Tytuł:
Preliminary evaluation of selected biologic properties of TiO2 and SiO2 layers on metallic substrates
Autorzy:
Urbański, W.
Dragan, S.
Gębarowska, E.
Dzięgiel, P.
Krzak-Roś, J.
Miller, M.
Pezowicz, C.
Będziński, R.
Powiązania:
https://bibliotekanauki.pl/articles/284506.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
sol-gel coating
fibroblast
cytotoxicity
orthopaedic implant
Opis:
Despite of applying modern biomaterials during constructing long term orthopaedic implants, in clinical practice there are still present wide range of complications, particularly concerning matter of implant - tissue interactions. Since interaction between implant and living tissue depends mainly on biomaterial surface features, we decided to modify orthopaedic alloys to improve their biological properties. The object of this experiment was in vitro evaluation of selected biological properties, particularly cytotoxicity of titanium alloy and 316L stainless steel substrates coated with SiO2 or TiO2 thin films. The coatings were synthesized by sol-gel method. Each samples was placed into mouse fibroblast culture. The cultures in presence of tested materials were maintained for three days. We found no distinct toxic effect of tested biomaterials. We noticed increase of fibroblast proliferation in cultures with uncoated titanium and particularly SiO2 coated titanium plates.
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 129-133
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie tarcia sztucznych stawów biodrowych : przegląd
Examination of the friction behaviour of artificial HIP joints : brief overview
Autorzy:
Leshchynsky, V.
Powiązania:
https://bibliotekanauki.pl/articles/211431.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
endoproteza
sztuczny staw biodrowy
tarcie
zużycie
smarowanie
orthopaedic implant
artificial HIP joint
friction
wear
lubrication
Opis:
W artykule analizowany jest stan wiedzy na temat warunków kinematycznych, tarcia i zużycia THR. Pokazano, że: 1) geometria złącza HIP określa warunki wpływu tarcia i zużycia; 2) tribologia (tarcie i zużycie) sztucznych stawów HIP (związanych z biokompatybilnością) to dwa kluczowe aspekty odpowiedzialne za kliniczny sukces implantu stawu biodrowego; 3) konieczna jest symulacja tarcia i zużycia w rzeczywistych warunkach pracy stawu biodrowego HIP, w celu oceny skuteczności różnych rozwiązań implantów biodrowych, poprzez porównanie ich parametrów tarcia w zależności od warunków smarowania i mechanizmów zużycia kontrolowanych za pomocą tarcia. Opracowano zmodyfikowany schemat kinematyczny symulatora ruchu z uwzględnieniem poszczególnych składowych ruchu oraz pomiarem siły tarcia komponentów i momentu obrotowego. Zainstalowane osobne czujniki obciążenia pozwalają mierzyć siłę osiową Fz wzdłuż osi kości udowej (z), moment Mz wokół osi z oraz momenty w osiach Mx i My. Opracowano procedurę obliczania parametrów tarcia i smarowania podczas całego cyklu symulacji, która zostanie wykorzystana do przetwarzania danych eksperymentalnych z testów symulacyjnych. Wyniki obliczeń parametrów Sommerfelda w każdym punkcie cyklu ruchu wraz ze schematem obciążenia normalnego pokazują, że parametr Sommerfeld zmienia się nieznacznie w zakresie 11,2·10-8–4,0·10-8 dla 50% cyklu. Zatem zmienność rzeczywistych warunków smarowania obciążonej części dla danego cyklu jest stosunkowo niewielka.
State-of-art of studies of kinematic conditions, friction and wear of THRs is analysed. It is shown that: 1) geometry of the HIP joint defines the friction and wear regimes of its action; 2) tribology (friction and wear) of the artificial HIP joints, associated with biocompatibility, are two critical aspects responsible for the clinical success of a hip implant; 3) the simulation of the friction and wear in real conditions of artificial HIP joint action is needed to assess the performance of different hip implant designs by comparing their friction parameters depending on lubrication conditions and wear mechanisms controlled by friction. The modified kinematic scheme of the friction simulator with separate moving and measurement of the frictional torque components is developed, and the simulator is built. The separate load cells installed allow to measure axial force Fz along the femoral (z) axis, moment Mz about the z-axis and moments about orthogonal axes Mx and My. The calculation procedure of the friction and lubrication parameters during the whole simulation cycle is developed, and will be applied for processing of the experimental data of simulation tests. The results of Sommerfeld parameter calculation in each point of the gain cycle together with normal load diagram reveal that Sommerfeld parameter varies slightly within the range of 1.2·10-8–4.0·10-8 for 50% of the cycle. So, the variation of the real lubrication regime of the loaded part of the gain cycle is relatively small.
Źródło:
Obróbka Plastyczna Metali; 2018, 29, 4; 381-398
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of a pulsed magnetic field on selected polymer implant materials
Autorzy:
Szponder, Tomasz
Stodolak-Zych, Ewa
Polkowska, Izabela
Sobczyńska-Rak, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/306606.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pole magnetyczne
biomateriały
implant ortopedyczny
magnetic field
biomaterials
orthopaedic implants
Opis:
Physiotherapy with the use of pulsed magnetic fields is one of the methods of activating the processes of bone healing and regeneration. Exposing materials serving as membranes in guided bone regeneration (GBR) or guided tissue regeneration (GTR) to magnetic fields is an effective model that allows to monitor changes in the material under the influence of the magnetic field. Methods: Materials engineering methods were used to verify the extent of material degradation resulting from magnetic field exposure in an aqueous environment. Changes in surface morphology were observed under an optical microscope and a scanning electron microscope (SEM). Changes in surface wettability were analysed in relation to the direct contact angle. Chemical structural changes were verified with the use of infrared spectroscopy (FTIR-ATR). Results: The PCL-based membrane materials underwent relatively moderate surface degradation (altered contact angle, changes in surface morphology), but the absence of observable FTIR-ATR spectral shifts evidenced material stability under the influence of magnetic field. More extensive degradation processes were observed in the case of PLDLA-based materials, whose surface character changed from hydrophilic to hydrophobic. The spectra revealed enhanced intensity of the chain terminal groups, provided that modifiers (nanometric SiO2 and TCP (water reservoir)) were present in the polymer matrix. Conclusions: The extent degradation in the polymer membrane was primarily dependent on the presence of aqueous environment, while the influence of the magnetic field on the analysed membrane materials was negligible. Therefore, GBR/GTR membrane implants can be considered to remain stable during rehabilitation with the use of alternating magnetic field.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 1; 87-96
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warstw DLC i DLC-Si na zmiany zachodzące na powierzchni implantów podczas współpracy z kością
The influence of the DLC and DLC-Si coatings on the changes occurring on the implants surface during the implant-bone contact
Autorzy:
Świątek, L.
Olejnik, A.
Grabarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/286121.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
DLC
Si
implant
wkręty ortopedyczne
trybologia
RF PACVD
implants
orthopaedic screws
tribology
Opis:
Niniejsza praca została poświęcona badaniu wpływu modyfikacji implantów medycznych warstwami węglowymi (DLC) oraz węglowymi domieszkowanymi krzemem (DLC-Si) na zmiany zachodzące w wyniku współpracy implantu z kością. Warstwy węglowe zostały wytworzone modyfikowaną metodą chemicznego osadzania z fazy gazowej – RF PACVD. W celu przeprowadzenia badań zostały użyte dwa rodzaje podłoży – pierwszą grupę stanowiły płaskie próbki cylindryczne, natomiast drugą wkręty ortopedyczne. Wszystkie wykorzystane próbki zostały wytworzone ze stali AISI 316 LVM. Przygotowane próbki z warstwami węglowymi zostały przebadane pod względem charakteryzacji powierzchni. W celu sprawdzenia składu chemicznego oraz topografii powierzchni przeprowadzono analizy XPS oraz AFM. Warstwy węglowe zostały również przebadane pod kątem wybranych właściwości mechanicznych (twardość, moduł Younga, adhezja), a także właściwości trybologicznych (test ball-on disc). Niemodyfikowane oraz modyfikowane wkręty ortopedyczne zostały poddane próbom wkręcania w kość wołową. Przeprowadzono testy wkręcania oraz wykręcania wkrętów w kość (w liczbie 1, 10, 50 oraz 100 cykli). Celem badań było określenie zmian zachodzących na powierzchni implantów w momencie ich współpracy z kością. Próbki po przeprowadzonych testach zostały poddane obserwacji mikroskopowej (SEM) oraz analizie jakościowej składu chemicznego na powierzchni wkrętów (EDS). Obserwacje mikroskopowe pozwoliły zaobserwować, iż do powierzchni modyfikowanych wkrętów ortopedycznych adherują elementy kości, tworząc silnie związany z powierzchnią tribofilm, co nie występuje w przypadku wkrętów niemodyfikowanych. Analiza EDS pozwoliła na potwierdzenie, iż w składzie chemicznym tribofilmu obecnego na implantach znajdują się mineralne składniki kości.
In this study the DLC and Si-incorporated DLC layers were deposited on stainless steel alloy (AISI 316 LVM) using modified radio frequency plasma assisted chemical vapour deposition (RF PACVD) method and examined in terms of chemical, mechanical and tribological properties. The carbon layers were synthesized on two types of samples: flat cylindrical probes and the orthopaedic screws (both were made from AISI 316 LVM). In order to determine the chemical composition, morphology and structure of the manufactured coatings the XPS, AFM, SEM observation and EDS analysis were performed. Mechanical properties were measured using nanoindentation technique, as well as the tribological properties were performed using ball-on-disc tests. The obtained results were correlated with the biological response of the coatings. The influence of changes of the modified implants surface was evaluated using screwing/unscrewing test. The samples after conducted tests were controlled using microscopic observation (SEM) and qualitative analysis of the chemical composition on the surface of the screws (EDS). Results demonstrate that on the surface of the DLC and DLC-Si coatings the tribofilm made from mineral bone compounds was created.
Źródło:
Engineering of Biomaterials; 2016, 19, 137; 2-12
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies