Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "orifice" wg kryterium: Temat


Tytuł:
Discharge of a Triangular Orifice under Free Flow Conditions
Autorzy:
Sosnowska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2097770.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
orifice
orifice equation
discharge
Opis:
In this paper, flow through a free triangular orifice is considered. The comparison of two formulas was conducted for discharge calculations: a large orifice formula and a small orifice formula. The results show that, above a certain value of upstream head to orifice height ratio there is no need for small-large formula discrimination. The differences in the outcomes for the two formulas are negligible for upstream head to orifice height ratios greater than 3. This means that a small orifice formula can be used instead of a large orifice formula. Calculations were performed for different variants of triangle orientation (with tip downwards, sidewards and upwards) as well as for different dimensions of orifice (equilateral and isosceles). The calculations also included different submergence levels of the upper edge of the orifice and variable dimensions of the orifice with constant upstream head. Neither of these conditions affect the relative deviation values for small and large orifice formulas.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2021, 68, 1; 19--28
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Equivalence of Small and Large Orifice Computational Models
Autorzy:
Kubrak, M.
Powiązania:
https://bibliotekanauki.pl/articles/241432.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
orifice
velocity
flow
computational models
Opis:
The aim of this paper was to analyze theoretical aspects of calculating steady water flow through unsubmerged circular orifices. Theoretical analysis shows that the values of discharge obtained by using formulas intended for small orifices are greater than those calculated using formulas for large orifices. These differences attain a maximum value when the water level reaches the upper edge of the orifice, and decrease when water head increases. It has been proven that the volumetric flow rate for circular unsubmerged orifices can be calculated by formulas for small orifices when the water level above the center of gravity is at least four times as high as the diameter of the orifice.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2015, 62, 3-4; 67-76
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of two-phase gas-liquid flow using standard and slotted orifice
Pomiar strumienia mieszaniny gaz-ciecz z wykorzystaniem kryzy standardowej i kryzy szczelinowej
Autorzy:
Tomaszewska-Wach, Barbara
Rząsa, Mariusz
Majer, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/408428.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
standard orifice
slotted orifice
mixture gas-liquid
kryza standardowa
kryza szczelinowa
mieszanina gaz-ciecz
Opis:
The differential pressure of gas measurement is very often used in industrial measurements. During the gas flow, liquid condensation often occurs. The result is that when measuring a gas flow, the gas-liquid mixture is essentially measured. Errors in the indications of measuring instruments are starting to appear due to a change in the properties of the continuous phase, which is gas. In addition, the appearance of liquid droplets leads to flow disturbances and pressure pulsations. Therefore, new methods and tools for measuring the flow of gas-liquid mixture are being sought. The work involves the use of slotted orifices for measuring gas-liquid mixtures. An analysis of the influence of the slotted orifice geometry on the measurement of the biphasic mixture stream was carried out. Standard orifice and three slotted orifices of various designs. The experiment included measuring the air flow with a small amount of water dispersed in the form of drops.
Pomiar gazu metodą zwężkową jest bardzo często stosowany w pomiarach przemysłowych. Podczas przepływu gazu bardzo często dochodzi do wykroplenia się cieczy. Powoduje to, że mierząc przepływ gazu w zasadzie mierzy się mieszaninę gaz – ciecz. Zaczynają pojawiać się błędy wskazań przyrządów pomiarowych wynikających ze zmiany właściwości fazy ciągłej, którą jest gaz. Dodatkowo pojawienie się kropel cieczy prowadzi do powstawania zaburzeń przepływu i pulsacji ciśnienia. W związku z tym poszukuje się nowych metod i narzędzi do pomiaru przepływu mieszaniny gaz-ciecz. Praca obejmuje zastosowanie kryz szczelinowych do pomiaru mieszanin gaz-ciecz. Przeprowadzono analizę wpływu geometrii kryzy szczelinowej na pomiar strumienia mieszaniny dwufazowej. Badaniom kryzę standardową oraz trzy kryzy szczelinowe o różnych konstrukcjach. Eksperyment obejmował pomiar przepływu powietrza z niewielką ilością wody rozproszonej w postaci kropel.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 4; 30-33
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usability of selected turbulence models for simulation flow through a pipe orifice
Autorzy:
Dobrowolski, B.
Kręcisz, K.
Spyra, A.
Powiązania:
https://bibliotekanauki.pl/articles/1964150.pdf
Data publikacji:
2005
Wydawca:
Politechnika Gdańska
Tematy:
CFD
turbulence models
orifice
flow simulation
Opis:
A modern CFD code was used to simulate fluid flow through a pipeline with an orifice. A two-dimensional flow was assumed. The influence of the turbulence model and the size of the numerical grid on the quality of the obtained results was tested. It appears from the performed calculations that the standard Launder-Spalding k-[eta] model yields the best results for two-dimensional flows through pipeline-orifice systems.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2005, 9, 4; 439-448
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas Atomization Parametric Study on the VIGA-CC Based Synthesis of Titanium Powder
Autorzy:
Kim, Dae-Kyeom
Kim, Young-Il
Lee, Hwaseon
Kim, Young Do
Lee, Dongju
Lee, Bin
Kim, Taek-Soo
Powiązania:
https://bibliotekanauki.pl/articles/355636.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
powder production
gas atomization
titanium
orifice
Opis:
With the recent advancement in technology for titanium metal powder injection molding and additive manufacturing, high yield and good flowability powder production is needed. In this study, titanium powder was produced through vacuum induction melting gas atomization with a cold crucible, which can yield various alloy compositions without the need for material pretreatment. The gas behavior in the injection section was simulated according to the orifice protrusion length for effective powder production, and powder was prepared based on the simulation results. The gas distribution changes with the orifice protrusion length, which changes the location of the recirculation zone and production yield of the powder. The produced powders had a spherical morphology, and the content of impurities (N, O) changed with the injected-gas purity.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 3; 997-1000
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania teoretyczno-eksperymentalne przepływu płynu nieściśliwego przez kryzę szczelinową
Theoretical and experimental study of incompressible fluid flow through a slotted orifice
Autorzy:
Tomaszewska, B.
Powiązania:
https://bibliotekanauki.pl/articles/408679.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
kryza standardowa
kryza szczelinowa
CFD
rozkład ciśnienia
współczynnik przepływu
standard orifice
slotted orifice
pressure distribution
flow coefficient
Opis:
W praktyce pomiarowej coraz częściej stosuje się prototypowe rozwiązania konstrukcyjne przepływomierzy zwężkowych. Na uwagę zasługują kryzy szczelinowe, gdzie jeden centralny otwór zastąpiony jest szczelinami. W pracy przedstawiono wyniki badań numerycznych i eksperymentalnych prototypowego rozwiązania konstrukcyjnego kryzy szczelinowej. Ruch płynu opisano równaniami Reynoldsa, domkniętymi k-ε modelem turbulencji. Obliczenia przeprowadzono przy użyciu pakietu ANSYS Fluent. Rozpatrywano przepływ płynu przez kryzę standardową i szczelinową o przewężeniu β = 0,5. Wyniki obliczeń porównano z wynikami pomiarów. Stwierdzono dobrą jakościową i ilościową zgodność wyników badań dla współczynnika przepływu C. Wykazano, że kryza szczelinowa generuje znacznie mniejszą trwałą stratę ciśnienia niż kryza standardowa przy porównywalnej niepewności pomiaru.
Prototype designs of orifice flowmeters are commonly used in measurements. One area which has attracted considerable interest includes slotted orifices, where a single central opening is replaced by the use of several slots. This paper reports the results of numerical and experimental research of a prototype design of a slotted orifice plate. The movement of the fluid was described with use of Reynolds equations closed by the k-ε turbulence model. The calculations were performed using ANSYS Fluent software package by consideration of the fluid flow through an orifice plate and slotted orifice with the equal β ratio = 0.5. The results of calculations are compared with the measurements. Good qualitative and quantitative conformity was obtained during the study for the C flow coefficient. It was indicated that the slotted orifice generates a considerable lower pressure drop in comparison to an orifice plate while maintaining comparable level of measurement uncertainty.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 2; 62-65
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation study of hydrodynamic cavitation in the orifice flow
Autorzy:
Pietrykowski, Konrad
Karpiński, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/38436947.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
cavitation
CFD
fluid flow
hydrodynamics
orifice
simulation
Opis:
Hydrodynamic cavitation is a phenomenon that can be used in the water treatment process. For this purpose, venturis or orifices varying in geometry are used. Studying this phenomenon under experimental conditions is challenging due to its high dynamics and difficulties in measuring and observing the phase transition of the liquid. For this reason, the CFD method was used to study the phenomenon of hydrodynamic cavitation occurring in water flow through the orifice and then analyze flow parameters for different boundary conditions. The research was performed for four different orifice geometries and two defined fluid pressure values at the inlet, based on a computational 2D model of the research object created in Ansys Fluent software. As a result of the numerical simulation, the distribution of fluid velocity and pressure and volume fraction of the gas phase were obtained. A qualitative and quantitative analysis of the phenomenon of hydrodynamic cavitation under the considered flow conditions was conducted for the defined orifice geometries. The largest cavitation zone and thus the largest volume fraction of the gas phase was obtained for the orifice diameter of 2 mm with a sharp increase in diameter. However, the geometry with a linear change in diameter provided the largest volume fraction of the gas phase per power unit.
Źródło:
Applied Computer Science; 2022, 18, 3; 31-41
1895-3735
2353-6977
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TRUS-guided drainage of the ectopic ureter entering the prostatic urethra and TRUS-guided transurethral neo-orifice formation using holmium laser
Drenaż pod kontrolą TRUS moczowodu uchodzącego ektopowo do cewki sterczowej oraz przezcewkowe wytworzenie nowego ujścia tego moczowodu laserem holmowym pod kontrolą TRUS
Autorzy:
Białek, Waldemar
Mey, Ewa
Kawecki, Piotr
Styliński, Roman
Rudzki, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1032343.pdf
Data publikacji:
2018
Wydawca:
Medical Communications
Tematy:
TRUS
ectopic ureter
holmium laser
neo-orifice
pancreatic cyst
Opis:
A fifty-nine year-old male was hospitalized for exacerbation of chronic pancreatitis. As a gigantic cyst of the pancreatic tail was identified, it was fused with the jejunal loop. Due to persistent fever and severe symptoms in the storage and voiding phases, the patient was referred to a urologist. Because transrectal ultrasound examination revealed a fluid collection resembling the left seminal vesicle filled with purulent material, a transrectal puncture procedure was performed. The analysis of computed tomography scans led to the diagnosis of duplicated collecting system of the left kidney with the enormous ureter of the upper moiety that entered the prostate gland. In order to permanently decompress the hydronephrosed upper moiety of the left kidney, the patient was deemed eligible for endoscopic treatment. A transurethral incision through the bladder wall and the adjacent segment of the ectopic ureter was made with holmium laser under transrectal ultrasonography guidance, thus creating a neo-orifice of this ureter.
Pięćdziesięciodziewięcioletni mężczyzna został hospitalizowany z powodu zaostrzenia przewlekłego zapalenia trzustki. Rozpoznawszy olbrzymią torbiel ogona trzustki, dokonano jej zespolenia z pętlą jelita czczego. Ze względu na uporczywą gorączkę i nasilone objawy w fazie napełniania i wydalania moczu pacjent został skierowany na konsultację urologiczną. Ponieważ w przezodbytniczym badaniu ultrasonograficznym rozpoznano zbiornik płynowy przypominający pęcherzyk nasienny lewy wypełniony ropną treścią, dokonano jego punkcji z dostępu przezodbytniczego. Analiza obrazów tomografii komputerowej pozwoliła rozpoznać zdwojenie układu kielichowo-miedniczkowego nerki lewej z olbrzymim moczowodem górnego segmentu uchodzącym do stercza. W celu trwałego odbarczenia wodonerczowego segmentu górnego nerki lewej zakwalifikowano pacjenta do leczenia endoskopowego. Pod kontrolą przezodbytniczego badania ultrasonograficznego, przy użyciu lasera holmowego, dokonano przezcewkowego nacięcia przez ścianę pęcherza i przylegającego odcinka moczowodu ektopowego, wytwarzając nowe ujście moczowodu.
Źródło:
Journal of Ultrasonography; 2018, 18, 74; 255-264
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kształtu kryzy na pomiar różnicy ciśnienia przy przepływie strumienia mieszaniny gaz - ciecz
Effect of orifice design on differential pressure measurement in two two phase air-water mixture flow
Autorzy:
Tomaszewska-Wach, Barbara
Rząsa, Mariusz R.
Dobrowolski, Bolesław
Powiązania:
https://bibliotekanauki.pl/articles/267049.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kryza pomiarowa
kryza szczelinowa
pomiar strumienia gazu
mieszanina powietrze-woda
standard orifice
slotted orifice
gas mass flowrate
two phase flow
air-liquid flow
Opis:
Pomiar gazu metodą zwężkową jest bardzo często stosowany w pomiarach przemysłowych. Podczas przepływu gazu niejednokrotnie dochodzi do wykroplenia się cieczy. W efekcie zamiast przepływu jednofazowego mierzy się mieszaninę gaz – ciecz. Z tego powodu pojawiają się błędy wskazań przyrządów pomiarowych wynikające ze zmiany właściwości fazy ciągłej, którą jest gaz. Ponadto pojawienie się dodatkowej fazy prowadzi do powstawania zaburzeń przepływu i pulsacji ciśnienia. Dlatego poszukuje się nowych metod i narzędzi do pomiaru przepływu mieszaniny gaz-ciecz, które umożliwiają uzyskanie zadowalającej dokładność pomiaru, w momencie gdy pojawia się zakłócenie w postaci fazy ciekłej. Zakres badań przedstawionych w obecnej pracy obejmował zastosowanie kryz szczelinowych do pomiaru mieszanin gaz-ciecz. Przeprowadzona została analiza wpływu geometrii kryzy szczelinowej na pomiar strumienia mieszaniny dwufazowej. Badaniom eksperymentalnym poddano kryzę standardową oraz dwie konstrukcje kryz szczelinowych o różnej geometrii otworów. Eksperyment obejmował pomiar przepływu powietrza z niewielką ilością wody rozproszonej w postaci kropel. Wyniki badań porównano z wynikami uzyskanymi dla kryzy standardowej.
Gas measurements employing various slotted orifice designs are often employed in industrial applications. In the conditions of gas flow in the pipelines, we have to do with liquids condensation. As a result, the flow measurements basically involve gas-liquid mixture. For this reason, considerable errors occur in the measurement conducted by instruments resulting from the variations in the properties of the continuous phase, which is formed by gas. In addition, the occurrence of an additional phase results in flow interferences and pulsations of differential pressure. Therefore, new methods and tools are being sought with the aim of measuring the flow of gas-liquid mixtures, which will provide satisfactory accuracy of measurements in the case when flow interference occurs in the form of the liquid phase. The paper reports the results of a study concerned with the use of slotted orifices in the conditions of measurements of gas-liquid mixtures. Experimental research was carried out by application of a standard orifice and two designs of the slotted orifice with various slot geometries. The experiment involved the measurement of the air flow with a small amount of water, which was dispersed in the form of droplets. The results of the experiment were subsequently compared with the results recorded for the case of a standard orifice. The occurrence of liquid in the constant flow of air leads to the variations in the differential pressure developed at the orifice. As a result of the greater mass flow rate of water in the air flow, the value of the differential pressure developed at the orifice is the greater as well . In the conditions of the measurements of two-phase mixture, slotted orifice generate a smaller differential pressure compared to the standard orifice. Slotted orifices also demonstrate lower sensitivity to the variations in the flow rate of liquid in the gas. This is due to the fact that in this type of designs, we have to do with a local change in the beta ratio across the entire cross-section of the pipeline. The liquid droplets are entrained along with the air flow and freely pass through the obstacle, and only a small amount of liquid is held-up at the orifice. The gaps that are located across the entire volume of the tube allow the liquid drops to be carried away again by the gas stream in contrast to the standard solution. During flow measurements involving mixtures by the application of the standard orifice, an additional difficulty is associated with the fact that a large portion of the liquid is stopped at the orifice, as the flowing liquid accumulates in front of the orifice causing flow disturbances.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 85-89
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The model of the air inlet duct flow of the marine 4-stroke diesel engine
Autorzy:
Kowalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/243843.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
marine diesel engine
Venturi orifice
air flow
CFD model
air duct throttling
Opis:
The manuscript presents the model of the air flow through the air inlet duct of the marine 4-stroke engine. Presented model are computational fluid dynamic modelbased on dimensions and the construction of the real air intake duct. The measurement parameters from real object are used to the model validation. Mentioned measurements of the air flow are conducted by Venturi orifice for different loads of the engine and the different flow characteristics of the air intake duct. The results from computational fluid dynamic model are useful to calibration the orifice by setting the orifice module. The orifice module changes up to 6% of the mean values for all considered loads of the engine and throttling’s of the air intake duct. The approximation the flow characteristic for other throttling’s of the air intake duct was conducted also. The obtained approximation is useful tool to calculate the air flow to the engine for the different throttling’s than measured. Linear dependence between the air mass flow and the power of the engine at the constant engine speed was observed. The throttling of the cross section area of the air intake duct causes changing the characteristic in accordance to a second order polynomial. The maximum error of obtained approximation compared to measured values not excided 4% and mean error for all measured loads and throttling’s not exceeded 0.12%.
Źródło:
Journal of KONES; 2013, 20, 2; 193-200
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies