Tytuł:
Analysis of Water Consumption in the Campus of Warsaw University of Life Sciences in Years 2012-2016
Autorzy:
Wichowski, Piotr
Rutkowska, Gabriela
Kamiński, Norbert
Trach, Yuliia
Powiązania:
https://bibliotekanauki.pl/articles/124007.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water supply
daily peaking factor
hourly peaking factor
unit indicator
water consumption
Opis:
On the basis of the registered indications of the water meter, a study on the size and variability of water consumption on the WULS campus in the academic years 2012/16 is presented. The average specific water consumption at a time when classes are implemented amounted to 26.6 dm3 per student per day for full-time studies student and 19.7 dm3 per student per day for the student part-time studies. During the holiday season, the rates are lower at 18.4 and 11.8 dm3 per student per day, respectively. These ratios were determined without taking the water consumption in the dorms into account. The daily peaking factor amounted (Nd) to 1.36, while the hourly peaking factor (Nh), reached 1.71. Within the week cycle, the highest water consumption was observed in Tuesdays and the lowest – in Sundays. The average Tuesday demands are 40% higher than the Sunday demands. The water consumption peaks during the day occur between 11 a.m. and 1 p.m. as well as 11 p.m. and 1 a.m. The hourly structure of the water distribution in the WULS-SGGW campus is similar to the weekend structure of water distribution in multi-family residential buildings, with the exception of the later occurrence of the evening summit.
Źródło:
Journal of Ecological Engineering; 2019, 20, 5; 193-202
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Peaking factors of dry weather flows in Głogów combined sewage system
Współczynnik nierównomierności przepływu pogody bezdeszczowej w kanalizacji ogólnospławnej Głogowa
Autorzy:
Nowogoński, I.
Ogiołda, E.
Powiązania:
https://bibliotekanauki.pl/articles/971002.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
combined sewage system
dry weather flowrate
peaking factor
kanalizacja ogólnospławna
natężenie przepływu ścieków
współczynnik dobowej nierównomierności
Opis:
This paper presents the results of dry weather flowrate studies in inflow and outflow channels of overflow structure PB-1. The facility is located in P.Skargi Street in Głogów. Based on the results the average daily peaking factor of dry weather sewage outflow was estimated. Low efficiency of the algorithm allows the estimation of the flow when depth of the channel is less then 20 cm and when it is not possible to perform measurements with the ultrasound probe. Pointed to inadequate reconstruction of cross-sectional shape of the channel during device configuration as the cause of getting inconsistent results. The results of corrective calculations based on Manning's formula and typical crosssections of channels were presented. Obtained results confirm the possibility of significant differences obtained when the channel parameters are configured incorrectly. Confirmed the low quality of the built-in algorithm supporting measurements at low depths, mistakenly called by the device manufacturer “Manning’s formula method”.
W pracy przedstawiono wyniki badań natężenia przepływu ścieków pogody suchej w kanałach dopływowym i odpływowym z przelewu burzowego PB-1. Obiekt zlokalizowany jest przy ulicy P. Skargi w Głogowie. W oparciu o uzyskane wyniki oszacowano średni współczynnik dobowej nierównomierności odpływu ścieków pogody bezdeszczowej. Stwierdzono niską efektywność algorytmu umożliwiającego szacowanie natężenia przepływu w zakresie 0-20 cm napełnienia kanału, gdy nie jest możliwe wykonywanie pomiarów przy użyciu sondy ultradźwiekowej. Wskazano na mało dokładne odtworzenie przekroju kanału w czasie konfiguracji urządzeń jako przyczyny uzyskiwania sprzecznych wyników pomiarów. Zaprezentowano wyniki obliczeń korygujących wykonane w oparciu o wzór Manninga i typowe przekroje kanałów. Uzyskane rezultaty potwierdzają możliwość wystąpienia znaczących różnic uzyskiwanych przy nieprawidłowo skonfigurowanych parametrach kanału. Potwierdzono niską jakość wbudowanego algorytmu wspomagającego pomiary przy małych napełnieniach, błędnie nazywanego przez producenta urządzenia metodą Manninga.
Źródło:
Civil and Environmental Engineering Reports; 2012, 8; 29-37
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies