Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "particulate pollution" wg kryterium: Temat


Tytuł:
‘Smoging kills’ - effects of air pollution on human respiratory system
Autorzy:
Grzywa-Celińska, A.
Krusiński, A.
Milanowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/2085457.pdf
Data publikacji:
2020
Wydawca:
Instytut Medycyny Wsi
Tematy:
air pollution
particulate matter
respiratory system
lung disease
Opis:
Atmospheric pollution suspended in humid air is popularly known as ‘smog’. It is composed of dust particles of different sizes, as well as non-metal oxides, organic compounds, and heavy metals. Exposure to harmful substances suspended in the air – apart from, for example – smoking cigarettes, one of the modifiable factors leading to the development of respiratory diseases. There are six types of substances present in the air that have a negative impact on public health and result in significant consequences: ozone, particulate matter (PM) of different diameters – PM2.5µ, PM2.5–10 µ, PM10 µ, nitrogen dioxide, sulphur dioxide, carbon monoxide and lead. Particular attention is given to small dust particles (PM10 and PM2.5) because they can penetrate into the lower respiratory tract. Apart from describing the composition of smog and sources of air pollution, the article also discusses the impact of atmospheric pollutants on both development and aggravation of the symptoms of such respiratory tract diseases as asthma, chronic obstructive pulmonary disease, respiratory infections and lung cancer. Some of legal measures applied in different countries aimed at reducing exposure to noxious air pollutants are reviewed. The authors believe that the increased focus on risks arising from inhaling toxic air pollution may be a first step for developing systemic solutions aimed at resolving or, at least, decreasing those risks.
Źródło:
Annals of Agricultural and Environmental Medicine; 2020, 27, 1; 1-5
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air quality assessment in the municipality of Wadowice
Autorzy:
Petryk, A.
Powiązania:
https://bibliotekanauki.pl/articles/101257.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
low emission
boilers
pollution
PM10 particulate matter
Opis:
The article presents an analysis of pro-ecological activities in the municipality of Wadowice in the field of air quality protection against the effects of low emission. Research conducted by the Provincial Inspectorate for Environmental Protection in Krakow indicated that in the town of Wadowice, the capital of the municipality, in the period from October till March, the permissible level of particulate matter (PM10) was exceeded on average approximately 16 times within one month. The municipality of Wadowice is one of the most polluted municipalities of the Małopolska voivodeship. The elaborated municipal Low-Emission Economy Plan, updated in 2017, is coherent with the climate and energy package and implements the guidelines of the new European Union 2020 strategy for economic and social development. Until 2015, the municipality had implemented the KAWKA program, which led to liquidation of 11 coal-fired boiler rooms and installation of 11 new boiler rooms. The continuation of the system in 2016 enabled the closure of further 31 coal-fired boiler rooms and the assembly of new boiler rooms and 10 solar panel installations in order to reduce emissions in the local fuel-fired heat source.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2018, IV/1; 909-921
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza rozkładu stężeń pyłu zawieszonego frakcji PM10, PM2,5 i PM1,0 na różnych wysokościach Mostu Gdańskiego
Analysis of Concentrations of Particulate Matter PM10, PM2,5 and PM1,0 at Different Heights of the Gdański Bridge
Autorzy:
Kuskowska, K.
Dmochowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/137094.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
pył zawieszony
liniowa emisja zanieczyszczeń
particulate matter
linear emission of pollution
Opis:
W artykule przedstawiono wyniki badań pyłów zawieszonych w miejskim powietrzu atmosferycznym, przeprowadzonych w obrębie Mostu Gdańskiego – jednego z ciągów komunikacyjnych łączących prawo- i lewobrzeżną Warszawę. Celem badań było dokonanie analizy wpływu wytypowanych liniowych źródeł zanieczyszczenia na jakość powietrza w tym rejonie Warszawy. Badania przeprowadzono na trzech wysokościach: na Wisłostradzie, przy torach tramwajowych Mostu Gdańskiego, około 4 m od jezdni Wisłostrady, oraz przy jezdni Mostu Gdańskiego, tj. na wysokości około 9 m od jezdni Wisłostrady. Otrzymane wyniki zaprezentowano w postaci wykresów i tabel, w których przedstawiono oddziaływanie transportu na jakość powietrza, a tym samym na poziom bezpieczeństwa ekologicznego w rejonie Mostu Gdańskiego.
The paper presents the results of the research concerning the dust from the linear sources of pollution emitted on the Gdanski Bridge – one of the bridges of Warsaw agglomeration. It is a route often frequented by drivers and place enjoyed by the citizens of Warsaw for recreational purposes. The aim of the study was to analyze the influence of linear sources of pollution on quality of air in the region. The study was performed in 3 heights: the Wislostrada, the tram tracks of the Gdanski bridge and the road of the Gdanski bridge. The results are presented in the graphs and tables showing the impact of transport on air quality and thereby on the level of ecological safety in this region.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 3, 59; 101-119
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of air quality assessment in Kielce in relation to the Covid-19 pandemic
Analiza oceny jakości powietrza w Kielcach w związku z pandemią Covid-19
Autorzy:
Metryka-Telka, Monika
Kowalik, Robert
Jurišević, Nebojša
Nešović, Aleksandar
Powiązania:
https://bibliotekanauki.pl/articles/2124789.pdf
Data publikacji:
2022
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
air quality
particulate matter
pollution monitoring
jakość powietrza
pył zawieszony
monitoring zanieczyszczeń
Opis:
Air pollution has a significant impact on citizens’ well-being and overall life quality. In this regard, regular air quality monitoring aims to keep pollution levels within prescribed limits and to identify the factors (winds, traffic, seasons, ambient temperature, air humidity, and so on) that influence pollution levels. To carry out a preliminary analysis of the air quality in Kielce, a specialist detector of PM2.5 and PM10 particles Steinberg 10030389 SBS-PM2.5 was used. Besides, the analysis referred to pollutants such as SO2; NO2; C6H6, which were provided from the Chief Inspectorate of Environmental Protection. Controlling the above mentioned pollutants for monthly and hourly averages of the selected time period in 2020 and 2021, taking into account the epidemiological situation (lockdown), graphs with the results were prepared. Then the analysis was carried out, with the preliminary assumption that the air quality is worse when the population functions normally than when it remains indoors, and that air quality is usually better at night than during the day.
Zanieczyszczenie powietrza ma znaczący wpływ na samopoczucie obywateli i ogólną jakość życia. W związku z tym regularne monitorowanie jakości powietrza ma na celu utrzymanie poziomu zanieczyszczeń w wyznaczonych granicach oraz identyfikację czynników (wiatry, ruch uliczny, pory roku, temperatura otoczenia, wilgotność powietrza itp.), które wpływają na poziom zanieczyszczeń. Do przeprowadzenia wstępnej analizy jakości powietrza w Kielcach wykorzystano specjalistyczny detektor cząstek stałych PM2,5 i PM10 Steinberg 10030389 SBS-PM2,5. Ponadto w analizie uwzględniono takie zanieczyszczenia jak SO2; NO2; C6H6, które zostały udostępnione przez Główny Inspektorat Ochrony Środowiska. Kontrolując ww. zanieczyszczenia dla średnich miesięcznych i godzinowych z wybranego okresu w latach 2020 i 2021, z uwzględnieniem sytuacji epidemiologicznej (blokada), sporządzono wykresy z wynikami. Następnie przeprowadzono analizę, przyjmując wstępne założenie, że jakość powietrza jest gorsza, gdy ludność funkcjonuje normalnie, niż gdy pozostaje w pomieszczeniach zamkniętych, oraz że jakość powietrza jest zwykle lepsza w nocy niż w ciągu dnia.
Źródło:
Structure and Environment; 2022, 14, 1; 24--32
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of low-cost particulate matter sensors for measurement of pollutants generated during 3D printing
Wykorzystanie niskobudżetowych czujników stężenia cząsteczekw celu pomiaru zanieczyszczeń powstających w trakcie pracy drukarek 3D
Autorzy:
Tatarczak, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/2070275.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
3D printing
particulate matter
pollution measurement
low cost sensor
druk 3D
pyły zawieszone
pomiar zanieczyszczeń
czujnik niskobudżetowy
Opis:
This work presents measurement results of pollutants generated during 3D printing. The measure of pollutants is the concentration of particulate matter with a diameter of up to 2.5 μm (PM2.5). Materials acrylonitrile-butadiene-styrene (ABS), polyactide (PLA) for a 3D printer and low-cost particulate matter concentration sensors PMS3003, PMS7003 were used in the research. Research results show that low-cost sensors can be useful for monitoring pollution during 3D printing in offices, laboratories or private homes.
Praca prezentuje wyniki pomiarów zanieczyszczeń generowanych podczas druku 3D. Miarą zanieczyszczeń jest koncentracja cząstek stałych materii o wymiarach do 2,5 μm (PM2,5). W badaniach zostały wykorzystane materiały aktonitryl-budatien-styren (ABS), poliaktyd (PLA) dla drukarki 3D iniskobudżetowe czujniki koncentracji cząstek stałych materii PMS3003, PMS7003. Wyniki badań pokazują, że niskobudżetowe czujniki mogą być przydatne do monitorowania zanieczyszczeń podczas druku 3D w biurach, laboratoriach czy domach.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 4; 75--77
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of X-ray fluorescence method for elemental analysis of PM2.5 fraction
Autorzy:
Samek, L.
Furman, L.
Kawik, T.
Welnogorska, K.
Powiązania:
https://bibliotekanauki.pl/articles/971541.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air pollution
energy dispersive X-ray fluorescence (EDXRF)
elemental analysis
particulate matter
Opis:
The scientific interest in air pollution comes from its influence on human health, the condition of cultural heritage and climate. The PM2.5 fraction (particles of a diameter of 2.5 mm or below), indirectly, has a significant impact on health which is associated with respiratory tract and blood vessel related diseases. However, not only the size, but also the content of the particles has a significant meaning. To determine the particulate matter contents, elemental analysis can be performed using numerous techniques, the most important of which is X-ray fluorescence. In this study, samples of PM2.5 fraction collected in Krakow, Poland were analyzed. The X-ray fluorescence method was used to perform elemental analysis. The gravimetric method was applied to determine the concentration of the PM2.5 fraction. Low detection limits of individual elements and precision of the X-ray fluorescence method were determined. The concentrations of the following elements: Cl, K, Ca, Cr, Mn, Fe, Cu, Zn, Br, Rb, Sr and Pb in the PM2.5 fraction samples collected in Krakow were evaluated. The homogeneity of the samples was also estimated. The concentrations of PM2.5 fraction collected in the summer of 2013 were in the range of 6–23 ng/m3. The concentrations of PM2.5 fraction collected in the winter of 2013 were in the range of 26–171 ng/m3. The precision of the method was found to be below 1% for elements with high concentration in the sample and 6–8 % for trace elements.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 621-626
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of integrated indoor environmental air quality parameters in selected church buildings of Faisalabad city: a statistical based comparative study
Autorzy:
Hussain, Zahid
Khan, Mohammad S.
Kundi, Kundi
Alaf, Kashif
Ullah, Yasir
Powiązania:
https://bibliotekanauki.pl/articles/35518580.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
indoor air quality
church buildings
particulate matter
public health
air pollution
Opis:
The objective of this study is to control the air quality parameters for a selected range of different particulate matters. A comprehensive experimental approach is established to regulate the quality of air about a selected range of different air pollutants being investigated in the indoor atmosphere of the church building. Relative humidity, temperature, carbon dioxide, particulate matter and radon were considered as the factors of air quality extents. For establishing the association among the selected parameters, the data were mathematically analyzed. The correlation coefficient confirmed a strong relationship between the indoor CO2 level and the number of public. A negative relationship between the indoor CO2 extent and indoor temperature confirmed that due to the increase in temperature the concentration of CO2 decreased as well. A solid adverse connection among indoor relative humidity and indoor air temperature showed that due to the increase in air temperature, the level of the relative humidity decreased. Some recommendations were proposed for the treatment of air quality in church buildings for human well-being.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 134-147
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the health risk associated with exposure to heavy metals present in particulate matter deposition in the Małopolska Province
Autorzy:
Wieczorek, Jerzy
Baran, Agnieszka
Pawlik, Ewa
Mądro, Izabela
Gąsienica, Anna
Wojtaszek, Iwona
Antonkiewicz, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1841750.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
air pollution
particulate matter deposition
heavy metals
health risk assessment
Opis:
The aim of the study was to investigate the content of trace elements in deposited particulate matter and to estimate the health risk to Kraków inhabitants, caused by the exposure to heavy metals in particulate matter deposition. The qualitative and quantitative assessments of selected heavy metals in deposited particulate matter have been carried out in the city of Kraków (Małopolska, southern Poland, 5 measuring points) for seven months, between February and September 2017. A comparative study was conducted at the same time in Małopolska (5 measuring points). The deposited particulate matter was collected gravitationally, using measurement plates covered with aluminum foil and paraffin jelly. The largest deposition of particulate matter was found in May and June. The highest amount of deposited particulate matter and metals present in it was determined in Kraków. The Hazard Quotient (HQ) evaluation for non-carcinogenic effect showed low risk for each metal. In the case of lead in particulate matter, the carcinogenic risk value did not reach 10−6 hence this risk is acceptable. The total carcinogenic risk for all routes of exposure to cadmium was higher, indicating the risk of cancer in children and adults, with children more exposed. However, the carcinogenic risk for cadmium was also acceptable. The study showed that the problem of poor air quality concerns not only the city of Kraków, but also the entire Małopolska region. Elevated metal concentrations in particulate matter indicate the need for monitoring it in the air.
Źródło:
Geology, Geophysics and Environment; 2021, 47, 2; 95-107
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atmospheric particulate matter in Tarnów City (Southern Poland) – short time investigation of a space-time variability in the winter of 2019
Autorzy:
Chyc, Marek
Klich, Mariusz
Klich, Sabina
Żelazo, Patrycja
Ciężadło, Agnieszka
Żeleźnik, Paweł
Partyńsk, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/93066.pdf
Data publikacji:
2019
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
airborne pollution
particulate matter
heating season
smog
zanieczyszczenie powietrza
cząstki stałe
sezon grzewczy
Opis:
Tarnów is a city where air pollution is a major problem during the wintertime. An acceptable level of PM2.5 and PM10 concentrations are exceeded very often. The main reason of this situation is individual housing and their heat system based on ineffective old units based on hard coal and sometimes even people use waste as a fuel. The city has two air quality monitoring stations and a private network for measurements of particulate matter. However, there is still a lack of information on air quality in some areas of the city. For obtaining full information on the air quality in Tarnów, readings from the monitoring station and field measurements were carried out. The obtained information allowed to determine which areas of the city are most exposed to the occurrence of smog in the heating season. So far, air quality measurements in Tarnów have not been conducted at the same time for so many collections.The most polluted air occurs in Krzyż District but air quality should be improved in all city. The best air quality has been observed for locations where heat is available from municipal heating plant e.g. Słoneczna Str. Presented research work shows that air quality in Tarnów City is very unhealthy because of particulate matter pollution. In the winter time the main problem is too high concentration of PM2.5, but also PM10 concentration. Those parameters are very frequently exceeded. The worst air quality occurs in the evenings (8 p.m.), but in the mornings (8 a. m.) air quality is highly polluted too. When air quality in Tarnów City is bad situation concerns all localisations. The similar situation is observed when air quality is good or acceptable. The main conclusion is that for locations where heat is available from heat plant is not generated individually by domestic sources, the situation is the most comfortable. Our investigation covered short period, but it is preliminary study and this important issue will be continued in the future.
Źródło:
Science, Technology and Innovation; 2019, 5, 2; 50-59
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Authors’ response (August 21, 2017) to the letter to the Editor concerning the paper “Mortality for chronic-degenerative diseases in Tuscany: Ecological study comparing neighboring areas with substantial difference in environmental pollution”
Autorzy:
Marabotti, Claudio
Piaggi, Paolo
Scarsi, Paolo
Venturini, Elio
Cecchi, Romina
Pingitore, Alessandro
Powiązania:
https://bibliotekanauki.pl/articles/2162009.pdf
Data publikacji:
2018-07-04
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
heavy metals
particulate matters
environmental pollution
mesothelioma
ischemic heart disease
neurologic degenerative diseases
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 4; 547-549
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Authors’ response (March 5, 2019) to the letter to the Editor concerning the paper “Impact of air pollution on depression and suicide”
Autorzy:
Gładka, Anna
Rymaszewska, Joanna
Zatoński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2161978.pdf
Data publikacji:
2019-06-14
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
air pollution
climate change
global warming
suicide
depression
particulate matter
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2019, 32, 3; 415-416
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zanieczyszczenia powietrza w Lublinie
Air Pollution Research in Lublin
Autorzy:
Kaszewski, Bogusław M.
Powiązania:
https://bibliotekanauki.pl/articles/2079564.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
particulate pollution
gaseous pollution
bioaerosols
air pollution
measurements
Lublin
zanieczyszczenia przez pył
zanieczyszczenia gazowe
bioaerozole
zanieczyszczenie powietrza
pomiary
Opis:
Na podstawie literatury przedstawiono stan badań zanieczyszczenia powietrza w Lublinie w ujęciu historycznym – od połowy XX w. Głównie ze względu na brak wypracowanych metod badań prace tego typu w XX w. były nieliczne. Postęp w badaniach zanieczyszczenia powietrza w Lublinie zaznaczył się dopiero na początku XXI w. W niniejszym opracowaniu wydzielono trzy zasadnicze grupy prac, dotyczące: 1) zanieczyszczeń przez pył nieorganiczny; 2) zanieczyszczeń gazowych; 3) bioaerozolu. Wśród czynników wpływających na jakość powietrza w Lublinie i na zróżnicowanie przestrzenne stężeń zanieczyszczeń istotne znaczenie ma nie tylko lokalna i napływowa emisja ze źródeł komunalno-bytowych (zachodząca w sezonie grzewczym) czy całoroczna emisja z tras komunikacyjnych (lokalnego i tranzytowego transportu samochodowego) i źródeł przemysłowych, lecz także występujące niekorzystne warunki meteorologiczne (np. w okresie zimy występująca czasem niewielka prędkość wiatru przy niskiej temperaturze), zróżnicowanie hipsometryczne miasta i gęstość zabudowy.
Based on the literature, the state of air pollution research in Lublin is presented in historical terms – from the mid-20th century. Due to the lack of developed research methods, there were not many publications of that type in the 20th century. Progress in the study of air pollution in Lublin did not appear until the beginning of the 21st century. In the paper, three main groups of works have been distinguished: 1) on inorganic particulate pollution; 2) on gaseous pollution; 3) on bioaerosols. Among the factors affecting air quality in Lublin and spatial differentiation of pollution concentrations are not only local and incoming emissions from municipal and domestic sources (occurring during the heating season) or all-year emissions from communication routes (local and transit road transport) and industrial sources, but also unfavorable meteorological conditions (e.g. occasional low wind speed and low temperature in winter), hypsometric diversity and building density of the city.
Źródło:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia; 2020, 75; 69-86
0137-1983
Pojawia się w:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlations between air pollutant concentrations in selected urban and rural areas in Poland
Autorzy:
Stelęgowski, Artur
Powiązania:
https://bibliotekanauki.pl/articles/106013.pdf
Data publikacji:
2019
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
air pollution
statistical analysis
nitrogen dioxide
particulate matter
zanieczyszczenie powietrza
analiza statystyczna
dwutlenek azotu
Opis:
Correlations between concentrations of selected air pollutants were analyzed in different areas in central Poland from 2012-2016. Three neighboring voivodeships (Lower Silesian, Lodz, and Masovian), were selected for which specific measurement locations were designated in urban and rural areas. The characteristics of the location of monitoring stations allowed to distinguish the following types of measurement stations: “urbantransport”, “urban-background", "suburban-background", "town-background", and "rural-background". Therefore, using the Pearson's linear correlation coefficient, it was possible to analyze the interrelations between the occurrence of air pollution in various types of areas. It was found that the coefficient changed along with the type of area. Moreover, it turned out that the coefficient decreased in each voivodeship along with a decrease in the population density of the analyzed areas. In addition, concentrations of various air pollutants in given areas were compared. Also, it was observed that the strongest correlations occur between the results of calculations from measurement stations located in the same province.
Źródło:
Acta Innovations; 2019, 31; 14-22
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of catalysts on emissions of pollutants from combustion processes of liquid fuels
Wpływ katalizatorów na emisję zanieczyszczeń z procesów spalania paliw ciekłych
Autorzy:
Bok, A.
Guziałowska-Tic, J.
Tic, W. J.
Powiązania:
https://bibliotekanauki.pl/articles/396265.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
air pollution
environmental protection
emission of pollutants
metallic catalyst
particulate matter
soot
zanieczyszczenia powietrza
ochrona środowiska
emisja zanieczyszczeń
katalizator
pyły
sadza
Opis:
The dynamic growth of the use of non-renewable fuels for energy purposes results in demand for catalysts to improve their combustion process. The paper describes catalysts used mainly in the processes of combustion of motor fuels and fuel oils. These catalysts make it possible to raise the efficiency of oxidation processes simultanously reducing the emission of pollutants. The key to success is the selection of catalyst compounds that will reduce harmful emissions of combustion products into the atmosphere. Catalysts are introduced into the combustion zone in form of solutions miscible with fuel or with air supplied to the combustion process. The following compounds soluble in fuel are inclused in the composition of the described catalysts: organometallic complexes, manganese compounds, salts originated from organic acids, ferrocen and its derivatives and sodium chloride and magnesium chloride responsible for burning the soot (chlorides). The priority is to minimize emissions of volatile organic compounds, nitrogen oxides, sulphur oxides, and carbon monoxide, as well as particulate matter.
Dynamiczny wzrost stosowania paliw nieodnawialnych dla celów energetycznych powoduje zapotrzebowanie na katalizatory poprawiające proces ich spalania. W pracy omówiono katalizatory stosowane głównie w procesach spalania paliw silnikowych i olejów opałowych. Katalizatory te pozwalają na podniesienie efektywności procesów utleniania powodując tym samym redukcję emisji zanieczyszczeń. Kluczem do sukcesu jest taki dobór składników katalizatora, który zapewni ograniczenie emisji szkodliwych produktów spalania do atmosfery. Katalizatory wprowadzane są do strefy spalania jako roztwory mieszające się z paliwem, lub do powietrza dostarczanego do procesu spalania. W skład omawianych katalizatorów wchodzą rozpuszczalne w paliwie: kompleksy metaloorganiczne, związki manganu, sole kwasów organicznych, ferrocen i jego pochodne oraz chlorek sodu i chlorek magnezu odpowiedzialne za spalanie sadzy. Priorytetem jest minimalizacja emisji lotnych związków organicznych, tlenków azotu, tlenków siarki i tlenku węgla oraz cząstek stałych.
Źródło:
Civil and Environmental Engineering Reports; 2014, 13; 5-17
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of development directions of low-carbon economy in the Nowy Targ commune
Autorzy:
Petryk, A.
Powiązania:
https://bibliotekanauki.pl/articles/100941.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
low emission
pollution
PM10 particulate matter
SO2
air quality
low-carbon economy
Opis:
The article presents an analysis of pro-ecological activities undertaken by the Commune Council of Nowy Targ in order to reduce low emission, and consequently to introduce a broadly understood low-carbon economy in this area. The commune aims at abandoning fossil fuels in favor of cleaner and safer methods of obtaining energy, which is to contribute to the reduction of PM10 and PM2.5 particulate matter emissions. In the nationwide arena, the commune was awarded in activities leading to the liquidation of low-emission as part of the competition for communes with a population up to 50,000 inhabitants and taking the second place in Poland in the „Gmina z Misją” ranking. The town of Nowy Targ was also the laureate of the fourth edition of the „#ekoLIDERZY2017 of the Małopolska Province” contest organized by the Provincial Fund for Environmental Protection and Water Management in Krakow (WFOŚiGW) and won the prize of PLN 20,000 in the category of „#ekoPRZEDSIĘWZIĘCIE” in the field of air protection and investments contributing to energy savings. In the commune, interventional and preventive inspections are carried out on an ongoing basis. In January 2017, the mayor appointed an advisory team for the analysis of the degree of implementation of actions in the field of air protection in the area of Nowy Targ.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2018, III/1; 673-685
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies