Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "optical imaging" wg kryterium: Temat


Tytuł:
Common path optical coherence tomography with electronic feedback for improved sensitivity
Autorzy:
Alsnaie, Khalid
Powiązania:
https://bibliotekanauki.pl/articles/27310102.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical coherence tomography
frequency domain
OCT
medical imaging
partially coherent interferometers
B-scan
Opis:
Optical coherence tomography (OCT) imaging has become a useful tool in medical diagnosis over the past 25 years, because of its ability to visualize intracellular structures at high resolution. The main objective of this work is to add electronic feedback to the optical coherence tomography setup to increase its sensitivity. Noise added to the measured interferogram obscures some details of examined tissue layered structure. Adjusting signal power level in such a way to improve signal-to-noise ratio can help to enhance image quality. Electronic feedback is added to enhance system sensitivity. A logarithmic amplifier is included in the OCT setup to automatically adapt signal level. Moreover, the resolution of the optical spectrum analyzer is controlled according to the farthest layer detected in the A-scan. These techniques are tested showing an improvement in obtained image of a human nail.
Źródło:
Optica Applicata; 2023, 53, 3; 495--504
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical design of a short-wave infrared coded aperture snapshot spectral imager based on Offner–Wynne imaging spectrometer
Autorzy:
Song, Chong
Zhou, Liang
Liu, Zhaohui
Jiang, Kai
Liu, Kai
Powiązania:
https://bibliotekanauki.pl/articles/2086755.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Offner-Wynne imaging spectrometer
CASSI
coded aperture snapshot spectral imager
short-wave infrared
optical design
Opis:
A calculation model to obtain the optimal combination of Offner–Wynne imaging spectrometer parameters to balance the RMS spot radius of the chief ray over the entire field is established. On the basis of the calculation model, an Offner–Wynne imaging spectrometer is designed, and then it is applied in a short-wave infrared coded aperture snapshot spectral imager (CASSI). The optical system of the short-wave infrared CASSI is designed by a combination method of independent design and integrated optimization. The spectral smile and spectral keystone of the optical system which operates in the 900–1700 nm band are respectively less than half a pixel. The focal length of the optical system is 1200 mm, the total optical system length is 775mm, and its average spectral resolution is 16 nm. The optical system offers the advantages of excellent imaging quality, compact optical structure, high optical transmittance, reduced spectral smile and spectral keystone.
Źródło:
Optica Applicata; 2022, 52, 2; 143--161
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Związki kompleksowe na bazie Gd(III), W(IV), Mn(II), Eu(III) i 99mTc wykorzystywane w diagnostyce medycznej
Complex compounds based on Gd(III), W(IV), Mn(II), Eu(III) and 99mTc used in medical diagnostics
Autorzy:
Pobłocki, Kacper
Drzeżdżon, Joanna
Jacewicz, Dagmara Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/2200431.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
obrazowanie medyczne
związki kompleksowe
magnetyczny rezonans jądrowy
tomografia emisyjna pojedynczego fotonu
rentgenografia
obrazowanie optyczne
medical imaging
complex compounds
magnetic resonance imaging
single-photon emission computed tomography
rentgenography
optical imaging
Opis:
Recently, hospitals have undergone major changes. Minimally invasive surgery is becoming more common, and numerous innovations are emerging, such as interventional radiology (IVR) and hybrid surgery. In order to keep pace with changes in this extremely dynamic field, scientist keep working on the development of imaging technology and the improvement of image display devices and new compounds acting as contrast agent (CA). In medicine, metals are used for diagnostic and therapeutic purposes. Inorganic elements are increasingly used as contrast agents in medical imaging due to their unique physicochemical properties. In this review, we would like to focus on the latest literature reports that contain information on Gd(III), W(IV), Mn(II), Eu(III) and 99mTc used in medical diagnostics.
Źródło:
Wiadomości Chemiczne; 2022, 76, 9-10; 803--823
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kamera termowizyjna wspomagająca nawigację pojazdów UAV
Thermal Imaging Camera Supporting the Navigation of UAVs
Autorzy:
Bieszczad, Grzegorz
Sawicki, Krzysztof
Gogler, Sławomir
Ligienza, Andrzej
Mścichowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2068623.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
termowizja
nawigacja
analiza obrazu
przetwarzanie obrazu
UAV
przepływ optyczny
thermal imaging
navigation
image analysis
image processing
optical flow
Opis:
Tematem artykułu jest ocena skuteczności opracowanego czujnika przeznaczonego do wspomagania nawigacji bezzałogowych statków powietrznych (BSP). Jego działanie opiera się na przetwarzaniu obrazów pozyskiwanych z kamery termowizyjnej pracującej w paśmie długofalowej podczerwieni (LWIR) umieszczonej pod podwoziem pojazdu. Przemieszczenie przestrzenne pojazdu określane jest poprzez analizę ruchu charakterystycznych punktów promieniowania cieplnego (grunt, las, budynki itp.) na zdjęciach uzyskanych za pomocą kamery termowizyjnej. Zakres i kierunek przemieszczenia uzyskuje się poprzez przetwarzanie strumienia kolejnych obrazów za pomocą algorytmu opartego na przepływie optycznym wyznaczanym w czasie rzeczywistym. Analiza rozkładu promieniowania pozwala na obliczenie wektora translacji kamery w przestrzeni. Zaletami systemów pomiarowych opartych na analizie obrazu termicznego, w porównaniu z tradycyjnymi inercyjnymi czujnikami nawigacyjnymi, jest brak efektu dryftu, odporność na zmiany pola magnetycznego, mała podatność na zakłócenia elektromagnetyczne oraz na zmiany warunków atmosferycznych. W przeciwieństwie do czujników czułych na światło widzialne, czujnik termowizyjny oferuje pracę w całkowitej ciemności (noce o złej pogodzie i w pomieszczeniach).
The topic of this paper is an evaluation of developed sensor intended for navigation aid of unmanned aerial vehicles (UAVs). Its operation is based on processing images acquired with a thermal camera operating in the long-wave infrared band (LWIR) placed underneath a vehicle’s chassis. The vehicle’s spatial displacement is determined by analyzing movement of characteristic thermal radiation points (ground, forest, buildings, etc.) in pictures acquired by the thermal camera. Magnitude and direction of displacement is obtained by processing the stream of consecutive pictures with optical-flow based algorithm in real time. Radiation distribution analysis allows to calculate camera’s self-translation vector. Advantages of measuring translation based on thermal image analysis is lack of drift effect, resistance to magnetic field variations, low susceptibility to electromagnetic interference and change in weather conditions as compared to traditional inertial navigation sensors. As opposed to visible light situational awareness sensors, it offers operation in complete darkness (harsh weather, nights and indoors). The topic of this paper is an evaluation of developed sensor intended for navigation aid of unmanned aerial vehicles (UAVs). Its operation is based on processing images acquired from a thermal camera operating in the long-wave infrared band (LWIR) placed underneath a vehicle’s chassis. The vehicle’s spatial displacement is determined by analyzing movement of characteristic thermal radiation points (ground, forest, buildings, etc.) in pictures acquired by the thermal camera. Magnitude and direction of displacement is obtained by processing the stream of consecutive pictures with optical-flow based algorithm in real time. Radiation distribution analysis allows to calculate camera’s self-translation vector. Advantages of measuring translation based on thermal image analysis is lack of drift effect, resistance to magnetic field variations, low susceptibility to electromagnetic interference and change in weather conditions as compared to traditional inertial navigation sensors. As opposed to visible light situational awareness sensors, it offers operation in complete darkness (harsh weather, nights and indoors).
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 3; 43--50
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of design and signal processing of polarimetric imaging cameras
Autorzy:
Bieszczad, Grzegorz
Gogler, Sławomir
Świderski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1818202.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
thermovision
imaging polarimetry
optical system
optical architectures
image processing
Opis:
Thermal-imaging systems respond to infrared radiation that is naturally emitted by objects. Various multispectral and hyperspectral devices are available for measuring radiation in discrete sub-bands and thus enable a detection of differences in a spectral emissivity or transmission. For example, such devices can be used to detect hazardous gases. However, their operation principle is based on the fact that radiation is considered a scalar property. Consequently, all the radiation vector properties, such as polarization, are neglected. Analysing radiation in terms of the polarization state and the spatial distribution of thereof across a scene can provide additional information regarding the imaged objects. Various methods can be used to extract polarimetric information from an observed scene. We briefly review architectures of polarimetric imagers used in different wavebands. First, the state-of-the-art polarimeters are presented, and, then, a classification of polarimetric-measurement devices is described in detail. Additionally, the data processing in Stokes polarimeters is given. Emphasis is laid on the methods for obtaining the Stokes parameters. Some predictions in terms of LWIR polarimeters are presented in the conclusion.
Źródło:
Opto-Electronics Review; 2021, 29, 1; 5--12
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of design and signal processing of polarimetric imaging cameras
Autorzy:
Bieszczad, Grzegorz
Gogler, Sławomir
Świderski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1818209.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
thermovision
imaging polarimetry
optical system
optical architectures
image processing
Opis:
Thermal-imaging systems respond to infrared radiation that is naturally emitted by objects. Various multispectral and hyperspectral devices are available for measuring radiation in discrete sub-bands and thus enable a detection of differences in a spectral emissivity or transmission. For example, such devices can be used to detect hazardous gases. However, their operation principle is based on the fact that radiation is considered a scalar property. Consequently, all the radiation vector properties, such as polarization, are neglected. Analysing radiation in terms of the polarization state and the spatial distribution of thereof across a scene can provide additional information regarding the imaged objects. Various methods can be used to extract polarimetric information from an observed scene. We briefly review architectures of polarimetric imagers used in different wavebands. First, the state-of-the-art polarimeters are presented, and, then, a classification of polarimetric-measurement devices is described in detail. Additionally, the data processing in Stokes polarimeters is given. Emphasis is laid on the methods for obtaining the Stokes parameters. Some predictions in terms of LWIR polarimeters are presented in the conclusion.
Źródło:
Opto-Electronics Review; 2021, 29, 1; 5--12
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Underwater Laser Imaging
Podwodne obrazowanie laserowe
Autorzy:
Metoyer, Shelby
Bogucki, Darek
Powiązania:
https://bibliotekanauki.pl/articles/32720360.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
laser imaging
imaging system
optical imaging
underwater light propagation
obrazowanie laserowe
system obrazowania
obrazowanie optyczne
propagacja światła podwodnego
Opis:
Attenuation of light in the ocean ranges widely depending on the environment and is especially significant in optical remote sensing. Absorption of light by ocean water limits the range light can travel before being extinguished. The complex interactions of scattering light and ocean water often lead to distortions of the signal as it propagates which degrades the quality and accuracy of underwater measurements. Consequently, underwater visibility (i.e. how well an object can be seen with definition at distance) can be less than 1 [m] in turbid and murky environments such as harbors. Advancements in laser imaging systems make highly accurate measurements at further ranges than has previously been possible through temporally filtering of a modulated laser signal at frequencies as high as 1 [GHz]. Here we overview the processes affecting underwater light propagation and visibility, laser imaging systems, recent advancements in the field of underwater optical imaging, and the application of such systems.
Tłumienie światła w oceanie waha się w szerokim zakresie w zależności od środowiska i jest szczególnie istotne w teledetekcji optycznej. Absorpcja światła przez wodę oceaniczną ogranicza zasięg, jaki światło może pokonać, zanim zgaśnie. Złożone interakcje rozpraszania światła i wody oceanicznej często prowadzą do zniekształceń sygnału podczas jego propagacji, co obniża jakość i dokładność pomiarów podwodnych. W związku z tym widoczność podwodna (tj. to, jak dobrze można zobaczyć obiekt z określoną odległością) może być mniejsza niż 1 [m] w mętnych i mętnych środowiskach, takich jak porty. Postępy w laserowych systemach obrazowania umożliwiają bardzo dokładne pomiary w większych zakresach niż było to wcześniej możliwe dzięki czasowemu filtrowaniu modulowanego sygnału laserowego przy częstotliwościach sięgających nawet 1 [GHz]. Tutaj dokonujemy przeglądu procesów wpływających na propagację i widoczność światła podwodnego, systemy obrazowania laserowego, najnowsze postępy w dziedzinie podwodnego obrazowania optycznego oraz zastosowanie takich systemów.
Źródło:
Polish Hyperbaric Research; 2021, 4(77); 39-52
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intraoperative imaging based on common-path time-domain reflectometry for brain tumor surgery
Autorzy:
Han, Jae-Ho
Cha, Jaepyeong
Powiązania:
https://bibliotekanauki.pl/articles/174648.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical coherence tomography
intraoperative imaging
reflectometry
endoscopy
Opis:
Minimally invasive intraoperative imaging plays a crucial role in delicate microsurgeries for precise operation monitoring in which fiber optic imaging can be considered as an endoscopy and surgical proximity guidance tool due to its compactness. This paper presents a near-infrared time-domain reflectometric common-path optical coherence tomography imaging technique using a bare-fiber probe mounted directly on a scanning galvanometer. The common-path setup allows the use of a freely adjustable optical path length and a disposable fiber probe, as well as eliminating the need for an additional dedicated reference optical path. Experimental results demonstrate clear discrimination between the brain tumor tissue and the normal tissue for mouse brains with the images acquired in real-time over a wide area. The proposed method enables real-time and in situ visualization of tumor resection for intraoperative imaging, and this study demonstrates the feasibility of its application to microsurgical interventions.
Źródło:
Optica Applicata; 2020, 50, 2; 223-227
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feasibility study of flood risk monitoring based on optical satellite data
Autorzy:
Weintrit, Beata
Osińska-Skotak, Katarzyna
Pilarska, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/2134577.pdf
Data publikacji:
2018-09-04
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
floods
satellites
optical imaging
monitoring
detection
risk management
Opis:
This article presents an extensive feasibility study of the use of optical satellite data for flood risk monitoring. The article presents a review of existing and archival satellite systems. The capabilities and restrictions of using earth observation data are presented, in relation to the identified threat and taking into account the size, genesis and cause. The initial results of the studies demonstrate the potential of very high and highresolution satellite imagery for the operational detection of damage and risk areas. In the presented approach, two analyses were conducted: bare soil detection and water range detection, based on different radiometric indices. As a result of the conducted research, the best results in bare soil detection were obtained using the MSAVI and NDVI indices. The most effective at delimiting water was the NDVI index. The automatization of satellite data processing from different satellite systems gives opportunities for hydrological services and crisis management professionals to access accurate and up-to-date information about the condition of levees for the early detection of flood risk.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2018, 22, 3; 172-180
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal mass transportation problem and freeform optics design – the identity of optimization scheme and the numerical solution method
Autorzy:
Wojtanowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/173799.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical design
freeform lens
beam shaping
non-imaging optics
Opis:
Due to outstanding light shaping potential, freeform optical surfaces have been considered theoretically from centuries. Recently, they gained increased interest due to the availability of manufacturing technologies. Nevertheless, the design of freeform surfaces still becomes a challenge, associated with advanced mathematical concepts and significant computing power. In this work, a very interesting unification of theories is mentioned. It is shown how the problem of optimal redistribution of mass, analyzed in the 18th century, corresponds to the problem of optical beam shaping realized by freeform surface. Both issues are governed by the same partial differential equation. In the paper, a novel numerical algorithm for solving this partial differential equation is discussed. As an example, a design of freeform lens, capable of casting completely arbitrary shapes, is presented.
Źródło:
Optica Applicata; 2018, 48, 3; 399-412
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Truncated two-stage compound parabolic concentrator for collecting human diffuse transmission light
Autorzy:
Gao, J.
Han, G.
Lu, Q.
Ding, H.
Xu, J.
Sun, J.
Powiązania:
https://bibliotekanauki.pl/articles/174488.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical design
compound parabolic concentrator
CPC
non-imaging optics
near infrared spectroscopy
medicine optical instrument
Opis:
We propose an optical system employing a compound parabolic concentrator for near infrared spectroscope in noninvasive blood components testing. A truncated two-stage compound parabolic concentrator system is designed, which consists of a normal first-stage compound parabolic concentrator and a truncated second-stage compound parabolic concentrator. Using advanced ray tracing technique, the optical efficiencies of truncated two-stage compound parabolic concentrator system, ellipsoidal mirror system and non-optical-focusing mirror system are calculated to be 25.4%, 22.4% and 4.0%, respectively. Furthermore, the total length of truncated two-stage compound parabolic concentrator is only about 68 mm while the ellipsoidal mirror is 110 mm. It indicates that the truncated two-stage compound parabolic concentrator system enhances the ability of concentrating human diffuse transmission light, and it is a benefit to improve signal-to-noise ratio of noninvasive biochemical analysis system efficiently. Due to the advantage of small size, it tends to achieve a miniature instrument.
Źródło:
Optica Applicata; 2018, 48, 2; 325-335
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fully-phase optical image encryption in diffractive-imaging scheme with QR-code-based random illumination
Autorzy:
Wang, Z.
Zhang, Y.
Gong, Q.
Li, S.
Qin, Y.
Powiązania:
https://bibliotekanauki.pl/articles/174126.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical encryption
diffractive imaging
fully phase
phase retrieval algorithm
Opis:
Based on a fully phase encoding and phase retrieval algorithm, a diffractive-imaging-based optical encryption scheme with random illumination is proposed. In the encryption process, a QR code image is placed in the optic path to modulate the incident light and thus generate a random illumination, which has been demonstrated to enable the proposed scheme to resist the multi-slice ptychographic phase retrieval algorithm attack. The plaintext is phase-encoded, and then encrypted by two random phase masks. The diffraction pattern in the output plane is recorded as ciphertext by a CCD camera. For decryption, an iterative phase retrieval algorithm with median filtering operation is implemented. Simulation results demonstrate the effectiveness, security, and robustness of the proposal.
Źródło:
Optica Applicata; 2017, 47, 2; 233-243
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical image encryption by using diffractive imaging with special constraint in the input plane
Autorzy:
Wang, Z.
Wang, H.
Yang, X.
Zhang, P.
Hou, C.
Qin, Y.
Powiązania:
https://bibliotekanauki.pl/articles/173781.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical encryption
diffractive imaging
bilinear interpolation
Opis:
In order to simplify the optical setup and the encryption process, a diffractive-imaging-based optical encryption system using a single diffraction pattern is proposed. A predesigned binary mask is placed before the plaintext in the encryption process, and three randomly distributed phase only masks are placed in the optical path. Only one diffraction pattern needs to be recorded as ciphertext by CCD. In the decryption process, an iterative phase retrieval algorithm is applied, in which the predesigned binary mask acts as a support constraint in the input plane. After the iterative process, an interpolation operation for the zero-valued pixels is also implemented. The effectiveness and robustness of the proposal are demonstrated by numerical simulation results.
Źródło:
Optica Applicata; 2016, 46, 1; 57-69
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring material joining processes with use of advanced vision methods
Monitorowanie procesów łączenia materiałów z wykorzystaniem zaawansowanych metod wizyjnych
Autorzy:
Mężyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/256846.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
friction stir welding
quality inspection
optical inspection
thermal imaging
zgrzewanie tarciowe
mieszanie materiału FSW
kontrola jakości
inspekcja optyczna
analiza termograficzna
Opis:
The article presents a method and a system for monitoring the processes of joining the materials with use of advanced vision techniques. The method and system are intended for use with the FSW joining method or similar techniques. The monitoring method consists in using a dual vision system comprised of a visible light camera and an infrared camera. The images recorded by both vision tracts are used to monitor the parameters of the process and to identify possible non-conformities of the weld. The developed system allows the monitoring of the process during the production of the joint with non-destructive, contactless techniques. The construction of the system allows its portability and adaptability for different types of FSW machines. Typical applications of the system include the monitoring of welding processes in the production line as well as laboratory testing for the development of the welding techniques.
W artykule zaprezentowano metodę oraz system do monitorowania procesów wytwarzania połączeń materiałowych z użyciem zaawansowanych technik wizyjnych. Metoda oraz system przeznaczone są do wykorzystania z technologią zgrzewania tarciowego z mieszaniem materiałów (FSW – ang. Friction Stir Welding) lub podobną. Metoda monitorowania polega na wykorzystaniu dualnego systemu wizyjnego składającego się z kamery światła widzialnego oraz kamery termowizyjnej. Obrazy rejestrowane w obu torach optycznych wykorzystywane są do monitorowania parametrów procesu oraz do identyfikacji potencjalnych niezgodności powstałej spoiny materiałowej. Opracowany system pozwala na monitorowanie procesu łączenia on-line z wykorzystaniem nieniszczącej, bezkontaktowej techniki pomiarowej. Konstrukcja systemu umożliwia jego montaż i adaptację do różnych typów maszyn do zgrzewania tarciowego. Typowe zastosowania dla prezentowanego rozwiązania obejmują monitorowanie procesów zgrzewania na liniach produkcyjnych oraz badania laboratoryjne, których celem jest rozwój technologii zgrzewania tarciowego.
Źródło:
Problemy Eksploatacji; 2015, 1; 37-46
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Śledzenie obiektów z wykorzystaniem obrazowania spektralnego
Object tracking with spectral imagery
Autorzy:
Tutak, K.
Pieszko, M.
Powiązania:
https://bibliotekanauki.pl/articles/131975.pdf
Data publikacji:
2015
Wydawca:
Wrocławska Wyższa Szkoła Informatyki Stosowanej Horyzont
Tematy:
obrazowanie spektralne
przetwarzanie obrazów
śledzenie obiektów
przepływ optyczny
spektralny system wizyjny
hyperspectral imaging
image processing
object tracking
optical flow
spectral vision system
Opis:
Niniejsza praca poświęcona jest analizie skuteczności śledzenia obiektów przy pomocy obrazowania spektralnego wykonywanego za pomocą 16-kanałowej kamery spektralnej rejestrującej dane w trybie wideo w zakresie 400-1000 nm. Wykorzystano algorytm Lucas-Kanade, wyznaczający przepływ optyczny w charakterystycznych punktach obrazu, określonych metodą Shi-Tomasi. Śledzenie inicjowane jest ręcznie poprzez wskazanie prostokątnego okna zawierającego obiekt. Do przetwarzania wybierany jest monochromatyczny obraz odpowiadający długości fali, dla której liczba punktów leżących w tym oknie jest największa. Zastosowano reprezentację obrazu w formie piramidy, dzięki czemu zmniejszono zależności od zmian skali obserwowanego obiektu. Otrzymane w każdym kroku śledzenia nowe pozycje punktów charakterystycznych były analizowane w celu odrzucenia obserwacji odstających. Wykonano szereg eksperymentów polegających na próbie śledzenia makiety samochodu wojskowego w trudnych warunkach oświetlenia i przy niejednorodnym tle o kolorystyce zbliżonej do barw maskujących pojazdu. Otrzymane rezultaty potwierdziły zasadność stosowania obrazowania spektralnego do śledzenia obiektów.
This paper is devoted to the analysis of the effectiveness of object tracking with spectral imagery performed with a 16-channel spectral video camera operating in the 400-1000 nm range. We used the Lucas-Kanade algorithm which computes the optical flow at characteristic points of the image which were determined by the Shi-Tomasi method. The tracking is initialized manually by pointing to a rectangular window containing the object. Monochrome image corresponding to the wavelength for which the number of points lying in this window is the greatest is selected for processing. We used a representation of an image in the form of a pyramid, so that dependence on scale changes of the observed object was reduced. New positions of characteristic points received in each step of tracking were analyzed in order to reject outliers. We performed a series of experiments that tries to track military vehicle model under difficult lighting conditions and heterogeneous background of a color similar to the vehicle masking colors. Obtained results confirmed the advisability of applying spectral imagery for object tracking.
Źródło:
Biuletyn Naukowy Wrocławskiej Wyższej Szkoły Informatyki Stosowanej. Informatyka; 2015, 5; 36-41
2082-9892
Pojawia się w:
Biuletyn Naukowy Wrocławskiej Wyższej Szkoły Informatyki Stosowanej. Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies