Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "optical coherence tomography" wg kryterium: Temat


Tytuł:
Readout System and Data Processing for OCT Pachymetry
Autorzy:
Dziewiecki, M.
Domański, G.
Frey, W.
Konarzewski, B.
Kurjata, R.
Marzec, J.
Smolnik, A.
Zaremba, K.
Ziembicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/226782.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography
pachymetry
optical signal detection
Opis:
A complete system for measurement control, signal acquisition and data processing for an OCT pachymeter is described. Moreover, dedicated data processing algorithm used for noise reduction is presented. A simple OCT scanner was built and some measurements were performed to examine the capabilities of the system.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 3; 223-230
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intraoperative imaging based on common-path time-domain reflectometry for brain tumor surgery
Autorzy:
Han, Jae-Ho
Cha, Jaepyeong
Powiązania:
https://bibliotekanauki.pl/articles/174648.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical coherence tomography
intraoperative imaging
reflectometry
endoscopy
Opis:
Minimally invasive intraoperative imaging plays a crucial role in delicate microsurgeries for precise operation monitoring in which fiber optic imaging can be considered as an endoscopy and surgical proximity guidance tool due to its compactness. This paper presents a near-infrared time-domain reflectometric common-path optical coherence tomography imaging technique using a bare-fiber probe mounted directly on a scanning galvanometer. The common-path setup allows the use of a freely adjustable optical path length and a disposable fiber probe, as well as eliminating the need for an additional dedicated reference optical path. Experimental results demonstrate clear discrimination between the brain tumor tissue and the normal tissue for mouse brains with the images acquired in real-time over a wide area. The proposed method enables real-time and in situ visualization of tumor resection for intraoperative imaging, and this study demonstrates the feasibility of its application to microsurgical interventions.
Źródło:
Optica Applicata; 2020, 50, 2; 223-227
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
Autorzy:
Antoniuk, P.
Strąkowski, M. R.
Pluciński, J.
Kosmowski, B. B.
Powiązania:
https://bibliotekanauki.pl/articles/220649.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography
corrosion
anti-corrosion coatings inspection
Opis:
Optical Coherence Tomography (OCT) is one of the most rapidly advancing techniques. This method is capable of non-contact and non-destructive investigation of the inner structure of a broad range of materials. Compared with other methods which belong to the NDE/NDT group (Non-Destructive Evaluation/Non-Destructive Testing methods), OCT is capable of a broad range of scattering material structure visualization. Such a non-invasive and versatile method is very demanded by the industry. The authors applied the OCT method to examine the corrosion process in metal samples coated by polymer films. The main aim of the research was the evaluation of the anti-corrosion protective coatings using the OCT method. The tested samples were exposed to a harsh environment. The OCT measurements have been taken at different stages of the samples degradation. The research and tests results have been presented, as well as a brief discussion has been carried out.
Źródło:
Metrology and Measurement Systems; 2012, 19, 2; 365-372
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of retina vessels by segmentation of images reconstructed from optical coherence tomography data
Autorzy:
Marciniak, Tomasz
Stankiewicz, Agnieszka
Dąbrowski, Adam
Stopa, Marcin
Rakowicz, Piotr
Marciniak, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/220715.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography
image processing
mathematical morphology
vessel segmentation
Opis:
In this paper methods and their examination results for automatic segmentation and parameterization of vessels based on spectral domain optical coherence tomography (SD-OCT) of the retina are presented. We present three strategies for morphologic image processing of a fundus image reconstructed from OCT scans. A specificity of initial image processing for fundus reconstruction is analysed. Then, the parameterization step is performed based on the vessels segmented with the proposed algorithm. The influence of various methods on the vessel segmentation and fully automatic vessel measurement is analysed. Experiments were carried out with a set of 3D OCT scans obtained from 24 eyes (12 healthy volunteers) with the use of an Avanti RTvue OCT device. The results of automatic vessel segmentation were numerically compared with those prepared manually by the medical doctor experts.
Źródło:
Metrology and Measurement Systems; 2019, 26, 3; 449-461
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Sol-Gel Derived Hydroxyapatite Enhanced with Silver Nanoparticles using OCT and Raman Spectroscopy
Autorzy:
Głowacki, M. J.
Gnyba, M.
Strąkowska, P.
Gardas, M.
Kraszewski, M.
Trojanowski, M.
Strąkowski, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/221475.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydroxyapatite
sol-gel
nanoparticles
Raman spectroscopy
optical coherence tomography (OCT)
Opis:
Hydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements of HAp molecular composition and solvent evaporation efficiency the Raman spectroscopy has been chosen. In order to evaluate dispersion and concentration of the silver nanoparticles inside the hydroxyapatite matrix, the optical coherence tomography (OCT) has been used. Five samples were developed and examined ‒ a reference sample of pure HAp sol and four samples of HAp colloids with different silver nanoparticle solution volume ratios. The Raman spectra for each solution have been obtained and analyzed. Furthermore, a transverse-sectional visualization of every sample has been created and examined by means of OCT.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 153-160
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical coherence tomography image for automatic classification of diabetic macular edema
Autorzy:
Wang, Ping
Li, Jia-Li
Ding, Hao
Powiązania:
https://bibliotekanauki.pl/articles/1835815.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
diabetic macular edema
optical coherence tomography
transfer learning
fine-tuning
Opis:
Diabetic macular edema (DME) is the dominant reason of diabetic visual loss, so early detection and treatment of DME is of great significance for the treatment of diabetes. Based on transfer learning, an automatic classification method is proposed to distinguish DME images from normal images in optical coherence tomography (OCT) retinal fundus images. Features of the DME are automatically identified and extracted by the pre-trained convolutional neural network (CNN), which only involves fine-tuning the VGGNet-16 network without any user intervention. An accuracy of 97.9% and a sensitivity of 98.0% are acquired with the OCT images in the Duke data set from experimental results. The proposed method, a core part of an automated diagnosis system of the DME, revealed the ability of fine-tuning models to train non-medical images, allowing them can be classified with limited training data. Moreover, it can be developed to assist early diagnosis of the disease, effectively delaying (or avoiding) the progression of the disease, consequently.
Źródło:
Optica Applicata; 2020, 50, 4; 567-577
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Graph-based segmentation with homogeneous hue and texture vertices
Autorzy:
Ngo, Lua
Han, Jae-Ho
Powiązania:
https://bibliotekanauki.pl/articles/2033896.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
image segmentation
deep neural network
electron microscopy
optical coherence tomography
pattern recognition
Opis:
This work presents an automated segmentation method, based on graph theory, which processes superpixels that exhibit spatially similarities in hue and texture pixel groups, rather than individual pixels. The graph shortest path includes a chain of neighboring superpixels which have minimal intensity changes. This method reduces graphics computational complexity because it provides large decreases in the number of vertices as the superpixel size increases. For the starting vertex prediction, the boundary pixel in first column which is included in this starting vertex is predicted by a trained deep neural network formulated as a regression task. By formulating the problem as a regression scheme, the computational burden is decreased in comparison with classifying each pixel in the entire image. This feasibility approach, when applied as a preliminary study in electron microscopy and optical coherence tomography images, demonstrated high measures of accuracy: 0.9670 for the electron microscopy image and 0.9930 for vitreous/nerve-fiber and inner-segment/outer-segment layer segmentations in the optical coherence tomography image.
Źródło:
Optica Applicata; 2021, 51, 4; 541-549
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advances in the diagnostics of eye diseases
Postępy w diagnostyce chorób oczu
Autorzy:
Romańczuk, Helena
Mazur, Artur
Powiązania:
https://bibliotekanauki.pl/articles/437887.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
ophthalmology
diagnostics
optical coherence tomography, perimetry
okulistyka
diagnostyka optyczna koherentna
tomografia
perymetria
Opis:
The advances in the diagnostics of eye diseases have been presented in the work including the optic coherence tomography, confocal microscopy, ultrabiomicroscopy and perimetry. Introduction: The advances in the diagnostics of eye diseases during the last decade of the 20th century and in 21st century is incomparable with the corresponding, earlier periods of development of that discipline. This can be attributed, inter alia, to the pace of the development of imaging techniquesat present at the level close to the histological picture. Objective: The latest methods of diagnosis of changes of the front and back of the eye have been presented in the paper. Material and method: The overview of the current national and foreign literature has been done, mainly for over 10 last years. The following databases have been searched: PubMed and Polska Bibliografia Lekarska.
W pracy przedstawiono postępy w diagnostyce chorób oczu, uwzględniając optyczną koherentną tomografię, mikroskopię konfokalną, ultrabiomikroskopię oraz perymetrię. Wstęp: Postęp w dziedzinie diagnostyki okulistycznej w ostatniej dekadzie XX wieku oraz w XXI wieku jest nieporównywalny z analogicznymi, wcześniejszymi okresami rozwoju tej dyscypliny. Wynika on między innymi z tempa rozwoju technik obrazowania – obecnie już na poziomie zbliżonym do obrazu histologicznego. Cel: W pracy przedstawiono najnowsze metody diagnozowania zmian przedniego i tylnego odcinka oka. Materiał i metoda: Dokonano przeglądu aktualnego piśmiennictwa krajowego i zagranicznego, głównie z ostatnich 10 lat. Przeszukano następujące bazy danych: PubMed i Polska Bibliografia Lekarska.
Źródło:
Medical Review; 2016, 4; 473-482
2450-6761
Pojawia się w:
Medical Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hyperreflective dots in optical coherence tomography
Autorzy:
Paczwa, Katarzyna
Szabelska, Paulina
Rerych, Magdalena
Różycki, Radosław
Gołębiewska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/2159017.pdf
Data publikacji:
2022-09-30
Wydawca:
Medical Education
Tematy:
hyperreflective dots
HRDs
optical coherence tomography
AMD
diabetic retinopathy
retinal vein occlusion
Opis:
Optical coherence tomography is a non-invasive and repeatable imaging method of posterior segment of the eye used in medical practice. Hyperreflective dots visible in OCT scans have been reported in various retinal diseases such as age-related macular degeneration, diabetic macular edema, retinal vein occlusion and central serous chorioretinopathy. In the future, HRDs may become a useful biomarker in making treatment decision and monitoring ocular conditions among the patients with mentioned diseases.
Źródło:
OphthaTherapy; 2022, 9, 3; 175-179
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Retained subretinal perfluorocarbon in multimodal image
Autorzy:
Guzmán Almagro, Elena
Cobo Soriano, Rosario
Fuentes-Vega, Irene
Fernández Hortelano, Ana
González Martin-Moro, Julio
Powiązania:
https://bibliotekanauki.pl/articles/2040460.pdf
Data publikacji:
2021-04-08
Wydawca:
Medical Education
Tematy:
vitreo-retinal surgery
surgical complication
optical coherence tomography
multimodal image
subretinal perfluorocarbon
Opis:
Introduction: Retained subretinal perfluoro-n-octane droplets occur in nearly 1% of the procedures. When subretinal cystoid cavities are registered, differential diagnosis including this condition is needed. Clinical case: A 77-year-old male presented three small bubbles of perfluoro-n-octane under the papillomacular bundle after vitrectomy due to a retina redetachment, evidenced by multimodal image. Conclusions: Multimodal image can help to diagnose this condition. There are several signs that can support this diagnosis. If visual acuity is threatened, removing the bubbles is mandatory, accepting risks.
Źródło:
OphthaTherapy; 2021, 8, 2; 87-91
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies