Tytuł:
Active - Passive: On Preconceptions of Testing
Autorzy:
Brzeziński, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/307856.pdf
Data publikacji:
2011
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
behavior
development
metrology
monitoring
passive testing
reactive systems
scientific method
Opis:
In telecommunications and software engineering, testing is normally understood to be essentially active: a tester is said to stimulate, control, and enforce. Passive testing does not fit this paradigm and thus remains the niche research subject, which bears on the scope and depth of the obtained results. It is argued that such limited understanding of testing is one of its many community-bound preconceptions. It may be acceptable in the current engineering approach to testing, but can and should be challenged in order to converge on the core concepts of the proposed science of testing ("testology"). This methodological work aims at establishing that there are no fundamental reasons for admitting the dominant role of the active element in testing. To show this, external (also extratechnical) areas are consulted for insight, direct observations, and metaphors. The troublesome distinction between (passive) testing and monitoring, as well as unclear relations between testing and measurements, are also addressed.
Źródło:
Journal of Telecommunications and Information Technology; 2011, 3; 63-73
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka lin nośnych dźwigu osobowego na podstawie obserwacji zmian magnetycznego pola rozproszenia
Diagnostics of traction ropes of a passenger lift based on observation of the magnetic leakage field
Autorzy:
Mazurek, P.
Roskosz, M.
Kwaśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/107782.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania nieniszczące
pasywna diagnostyka magnetyczna
dźwig osobowy
lina nośna
non-destructive testing
passive magnetic diagnostics
passenger lift
traction rope
Opis:
Liny stalowe są istotnymi elementami nośnymi urządzeń dźwigowych. Ich stan techniczny ma decydujący wpływ na ciągłą bezawaryjną pracę, a przede wszystkim na bezpieczeństwo ludzi korzystających z tych urządzeń. Bardzo ważnym zagadnieniem są metody badań i oceny stanu bezpieczeństwa pracujących lin stalowych. W artykule przedstawiono nowe możliwości wykorzystania w diagnostyce lin nośnych dźwigów osobowych, czujników magnetometrycznych zbudowanych na bazie materiałów amorficznych, bez zastosowania zewnętrznego pola magnetycznego. Wyjaśnione zostały ogólne podstawy fizyczne metody wykorzystującej zjawisko rozproszenia strumienia magnetycznego na obszarach materiału o odmiennej przenikalności magnetycznej.
Steel wire ropes are important load-bearing elements of lifting equipment. Their technical condition has a decisive impact on continuous trouble-free operation, and above all on the safety of people using these devices. A very important issue is the methods of testing and assessing the safety status of working steel wire ropes. The article presents new possibilities of using in the diagnostics of lifting ropes of passenger lifts, magnetometric sensors built on the basis of amorphous materials, without the use of an external magnetic field. The general physical basis of the method using the phenomenon of magnetic flux dispersion in areas of material with different magnetic permeability was explained.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 4; 34-37
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of effective passive vibration isolation of hydraulic valves
Autorzy:
Stosiak, Michał
Towarnicki, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2086943.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
passive vibration isolation
vibrations
hydraulic valve
modeling
testing
Opis:
The following paper describes the effect of the introduced vibration isolation on the operation of a hydraulic valve. The method of transmitting the external force to the valve control element and examples of vibration sources are presented. The balance of forces acting on the valve spool and the flow intensity in the tested hydraulic system are determined. The assumptions are simplified and discussed in detail. On their basis, numerical simulations have been carried out and verified by experimental tests. The paper ends with brief conclusions.
Źródło:
Journal of Theoretical and Applied Mechanics; 2022, 60, 1; 113--127
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody Magnetycznej Pamięci Metalu w diagnostyce obiektów technicznych
Use of Metal Magnetic Memory method in diagnostics of technical objects
Autorzy:
Dybała, J.
Nadulicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/234673.pdf
Data publikacji:
2015
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
metoda Magnetycznej Pamięci Metalu
MPM
pasywna diagnostyka magnetyczna
badania nieniszczące
Metal Magnetic Memory method
MMM
passive magnetic diagnostics
non-destructive testing
Opis:
W artykule zaprezentowano metodę Magnetycznej Pamięci Metalu (MPM) umożliwiającą wykonanie nieniszczących badań różnych obiektów technicznych, zarówno urządzeń mających znaczenie wojskowe, jak i wielkogabarytowych konstrukcji cywilnych. W pracy przedstawiono podstawy fizyczne stosowanej metody, wyniki przeprowadzonych badań oraz zalety i wady pasywnej diagnostyki magnetycznej. W artykule wykazano, że metoda MPM jest szybkim narzędziem pasywnej analizy obszarów, w których występowały bądź występują naprężenia wewnętrzne lub odkształcenia i można ją stosować, jako wstępną metodę diagnozowania obiektów technicznych. Zwrócono również uwagę na konieczność prowadzenia dalszych prac badawczych nad rozwojem zaprezentowanego podejścia diagnostycznego. Spodziewanym efektem tych prac będzie zwiększenie efektywności pasywnej diagnostyki magnetycznej umożliwiające jej zastosowanie w nowych obszarach aplikacyjnych.
The article shows the Metal Magnetic Memory (MMM) method that allows the execution of passive non-destructive testing of various technical objects, both military devices and civilian large structures. The paper presents a physical basis of used method, the results of conducted tests and advantages and disadvantages of passive magnetic diagnostics. The article shows that the MMM method is a fast tool for the passive analysis of areas where internal stresses or deformations exist and it can be used as a preliminary method for diagnosing technical objects. It is also highlighted the need for further research work on the development of the presented diagnostic approach. The expected result of these works will increase the efficiency of passive magnetic diagnostics enabling its use in new areas of application.
Źródło:
Problemy Techniki Uzbrojenia; 2015, 44, 133; 63-80
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies