Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "partial discharges" wg kryterium: Temat


Tytuł:
A mobile system for measurements of partial discharges controlled by electroencephalographic waves
Autorzy:
Błachowicz, A.
Paszkiel, Sz.
Powiązania:
https://bibliotekanauki.pl/articles/384381.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
EEG
mobile robot
partial discharges
Opis:
The article presents the concepts of a mobile system for measurements of partial discharges controlled by brain waves. In order to describe that, a robot, which takes measurements of partial discharges, has been worked out. The discharges may occur in an isolator of electrical devices such as capacitors and transformers. What is more, a concept of a link between the robot and a human brain is described, in order to ensure a direct communication on the level of the human brain and the robot.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 3; 31-35
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aktualne możliwości i perspektywy zastosowania metody emisji akustycznej w diagnostyce układów izolacyjnych
Present possibilities and prospects of the acoustic method application in diagnostics of insulation systems
Autorzy:
Skubis, J.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/153254.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania niezupełne
system ekspercki
acoustic emission method
partial discharges
expert system
Opis:
W artykule zostały scharakteryzowane prowadzone obecnie przez autorów artykuły prace związane z doskonaleniem akustycznej metody pomiaru wyładowań elektrycznych, jakie mogą występować w układach izolacyjnych urządzeń elektroenergetycznych. Szczególną uwagę zwrócono na ekspercki system diagnostyczny wykorzystujący metodę emisji akustycznej do oceny stanu mierzonej izolacji transformatorów energetycznych.
The paper characterizes the research work on the improvement of the acoustic method of the measurements of electrical discharges that can occur in insulation systems of power appliances. The utmost attention was directed to the expert diagnostic system using the acoustic emission method for the evaluation of the condition of the power transformer insulation measured.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 10, 10; 44-45
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości detekcji wyładowań niezupełnych w aparaturze rozdzielczej średnich napięć w izolacji powietrznej metodą przejściowego napięcia doziemnego
Analysis and detection possibility of the partial discharges in air insulated medium voltage switchgear using transient earth voltage detection
Autorzy:
Buczko, R.
Sikora, A.
Powiązania:
https://bibliotekanauki.pl/articles/408523.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
wyładowania niezupełne
aparatura rozdzielcza
przejściowe napięcie doziemne
partial discharges
switchgear
transient earth voltage
Opis:
W nowoczesnej aparaturze rozdzielczej wykorzystuje się w coraz większym stopniu materiały polimerowe jako układy izolacyjne. Mimo swoich licznych zalet, wykazują one niekiedy ograniczoną wytrzymałość na wyładowania niezupełne. W artykule przedstawiono analizę możliwości wykorzystania nieinwazyjnej metody przejściowego napięcia doziemnego TEV do detekcji różnych form wyładowań niezupełnych w aparaturze rozdzielczej średnich napięć. Dzięki wykorzystaniu tej metody, diagnostyka odbywa się bez konieczności odstawiania urządzenia od systemu elektroenergetycznego. Uzyskane wyniki potwierdzają skuteczność metody.
Modern switchgear increasingly use polymeric materials as insulation. Despite its numerous advantages they have limited resistance to partial discharge corrosion in some cases. In this paper noninvasive methods Transient Erath Voltage (TEV) measurement is proposed to detect various forms of partial discharges in medium voltage switchgear. These method allows for non-invasive diagnostic without switch of the switchgear. Measurement results confirm the effectiveness of the proposed approach.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 3; 70-74
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości wykorzystania kamery do pomiaru promieniowania ultrafioletowego emitowanego przez wyładowania niezupełne generowane na modelu izolatora przepustowego
Analysis of camera application possibility for measurement of ultraviolet radiation emitted by partial discharges generated on a bushing isolator model
Autorzy:
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/153841.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne powierzchniowe
promieniowanie ultrafioletowe
izolator przepustowy
surface partial discharges
ultraviolet radiation
bushing isolator
Opis:
Tematyka artykułu dotyczy określenia możliwości i wskazania zakresu zastosowania w diagnostyce izolatorów liniowych i stacyjnych kamery rejestrującej promieniowanie ultrafioletowe. W artykule przedstawiono wyniki pomiarów promieniowania ultrafioletowego emitowanego przez wyładowania niezupełne powierzchniowe generowane na modelu izolatora przepustowego umieszczonego w powietrzu. W ramach przeprowadzonych badań dokonano analizy wpływu szeregu czynników metrologicznych na uzyskiwane wyniki.
The scope of this paper considers possibility determination and application area indication of a camera for ultraviolet radiation recor-ding in diagnosis of linear isolators. Measurement results of ultraviolet radiation emitted by surface partial discharges (SPDs) generated on a bushing isolator mounted in the air are presented in the paper. Recording was performed by use a professional UVollé camera by the firm OFIL which enables for ultraviolet radiation measurement in the range of 50 nm to 280 nm. The main aim of works, performed under laboratory conditions, was to estimate the influence of supply voltage value changes in the range of 0 to 0.98 Up (breakdown voltage) on the counting quantity of partial discharges occurring on the surface of the ceramic bushing isolator. Moreover, the measurements and analyses performed, enclosed the influence estimation of the duration time of voltage applied to high tension electrodes, on the optical phenomena progress connected with SPDs generation. In the scope of works executed also the influence analyses of the distance between electrodes as well parameters of camera applied (sensitivity, amplification and size of the counting window) on the achieved results were investigated. Additionally, a comparative analysis of measurements results achieved for two diameters of the metal electrode (refill) for bushing isolator model was performed.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 387-390
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wyładowań niezupełnych mierzonych metodą emisji akustycznej generowanych przy napięciu stałym i przemiennym
Comparative analysis of partial discharges measured using Acoustic Emission method and generated by DC and AC voltage
Autorzy:
Witkowski, P.
Boczar, T.
Kurtasz, P.
Powiązania:
https://bibliotekanauki.pl/articles/153187.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
metoda emisji akustycznej
analiza częstotliwościowa
analiza czasowo-częstotliwościowa
acoustic emission method
partial discharges
analysis of signals
Opis:
W artykule zostały opisane wyniki analizy porównawczej sygnałów emisji akustycznej (EA) zarejestrowanych podczas generacji wyładowań niezupełnych (WNZ) wewnątrz kadzi transformatorowej wypełnionej olejem izolacyjnym, przy zasilaniu napięciem stałym i przemiennym. Analizę uzyskanych wyników wykonano w dziedzinie częstotliwościowej przy zastosowaniu transformaty Fouriera (ang. FFT) oraz w dziedzinie czasowo - częstotliwościowej przy wykorzystaniu krótko czasowego przekształcenia Fouriera (ang. STFT). Głównym celem przeprowadzonych analiz porównawczych było określenie możliwości zastosowania napięcia stałego do wyzwalania układu pomiarowego i wyznaczania czasu propagacji sygnałów EA.
In this paper the results of the researches on acoustic emission (AE) signals, which arise during the partial discharges (PD) generation inside transformer tank filled with synthetic oil, were described. Authors analysed AE signal evoked by DC and AC voltage. The signals registered as a function of time were then transformed into frequency domain using FFT and STFT. The solid voltage was used to determine the propagation time.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 10, 10; 713-715
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza Zoptymalizowanego i Klasycznego Algorytmu Multikomparacyjnego w zastosowaniu do klasyfikacji sygnałów akustycznych generowanych przez wyładowania niezupełne
Comparative analysis of classic and optimised multi-comparational algorithm
Autorzy:
Kurtasz, P.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/157512.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
klasyfikator multikomparacyjny
klasyfikator binarny
wyładowania niezupełne
sygnały emisji akustycznej
defekty izolacji
multi-comparational classifier
binary classifier
partial discharges
acoustic emission signals
insulation defects
Opis:
W artykule określono zakres i scharakteryzowano możliwości zastosowania Zoptymalizowanego i Klasycznego Algorytmu Multikomparacyjnego do klasyfikacji sygnałów emisji akustycznej (EA) generowanej przez osiem podstawowych form wyładowań niezupełnych (WNZ), jakie mogą występować w izolacji papierowo-olejowej transformatorów elektroenergetycznych. Jest to nowa implementacja Klasycznego Algorytmu Multikomparacyjnego. Natomiast Zoptymalizowany Algorytm Multikomparacyjny został utworzony dla potrzeb klasyfikacji i w konsekwencji rozpoznawania sygnałów EA i jest wynikiem pracy Autorów. W artykule szczególną uwagę poświęcono omówieniu zasady działania zastosowanych algorytmów oraz wynikom uzyskiwanych przy ich użyciu skuteczności rozpoznawania podstawowych form WNZ.
Application of the optimised multi-comparational and classic multi-comparational algorithms to classification of acoustic emission signals generated by eight basic forms of partial discharges modelled in insulation oil is described in the paper. This is a new implementation of the classical multi-comparational algorithm. The idea of the algorithm was taken from [1]. The optimised multi-comparational algorithm was especially designed for needs of classification of the acoustic emission methods and is the result of research conducted by the authors of this paper. In Sections 2 and 3 the evaluated algorithms are characterised. Their logical structure is described in Section 4. Figs. 1 and 2 show the structure of both algorithms. In Section 5 the descriptor applied and the knowledge base adopted in the algorithms under study are described. The knowledge base is the result of earlier investigations performed by Sebastian Borucki and Andrzej Cichoń [3]. In Section 6 the binary classifiers applied are described; their structures are presented in Figs. 3 and 4. Section 7 contains the results of simulations performed. It was proved that both algorithms indicate high, over 90%, classification efficiency. The efficiency results are given in Tab.1, while its distributions are shown in Figs. 5 - 8. In Section 8 the evaluation results are summarised. Implementation of a time-frequency descriptor in the optimized multi-computational algorithm is proposed.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1110-1113
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wyników pomiarów diagnostycznych transformatora elektroenergetycznego uzyskanych metodą emisji akustycznej
Analysis of diagnostic measurement results of an electric power transformer obtained by the acoustic emission method
Autorzy:
Kurtasz, P.
Witkowski, P.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155759.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda emisji akustycznej
wyładowania niezupełne
olej elektroizolacyjny
transformator elektroenergetyczny
acoustic emission method
partial discharges
Opis:
W niniejszym artykule przedstawiono wyniki badań diagnostycznych układu izolacyjnego transformatora energetycznego z wykorzystaniem metody emisji akustycznej (EA), które przeprowadzono podczas jego normalnej eksploatacji w warunkach przemysłowych. Przedstawiono rezultaty analizy czasowej, częstotliwościowej, czasowo-częstotliwościowej i korelacyjnej zarejestrowanych sygnałów EA. Zostały wyznaczone i poddane analizie kolejno: przebieg czasowy (rys. 2), widma amplitudowe (rys. 3, 4, 5), spektrogram obliczony z wykorzystaniem krótkoczasowej transformaty Fouriera STFT (rys. 6) oraz funkcja autokowariancji (rys. 7). Badania diagnostyczne zostały przeprowadzone z uwagi na wysoki stan zagazowania oleju elektroizolacyjnego, na który wskazywały wyniki wykonanych dwukrotnie badań chromatograficznych. Ponadto badany transformator dwa razy, w krótkim okresie czasu został automatycznie wyłączony w wyniku zadziałania kolejno zabezpieczenia gazowo - przepływowego oraz zabezpieczenia różnicowo - prądowego. Dlatego istnało uzasadnione podejrzenie, że w kadzi analizowanego transformatora mogą występować wyładowania niezupełne (WNZ) o znaczącym poziomie i intensywności. Przeprowadzono analizę zarejestrowanych sygnałów akustycznych, której wyniki wskazują na brak obecności typowych form WNZ wewnątrz kadzi badanego transformatora. Jednakże charakter zarejestrowanych sygnałów akustycznych wskazuje na to, że ich źródłem jest zjawisko fizyczne. Jednocześnie wykazano, że nie są one typowymi sygnałami zakłóceniowymi generowanymi przez aparaturę pomiarową, pracujący transformator i otoczenie.
The paper presents the results of diagnostic investigations of an electric power transformer insulation system using the acoustic emission (AE) method. The investigations were carried out during the regular operation of the transformer under industrial conditions. The results of the time, frequency, time-frequency and correlative analyses of the AE signals registered are given. The waveform (Fig. 2), amplitude spectra (Figs. 3, 4, 5), the spectrogram calculated by using a short-time Fourier transform STFT (Fig. 6) and the autocovariance function (Fig. 7) were determined and analysed. The diagnostic tests were performed because of a bad physio-chemical condition of the electroinsulation oil shown by the results of the repeated chromatographic investigations. Moreover, the transformer under study was, in a short period of time, automatically switched off twice - by the gas - flow protection and then by the differential - current protection. Therefore it was justified to suspect that partial discharges (PDs) of a significant level and intensity might occur in the tub of the transformer analysed. The analysis of the acoustic signals registered was carried out, the results of which showed the lack of typical PD forms inside the tub of the transformer under study. However, the character of the acoustic signals registered indicated that their source was a physical phenomenon. At the same time it was proved that they were not typical interfering signals generated by a working transformer or environment.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 23-26
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of UV camera for PD detection on long rod HV insulator
Autorzy:
Urbaniec, I.
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/114242.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surface partial discharges
PD measurements
optical method
HV insulator diagnosis
Opis:
The aim of the research works, results of which are presented in this paper, was to determine the feasibility and to indicate the application scope of optical method in the diagnosis of high-voltage (HV) long rod insulators. Diagnosis of technical condition of HV insulators is critical, because the insulation system undergoes aging processes, which cause deterioration of the insulating properties. The measurements were performed during test under laboratory conditions using an UV camera. Corona partial discharges occurring on the long rod insulator were registered, while the supply voltage value was increased. The presented analyses consider dependencies of the supply voltage value on the count number of UV photons emitted by partial discharges occurring in long rod insulator made of porcelain.
Źródło:
Measurement Automation Monitoring; 2015, 61, 3; 64-67
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania eksperymentalne dotyczące wykorzystania metod stałoprądowych do diagnostyki izolacji maszyn elektrycznych
Experimental Tests Electrical Insulation of Electrical Machines Using Direct Current Measurement Methods
Autorzy:
Ławrowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368331.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
izolacja uzwojeń
diagnoza
metoda WMPS
współczynnik kondycji izolacji
wytrzymałość izolacji
wyładowań niezupełnych
Ramp Test
motor induction
winding insulation
diagnosis
method WMPS
diagnostic factor for insulation
insulation strength
partial discharges
Opis:
The paper will be presented the results of destructive isolation of high-power induction motors using different diagnostic methods on the same object. The purpose of these tests is to look for correlations that result in getting a good diagnosis.
W artykule zostaną przedstawione wyniki badań niszczących izolacji silników indukcyjnych dużych mocy z wykorzystaniem różnych metod diagnostycznych na tym samym obiekcie. Celem tych badań jest poszukiwanie wzajemnych korelacji, których skutkiem jest otrzymanie trafnej diagnozy.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 271-276
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie promieniowania ultrafioletowego generowanego przez wyładowania niezupełne powierzchniowe w powietrzu
Analysis of UV radiation generated by surface partial discharges
Autorzy:
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/275020.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
detekcja promieniowania ultrafioletowego (UV)
układ wysokonapięciowy
diagnostyka wyładowań niezupełnych
UV detection
high voltage devices
partial discharges diagnostics
Opis:
W artykule przedstawiono wyniki pomiarów intensywności względnej promieniowania ultrafioletowego (UV) zmierzone dla modelu izolatora szklanego umieszczonego w powietrzu. Promieniowanie generowane było przez wyładowania niezupełne. Badano wpływ wartości napięcia generacji wyładowań na intensywność emitowanego promieniowania optycznego. Ponadto analizowano wpływ odległości czujnika pomiarowego od elektrody, do której przyłożono wysokie napięcie.
The article presents measurement results of ultraviolet relative radiation intensity measured for a model glass insulator placed in the air. The radiation was generated by partial discharges. The effect of voltage on intensity-discharge generation of optical radiation is emitted. Furthermore, the influence of the distance from the electrode sensor, to which high voltage was applied on the measurement results.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 90-92
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of surface type partial discharges using electrical, acoustic emission and UHF methods
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/114691.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
PD measurements
UHF method
AE method
IEC60270
transformer fault diagnosis
Opis:
This paper presents research results related to measurements of partial discharges (PD), which may occur in oil insulation systems of electric power transformers. Three measuring methods were considered: electrical (apparent charge - IEC60270), acoustic emission (AE) and ultra-high frequency (UHF) method. Research works have been proceeded under laboratory condition. PD were generated using special apparatus and spark gap configuration for surface PD modeling. Measurements were performed simultaneously for each of the regarded methods and were repeated for selected supply voltage levels. The electrical and UHF methods measurements were made using MPD measuring system from Omicron. The AE method measurements were made using a piezoelectric transducer, which was installed on the outer transformer tank wall. Comparative analysis of signals gathered during research works was made. Possibilities of application of the three considered PD detection methods for electric power systems with oil insulation were proposed in the paper.
Źródło:
Measurement Automation Monitoring; 2015, 61, 1; 12-15
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charge dynamics of partial discharges explored applying a chopped sequence
Autorzy:
Florkowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2086894.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
chopped sequence
high voltage insulation
non-invasive diagnostics
wyładowania niezupełne
sekwencja posiekana
izolacja wysokiego napięcia
diagnostyka nieinwazyjna
Opis:
Diagnostic methodologies are of fundamental importance for operational strategies of electrical devices, both in the power grid and in industrial applications. This paper reports about a novel approach based on partial discharge analysis applied to high voltage electrical insulation. Especially dynamics of charges deposited by partial discharges is explored applying a chopped sequence. The applications refer to microvoids occurring inside solid insulating systems or at the interfaces, such as delaminations at the electrodes. The experiments were carried out on embedded voids having distinctive wall dielectric materials. The underlying physical phenomena of post discharge charge transport are analyzed. The assessment is performed using phase-resolved partial discharge patterns acquired applying a chopped sequence. The chopped partial discharge (CPD) method provides quantitative insight into post discharge charge decay processes due to deposited and accumulated charges fluctuations. The assessment indicator is based on comparing partial discharge inception angle between chopped sequence and continuous run. The experiments have shown that materials with distinctive surface conductivity revealed adequately different charge decay time dynamics. The detailed analysis yields time constant of walls charge decay for insulating paper equal to 12 ms and cross-linked polyethylene 407 ms. The CPD method may be further used to investigate streamer physics inside bounded cavities in the form of voids. The presented method provides a quantitative approach for charge non-invasive decay assessment and offers high potential in future diagnostics applications.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 5; e138817, 1--8
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z zastosowaniem metody emisji akustycznej
Diagnostics of power transformers using the acoustic emission method
Autorzy:
Sikorski, W.
Staniek, P.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/156561.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka transformatorów energetycznych
metoda emisji akustycznej
wyładowania niezupełne
power transformer diagnostics
acoustic emission method
partial discharges
Opis:
W artykule przedstawiono przykłady zastosowania metody emisji akustycznej do detekcji, identyfikacji i lokalizacji wyładowań niezupełnych (wnz) w transformatorach energetycznych. Dodatkowo omówiono takie kwestie jak: dobór optymalnych metod cyfrowego przetwarzania sygnałów emisji akustycznej, oprogramowanie wspomagające automatyczną identyfikację i analizę impulsów wnz oraz zakres aktualnie prowadzonych prac badawczych związanych z diagnostyką transformatorów przy wykorzystaniu metody emisji akustycznej.
The paper presents some examples of using the acoustic emission method for detection, identification and location of partial discharges (PD) in high voltage power transformers. Moreover, there are discussed such problems as: selection of optimal methods used for digital processing of acoustic emission signals, software for automatic identification and analysis of PD pulses and the realised research works dealing with power transformer diagnostics with the use of the acoustic emission method.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 11, 11; 760-762
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distribution and phase-resolved patterns of partial discharges form in non-uniform electric field in air
Rozkłady i obrazy fazowe form wyładowań niezupełnych w niejednorodnym polu elektrycznym w powietrzu
Autorzy:
Florkowska, B.
Zydroń, P.
Roehrich, J.
Powiązania:
https://bibliotekanauki.pl/articles/266690.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne w powietrzu
zakłócenia
obrazy fazowo-rozdzielcze wnz
partial discharges in air
disturbances
phase-resolved PD patterns
Opis:
Corona discharge is a form of partial discharges (PD) occurring at non-uniform electric field in air. This kind of discharges could be very useful in practical electrotechnology application, however in many cases corona discharges lead to serious technical problems. Corona discharge is a source of electro-magnetic interferences of wide frequency range, and e.g. during electrical power equipment diagnostic measurements at AC testing voltages it produces unneeded quasi-synchronic disturbances. Paper presents results of corona discharges investigations by means of partial discharge phase-resolved measurement method. Model needle-to-plane electrode systems were used during laboratory experiments as well defined corona discharge sources. PD forms and phase-resolved PD patterns were observed and analyzed for different setup and testing voltage parameters.
Wyładowania niezupełne w powietrzu w polu niejednorodnym są jedną z form wyładowań elektrycznych. Wyładowania te znajdują zastosowanie w pewnych aplikacjach technologicznych, jednak w wielu przypadkach powodują poważne problemy techniczne. Są źródłem zaburzeń elektromagnetycznych i podczas badań diagnostycznych urządzeń elektroenergetycznych napięciem przemiennym powodują powstawanie niepożądanych zakłóceń quasi-synchronicznych. Artykuł przedstawia wyniki badań wnz w polu niejednorodnym metodą pomiarów fazowo-rozdzielczych. Zastosowano układy modelowe elektrod typu ostrze-płaszczyzna. Rejestrowano obrazy fazoworozdzielcze dla różnych konfiguracji elektrod i wartości napięć probierczych. 5.0kV 6.0kV
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 51-54
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doskonalenie lokalizacji wyładowań niezupełnych metodą triangulacyjną z wykorzystaniem cewki Rogowskiego
Improvement the location of the partial discharges by the triangulation method with use the Rogowski coil
Autorzy:
Witkowski, P.
Boczar, T.
Kurtasz, P.
Powiązania:
https://bibliotekanauki.pl/articles/275022.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
metoda emisji akustycznej
wyładowanie niezupełne
cewka Rogowskiego
acoustic emission method
partial discharges
Rogowski coil
Opis:
W artykule zostały opisane wybrane metody i sposoby lokalizacji wyładowań niezupełnych (WNZ) występujących w transformatorach elektroenergetycznych, mierzonych zmodyfikowaną metodą emisji akustycznej. Autorzy skupili się na możliwościach udoskonalenia wykorzystywanej podczas pomiarów diagnostycznych metody triangulacyjnej przez wykorzystanie cewki Rogowskiego. Jednocześnie wskazano na możliwość zastosowania analizy czasowo-częstotliwościowej do ustalenia drogi propagacji fali akustycznej generowanej przez WNZ. Porównano charakterystyki czasowe i czasowo-częstotliwościowe sygnałów WNZ pokonujących jednorodne i niejednorodne drogi propagacji fali akustycznej.
In this paper, results of a study on acoustic emission (AE) signals, which arise during partial discharges (PDs) generation inside a transformer tank filled with synthetic oil, are described. It was made an effort to use the Rogowski coil to improve the localization of PDs method. Precisely the Rogowski coil is used to determine the propagation time. The signals are registered as a function of time.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 93-97
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies