Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "panes" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Gas interaction in insulating glass units in the case of elastic support of component glass panes
Autorzy:
Respondek, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/31342634.pdf
Data publikacji:
2022
Wydawca:
Politechnika Częstochowska
Tematy:
szkło w budownictwie
szyby zespolone
obciążenie klimatyczne
glass in building
insulating glass units
elastic supported panes
climatic loads
Opis:
Insulating glass units (IGUs), commonly used for filling windows and glass facades, have in their construction a tight gas-filled gap. This determines the good thermal insulation of the IGU, but at the same time makes it sensitive to climatic loads (changes in atmospheric pressure, temperature, wind load etc.). In the IGU gas interaction calculation models, these loads are usually simply supported at the connection of the component panes with the edge spacer. Under real conditions, another type of connection is possible, which was the subject of interest by several researchers. In this article, on the basis of the general theory of plates, an analytical model of the resultant load and deflection of IGUs under climatic loads is proposed, taking into account elastic support of the component panes. The computational examples illustrates the influence of connection stiffness on the resultant climatic load and deflection in IGUs.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2022, 11; 93-101
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantification of heat balance for windows with varying numbers of window panes and geographical exposure in the climate of the Wielkopolska region
Kwantyfikacja bilansu cieplnego okien o różnej liczbie szyb i orientacji geograficznej w warunkach klimatycznych Wielkopolski
Autorzy:
Błaszkiewicz, Z.
Rybacki, P.
Kneblewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/337209.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
window
heat balance
number of window panes
exposure
summer period
winter period
okna
bilans cieplny
liczba szyb
orientacja geograficzna
okres letni
okres zimowy
Opis:
The paper presents results of simulation tests for the heat balance of double, triple and quadruple glazed windows with eastern, southern, western and northern exposure, conducted for the climate conditions of the city of Poznań and the Wielkopolska region in response to the needs of eco power engineering. It was shown that in the summer period a greater number of window panes and a change in exposure from southern to eastern, western and northern result in a considerable reduction of heat balance for these windows. In the summer months from May to August heat balance of windows with eastern, southern and western exposure is comparable. The heat balance of windows with the northern exposure is much lower in each month of the summer period. In the winter period the highest and positive heat balance is recorded for windows with the southern exposure. Windows facing the other geographical directions have a comparable balance with values around zero. At all the exposures an increased number of window panes to a relatively limited extent improves heat balance, in general for the entire winter period and in its individual months.
Streszczenie Przedstawiono wyniki badań symulacyjnych bilansu cieplnego okien 2-, 3- i 4-szybowych ustawionych na wschód, południe, zachód i północ dla warunków klimatycznych Poznania i regionu Wielkopolski oczekiwane w ekoenergetyce. Wykazano, że w okresie letnim wzrost liczby szyb i zmiana ustawienia okien z południa na wschód, zachód i północ powodują znaczne zmniejszanie bilansu cieplnego okien. W miesiącach okresu letniego od maja do sierpnia bilans cieplny okien zorientowanych na wschód, południe i zachód jest zbliżony. Bilans okien skierowanych na północ jest znacznie niższy w każdym miesiącu okresu letniego. W okresie zimowym najwyższy i dodatni bilans cieplny mają okna skierowane na południe. Okna zorientowane na inne kierunki mają podobny bilans cieplny i oscylujący około zera. Przy wszystkich zorientowaniach geograficznych okien zwiększana liczba szyb dość mało polepsza bilans cieplny ogólnie w okresie zimowym i w poszczególnych jego miesiącach.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2018, 63, 4; 31-37
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stress and deflection in multi-glazed IGUs of various dimensions
Naprężenia i ugięcia w wielokomorowych szybach zespolonych o różnych wymiarach
Autorzy:
Respondek, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/2175040.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
glass in building
insulating glass units
climatic loads
stress and deflection of glass panes
szkło w budownictwie
szyby zespolone
obciążenia klimatyczne
naprężenie i ugięcie szyb
Opis:
In the structure of insulating glass units (IGUs) there are gas-filled gaps. Therefore, changes in atmospheric pressure and temperature, as well as the action of wind, result in a load on the component glass panes. However, the deflection of the panes connected with climatic loads results in an interaction of the gas closed in the gaps, which partially reduces climatic influences. The aim of this article is to analyze the influence of IGUs dimensions on the maximum stresses and deflections in the component glass panes, also in the context of the use of multi-glazed IGUs. Three typical loads were analyzed. It was found that in the case of wind load, with increasing dimensions of the IGUs, the stresses and deflections increase. On the other hand, in the case of loads related to pressure and temperature changes, in large-size IGUs, the gas interaction in the gaps is significant, which reduces the resultant load on the panes. It has been shown that there are critical IGU dimensions here for which the stress and deformation ratio are greatest. It was also found that increasing the number of gaps in IGUs results in a significant increase in the stress and deflection values due to climatic loads.
W konstrukcji szyb zespolonych (IGUs) istnieją szczelne szczeliny wypełnione gazem. W związku z tym zmiany ciśnienia atmosferycznego i temperatury, a także działanie wiatru skutkują obciążeniem składowych płyt szklanych. Jednak związane z obciążeniami klimatycznymi ugięcie płyt skutkuje interakcją gazu zamkniętego w szczelinach, która częściowo redukuje te wpływy klimatyczne. Celem artykułu jest analiza wpływu wymiarów IGUs na maksymalne naprężenia i ugięcia w szybach składowych, również w kontekście stosowania szyb wielokomorowych. Analizowano trzy typowe obciążenia. Stwierdzono, że w przypadku obciążenia wiatrem przy zwiększaniu wymiarów IGUs naprężenia i ugięcia rosną, natomiast w przypadku obciążeń związanych ze zmianami ciśnienia i temperatury w szybach wielkowymiarowych interakcja gazu w szczelinach jest znacząca, przez co maleje wypadkowe obciążenie szyb. Pokazano, że istnieją tutaj krytyczne wymiary IGUs, dla których naprężenie i wskaźnik deformacji są największe. Stwierdzono również, że zwiększenie liczby szczelin w IGUs skutkuje znaczącym zwiększeniem wartości naprężenia i ugięcia spowodowanego obciążeniami klimatycznymi.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2021, 27 (177); 213-218
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The identification of selected window energy parameters in winter and summer periods in the Greater Poland region
Identyfikacja wybranych parametrów energetycznych okien w okresie zimowym i letnim w regionie Wielkopolski
Autorzy:
Błaszkiewicz, Z.
Kneblewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/336284.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
windows
panes
window angle
gain
losses
heat balance
summer
winter
okna
liczba szyb
kąt ustawienia
zysk
straty
bilans cieplny
okres letni
okres zimowy
Opis:
The simulation research results of gains, losses and heat balance of two-, three- and four-paned windows positioned at 30, 60 and 90° angles relative to a surface for climatic conditions in Poznań and the Greater Poland region expected in the eco-power industry have been presented. It has been shown that in a summer period the increase in a number of panes and the angle of widows decreases high solar heat gain which determines similar alternations of heat balance at low losses. Particularly high window heat balance occurs from May to August due to high sun exposure at low heat losses. In winter, window heat balance is generally positive, apart from December, when it is minor and negative due to the lowest solar radiation at not the lowest outdoor temperature. Increasing a number of panes and a window angle does not change significantly window heat balance in a winter period.
Przedstawiono oczekiwane w ekoenergetyce wyniki badań symulacyjnych zysków, strat i bilansu cieplnego okien 2-, 3- i 4- szybowych ustawionych pod kątami 30, 60 i 90° względem podłoża, dla warunków klimatycznych Poznania i regionu Wielkopolski. Wykazano, że w okresie letnim wzrost liczby szyb i kąta ustawienia okien zmniejsza wysokie zyski ciepła, które przy niskich stratach determinują podobne zmiany bilansu cieplnego. Szczególnie wysoki bilans cieplny okien występuje w okresie od maja do sierpnia wskutek wysokiego nasłonecznienia przy niskich stratach ciepła. W okresie zimowym bilans cieplny okien jest ogólnie dodatni z wyjątkiem grudnia, kiedy jest nieduży i ujemny z powodu najniższej emisji promieniowania słonecznego przy nie najniższych temperaturach zewnętrznych. Zwiększanie liczby szyb i kąta ustawienia nie zmienia znacząco bilansu cieplnego okien w okresie zimowym.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2018, 63, 1; 8-12
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies