.
Scholz, M.
Powiązania:
https://bibliotekanauki.pl/articles/147694.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Z-pinch
X-pinch
wire-array Z-pinch
gas-puffed Z-pinch
plasma focus (PF)
Opis:
This paper is based on an invited lecture given at the 10th International Workshop and Summer School "Towards Fusion Energy", which was held in Kudowa Zdrój, Poland, on June 12–18, 2011. A concise review is presented of the known experimental results on various plasma Z-pinch experiments supplied by high-voltage and high-current pulsed power generators. The most important issues and the most valuable results in this domain are highlighted. A broad class of various Z-pinches is considered, including simple inter-electrode discharges, single exploding wires, so-called X-pinches, cylindrical wire-array Z-pinches, radial wire-array discharges, conical wire-array experiments, and gas-puffed Z-pinches. Non-cylindrical Z-pinch discharges (often called plasma focus experiments) are also briefly characterized. The most important characteristics of each category of experiments are outlined. Particular attention is paid to fusion-oriented high-power Z-pinch experiments and the problems encountered in experiments with various sophisticated fusion targets. The main issues in the described Z-pinch experiments are identified. Finally, new trends in the dense Z-pinch research are described.
Źródło:
Nukleonika; 2012, 57, 1; 11-24
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Installations based on high efficiency high repetition rate miniature DPF chambers for material science
Autorzy:
Dubrovsky, A.
Gribkov, V.
Powiązania:
https://bibliotekanauki.pl/articles/146795.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
miniature focus chamber
PF instalation
Opis:
The report describes two DPF installations based on a miniature plasma focus chamber: the installation PF-3 of the energy store W = 3 kJ and the installation PF-0.2 (W = 200 J). The possibility of an adaptation of the small DPF device for the experimental samples irradiation is reported. A new construction intended for experiments with samples of various materials is presented.
Źródło:
Nukleonika; 2000, 45, 3; 159-162
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of plasma interactions with tungsten targets in PF-1000U facility
Autorzy:
Ladygina, M. S.
Skladnik-Sadowska, E.
Zaloga, D. R.
Sadowski, M. J.
Kubkowska, M.
Kowalska-Strzeciwilk, E.
Krawczyk, N.
Paduch, M.
Miklaszewski, R.
Garkusha, I. E.
Powiązania:
https://bibliotekanauki.pl/articles/147524.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma-surface interaction
plasma streams
tungsten
plasma focus
PF-1000U
Opis:
This paper presents results of experimental studies of tungsten samples of 99.95% purity, which were irradiated by intense plasma-ion streams. The behaviour of tungsten, and particularly its structural change induced by high plasma loads, is of great importance for fusion technology. The reported measurements were performed within a modifi ed PF-1000U plasma-focus facility operated at the IFPiLM in Warsaw, Poland. The working gas was pure deuterium. In order to determine the main plasma parameters and to study the behaviour of impurities at different instants of the plasma discharge, the optical emission spectroscopy was used. The dependence of plasma parameters on the initial charging voltage (16, 19 and 21 kV) was studied. Detailed optical measurements were performed during interactions of a plasma stream with the tungsten samples placed at the z-axis of the facility, at a distance of 6 cm from the electrode outlets. The recorded spectra showed distinct WI and WII spectral lines. Investigation of a target surface morphology, after its irradiation by intense plasma streams, was performed by means of an optical microscope. The observations revealed that some amounts of the electrodes material (mainly copper) were deposited upon the irradiated sample surface. In all the cases, melted zones were observed upon the irradiated target surface, and in experiments performed at the highest charging voltage there were formed some cracks.
Źródło:
Nukleonika; 2016, 61, 2; 149-153
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new concept of fusion neutron monitoring for PF-1000 device
Autorzy:
Jednorog, S.
Laszynska, E.
Bienkowska, B.
Ziolkowski, A.
Paduch, M.
Szewczak, K.
Mikszuta, K.
Malinowski, K.
Bajdel, M.
Potrykus, P.
Powiązania:
https://bibliotekanauki.pl/articles/148394.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
PF-1000
neutron diagnostic
activation technique
Opis:
The power output of plasma experiments and fusion reactors is a crucial parameter. It is determined by neutron yields that are proportional and directly related to the fusion yield. The number of emitted neutrons should be known for safety reasons and for neutron budget management. The PF-1000 is the large plasma facility based on the plasma focus phenomenon. PF-1000 is operating in the Institute of Plasma Physics and Laser Microfusion in Warsaw. Neutron yield changes during subsequent pulses, which is immanent part of this type device and so it must be monitored in terms of neutron emission. The reference diagnostic intended for this purpose is the silver activation counter (SAC) used for many years. Our previous studies demonstrated the applicability of radio-yttrium for neutron yield measurements during the deuterium campaign on the PF-1000 facility. The obtained results were compared with data from silver activation counter and shown linear dependence but with some protuberances in local scale. Correlation between results for both neutron monitors was maintained. But the yttrium monitor registered the fast energy neutron that reached measurement apparatus directly from the plasma pinch. Based on the preliminary experiences, the yttrium monitor was designed to automatically register neutron-induced yttrium activity. The MCNP geometrical model of PF-1000 and yttrium monitor were both used for calculation of the activation coefficient for yttrium. The yttrium monitor has been established as the permanent diagnostic for monitoring fusion reactions in the PF-1000 device.
Źródło:
Nukleonika; 2017, 62, 1; 17-22
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in MJ plasma focus research at IPPLM
Autorzy:
Scholz, M.
Karpinski, L.
Krauz, V. I.
Kubeš, P.
Paduch, M.
Sadowski, M. J.
Powiązania:
https://bibliotekanauki.pl/articles/147514.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
PF-1000 facility
magnetic probes
interferometry
neutron yield scaling
Opis:
The results of studies of the plasma dynamics and neutron emission on a PF-1000 facility in the stage of pinch formation are presented. The measurements were performed using various modifications of the calibrated magnetic probes, 16 frame interferometry, silver activation counters and photomultiplier tube (PMT) neutron probes. The current measurements at a distance of 40 mm from the axis of the electrodes was measured. This dependence agrees well with the known scaling, Yn similar to I4. The evolution plasma density during pinch formation and a neutron emission were study.
Źródło:
Nukleonika; 2012, 57, 2; 183-188
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies