Tytuł:
Modelling and analysis of the quadrature-booster phase shifter with PWM AC bipolar matrix-reactance chopper and passive load
Autorzy:
Fedyczak, Z.
Jankowski, M.
Szcześniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/262819.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
AC power system
phase shifter
PWM AC matrix chopper
Opis:
This paper deals with a quadrature-booster phase shifter for power flow control and for transient stability improvement in AC transmission systems. The PWM AC bipolar matrix chopper (MC) is proposed for the control of the qudrature voltage component of the original voltage. There are presented in this paper both steady and transient state analyses of a transmission system with passive load based on averaged circuit models. Furthermore, simulation and experimental test results obtained in a three-phase 3 kVA laboratory model are also presented.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 83-93
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single parallel stubs as broadband microwave phase shifters
Autorzy:
Rutkowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/220484.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase shift
differential phase shift
microwave phase shifter
parallel stub
instantaneous frequency measurement
IFM
Opis:
Structures and characteristics of wideband small-size phase shifters made with the use of single parallel stubs are presented in this paper. The stubs can be short-circuited or open-circuited on termination. Such devices are well known, but are primarily used as components of filters or matching circuits. The novelty, then, comes from the establishment of simple, but helpful formulae, which enable to describe the insertion phase shift and differential phase shift of a line with short and open stubs connected in parallel. These equations can be very useful for designing complex microwave multi-ports. The results of simulations and measurements of the devices, which were designed and made, are shown herein. It was also proved that the presented device shave several usable operating frequency sub-bands, and that the differential phase shift values in the higher sub-bands are greater than those in the lower operating frequency ranges. Thanks to this, the described phase shifters can be used in more than one frequency sub-band. It was stated that in the conditions under analysis, larger phase shifts can be achieved using open-circuited stubs rather than short-circuited stubs. However, the phase shifters with shorted parallel stubs can operate in a wider frequency band.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 91-102
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power System State Estimation in Polar Coordinate System. Significance of Specific Information on Symmetrical Phase Shifter
Estymacja stanu systemu elektroenergetycznego w biegunowym układzie współrzędnych. Znaczenie specyficznej informacji o symetrycznym przesuwniku fazowym
Autorzy:
Wilkosz, K.
Okoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/952903.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
phase shifter
power system
state estimation
przesuwnik fazowy
system elektroenergetyczny
estymacja stanu
Opis:
Power system state estimation is a calculation procedure, which plays an essential role in computer systems in national control centres. Time of realization of the estimation calculation should be as short as possible. Accuracy of results of the estimation should be as large as possible. Sensitivity to errors burdening data utilized in the state estimation should be as small as possible. The paper considers the state estimation of a power system with a symmetrical phase shifter. That phase shifter is modelled using a general model of the phase shifter and using specific information on the symmetrical phase shifter. The paper describes original investigations of features of the power system state estimation in both the mentioned cases. Investigations show essential difference between features of the state-estimation for those cases.
Estymacja stanu systemu elektroenergetycznego jest procedurą obliczeniową, która odgrywa istotną rolę w systemach komputerowych dyspozycji mocy. Czas realizacji obliczeń estymacyjnych powinien być możliwie najkrótszy. Dokładność wyników estymacji powinna być możliwie największa. Wrażliwość na błędy obarczające dane wykorzystywane w procesie estymacji stanu powinna być możliwie najmniejsza. Przedmiotem tego artykułu jest estymacja stanu systemu elektroenergetycznego z symetrycznym przesuwnikiem fazowym – uwzględniono estymację stanu, w której zastosowano ogólny model przesuwnika fazowego oraz gdy pod uwagę bierze się także specyficzne informacje o przesuwniku. Artykuł zawiera wyniki oryginalnych badań obu tych przypadków – między nimi występują istotne różnice we właściwościach estymacji stanu.
Źródło:
Acta Energetica; 2018, 1; 88-94
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power system state estimation in rectangular coordinate system for different models of symmetrical phase shifter
Estymacja stanu systemu elektroenergetycznego w prostokątnym układzie współrzędnych dla różnych modeli symetrycznego przesuwnika fazowego
Autorzy:
Okoń, Tomasz
Wilkosz, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/266827.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
model
phase shifter
power system
state estimation
estymacja stanu
przesuwnik fazowy
system elektroenergetyczny
Opis:
The paper deals with State Estimation (SE) for a Power System (PS) with a Phase Shifter (PhS). Aim of the paper is to show results of investigations of impact of taking into consideration the specific information about the symmetrical PhS on features of PS SE. During investigations, WLS SE in the rectangular coordinate system is considered. For SE evaluation one utilizes such indices as: the number of iterations in SE, the index of the conditionality of the solved equations (condition number cond(G)) and the index of accuracy of SE (rate A). Using the IEEE 14-bus test system, investigations are made for representative cases of SE. The results show, that from the viewpoint of condition number cond(G), and rate A the state estimation with the use of the specific information on PhS is more profitable than SE using only the general model of PhS. Considering number of iterations in SE, the results of investigations are not so unambiguous.
Praca dotyczy estymacji stanu systemu elektroenergetycznego z przesuwnikiem fazowym. Jest kolejnym etapem badań wpływu obecności przesuwnika fazowego w systemie elektroenergetycznym na właściwości estymacji stanu. Celem pracy jest pokazanie wyników badań wpływu uwzględnienia specyficznej informacji o symetrycznym przesuwniku fazowym na właściwości estymacji stanu. Podczas badań brana jest pod uwagę estymacja stanu najmniejszych ważonych kwadratów w układzie współrzędnych prostokątnych. Dla potrzeb oceny estymacji stanu wykorzystywane są takie wskaźniki, jak: liczba iteracji w procesie obliczeniowym estymacji stanu, wskaźnik uwarunkowanie rozwiązywanych równań (wskaźnik uwarunkowania cond(G)) i wskaźnik dokładności estymacji stanu (wskaźnik A). W opisywanych badaniach wykorzystywany jest 14-węzłowy system testowy IEEE. Są one przeprowadzane dla reprezentatywnych przypadków estymacji stanu. Otrzymane wyniki pokazują, że z punktu widzenia uwarunkowanie rozwiązywanych równań i dokładności wyników estymacja stanu z uwzględnieniem specyficznej informacji o symetrycznym przesuwniku fazowym jest korzystniejsza aniżeli estymacja stanu uwzględniająca tylko ogólny model przesuwnika fazowego. Biorąc pod uwagę liczbę iteracji w estymacji stanu, wyniki badań nie są tak jednoznaczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 71-74
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wideband Nine-Port Reflectometer
Autorzy:
Odrobina, S.
Staszek, K.
Wincza, K.
Gruszczynski, S.
Powiązania:
https://bibliotekanauki.pl/articles/227101.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multiport measurement technique
reflectometer
reflection coefficient
measurement uncertainty
directional coupler
power divider
phase shifter
Opis:
The paper presents a wideband nine-port reflectometer realized as a cascade connection of six- and five-port reflectometers. It is shown that such a solution allows for a convenient adjustment of circuits’ parameters in order to provide significantly reduced measurement uncertainty with respect to other reported reflectometers. Simultaneously, the proposed network features a simple and flexible design. For the experimental verification, the proposed nine-port reflectometer has been manufactured and incorporated into the system intended for reflection coefficient measurements within the frequency range 2.5 - 3.5 GHz. The obtained results are in an excellent agreement with the values measured using a commercial VNA.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 1; 19-25
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studium wykorzystania przekształtnika macierzowego do budowy przesuwnika fazowego
The study of the application of matrix converter into phase shifting device
Autorzy:
Sieńko, T.
Szczepanik, J.
Powiązania:
https://bibliotekanauki.pl/articles/266964.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przekształtnik macierzowy
przesuwnik fazowy
FACTS
kontrola rozpływu mocy
matrix converter
phase shifter
power flow control
Opis:
W pracy wykonano analizę zastosowania wielofazowego Przekształtnika Macierzowego (PM) do budowy Przesuwnika Fazowego (PS). Analizę przeprowadzono przy pomocy technik symulacyjnych oraz pomiarów wykonanych na sześciofazowym modelu przekształtnika zbudowanym w laboratorium. Zaprezentowano trzy podstawowe schematy kontroli oraz ich związek z własnościami PM. Poza zdolnością przesuwnika fazowego do zmiany transferu mocy czynnej, interesujący jest wpływ urządzenia na transmisję mocy biernej co pokazano w artykule. Nowo pokazane właściwości PM pozwalają na budowę PS o większych możliwościach kontroli Systemu ElektroEnergetycznego (SEE) niż obecnie dostępne urządzenia. Możliwości różnych wariantów sterowania PM, oraz duża prędkość reakcji bazującego na nim PS będą niewątpliwie przydatne w kontroli stanów dynamicznych pracy SEE (stanach po zaburzeniowych) np. do szybkiej likwidacji kołysań generatorów czy regulacji rozpływu mocy.
Nowadays, in modern power systems there is a tendency to build more and more dispersed energy sources, to increase their transmission abilities and to increase their size. Parallel to these actions, the requirements regarding the quality of the delivered energy and system reliability are also increased. These changes required the new solutions to system control in both static and dynamic states of work to be implemented. The paper includes the analysis of the application of the multiphase Matrix Converter (MC) to the development of the phase shifting device. The analysis was performed not only on the basis of the simulation, but also on the basis of the waveforms obtained from the real life model constructed in the laboratory. The relationships between the device control algorithms and the properties of the built on their basis phase shifting device were thoroughly investigated. Some of the described properties of the MC are not only connected to its ability to influence active power flow in the power line, but also to its impact on reactive power transmission. For three developed control procedures, the reactive power flow control was investigated for MC working as a voltage source inverter on inductive load. The capabilities of alternative control procedures and short device reaction times can be useful not only for power flow control, but also during system dynamic states for example to fast dumping of the system oscillations. The research is the continuation of the previously published work, and its next step will include the solution to the MC commutation problems and the implementation of the MC based shifting device to the already build model of the multi-node power system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 93-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of control inhomogeneities of the dielectric between metal planes of microwave devices in phased array antennas
Badanie zakłóceń sterowania dielektryka między metalowymi płytkami w urządzeniach mikrofalowych antenowego szyku fazowanego
Autorzy:
Antonenko, A.
Geraimchuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/408681.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
micromechanical management
effective permittivity
dielectric heterogeneity
MEMS phase shifter
zarządzanie mikromechaniczne
przenikalność efektywna
heterogeniczność dielektryka
przesuwnik fazowy MEMS
Opis:
This article describes the phase shifters, based on micro-electromechanical elements connected to phased array antennas which operating in the frequency range 2–30 GHz. Estimations of controllability characteristics located between the metal dielectric planes, heterogeneity as an element of a micromechanical controlled microwave-devices. It is shown that when microdisplacements metal plane above the dielectric effective permittivity inhomogeneities it may vary from the values of the relative permittivity of the dielectric to one unit. Criteria required is small dielectric thickness or frequency at which the dielectric effect is not observed. The results can be used in the design of electromechanical devices managed using the MPN of piezoelectric and electrostrictive actuators or MEMS.
W artykule opisano przesuwniki fazowe na bazie elementów mikro-elektromechanicznych podłączonych do antenowego szyku fazowanego, pracującego w zakresie częstotliwości 2–30 GHz. Dokonano oszacowania cech sterowalności heterogenicznego dielektryka położonych pomiędzy metalowymi płaszczyznami, jako elementu mikromechanicznie sterowanego urządzenia mikrofalowego. Wykazano, że gdy przy mikro-przemieszczeniach metalowa płytki nad dielektrykiem niejednorodności przenikalności skutecznej mogą osiągać wartość 1. Wymagane kryteria to mała grubość dielektryka lub częstotliwość, dla której nie obserwuje się wpływu dielektryka. Wyniki mogą być stosowane przy konstrukcji urządzeń elektromechanicznych sterowanych za pomocą siłowników piezoelektrycznych, elektrostrykcyjnych lub MEMS.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 2; 8-11
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
A computer simulation of the phase shifter effects in the power system with wye connection of the series transformer
Autorzy:
Sarnicki, M.
Tarakan, B.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/268014.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej i biernej
regulacja kąta mocy
Phase Shifter
active and reactive power flow control
power angle
Opis:
Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
The following article describes the adjustment of the active and reactive power using the phase shifter. The winding of the booster transformer (series) is wye connected. The article shows the regulation of the active and reactive power for selected power system that is 10 bus system with phase shifter. The phase shifter also regulates flow of the active and reactive power simultaneously in the power system. The most common situation is when the both power regulation are independent and it is a better way to have control of both of them. The simultaneous regulation of the active and reactive power is possible by adding transformed voltage from different phases.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 167-169
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Transmission Capacities of Two Regulation Systems: Lateral and in-phase Control Transformers
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
Autorzy:
Sarnicki, M.
Zajczyk, R.
Tarakan, B.
Tarakan, K.
Powiązania:
https://bibliotekanauki.pl/articles/397201.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
przesuwnik fazowy
transformator dodawczy
regulacja przepływu mocy czynnej
regulacja przepływu mocy biernej
phase shifter
booster transformer
active load control
reactive load control
Opis:
This paper presents a comparison of regulation capabilities of lateral and in-phase control transformers in a selected node of a power system. Their regulation capabilities are presented, as well as cross-system exchange options.
W artykule przedstawiono porównanie możliwości regulacyjnych transformatorów z regulacją poprzeczną oraz wzdłużną w wybranym węźle systemu elektroenergetycznego. Zaprezentowano możliwości regulacyjne tych układów oraz możliwości kształtowania wymiany międzysystemowej.
Źródło:
Acta Energetica; 2016, 2; 186-190
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Use of a Matrix Converter for Building a Phase Shifter
Studium wykorzystania przekształtnika macierzowego do budowy przesuwnika fazowego
Autorzy:
Sieńko, T.
Szczepanik, J.
Powiązania:
https://bibliotekanauki.pl/articles/397609.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
przekształtnik macierzowy
przesuwnik fazowy
FACTS
kontrola rozpływu mocy
niezawodność systemu elektroenergetycznego
układy wielofazowe
matrix converter
phase shifter
power flow control
power system reliability
multi-phase system
Opis:
This paper presents an analysis of the application of a multi-phase matrix converter (PM) based device as a phase shifter (PS). The analysis was conducted using simulation techniques and measurements performed on a six-phase converter model built in a laboratory. Three basic control schemes and their relation to PM properties are presented. In addition to the phase shifter’s ability to change active power transfer, the device’s impact on reactive power transmission was also shown in the paper. Newly assessed PM properties permit the construction of a PS with higher power system control capacity than with currently available devices. Capabilities of various variants of PM control and fast rate of response of the PS based on it, will undoubtedly be useful in the control of dynamic states of the power system operation (postdisturbance states), e.g. for rapid elimination of generator oscillations or power flow adjustment. This study is an extension of the phase shifter concept presented in previous years, and the continuation assumes the construction of a shifter model for use in an already developed at Cracow University of Technology power system model.
W artykule została zaprezentowana analiza zastosowania wielofazowego przekształtnika macierzowego (PM) do budowy przesuwnika fazowego (PS). Analizę przeprowadzono za pomocą technik symulacyjnych oraz pomiarów wykonanych na sześciofazowym modelu przekształtnika zbudowanym w laboratorium. Zaprezentowano trzy podstawowe schematy kontroli oraz ich związek z własnościami PM. Poza zdolnością przesuwnika fazowego do zmiany transferu mocy czynnej interesujący jest wpływ urządzenia na transmisję mocy biernej, co ukazano w artykule. Nowo pokazane właściwości PM pozwalają na budowę PS o większych możliwościach kontroli systemu elektroenergetycznego (SEE) niż obecnie dostępne urządzenia. Możliwości różnych wariantów sterowania PM oraz duża prędkość reakcji bazującego na nim PS będą niewątpliwie przydatne w kontroli stanów dynamicznych pracy SEE (stanach pozaburzeniowych), np. do szybkiej likwidacji kołysań generatorów czy regulacji rozpływu mocy. Przedstawiona praca jest rozwinięciem koncepcji przesuwnika fazowego prezentowanego w poprzednich latach, a dalszy ciąg zakłada budowę modelu przesuwnika do zastosowania w wykonanym już modelu systemu elektroenergetycznego.
Źródło:
Acta Energetica; 2015, 2; 125-139
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
A comparison transmission capacity of two regulation transformers with quadrature regulation and in-phase regulation
Autorzy:
Sarnicki, M.
Zajczyk, R.
Tarakan, B.
Tarakan, K.
Powiązania:
https://bibliotekanauki.pl/articles/267801.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
regulacja przepływu mocy biernej
regulacja kąta mocy
transformator dodawczy
Phase Shifter
active power flow control
reactive power flow control
power angle
booster transformer connections
Opis:
Poniższy artykuł przedstawia możliwość regulacji mocy czynnej i biernej przepływającej pomiędzy podsystemami elektroenergetycznymi. Do regulacji przepływów wykorzystano przesuwnik fazowy i transformator dodający napięcie w fazie. Zilustrowana została regulacja mocy czynnej i biernej w badanym systemie elektroenergetycznym. Istotna jest zależność regulacji danej mocy od układu połączeń strony SN transformatora dodawczego (czy układ działa, jako przesuwnik czy jako transformator dodający napięcie w fazie).
This paper describes the regulation of active and reactive power between the subsystems in larger power system. To regulate the flow were used phase shifters and booster transformer which adds voltages in phase. The regulation of the active power and reactive in considered power system was shown in this article. Important is the way to regulate a certain kind of power (active or reactive), which strongly depends of MV side connections of booster transformer (whether the system acts as a phase shifter or as a transformer which adds the voltage in phase).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 89-91
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies