Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "otoacoustic emissions" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Hearing status of people occupationally exposed to ultrasonic noise
Autorzy:
Dudarewicz, Adam
Zamojska-Daniszewska, Małgorzata
Zaborowski, Kamil
Pawlaczyk-Łuszczyńska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2084911.pdf
Data publikacji:
2022-06-08
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
noise
pure-tone audiometry
otoacoustic emissions
noise-induced hearing loss
ultrasonic noise
extended high-frequency audiometry
Opis:
ObjectivesThe aim of the study was to evaluate the hearing status of operators of low-frequency ultrasonic devices compared to employees exposed to audible noise at a similar A-weighted sound pressure level (SPL) but without ultrasonic components.Material and MethodsStandard pure-tone audiometry, extended high-frequency audiometry (EHFA), transient-evoked otoacoustic emissions (TEOAE), and distortion-product otoacoustic emissions (DPOAE), as well as questionnaire surveys were conducted among 148 subjects, aged 43.1±10.8 years, working as ultrasonic device operators for 18.7±10.6 years. Their exposure to noise within the ultrasonic and audible frequency range was also evaluated. The control group comprised 168 workers, adjusted according to gender, age (±2 years), tenure (±2 years), and the 8-hour daily noise exposure level (LEX,8h) of ±2 dB.ResultsThe ultrasonic device operators and the control group were exposed to audible noise at LEX,8h of 80.8±3.9 dB and 79.1±3.4, respectively. The Polish maximum admissible intensity (MAI) values for audible noise were exceeded in 16.8% of the ultrasonic device operators, while 91.2% of them were exposed to ultrasonic noise at SPL>MAI values. There were no significant differences between the groups in terms of the hearing threshold levels (HTLs) up to 3 kHz, while the ultrasonic device operators exhibited significantly higher (worse) HTLs, as compared to the control group, in the range of 4–14 kHz. The results of the DPOAE and TEOAE testing also indicated worse hearing among the ultrasonic device operators. However, the differences between the groups were more pronounced in the case of EHFA and DPOAEs.ConclusionsThe outcomes of all hearing tests consistently indicated worse hearing among the ultrasonic device operators as compared to the control group. Both EHFA and DPOAE seem to be useful tools for recognizing early signs of hearing loss among ultrasonic device operators.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 3; 309-325
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in Distortion Product Otoacoustic Emission Caused by Contralateral Broadband Noise
Autorzy:
Ozimek, E.
Wicher, A.
Powiązania:
https://bibliotekanauki.pl/articles/177139.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distortion product otoacoustic emissions
DPOAEs
contralateral acoustic stimulation
CAS
contralateral suppression
Opis:
The main purpose of this investigation was to measure the effect of contralateral acoustic stimulation (CAS) on distortion product otoacoustic emission (DPOAE) in twenty human ears, for a ratio of primary tones f2/f1 = 1.22 and a wide frequency range of f2 (1.4–9 kHz), for two intensity levels of primary tones (L1 = 60 dB SPL; L2 = 50 dB SPL and L1 = 70 dB SPL; L2 = 60 dB SPL) and two intensity levels of CAS (50 and 60 dB SPL). It was found that in the presence of CAS, in the majority of cases the DPOAE level decreased (suppression), but it might also increase (enhancement) or remain unchanged depending on the frequency. The mean suppression level of the component of the frequency fDP = 2f1 − f2 might be approximated by a linearly decreasing function of the f2 frequency of primary tones. The slope of this function was negative and increased with an increase of the contralateral stimulation level. The higher was the contralateral noise level the greater was the suppression. For the fDP level below about 15 dB SPL, suppression was observed in a substantial number of measurement cases (in about 85% of all measured cases on average). When the fDP level was higher than 15 dB SPL, only suppression (not enhancement) was observed.
Źródło:
Archives of Acoustics; 2014, 39, 1; 125-138
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Ability in Orchestral Musicians
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Zamojska, M.
Śliwińska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/177978.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
musicians
exposure to orchestral noise
hearing impairment
pure-tone audiometry
transient-evoked otoacoustic emissions
Opis:
Pure-tone audiometry (PTA) and transient-evoked otoacoustic emissions (TEOAEs) were determined in 57 classical orchestral musicians along with a questionnaire inquiry using a modified Amsterdam Inventory for Auditory Disability and Handicap ((m)AIADH). Data on musicians’ working experience and sound pressure levels produced by various groups of instruments were also collected. Measured hearing threshold levels (HTLs) were compared with the theoretical predictions calculated according to ISO 1999:1990. High frequency notched audiograms typical for noise-induced hearing loss were found in 28% of the subjects. PTA and TEOAE consistently showed a tendency toward better hearing in females vs. males, younger vs. older subjects, and lower- vs. higher-exposed to orchestral noise subjects. Audiometric HTLs were better than theoretical predictions in the frequency range of 2000–4000 Hz. The (m)AIADH scores indicated some hearing difficulties in relation to intelligibility in noisy environment in 26% of the players. Our results indicated a need to implement a hearing conservation program for this professional group.
Źródło:
Archives of Acoustics; 2010, 35, 4; 579-594
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Status in Young People Using Portable Audio Players
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Zaborowski, K.
Zamojska-Daniszewska, M.
Rutkowska-Kaczmarek, P.
Dudarewicz, A.
Śliwinska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/176501.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
portable audio players
PAPs
pure-tone audiometry
transient-evoked otoacoustic emissions
TEOAEs
hearing threshold levels
high-frequency notches
noise-induced hearing loss
Opis:
The aim of this study was to evaluate the hearing status in young adults using portable audio players (PAPs) in relation to their listening habits. The study included 58 subjects, aged 22.8±2.8 years, non-occupationally exposed to noise. Questionnaire inquiry aimed at collecting personal data, the information on PAPs usage habits, self-assessment of hearing status and identification of risk factors for noise-induced hearing loss (NIHL) were performed in study subjects. Hearing tests included pure-tone audiometry (PTA) and transient-evoked optoacoustic emission (TEOAE). All subjects were PAPs users. Depending on listening habits they were divided into the subgroups of “frequent” users (>1 h/day) and “non-frequent” users (≤1 h/day). There were no significant differences between subgroups in prevalence of NIHL risk factors and self-assessment of hearing status. However, frequent users more often complained of tinnitus and hyperacusis. Majority (81.9 %) of participants had normal hearing. Nevertheless, 6.9 % of audiograms showed high-frequency notches typical for NIHL. Both, the PTA and TEOAE indicated worse hearing in non-frequent users compared to frequent users. No significant differences in prevalence of high-frequency notches between subgroups were noted. The outcomes do not support some previous studies results that the excessive exposure to music listened through PAPs might result in accelerating of development of NIHL loss in young adults.
Źródło:
Archives of Acoustics; 2017, 42, 1; 113-120
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noise exposure and hearing status among employees using communication headsets
Autorzy:
Pawlaczyk-Łuszczyńska, Małgorzata
Dudarewicz, Adam
Zaborowski, Kamil
Zamojska-Daniszewska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2153012.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
noise-induced hearing loss
pure-tone audiometry
otoacoustic emissions
communication headsets
occupational exposure to noise
extended high-frequency audiometry
Opis:
Objectives The objective of this study was to assess the hearing of employees using communication headsets with regard to their exposure to noise. Material and Methods The study group comprised 213 employees, including 21 workers of the furniture industry, 15 court transcribers and 177 call center operators, aged 19–55 years, working with headsets for a period of up to 25 years. All the participants underwent a standard puretone audiometry, extended high-frequency audiometry (EHFA) as well as transient-evoked otoacoustic emissions (TEOAEs) and distortion-product otoacoustic emissions (DPOAEs). Noise exposure from headsets was evaluated using the microphone in a real ear technique according to PN-EN ISO 11904-1:2008. Results Personal daily noise exposure levels ranged 57–96 dB and exceeded 85 dB only in 1.4% of the call center operators. Forty-two percent of the participants had bilateral normal hearing in the standard frequency range of 250–8000 Hz, and 33% in the extended highfrequency range of 9–16 kHz. It was found that DPOAEs were present bilaterally in 59% of the participants. Reproducibility of TEOAE at >70% and signal-to-noise ratio at >6 was exhibited by 42% and 17% of them, respectively. The 3 subgroups of workers differed in age, gender, noise exposure and type of headsets in use. However, after adjusting for age and gender, significant differences between these subgroups in terms of hearing were mostly visible in EHFA. A significant impact of age, gender, daily noise exposure level and current job tenure on hearing tests results was also noted among the call center operators and the transcribers. The most pronounced were the effects of age and gender, whereas the impact of the daily noise exposure level was less evident. Conclusions It seems that EHFA is useful for recognizing early signs of noise-induced hearing loss among communication headset users. However, further studies are needed before any firm conclusions concerning the risk of hearing impairment due to the use of such devices can be drawn.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 5; 585-614
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of a Single Therapeutic Dose of Methadone on Selected Auditory Functions in Patients Addicted to Opioids and Undergoing Substitution Therapy – a Preliminary Study
Autorzy:
Tarnowska, E.
Wicher, A.
Sęk, A.
Gorzelańczyk, E. J.
Powiązania:
https://bibliotekanauki.pl/articles/176565.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
methadone
opioids
speech intelligibility
otoacoustic emissions
hearing threshold
Opis:
The main purpose of this research was to determine the influence of a therapeutic dose of an opioid drug (methadone) on selected auditory functions in patients addicted to opioids (recognition ICD-10; F11) and undergoing substitution therapy. Various hearing tests were used in this research – pure tone audiometry, impedance audiometry, otoacoustic emission measurement, and a speech in noise test – in two sessions, before and after methadone intake. It was found that methadone causes an improvement in speech intelligibility when speech is presented in speech-like noise, and slightly decreases hearing thresholds [dB HL]. Methadone consumption has no significant impact on distortion product otoacoustic emissions levels (DPOAE). In summary, a prescribed methadone dose does not worsen the hearing of opioid-dependent subjects.
Źródło:
Archives of Acoustics; 2018, 43, 1; 137-146
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies