Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "oxygen uptake" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Modeling the total energy costs of resistance exercise: a work in progress
Autorzy:
Scott, Christopher B.
Reis, Victor M.
Powiązania:
https://bibliotekanauki.pl/articles/1054988.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
intermittent exercise
oxygen uptake
weight lifting
Opis:
We present an aerobic and anaerobic, exercise and recovery energy cost model of intermittent energy costs utilizing task (work, Joules) as opposed to rate (per minute) measurements. Low to moderate intensity steady state exercise energy costs are typically portrayed as the volumetric rate at which oxygen is consumed (VO2 L min–1), where a proportionate upward climbing linear relationship is profiled with an increasing power output; add to this the concept of the anaerobic threshold and energy costs increase with more intense aerobic exercise in disproportion to VO2 L min–1 measurements. As a per task function, intermittent work and recovery bouts contain a combined estimate of total costs, that is as kJ or kcal (not kJ.min-1 or kcal.min-1). Adopting this approach to describe single and multiple sets of resistance training, the model that emerges for intermittent resistance exercise portrays linearity between equivalent work and total energy costs that differs proportionately among conditions – “continuous” muscular endurance vs. Intermittent higher load strength work, moderately paced vs. slower and faster conditions, smaller vs. larger working muscle masses and failure (fatigue) vs. non-failure states. Moreover, per kcal (or kJ) of total energy costs, work (J) is more inefficient with a greater load and lower repetition number as opposed to lower resistance with an increased number of repetitions. The concept of energy costs Rusing disproportionately with increased or prolonged work does not appear to apply to resistance exercise.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 14, 2; 5 - 12
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of 3 months workout on cardiovascular capacity of a female amateur cross country skier. Case study
Autorzy:
Grzebisz, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/1179508.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
amateur
cardiovascular capacity
cross-country skiing
oxygen uptake
Opis:
The efficiency in cross-country skiing commit considerable physiological challenges posed by the combined upper- and lower-body effort of varying intensity and duration. Extremely important for the effectiveness of the work is the ability to draw energy from the processes of aerobic and anaerobic metabolism maintenance work as low as possible during prolonged exercise. The workout should increase maximal aerobic power and the metabolic potential of the muscles. High-intensity exercise is the most important to initiate this change, while low- and moderate-intensity effort allow appropriate muscle adaptation. Monitoring and evaluation of these physiological changes is mandatory in the process of training, in amateur cross-country skier too. Amateur marathons are becoming increasingly popular. This has been an impulse for analyzing the results obtained by the amateur athlete during the preparatory period. The purpose of this retrospective case study was to describe changes in cardiovascular capacity for three months period of an amateur cross-country skier (age = 39, BMI = 20,9). This study based on analysis of source materials, obtained from conducted individually by the athlete registration process of training, the results from test to refuse and the results of measurements of body composition performed in the laboratory functional studies for three months period (preparation period). The results show inter alia increase in maximal oxygen uptake, lactate threshold shift towards higher loads and decrease body weight. This parameter was significantly lower than the performance in highly qualified competitors, but individual changes between the first measurement and the second one was similar. This review summarizes research on amateur cross-country skier. We have the chance to improve our understanding of the impact of various exercises on the human body by analyzing the results from workout monitoring of endurance athletes.
Źródło:
World Scientific News; 2017, 78; 365-375
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Respirometric Activity of Activated Sludge and Biofilm in IFAS-MBBR System
Autorzy:
Piechna, P.
Żubrowska-Sudoł, M.
Powiązania:
https://bibliotekanauki.pl/articles/124065.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
IFAS-MBBR
activated sludge
biofilm
Oxygen uptake rate
OUR
Opis:
The aim of the presented study was: a) assessment of activity of microorganisms developed in form of activated sludge and biofilm, b) indirect assessment of the role of analyzed biocoenoses in removal of organic compounds in hybrid reactor with moving bed. Oxygen uptake rate tests (OUR) have been used, and obtained results were presented as volumetric activity.(Ѵvo2 , expressed in mg O2/L·h) and mass activity (Ѵvo2, expressed as mg O2/g VTS·h). Tests were conducted for three different variants, in which, as the biomass: 1) biofilm was used, 2) activated sludge was used, 3) biofilm and activated sludge were used. The biomass was collected from aerobic reactor from a wastewater treatment plant working in IFAS-MBBR system. The highest volumetric activity was observed for variant with biofilm and activated sludge, and the lowest for variant with biofilm only. Nonetheless, the highest value of oxygen uptake rate related to total volatile solids was observed for variant with biofilm and the lowest for activated sludge. Obtained results suggest, that during this research, at the wastewater treatment plant, the main role in removal of organic pollutants played the biomass developed in form of activated sludge.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 145-151
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physiological background of the change point in VO2 and the slow component of oxygen uptake kinetics
Autorzy:
Zoladz, J.A.
Korzeniewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/69946.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Fizjologiczne
Tematy:
muscle fatigue
acid-base status
kinetics
exercise
respiratory muscle
oxygen uptake
Źródło:
Journal of Physiology and Pharmacology; 2001, 52, 2
0867-5910
Pojawia się w:
Journal of Physiology and Pharmacology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja systemu do pomiaru temperatury podczas prób wysiłkowych u dzieci
The concept of a system for temperature measurement during exercise tests for children
Autorzy:
Rafiński, L.
Łuszczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/156799.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
temperatura
wysiłek fizyczny
biometria
temperature
incremental exercise
maximum oxygen uptake
biometrics
Opis:
Odpowiednia podaż tlenu i gwarancja prawidłowego metabolizmu tlenowego organizmu należą do głównych czynników determinujących wydolność fizyczną człowieka oraz możliwość kontynuowania przez niego wysiłku fizycznego. Od lat trwają badania nad instrumentami pomocnymi w ocenie zmian przystosowawczych oraz adaptacyjnych, zachodzących pod wpływem wysiłku fizycznego oraz treningu fizycznego. W przypadku grup pediatrycznych poddawanych pomiarom w warunkach wysiłku fizycznego, pożądane są narzędzia bezpieczne, łatwe w użyciu, niezależne od wieku i płci, łatwo dostępne, przenośne, niedrogie oraz umożliwiające pomiar w czasie rzeczywistym, nieinwazyjny i powtarzalny. Prócz tych wskazań istotne jest, aby stanowiły one system umożliwiający szybką ocenę zmian i interpretację wyników, co zwiększałoby bezpieczeństwo przeprowadzania badań. W niniejszym artykule przedstawiono koncepcję systemu pomiarowego do pomiaru temperatury podczas prób wysiłkowych u dzieci. System projektowano z założeniem wykorzystania w badaniach potwierdzających uzyskane z wcześniejszych badań zależności między oksygenacją tkanki mózgowej, wybranymi parametrami spiroergometrycznymi (pCO2) a temperaturą skóry w okolicach tej samej tkanki.
The response of adult organisms to physical exercise and physical training is well documented. The same, however, cannot be said about children. This situation is the result of ethical problems of measuring a child’s body response. A great deal of important information concerning the integrated pulmonary–cardiovascular–muscle metabolic response to exercise can be acquired from the breath-by-breath measurement of pulmonary gas exchange (PGE) during ramp incremental exercise tests – CPET (cardiopulmonary exercise test). The authors decided to add a temperature measurement to the standard measurement techniques when designing a measurement system. The body temperature is a parameter that differs children and adults. The physical as well as physiological differences between children and adults may explain a different response to thermal stress [7]. The paper presents the design of a new measurement system customized for measurements of human body temperature during exercise tests (CPET) for children. The temperature measurement system was designed to be used as a complementary part of the measurement system used during cardiopulmonary tests. In the paper there are also given the test results of a prototype of the temperature measurement system. Based on the tests one can conclude that the designed system allows for the temperature measurement of chosen parts of the child’s body during endurance tests using a non-invasive and fairly comfortable method. The use of the designed system should allow for further investigation of the relation between skin temperature and hemoglobin oxygenation [6] and the assumption that temperature changes, monitored in the real time, are a possible factor in determining the maximum intensity of an exercise, especially for children exercise tests. The extra information provided will allow for an increase of the safety of exercise tests, especially for children.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 6, 6; 582-585
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Role of calcitonin gene related peptide in the modulation of intestinal circulatory, metabolic and myoelectric activity during ischemia-reperfusion
Autorzy:
Pawlik, W.W.
Obuchowicz, R.
Biernat, J.
Sendur, R.
Jaworek, J.
Powiązania:
https://bibliotekanauki.pl/articles/70549.pdf
Data publikacji:
2000
Wydawca:
Polskie Towarzystwo Fizjologiczne
Tematy:
metabolic activity
intestinal circulation
peptide
blood flow
ischaemia
myoelectrical activity
calcitonin gene
oxygen uptake
Źródło:
Journal of Physiology and Pharmacology; 2000, 51, 4,2
0867-5910
Pojawia się w:
Journal of Physiology and Pharmacology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Total benthic oxygen uptake in two Arctic fjords (Spitsbergen) with different hydrological regimes
Autorzy:
Kotwicki, L.
Grzelak, K.
Opalinski, K.
Weslawski, J.M.
Powiązania:
https://bibliotekanauki.pl/articles/48291.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
oxygen uptake
Arctic fjord
Spitsbergen
hydrological regime
organic matter
biomass
marine sediment
benthic organism
Źródło:
Oceanologia; 2018, 60, 2
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pomiarowy do urządzenia typu stepper dedykowany do prób wysiłkowych
A measurement system for a stepper device for the purpose of endurance testing\
Autorzy:
Golijanek-Jędrzejczyk, A.
Ogielski, M.
Rafiński, L.
Powiązania:
https://bibliotekanauki.pl/articles/267274.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
system pomiarowy
próba wysiłkowa
test Astranda-Ryhminga
measurement system
maximal oxygen uptake
Astrand-Rhyming submaximal test
Opis:
W artykule przedstawiono system pomiarowy opracowany do urządzenia typu stepper, umożliwiającego przeprowadzenie próby wysiłkowej zgodnie z testem Astrand’aRyhminga. Budowa prototypu systemu pomiarowego wymagała modyfikacji mechanicznej urządzenia typu stepper udostępnionego przez Akademię Wychowania Fizycznego i Sportu w Gdańsku oraz doboru części sprzętowej systemu pomiarowego (czujników, mikrokontrolera). Celem projektu było również wykonanie oprogramowania umożliwiającego rejestrację i wizualizację wyników pomiarowych oraz wyznaczenie parametrów stosowanych do oceny wydolności organizmu człowieka W artykule zaprezentowano wyniki z przeprowadzonych testów potwierdzające poprawność opracowanego systemu pomiarowego.
This paper presents the design and construction of the measurement system for a stepper device, for the purpose of executing endurance tests in accordance with Astrand’a - Rhyming submaximal test. Astrand'a - Rhyming submaximal test is the most widely used indirect method in determining parameter VO2max, which is determined by the heart rate at submaximal work. This test requires the stepper with a height of 30 cm and 40 cm (respectively for women and men) a stopwatch and a metronome. The metronome frequency is set at 90 beats per minute. The exercise time is about 5 minutes. The construction of the prototype measurement system required a mechanical modification of the stepper device provided by the Gdańsk University of Physical Education and Sport as well as designing the hardware part of the measurement system (sensors, electronics, microcontroller). A specialized software that enables registration and visualization of test results was also made. The paper presents test results to confirm the correctness of the designed system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 59-62
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of the 1-mile run test evaluation formulae: Assessment of aerobic capacity in male law enforcement officers aged 20–23 years
Autorzy:
Kayihan, Gürhan
Özkan, Ali
Köklü, Yusuf
Eyuboğlu, Ender
Akça, Firat
Koz, Mitat
Ersöz, Gülfem
Powiązania:
https://bibliotekanauki.pl/articles/2178814.pdf
Data publikacji:
2014-05-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
Maximal oxygen uptake
field aerobic tests
police officers
one mile run test
physical fitness
young adults
Opis:
Objectives: The purpose of this study was to compare values of aerobic performance in the 1-mile run test (1-MRT) using different formulae. Material and Methods: Aerobic capacities of 351 male volunteers working for the Turkish National Police within the age range of 20-23 years were evaluated by the 1-MRT and the 20-metre shuttle run (20-MST). $\text{VO}_\text{2max}$ values were estimated by the prediction equations developed by George et al. (1993), Cureton et al. (1995) and Kline et al. (1987) for the 1-MRT and by Leger and Lambert (1982) for the 20-MST. Results: The difference between the results of the different formulae was significant (p = 0.000). The correlation coefficient between the estimated $\text{VO}_\text{2max}$ using Cureton's equation, George's equation, Kline's equation and the 20-MST were 0.691 (p < 0.001), 0.486 (p < 0.001) and 0.608 (p < 0.001), respectively. The highest correlation coefficient was between the $\text{VO}_\text{2max}$ estimated by the 20-MST and Cureton's equation. Similarly, the highest correlation coefficient (r = -0.779) was between the 1-mile run time and the $\text{VO}_\text{2max}$ estimated by Cureton's equation. Conclusions: When analysing more vigorous exercise than sub-maximal exercise, we suggest that Cureton's equation be used to predict the $\text{VO}_\text{2max}$ from 1-mile run/walk performance in large numbers of healthy individuals with high $\text{VO}_\text{2max}$. This research compares the use of 3 different formulae to estimate $\text{VO}_\text{2max}$ from 1-mile run/walk performance in male law enforcement officers aged 20-23 years for the first time and reports the most accurate formula to use when evaluating aerobic capacities of large numbers of healthy individuals.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 2; 165-174
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dezaktywacja osadu czynnego w wyniku procesu mechanicznej dezintegracji
Deactivation of the activated sludge as a result of mechanical disintegration
Autorzy:
Walczak, J.
Żubrowska-Sudoł, M.
Garlicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/400093.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
mechaniczna dezintegracja
test szybkości poboru tlenu
stopień dezaktywacji
mechanical disintegration
oxygen uptake rate test
degree of deactivation
Opis:
Przedmiotem przeprowadzonych badań była ocena wpływu procesu hydrodynamicznej dezintegracji zagęszczonych osadów nadmiernych, prowadzonego przy różnych poziomach gęstości energii (70, 140, 210, 280 i 350 kJ/l), na aktywność oddechową mikroorganizmów zasiedlających kłaczki osadu czynnego. W tym celu wykorzystano test szybkości poboru tlenu (OUR). W zakres pracy wchodziło również wyznaczenie stopnia dezintegracji osadu (DD). W badaniach wykazano, że wartość gęstości energii przy jakiej prowadzono proces hydrodynamicznej dezintegracji oraz stopień dezintegracji osadów wpływały na aktywność oddechową mikroorganizmów. Przy stosunkowo niskim stopniu dezintegracji, poniżej ok. 9% (co odpowiadało gęstości energii na poziomie ok. 140 kJ/l), zaobserwowano wzrost aktywności mikroorganizmów w stosunku do osadów nie poddanych dezintegracji (o 6,2−30,2%). Zaś powyżej tej wartości dochodziło do dezaktywacji mikroorganizmów. Wysoką, ponad 85% dezaktywację mikroorganizmów obserwowano, gdy stopień dezintegracji był większy od 24% (co odpowiadało gęstości energii na poziomie ok. 210 kJ/l).
The aim of the study was to analyse the impact of hydrodynamic disintegration of thickened excess activated sludge, performed at different levels of energy density (70, 140, 210 280 and 350 kJ/l), on the respiratory activity of microorganisms. For this purpose the oxygen uptake rate test (OUR) was used. The experiment also included determination of the sludge disintegration degree (DD). Studies have shown, that the value of the energy density and sludge disintegration degree affected the respiratory activity of microorganisms. With a relatively low DD, below approx. 9% (corresponding to an energy density of approx. 140 kJ/l), increase of microbial activity was observed (6,2−30,2%), as compared with untreated sludge. However, above this value of DD, inactivation of microorganisms occurred. Deactivation of microorganisms higher than 85 % was observed when the sludge disintegration degree was greater than approx. 24% (corresponding to an energy density of approx. 210 kJ/l).
Źródło:
Inżynieria Ekologiczna; 2017, 18, 3; 114-121
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Purine metabolism in the light of aerobic and anaerobic capacity of female boxers
Autorzy:
Domaszewska, Katarzyna
Szewczyk, Piotr
Kryściak, Jakub
Michalak, Edyta
Podgórski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1030895.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
Acid-Base Balance (ABB)
Wingate anaerobic test
anaerobic threshold (AT)
maximal oxygen uptake
purine nucleotides
uric acid
Opis:
The aim of the work was to assess the intensity of purine nucleotide degradation during maximum physical exercise. 5 elite female boxers were the subject of the study. Each of them underwent two exercise stress tests in order to evaluate the level of V̊O2peak and the level of anaerobic capacity during a Wingate test. The study involved collecting capillary and venous blood samples at rest and after the exercise test to determine the Acid-Base Balance (ABB), concentration of lactic acid (LA) and purine metabolism nucleotides. The average value of V̊O2peak was 40.92 (SD = 4.087) ml/kg/min, the average anaerobic capacity Ppeak was 7.57 (SD = 0.380) Watt/kg. The workload resulted in significant changes in the level of ABB and LA after both of the exercise stress tests (p < 0.001). Concentrations of hypoxanthine (Hx), xanthine (X) and uric acid (UA) in the blood increased significantly after the Wingate test (p < 0.05). The level of plasma purine nucleotides at rest and after standard exercise may be a useful tool for monitoring the adaptation of energetic processes in different training phases and support the overload diagnosis.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2020, 30, 2; 97-106
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy Cost of the Trondheim Firefighter Test for Experienced Firefighters
Autorzy:
Von Heimburg, E.
Medbo, J. I.
Powiązania:
https://bibliotekanauki.pl/articles/89766.pdf
Data publikacji:
2013
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
blood lactate concentration
fire fighting
maximal oxygen uptake
lactate threshold
pulmonary ventilation
rating of perceived exertion
wentylacja płuc
straż pożarna
środowisko cieplne
strażak
środowisko gorące
Opis:
Aim. The aim of this study was to measure aerobic demands of fire fighting activities including exercise in the heat. Methods. Twenty-two experienced firefighters performed the Trondheim test simulating fire fighting tasks including work in the heat. Maximal oxygen uptake (VO2 max), heart rate (HR) and ventilation were recorded continuously. Data were compared with results obtained during a treadmill test during which the participants were dressed as smoke divers. Results. The participants completed physical parts of the Trondheim test in ~12 min (range: 7.5–17.4). Time to complete the test was closely related to the participant’s VO2 max. HR of ~170 beats/min and pulmonary ventilation of ~100 L/min were higher than at lactate threshold (LT) during laboratory tests. VO2 averaged over the test’s physical part was 35 ± 7 ml/min/kg, which was at the same or below the level corresponding to the participants’ LT. Physically fit participants completed the test faster than less fit participants. Slower and physically less fit participants consumed more air and used more oxygen than faster and physically more fit participants. Conclusion. The Trondheim test is physically demanding; it distinguishes physically fit and less fit participants.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2013, 19, 2; 211-225
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Role of capsaicin-sensitive neurons in the control of intestinal blood flow and oxygen uptake
Autorzy:
Gustaw, P
Pawlik, W.W.
Jacobson, E.D.
Sendur, R.
Konturek, S.J.
Powiązania:
https://bibliotekanauki.pl/articles/69977.pdf
Data publikacji:
1995
Wydawca:
Polskie Towarzystwo Fizjologiczne
Tematy:
intestinal blood flow
enteric nervous system
blood flow
sensory neuron
extrinsic nerve
neuron
human physiology
periarterial capsaicin
dog
vascular resistance
intrinsic nervous system
oxygen uptake
neural fibre
Źródło:
Journal of Physiology and Pharmacology; 1995, 46, 1
0867-5910
Pojawia się w:
Journal of Physiology and Pharmacology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological aspects of cadmium and lead uptake by Phragmites australis [Cav. Trin ex Steudel] in natural water ecosystems
Biologiczne aspekty poboru kadmu i olowiu przez Phragmites australis [Cav. Trin ex Steudel] w naturalnych zbiornikach wodnych
Autorzy:
Kozlowska, M
Jozwiak, A.
Szpakowska, B.
Golinski, P.
Powiązania:
https://bibliotekanauki.pl/articles/14041.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Tematy:
plant
natural environment
stress factor
oxidative stress
reactive oxygen species
heavy metal
accumulation
cadmium
lead
common reed
Phragmites australis
water reservoir
lake
cadmium uptake
lead uptake
statistical analysis
bottom sediment
antioxidative enzyme
Opis:
In natural environment plants are exposed to many different stress factors, including heavy metals, whose elevated concentration causes oxidative stress, connected with formation of reactive oxygen species (ROS). Therefore, plants have developed defence systems, including enzymatic antioxidant system, able to remove ROS. The work concerns the accumulation of two heavy metals, cadmium (Cd) and lead (Pb), as well as the phenomenon of oxidative stress caused by increased concentration of these metals in common reed (Phragmites australis), a dominant species in the littoral zone of many water reservoirs. The plants were obtained from four water bodies situated in Poznan: Kierskie Lake, Rusałka Lake, Strzeszyńskie Lake and Sołacki Pond. The aim of the study was to examined the accumulation of heavy metals and the relation between activity of antioxidant enzymes in rhizome, stem and reed leaves during the vegetative period. Three antioxidant enzymes were analyzed: ascorbate peroxidase (APX), guaiacol peroxidase (GPX) and superoxide dismutase (SOD). The statistical analysis was done to determine the influence of the heavy metals on the activity of the antioxidant enzymes, involved in limiting and removing results of oxidative stress. Heavy metals were accumulated in common reed in all the four water reservoirs, but the activity of enzymes was variable during the observation period. Statistical analyses suggest that there are some correlations among concentration of metals and the activity of antioxidative enzymes. However, the results do not provide an unambiguous determination of the effect of heavy metals on enzymatic activity. Summing up, the contamination of the water ecosystems caused by heavy metals was so low that it did not influence the activity of the analysed enzymes.
W środowisku naturalnym rośliny są narażone na działanie metali ciężkich. Nadmierne ich stężenia w roślinach powodują stres oksydacyjny, wywoływany powstawaniem reaktywnych form tlenu (ROS). W celach obronnych organizmy roślinne wykształciły wiele systemów antyoksydacyjnych, w tym enzymatyczne umożliwiające usuwanie ROS. Praca dotyczy akumulacji dwóch metali ciężkich – kadmu (Cd) i ołowiu (Pb) oraz zjawiska stresu oksydacyjnego w roślinach powodowanego przez nadmierne stężenia jonów metali ciężkich w środowisku oraz w organach trzciny pospolitej (Phragmites australis) – gatunku występującego i dominującego w strefie litoralnej wielu zbiorników. Materiał roślinny pochodził z czterech zbiorników wodnych zlokalizowanych w obrębie miasta Poznania: Jeziora Kierskiego, jeziora Rusałka, Jeziora Strzeszyńskiego i Stawu Sołackiego. Celem badań było określenie zależności między zawartością metali ciężkich a aktywnością enzymów antyoksydacyjnych w kłączach, łodydze i liściach trzciny na przestrzeni okresu wegetacyjnego. Analizowano aktywność trzech enzymów antyoksydacyjnych: peroksydazy askorbinianowej (APX) i gwajakolowej (GPX) oraz dysmutazy ponadtlenkowej (SOD). Przeprowadzono analizy statystyczne celem określenia wpływu czynników stresu oksydacyjnego wywołanego przez metale ciężkie na aktywność enzymów antyoksydacyjnych, które są zaangażowane w ograniczanie i usuwanie skutków tego zjawiska. Metale ciężkie akumulowane w roślinach we wszystkich ocenianych zbiornikach wodnych wykazywały tendencję wzrostową, natomiast aktywność enzymów w roślinach była silnie zróżnicowana w całym okresie obserwacji. Analizy statystyczne sugerują wprawdzie istnienie pewnych korelacji między stężeniem metali w roślinach a aktywnością enzymów antyoksydacyjnych, jednakże nie pozwala to na jednoznaczne określenie wpływu badanych metali na zmienność w aktywności tych enzymów. Podsumowując, stwierdzone skażenie ekosystemów wodnych metalami ciężkimi było na tyle niskie, że nie wpływało modyfikująco na aktywność badanych enzymów.
Źródło:
Journal of Elementology; 2009, 14, 2; 299-312
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies