Tytuł:
Microstructure and Properties of YSZ Coatings Prepared by Plasma Spray Physical Vapor Deposition for Biomedical Application
Autorzy:
Barczyk, J.
Dercz, G.
Matuła, I.
Góral, M.
Maszybrocka, J.
Bochenek, D.
Gurdziel, W.
Powiązania:
https://bibliotekanauki.pl/articles/356455.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PS-PVD method
bioactive coatings
cp-Ti
YSZ
osseointegration
Opis:
This paper presents the study of microstructure and properties of 8 mol% yttrium stabilized zirconia coating fabricated by Plasma Spray Physical Vapor Deposition technique on commercial pure titanium. The coating was characterized by X-ray diffraction, high resolution scanning electron microscope, profilometer, nanoindentation and nanomachining tests. The X-ray phase analysis exhibit the tetragonal Zr0.935 Y0.065O1.968, TiO and α-Ti phases. The Rietveld refinement technique were indicated the changes of crystal structure of the produced coatings. The characteristic structure of columns were observed in High Resolutions Scanning Electron Microscopy. Moreover, the obtained coating had various development of surfaces, thickness was equal to 3.1(1) μm and roughness 0.40(7) μm. Furthermore, the production coatings did not show microcracks, delamination and crumbing. The performed experiment encourages carried out us to tests for osseointegration.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 2; 779-783
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mostowanie kręgosłupa” – stop tytanu a polimer PEEK w zastosowaniu na międzytrzonową stabilizację kręgosłupa
Bridging of spine” – titanium alloy and polymer PEEK for intervertebral stabilization of spine
Autorzy:
Ciupik, L. F.
Kierzkowska, A.
Sterna, J.
Pieniążek, J.
Cieślik-Górna, M.
Powiązania:
https://bibliotekanauki.pl/articles/285663.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stabilizacja kręgosłupowa
osteointegracja
implant Ti-3D-Truss
spinal stabilization
osseointegration
Ti-3D-Truss implant
Opis:
W implantologii kręgosłupowej stosowane są dwa typy implantów: „non-fusion” oraz „fusion”, czyli odpowiednio bez zrostu i ze zrostem kostnym. Większą grupę stanowią stabilizacje ze zrostem kostnym, dla których szybkość oraz jakość osteointegracji ma kluczowe znaczenie dla końcowego efektu leczenia. Najczęściej stosowanymi biomateriałami są stopy tytanu oraz polimer PEEK (polieteroeteroketon) o różnej topografii powierzchni 2D oraz przestrzennej konstrukcji 3D wynikających z zastosowanej obróbki wykańczającej, warstw powierzchniowych, metod wytwarzania. Wykazano, że osteointegracja zależy w dużym stopniu od m.in. odpowiedniej konfiguracji 2D i 3D, topografii, porowatości oraz energii powierzchniowej. W pracy przeanalizowano wpływ rodzaju biomateriału: stop Ti6Al4V ELI, PEEK Optima oraz technologii wytwarzania implantów: ubytkowa (PEEK, Ti), przyrostowa EBT - Electron Beam Technology (Ti-3D-Truss) na osteointegrację. Z zachowaniem analogicznych warunków procesu, jak przy produkcji implantów, przygotowano modele/próbki, które poddano badaniom biologicznym in vitro oraz in vivo na zwierzętach. Pobrane preparaty zwierzęce z modelami implantów oceniano pod kątem osteointegracji z użyciem przemysłowej tomografii rentgenowskiej CTt. Wyniki potwierdziły biokompatybilność badanych biomateriałów, a tym samym bezpieczeństwo stosowania w chirurgii kostnej. Implantowe stopy Ti6Al4V ELI w porównaniu z polimerem PEEK są korzystniejszymi biomateriałami na stabilizację międzytrzonową typu „fusion”. Polimer PEEK Optima jest dobrym materiałem w stabilizacjach typu „non-fusion”. Wykorzystanie technologii przyrostowej EBT do wytwarzania implantów z proszków Ti6Al4V ELI pozwala na uzyskanie „wulkanicznych” powierzchni oraz przestrzennych/ kratownicowych konstrukcji Ti-3D-Truss o dużym rozwinięciu powierzchniowym, które sprzyjają i przyspieszają przerost/obrost tkanki kostnej przez implant. Dotychczasowe doniesienia kliniczne wskazują na poprawę efektywności chirurgicznego leczenia, polegającego na przyspieszonym zroście kostnym w „mostowaniu” kręgosłupa z wykorzystaniem implantów międzytrzonowych typu Ti-3D-Truss.
In spinal implantology there are two types of implants: “non-fusion” and “fusion”, that is without and with bone overgrowth, respectively. A larger group consists of stabilization with bone overgrowth, for which speed and quality of osseointegration is crucial for final treatment outcome. The most commonly used biomaterials are titanium alloys and polietero-eteroketon (PEEK) of different 2D surface topography and 3D spatial structure resulting from the finishing, surface layers or production methods. It has been shown that osseointegration depends largely on suitable configuration of 2D and 3D, topography, porosity and surface energy. The impact of biomaterial type: Ti6Al4V titanium alloy ELI, PEEK OPTIMA and implant production technology: deficient (PEEK, Ti), incremental EBT-Electron Beam Technology (Ti-3D-Truss) on the osseointegration were analyzed. In compliance with corresponding process conditions of implant production, models/samples were prepared and subjected to in vitro biological tests and in vivo animal tests. Collected animal specimens with implants models were tested for osseointegration with the use of CTt tomography. The results confirmed the biocompatibility of tested biomaterials, and thus safety in the bone surgery. Ti6Al4V ELI alloys compared with PEEK polymer are favourable biomaterials for “fusion” interbody stabilization. The polymer PEEK Optima is preferred material for “non-fusion” stabilizations. The use of EBT technology for implant production made of Ti6Al4V ELI powder allows to obtain “volcanic” surfaces and spatial/lattice Ti-3D-Truss structures with a large surface area which accelerate the bone over-/in-growth through the implant. Previous reports indicate improved clinical effectiveness of surgical treatment involving the accelerated bone overgrowth in the “bridging” of spine with the use of Ti-3D-Truss interbody implants.
Źródło:
Engineering of Biomaterials; 2015, 18, 133; 14-21
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości stanu powierzchni wszczepu śródkostnego po jego dezintegracji z kością
Quality evaluation of intraosseous implant surface condition after the unsuccessful process of osseointegration
Autorzy:
Krauz, D.
Ziębowicz, A.
Bączkowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/98712.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
wszczep śródkostny
osteointegracja
SLActive
SEM
intraosseous implant
osseointegration
Opis:
Celem pracy była ocena jakości stanu powierzchni implantu, która mogłaby wskazywać na przyczynę utraty integracji wszczepu śródkostnego. Badania obejmowały obserwacje mikroskopowe oraz analizę składu chemicznego wszczepu śródkostnego w mikroskopie skaningowym firmy ZEISS SUPRA 35 wyposażonego w detektor SE. Potwierdziły one wykonanie implantu ze stopu Ti- 6Al-4V oraz wskazały na zaistniały proces osteointegracji. Powodem utraty zintegrowanego wszczepu było prawdopodobnie przeciążenie mechaniczne oraz złe nawyki higieniczne, palenie tytoniu oraz współistniejąca choroba przyzębia i wywołane nią periimplantitis.
The aim of the study was the quality assessment of the state of the surface of the implant. The study included microscopic observations and analysis of the chemical composition of the implant intraosseous scanning microscope ZEISS SUPRA 35 equipped with a detector SE. They confirmed the execution of the implant alloy Ti-6Al-4V, and pointed to an apparent process of osseointegration. The reason of incorrect implants integration was probably mechanical overload or poor hygiene habits, smoking and periodontal disease – periimplantitis.
Źródło:
Aktualne Problemy Biomechaniki; 2017, 12; 51-56
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the material’s stiffness on stress-shielding in osseointegrated implants for bone-anchored prostheses: a numerical analysis and initial benchmark data
Autorzy:
Prochor, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/27324152.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Young’s modulus
bone mass
bone remodelling
osseointegration
bone-anchored prosthesis
moduł Younga
masa kostna
przebudowa kości
osteointegracja
proteza zakotwiczona w kości
Opis:
This study attempted to establish the link between design of implants for bone-anchored prostheses and stress-shielding, affecting the stability of the bone-implant coupling using numerical approach. The objectives were to share a numerical model capable to evaluate the long-term stability of implants and to use this model to extract data sets showing how shape and material stiffness of threaded, press-fit and modular press-fit implants affect stress-shielding intensity. Methods: Three designs were considered: threaded, press-fit and modular press-fit. The effect of shape and material stiffness of each design on stress-shielding intensity was assessed using Young’s modulus (10 to 210 GPa). Furthermore, the impact of the diameter of percutaneous part (10 to 18 mm) and thickness of medullar part (5 to 1 mm) was investigated for the modular press-fit implant. Results: The threaded design generated 4% more bone mass loss at the distal femur but an overall loss of bone mass was by 5% lower to press-fit design. The influence of Young’s modulus on bone mass changes was noticeable for modular press-fit implant, depending on diameter of percutaneous or medullary part. A 20 GPa change of stiffness caused a bone mass change from 0.65% up to 2.45% and from 0.07% up to 0.32% for percutaneous parts with 18 mm and 10 mm diameter, respectively. Conclusions: Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 2; 69--81
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies