Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ozone" wg kryterium: Temat


Tytuł:
Characteristics of climate change in the years 1850-2100
Autorzy:
Staszewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/24201294.pdf
Data publikacji:
2023
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
climate change
greenhouse effect
circular net zero CO2 emissions
greenhouse gases
Putin's fuel crisis
ozone hole
zmiana klimatu
efekt cieplarniany
gazy cieplarniane
kryzys paliwowy Putina
dziura ozonowa
emisja zerowa
obieg zamknięty
Opis:
This article analyzes the basic factors influencing climate warming, as well as features characterizing the current picture of this phenomenon and presents possible directions of its development in the years 2022-2100. At the same time, it indicates that there is a possibility to stop the current trend of unfavorable changes and transform the climate into a more friendly phenomenon for people and their planet. First of all, anthropogenic CO2 emissions should be brought below net zero, and emissions of other greenhouse gases should be reduced as much as possible. This requires focusing on the development of a low-emission economy as well as circular economy and RES, as well as continuous improvement of the natural environment and a rational end to the war between Russia and Ukraine and the creation of sensible conditions for common security in the "global village".
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2023, 2; 1--6
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Efficiency of the Ozonator in the Process of Water Purification Based on the Corona Discharge
Autorzy:
Abdykadyrov, Askar
Marxuly, Sunggat
Mamadiyarov, Maxat
Smailov, Nunzhigit
Zhunusov, Kanat
Kuttybaeva, Ainur
Amanzholov, Arnay
Orazbekov, Asset
Powiązania:
https://bibliotekanauki.pl/articles/2202354.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
corona discharge
ozonator
sewage
electric current
high voltage
ozonometer
ozone concentration
Opis:
In this research paper, the problem of studying the effectiveness of ozone in the process of water treatment was considered. In the course of the scientific work, a review of domestic and foreign literature was conducted; its advantages and disadvantages were considered. The research paper presented the theoretical and practical methods of water purification with ozone. The main factors influencing the efficiency of the technology in the process of water purification were also considered. It was established that as a technological method of water purification, the efficiency of the ozonation process includes not only the cost of electricity, but also the efficiency of its mixing, ozone dissolution in treated water. In addition, special attention is paid to the final stage of mixing the ozone-air mixture with treated water. From the results obtained, it can be seen that after primary ozonation, the concentrations of chromium, oxidation of permanganate, iron, petroleum products, metal ions and other pollutants significantly decreased. During further water purification, organic and inorganic pollutants are removed in the future (completely or up to the requirements of the standard). However, calcium, magnesium, sulfates, chlorides, pH value, alkalinity and hardness practically do not change. The water quality after primary ozonation according to bacteriological indicators met the requirements of the standard.
Źródło:
Journal of Ecological Engineering; 2023, 24, 2; 140--151
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New environmentally friendly low-pressure refrigerants mini-channel
Autorzy:
Sikora, Malgorzata
Bohdal, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2204072.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refrigerants
global warming potential
ozone depletion potential
fluorinert liquid
hydrofluoroether
Opis:
Nowadays, in addition to the thermodynamic properties of refrigerants, their impact on the environment is of high significance. Hence, it is important to use refrigerants with the lowest possible values of ozone depletion potential and global warming potential indices in refrigeration, organic Rankine cycle (ORC), air conditioning, and heat pump systems. Natural refrigerants are the most environmentally friendly; unfortunately, they have less favourable thermodynamic properties. Currently, low-pressure refrigerants from the FC (fluorocarbons, fluorine liquids) and HFE (hydrofluoroether) groups are increasingly used. This paper presents the most important properties and applications of selected refrigerants from these groups and also reviews the literature on their use.
Źródło:
Archives of Thermodynamics; 2023, 44, 1; 89--104
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ozone detection based on an nitrogen oxide photoacoustic spectroscopy system and chemical reaction
Autorzy:
Jin, Huawei
Ji, Haitao
Wang, Haowei
Li, Shuo
Powiązania:
https://bibliotekanauki.pl/articles/28407430.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
photoacoustic spectroscopy
nitric oxide
ozone
differential detection
spektroskopia fotoakustyczna
tlenek azotu
ozon
dedekcja różnicowa
Opis:
Ozone is known as a “god-given purifying agent”, and its quantitative detection is of great significance. A low-cost photoacoustic spectroscopy (PAS) which is based on absorption at the low-power blue diode emitting at 403.65 nm has been used for nitrogen oxide (NO2) concentration measurements. According to the formula of nitric oxide (NO) reaction and ozone (O3) production of NO2and the differential detection method, a dual-channel PAS system for O3 detection is reported. The consistency of NO2detection with the dual-channel photoacoustic spectroscopy system is good by contrast. The coefficient of determination R2 can still reach 0.846. An intercomparison between the system and a cavity ring-down system (CRDS) was shown to verify the accuracy. The results showed a linear correction factor (R2) of 0.943 in a slope of 0.862±0.002, with an offset of (0.773±0.128) ppb. In addition, the measurement of 3using the dual-channel cavity photoacoustic spectroscopy technique was deployed. These observations indicate that 3concentrations can be effectively observed with the dual-channel PAS instrument.
Źródło:
Environment Protection Engineering; 2023, 49, 4; 73--87
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Ozonation Process for Shaping the Energy Properties of the Surface Layer of Polymer Construction Materials
Autorzy:
Kłonica, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2027827.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
surface layer
ozone
polymer material
surface free energy
Opis:
The properties of the surface layer of construction materials are very important for making adhesive bonds. The article presents the test results for surface free energy in PA6 polyamide subjected to surface layer modification using the ozonation process. To develop the surface geometrically, the samples were subjected to mechanical processing. The comparison of results demonstrated that ozonation is an efficient and eco-friendly method of modifying the surface layer. The article also presents the comparison results for measurements of selected surface roughness parameters.
Źródło:
Journal of Ecological Engineering; 2022, 23, 2; 212-219
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural Deformation of Tungsten Diselenide Nanostructures Induced by Ozone Oxidation and Investigation of Electronic Properties Change
Autorzy:
Kim, Eunjeong
Lee, Sangyoeb
Je, Yeonjin
Lee, Dong Park
Park, Sang Jun
Jeong, Sanghyun
Park, Joon Sik
Ahn, Byungmin
Park, Jun Hong
Powiązania:
https://bibliotekanauki.pl/articles/2176647.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tungsten diselenide
domain boundary
ozone oxidation
structural deformation
scanning tunneling microscopy
Opis:
Tungsten diselenide (WSe2) is one of the promising transition metal dichalcogenides (TMDs) for nanoelectronics and opto-electronics. To enhance and tune the electronic performance of TMDs, chemical functionalization via covalent and van der Waals approaches has been suggested. In the present report, the electric and structural transition of WSe2 oxidized by exposure to O3 is investigated using scanning tunneling microscopy. It is demonstrated that the exposure of WSe2/high-ordered pyrolytic graphite sample to O3 induces the formation of molecular adsorbates on the surface, which enables to increase in the density of states near the valence band edge, resulting from electric structural modification of domain boundaries via exposure of atomic O. According to the work function extracted by Kelvin probe force microscopy, monolayer WSe2 with the O3 exposure results in a gradual increase in work function as the exposure to O3. Therefore, the present report demonstrates the potential pathway for the chemical functionalization of TMDs to enhance the electric performance of TMDs devices.
Źródło:
Archives of Metallurgy and Materials; 2022, 67, 4; 1469--1473
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface Water Treatment Pilot using Micro Hydraulic Technology Combining Ozone and Activated Carbon
Pilotażowe oczyszczanie wód powierzchniowych z wykorzystaniem technologii mikrohydraulicznej łączącej ozon i węgiel aktywny
Autorzy:
Ngo, Phong
Nguyen, Linh
Powiązania:
https://bibliotekanauki.pl/articles/2172067.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
water treatment
micro hydraulic
activated carbon filtration
oxidation tower
ozone
uzdatnianie wody
mikrohydraulika
filtracja węglem aktywnym
wieża utleniająca
ozon
Opis:
The technological line proposed in the research process is a combination of Micro Hydraulic reaction technology combined with Ozone and activated carbon filtration. The processing line will be simulated by a test model with a capacity of 5 cubic meters per hour. Installation location at Nhi Thanh Water Supply Plant, Long An Province. The Pilot will operate in 9 different stages, in order to comprehensively evaluate the Pilot. The results of water quality analysis after the operation showed that the DO index increased from 3ppm to 7ppm, the pH remained stable at 7, turbidity (NTU) after treatment is always very low and averages at 0.01 NTU, Permanganate index after treatment is lower than 2 mg/l, average iron content is 0.05 mg/l, average manganese content is lower than 0.2 mg/l. Most of the water quality indicators are within the allowable limits according to QCVN 01-1: 2018/BYT, National technical regulation on Domestic Water Quality. This result will be compared with the quality of clean water after treatment at the Nhi Thanh water supply plant. Thereby, we can see the advantages and disadvantages when comparing the two water treatment technologies.
Zaproponowana w procesie badawczym linia technologiczna jest połączeniem technologii reakcji Micro Hydraulic połączonej z filtracją ozonem i węglem aktywnym. Linia technologiczna będzie symulowana przez model testowy o wydajności 5 metrów sześciennych na godzinę. Miejsce instalacji w zakładzie wodociągowym Nhi Thanh w prowincji Long An. Instalacja pilotażowa będzie działała w 9 różnych etapach. Wyniki analizy jakości wody po procesie wykazały, że wskaźnik DO wzrósł z 3 ppm do 7 ppm, pH utrzymywało się na stabilnym poziomie 7, mętność (NTU) po uzdatnianiu jest zawsze bardzo niska i średnio 0,01 NTU, wskaźnik nadmanganianowy po uzdatnianiu jest niższy niż 2 mg/l, średnia zawartość żelaza wynosi 0,05 mg/l, średnia zawartość manganu jest niższa niż 0,2 mg/l. Większość wskaźników jakości wody mieści się w dopuszczalnych granicach zgodnie z QCVN 01-1: 2018/BYT, krajowymi przepisami technicznymi dotyczącymi jakości wody użytkowej. Wynik ten został porównany z jakością czystej wody po uzdatnieniu w wodociągu Nhi Thanh. W ten sposób pokazano zalety i wady dwóch technologii uzdatniania wody.
Źródło:
Inżynieria Mineralna; 2022, 2; 115--120
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Ambient Air Quality of Mosul City/Iraq Via Air Quality Index
Autorzy:
Shihab, Abdulmuhsin S.
Powiązania:
https://bibliotekanauki.pl/articles/2027886.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
AQI
Mosul city
air quality
ozone
CO
SO₂
NO₂
PM₁₀
Opis:
The research aimed to assess air quality in Mosul city (Iraq) using air quality index (AQI). The data were collected at six monitoring sites using two stations, one fixed and the other is mobile type. The concentrations of $CO$, $NO_2$, $O_3$, $SO_2$ and $PM_{10}$ were measured. The daily AQI were calculated for each site and classified to AQI categories according to USEPA approach. The dominant AQI category at the public library site fluctuated between "Moderate" to "Unhealthy for Sensitive Groups". AQI undergoes seasonal variation with lower value at March. The results showed that PM10 is the main contributor for AQI determination in Mosul city with 93.8%. $CO$ has no contribution to Mosul AQI. $SO_2$, $O_3$ and $NO_2$ have little contribution to Mosul AQI with 0.8%, 2.7% and 2.7% respectively. The annual mean of AQI in the public library site/ Mosul city is 96 in the category "Moderate". The worst site was Mosul municipality (old location) with a dominant category "Unhealthy for Sensitive Groups".
Źródło:
Journal of Ecological Engineering; 2021, 22, 10; 241-250
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne, dostępne metody fizykalne wykorzystywane w leczeniu owrzodzeń podudzi - przegląd literaturowy
Modern, available physical methods used in the treatment of leg ulcers - a literature review
Autorzy:
Dziadek, Dominik
Sieroń, Dominik
Powiązania:
https://bibliotekanauki.pl/articles/2056437.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
metody fizykalne
miejscowa terapia tlenowa
tlen hiperbaryczny
ozonoterapia
ledoterapia
magnetoterapia
physical methods
local oxygen therapy
hyperbaric oxygen
ozone therapy
LLLT
magnetotherapy
Opis:
Problemem współczesnej medycyny pozostaje leczenie przewlekłych ran, zwłaszcza kończyn dolnych, będących najczęściej skutkiem choroby cukrzycowej, chorób naczyń żylnych i tętniczych oraz problemów z profilaktyką żywienia i niezdrowym trybem życia, co prowadzi w Polsce do ponad 10 000 amputacji rocznie. Amputacja kończyn znacząco obniża jakość życia pacjenta oraz zwiększa koszty leczenia. Obecnie poszukuje się środków, które skutecznie leczą niegojące się rany podudzi. Przedmiotem opracowania jest omówienie nowoczesnych metod fizykalnych w terapii medycznej oraz ocena ich skuteczności na podstawie analizy dostępnej literatury. Pod uwagę wzięto opracowania historyczne dotyczące podstawowych praw fizykobiomedycznych oraz opracowania z ostatnich 10 lat, w których omawiane są poszczególne aplikacje terapeutyczne. W artykule tym znajdują się podstawowe informacje na temat parametrów pracy urządzeń biomedycznych, w których stosuje się: światłoterapię, magnetoterapię, tlenoterapię oraz ozonoterapię. Omawiana literatura wskazuje, że w obliczu systematycznie zwiększającego się problemu choroby cukrzycowej, a co za tym idzie wzrostu liczby wystąpienia stopy cukrzycowej, terapie fizykalne realizowane przez urządzenia nowego typu mogą być skuteczną formą wspierającą konwencjonalną terapię i mogą odegrać kluczowe znaczenie przy ratowaniu kończyn przed amputacją.
Problem of modern medicine remains the treatment of chronic wounds, especially the lower limbs, which are most often the result of diabetic disease, venous and arterial disease as well as nutritional deficiencies and unhealthy lifestyle, which leads to over 10,000 amputations per year in Poland. Limb amputation significantly reduces the patients’ quality of life and increases treatment costs. At present, effective treatments of non-healing lower limb wounds are still being sought. The subject of the study is to discuss modern physical methods in medical therapy and assess their effectiveness on the basis of analysis of available literature. Historical studies on basic physiobiomedical laws and studies from the last 10 years in which individual therapeutic applications are discussed were taken into account. This article contains basic information on the parameters of biomedical devices that use: light therapy, magnetotherapy, oxygen therapy and ozone therapy. The literature discussed indicates that in the face of the systematically increasing problem of diabetic disease, and thus the increase in the number of diabetic foot occurrences, physical therapies implemented by new type devices may be an effective form supporting conventional therapy and may play a key role in saving limbs from amputation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2021, 1, 125; 101--106
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ozone disinfection of community pharmacies during the COVID-19 pandemic as a possible preventive measure for infection spread
Autorzy:
Merks, Piotr
Religioni, Urszula
Bilmin, Krzysztof
Bogusz, Joanna
Juszczyk, Grzegorz
Barańska, Agnieszka
Kuthan, Robert
Drelich, Ewelina
Jakubowska, Marta
Świeczkowski, Damian
Białoszewski, Artur
Jaguszewski, Miłosz
Panford-Quainoo, Edwin
Vaillancourt, Regis
Białoszewski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2087514.pdf
Data publikacji:
2021-11-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
coronavirus
pandemic
ozone
disinfection
pharmacist
pharmacy
Opis:
The COVID-19 pandemic is currently one of the major global health and economic challenges. An efficient method for reducing the transmission of the virus is a still unmet medical need. Existing experimental data have shown that coronavirus survival is negatively impacted by ozone, high temperature, and low humidity. Therefore, it is feasible to use area ozonation in pharmacies – the front line of the healthcare system. Nevertheless, further work is needed to evaluate the effectiveness of ozone disinfection to reduce the transmission of this virus in pharmacies, hospitals, and other public environments. Med Pr. 2021;72(5):529–34
Źródło:
Medycyna Pracy; 2021, 72, 5; 529-534
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Ozonation, Coagulation and Adsorption on Natural Organic Matter Removal
Autorzy:
Dąbrowska, Lidia
Powiązania:
https://bibliotekanauki.pl/articles/1955547.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ozone
activated carbon
polyaluminium chloride
trihalomethane precursor
Opis:
For the treatment of surface water, the coagulation process was used with highly alkaline polyaluminium chloride PAX-XL19F and coagulation supported by ozonation and adsorption on powdered activated carbon CWZ-30 for reducing the level of surface water pollution with organic substances. In addition to the typical indices used to assess the content of organic compounds (total organic carbon TOC, oxidisability OXI, ultraviolet absorbance UV254), the study also evaluated colour, turbidity, and the potential of trihalomethanes formation THM-PF. Reduction in the content of TOC in water after coagulation ranged from 22 to 24%, OXI in the range of 34-36%, and UV254 absorbance from 52-55%. The turbidity and colour of the water was reduced by 70-73% and 56-60%, respectively. The use of preliminary ozonation and activated carbon-assisted coagulation increased the efficiency of water treatment. Changes in the values of TOC, OXI, UV254 absorbance, turbidity and colour were 28-33%, 45-46%, 69-73%, 72-79% and 89-100%, respectively. In the water purified by coagulation and then chlorinated, THM-PF was 37-38% lower than in untreated surface water. The use of additional pre-ozonation and activated carbon during coagulation increased the reduction of THM-PF by 9-12%.
Źródło:
Journal of Ecological Engineering; 2021, 22, 9; 216-223
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ dezynfekcji pomieszczeń ozonem na skuteczność ujawniania śladów daktyloskopijnych na powierzchni papieru metodą DFO w dobie pandemii SARS-CoV-2
The effect of ozone disinfection of rooms on the efficacy of revealing dactyloscopic traces on the surface of the paper using the DFO method during the SARS-CoV-2 pandemic
Autorzy:
Szczepański, Tomasz
Więckiewicz, Urszula
Konior, Barbara
Pucułek, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/1052547.pdf
Data publikacji:
2021-04-29
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
ślady linii papilarnych
daktyloskopia
dfo
ozon
papier
dezynfekcja
kryminalistyka
fingerprints
dactyloscopy
ozone
paper
disinfection
forensics
Opis:
Obserwowany od początku 2020 r. gwałtowny wzrost zachorowań na COVID-19 wywołanych zakażeniem koronawirusem SARS-CoV-2 (ang. Severe acute respiratory syndrome coronavirus 2) oraz ogłoszenie w marcu ubiegłego roku przez WHO stanu pandemii spowodowały zwiększenie zainteresowania technikami dezynfekcji niszczącymi przede wszystkim wirusy. Jedną z  takich metod jest ozonowanie. Niebezpieczeństwo zakażenia może wynikać z  kontaktu materiału, np. przesyłki pocztowej, z  nosicielem wirusa, szczególnie asymptomatycznym. Możliwe jest także intencjonalne skierowanie skażonego listu w  celu wywołania zagrożenia. Wymusza to wypracowanie skutecznej metody dezynfekcji, która zapewni względne bezpieczeństwo odbiorcom. Jednocześnie aby umożliwić ewentualną identyfikację nadawcy, w tym m.in. na podstawie śladów daktyloskopijnych, niezwykle istotne jest stosowanie takich technik dezynfekcji, które nie zniszczą śladów kryminalistycznych. Ponadto, z punktu widzenia czynności wykrywczych, jest ważne ustalenie, czy ślady daktyloskopijne pozostawione na podłożu papierowym (np. list, koperta, dokument) poddanym ozonowaniu nie ulegają zniszczeniu.
The article presents the results of research aimed at determining the extent to which ozone used for disinfecting rooms affects the possibility of developing fingerprints on paper using the DFO method. A sudden increase in COVID-19 cases has placed the focus on disinfection techniques for user safety. It is also becoming important to ensure the safety of parcels addressed to various recipients by inactivating pathogens, while maintaining the possibility of examination that can identify the sender, which is important from the point of view of forensics. Ozonation is a disinfection technique that has been used for many years, in particular for water treatment or in the food industry. The experiments were carried out in rooms with a cubature of approx. 20 m3 using an ozone generator available on the market. The obtained ozone gas concentration did not exceed 10 ppm. The conducted research confirmed that the traces of fingerprints left on xerographic paper placed in a room subjected to ozonation in a concentration not exceeding 10 ppm are not damaged and can be successfully developed with the DFO method.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2021, 13, 24; 277-293
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical vapour compression refrigeration system: review part 1: environment challenge
Autorzy:
Mahmood, Raid Ahmed
Ali, Omar M.
Noor, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1839710.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
czynnik chłodniczy
układ chłodniczy
warstwa ozonowa
alternative refrigerant
mixture refrigerants
vapour compression refrigeration system
ozone depletion potential
global worming potential
R507A refrigerant
natural refrigerant
R-718 (water/steam)
Opis:
In Australia and others developed countries, concerns about global warming have increased, and these concerns influence the use of refrigerants as working fluids in mechanical vapour compression refrigeration systems. One of the most important aspects of refrigerant selection is to reduce its impact on the environment and the ozone layer. This paper provides a comprehensive review of various theoretical and experimental studies which have been carried out on air conditioning and refrigeration applications to investigate the effect of refrigerants on the environment. The analysis in this paper reveals that alternative refrigerants are the most suitable working fluids that can be used in refrigeration systems to meet the needs of the environment. This study also suggests that natural types of refrigerants such as water, carbon dioxide, and hydrocarbon will play a significant role in protecting the environment and providing alternative friendly refrigerants to be used in refrigeration and air conditioning systems.
Źródło:
International Journal of Applied Mechanics and Engineering; 2020, 25, 4; 130-147
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan warstwy ozonowej nad Polską w okresie 1979-2018
Ozone Layer Over Poland in the Period 1979-2018
Autorzy:
Krzyścin, Janusz
Rajewska-Więch, Bonawentura
Borkowski, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1818535.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwa Geofizyczne
Tematy:
warstwa ozonowa
trend
odbudowa warstwy ozonowej
ozone layer
ozone recovery
Opis:
W pracy analizowano zawartość ozonu w całej kolumnie atmosfery i wybranych warstwach (troposfera/dolna stratosfera, środkowa stratosfera i wysoka stratosfera) zmierzone spektrofotometrem Dobsona w Centralnym Obserwatorium Geofizycznym Instytutu Geofizyki Polskiej Akademii Nauk w Belsku (20,78°E, 51,84°N) w latach 1963-2018. Stwierdzono zatrzymanie spadkowej tendencji w połowie lat 90. ubiegłego wieku, a następnie niewielki wzrost zawartości ozonu. W ostatnich kilkunastu latach w analizowanych warstwach obserwuje się nieoczekiwane beztrendowe oscylacje ozonu w miejsce spodziewanego stopniowego wzrostu w związku ze zmniejszającą się koncentracją w stratosferze substancji niszczących warstwę ozonową w wyniku funkcjonowania Protokołu Montrealskiego z 1987 r. o ochronie warstwy ozonowej. Wyznaczono długookresowe zmiany w kolumnowej zawartości ozonu nad wybranymi obszarami na półkuli północnej, stosując homogenizowane satelitarne dane ozonowe z bazy danych Multi-Sensor Reanalysis version 2. Przedmiotem analizy były sezonowe i całoroczne średnie w okresie 1979-2018 wyznaczone dla następujących obszarów: otoczenie Belska, Polska, Europa Środkowa, Europa, pas średnich (30-60°N) i wysokich (60-90°N) szerokości geograficznych, oraz tropiki (0°-30°N). Antropogeniczny trend obliczono, stosując model regresji wieloskładnikowej, odfiltrowując z serii czasowych oscylacje związane z naturalnymi procesami dynamicznymi w atmosferze. Do połowy lat 90. ubiegłego wieku dominowały ubytki w warstwie ozonowej w tempie kilku procent na 10 lat (największe wiosną w Polsce i Europie Środkowej ~5% na 10 lat, najmniejsze w tropikach ~0,5% na 10 lat). Naprawę warstwy ozonowej po 1996 roku, w tempie ~4-5% na 10 lat, najwyraźniej widać zimą w Polsce i w Europie Środkowej. Odpowiadające wzrostowe trendy w całej Europie i w średnich szerokościach geograficznych były mniejsze o 1-2 punkty procentowe. W pozostałych sezonach i w danych całorocznych trend był znacznie mniejszy (~1-2% na 10 lat) lub nieistotny statystycznie.
Ground-based measurements of ozone by the Dobson spectrophotometer in the Central Geophysical Observatory of the Institute of Geophysics of the Polish Academy of Sciences at Belsk (20.78°E, 51.84°N) are analysed for the period 1963-2018. Long term variability of the total column ozone and the ozone content in the selected layers (troposphere/lower stratosphere, mid- and upper stratosphere) are discussed focusing on the ozone recovery in recent years. The trend overturning is found around 1996. However, an unexpected trendless pattern of the long-term ozone variability has been found since the beginning of the 2000s instead of the envisaged continuous upward tendency due to the decreasing concentration of the ozone-depleting substances in the stratosphere as a result of the 1987 Montreal Protocol on the protection of the ozone layer. The long-term variability of the total column ozone over selected areas in the Northern Hemisphere are assessed using homogenized satellite data from the Multi-Sensor Reanalysis version 2 database. The seasonal and the yearly means for the period 1978-2018 are considered for the following regions: Belsk, Poland, central Europe, Europe, middle latitudes (30°N-60°N), high latitudes (60°N-90°N), and the tropics (0°-30°N). The anthropogenic trend is determined by multiple regression model after filtering out oscillations related to the known dynamic processes in the atmosphere. In all regions, a decline of the total column ozone is found in the 1980s and up to mid-1990s. The largest decline appears in spring in Poland and central Europe (~5% per 10 yr.), and the smallest over the tropics (-0.5% per 10 yr.). After 1996, the recovery is clearly seen (4-5% per 10 yr.) during winter in Poland and in central Europe. These estimates are about 1-2 percentage point higher than the corresponding increasing trends in Europe and in the middle latitudes. In the remaining seasonal and year-round time series, the trends are much smaller (1-2% per 10 yr.) or statistically insignificant.
Źródło:
Przegląd Geofizyczny; 2020, 3-4; 103--121
0033-2135
Pojawia się w:
Przegląd Geofizyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atmospheric Air Pollution with Tropospheric Ozone on the Example of Selected Rural Villages of the Lubelskie Region
Autorzy:
Zuśka, Zbigniew
Baranowska, Alicja
Skowera, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/123989.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
tropospheric ozone
air pollution
acceptable level
Opis:
In excessive concentrations, the tropospheric ozone (the so-called trioxygen O3) constitutes a serious threat to the ecosystems of our planet. It is a threat to the health and life of people. In plants, it contributes to disruption of the most important biochemical processes. The purpose of this study was to assess atmospheric air pollution with tropospheric ozone in selected rural villages of the Lubelskie region in the years 2015–2017. Assessment of air quality in the Lubelskie region in terms of the content of tropospheric ozone, which is significant for the protection of plants and human health, was carried out in accordance with the Regulation of the Minister of Environment of 24 August 2012 on the levels of certain substances in the air, as well as more restrictive guidelines of the World Health Organization. The research used the hourly values of automatic measurements of the tropospheric ozone immission in the years 2015–2017. The data originated from three measurement stations, which function as part of the Air Quality Monitoring System, in three rural communes located in the north-western, central and southern part of the Lubelskie region. As a result of implemented research, no tropospheric ozone concentrations exceeding the threshold values, at which the public should be informed about the risk of exceeding the alarm level, were noted. The highest mean tropospheric ozone immission was recorded during the calendar summer and calendar spring, while the lowest was recorded during the calendar winter and autumn. In terms of human health protection, the largest exceedances of the maximum mean 8-hour value of tropospheric ozone were recorded during the calendar summer at Florianka station, which was located at the highest position (270 m above sea level) in relation to other measurement stations covered by this study. In terms of plant protection, the mean tropospheric ozone concentration, expressed with the use of AOT40, did not exceed the applicable target level (18 000 μg∙m-3∙h) at any of the measurement stations. The highest mean value of AOT40 was recorded at the Florianka meteorological station (14 653.9 μg∙m-3∙h), while the lowest was recorded at the Jarczew station (7 486.2 μg∙m-3∙h).
Źródło:
Journal of Ecological Engineering; 2019, 20, 10; 233-240
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies