Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "optical analysis" wg kryterium: Temat


Tytuł:
Deformation measurement system for UAV components to improve their safe operation
Autorzy:
Czyż, Zbigniew
Jakubczak, Patryk
Podolak, Piotr
Skiba, Krzysztof
Karpiński, Paweł
Droździel-Jurkiewicz, Magda
Wendeker, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/28328271.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
strength tests
deformation measurement
optical displacement
deformation analysis
digital image correlation
UAV
Opis:
The paper presents the authors’ method and test rig for performing the deformation analysis of unmanned aircraft fuselages. To conduct the analysis, the DIC system was used, as well as a test rig designed and constructed by the authors, equipped with a dedicated control and load control system. The article presents a description of the research capabilities of the test rig developed for testing the deformation of unmanned aircraft fuselages. Due to the specific operating conditions of the designed fuselage,the test rig developed allows the simulation of loads corresponding to different flight conditions. In addition, it is possible to change the forces acting on the fuselage simultaneously for all servos or each of them separately. Finally, results showing the displacement of component control points for the considered fuselage versions are presented. The tests carried out using the developed test rig allowed the verification of the maximum deformations. The two versions of the composite fuselage of an aerial vehicle have been compared in the paper. The created measurement system and performed analyzes have enabled us to identify and quantitatively analyze the weaknesses of the construction. The results have enabled us to geometrically modify the constructionso the mass of the fuselage reduced by 19% and a coefficient of construction balance increased by 22%.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 4; art. no. 172358
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distribution of EC and OC temperature fractions in different research material
Dystrybucja frakcji temperaturowych EC i OC w różnych materiałach badawczych
Autorzy:
Błaszczak, Barbara
Mathews, Barbara
Słaby, Krzysztof
Klejnowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27311564.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
wet deposition
carbonaceous matter
fine PM
thermal-optical analysis
mokra depozycja
analiza termooptyczna
materia węglowa
próbki węgla
Opis:
The aim of the study was to assess the profile of EC (elemental carbon) and OC (organic carbon) temperature fractions in PM1 and PM2.5 samples and in wet deposition samples (material collected on a filter). The research was conducted at the urban background station in Zabrze (southern Poland) in the period of Oct 2020–Oct 2021. PM samples were collected with high-volume samplers; the automatic precipitation collector NSA 181 by Eigenbrodt was used to collect the deposition samples. Concentrations of EC and OC were determined using thermal-optical method (carbon analyzer from Sunset Laboratory Inc., “eusaar_2” protocol). Regardless of the type of research material, organic carbon constituted the dominant part of the carbonaceous matter, and this dominance was more visible in the non-heating season. The profile of temperature fractions of OC and EC was clearly different for dust washed out by precipitation. Noteworthy is a much lower content of pyrolytic carbon (PC) in OC, which can be explained by the fact that PC is most often combined with the water soluble organic carbon. In addition, a high proportion of the OC3 fraction was observed, followed by OC4, which may indicate that these fractions are of a more regional origin. With regard to the EC fractions, the differences are less visible and concern, in particular, the higher share of EC4 and the lower of EC2. The obtained results may be a valuable source of information about the actual status of the carbonaceous matter and its transformation in the atmosphere .
Celem badań była ocena profilu frakcji temperaturowych EC (węgiel elementarny) i OC (węgiel organiczny) w próbkach PM1 i PM2,5 oraz w próbkach depozycji mokrej (materiał zgromadzony na sączku). Badania przeprowadzono na stacji tła miejskiego w Zabrzu w okresie X 2020–X 2021. Próbki PM pobierano za pomocą poborników wysoko-objętościowych. Do poboru próbek depozycji zastosowano automatyczny kolektor opadów NSA 181 firmy Eigenbrodt. Stężenia EC i OC oznaczono metodą termiczno-optyczną (analizator węgla firmy Sunset Laboratory Inc., protokół „eusaar_2”). Niezależnie od rodzaju materiału badawczego węgiel organiczny stanowił dominującą część materii węglowej, a dominacja ta była bardziej widoczna w sezonie niegrzewczym. Profil frakcji temperaturowych OC i EC różnił się wyraźnie dla pyłu z depozycji mokrej. Na uwagę zasługuje znacznie niższa zawartość węgla pirolitycznego (PC) w OC, co można tłumaczyć tym, że PC jest najczęściej łączony z rozpuszczalnym w wodzie węglem organicznym. Ponadto zaobserwowano wysoki udział frakcji OC3, a następnie OC4, co może wskazywać na bardziej regionalne pochodzenie tych frakcji. W przypadku frakcji EC różnice są mniej widoczne i dotyczą w szczególności wyższego udziału EC4 i mniejszego EC2. Uzyskane wyniki mogą być cennym źródłem informacji o materii węglowej i przemianom jakim podlega w atmosferze.
Źródło:
Archives of Environmental Protection; 2023, 49, 2; 95--103
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimating solid contaminant levels in beach sands through petrographic analysis, screening evaluation, and optical imaging
Autorzy:
Kuś, Sebastian
Jelonek, Zbigniew
Jelonek, Iwona
Sierka, Edyta
Powiązania:
https://bibliotekanauki.pl/articles/27311567.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
beach
optical analysis
petrographic analysis
solid pollution
Opis:
Determining the level of solid pollution in beach sands located near artificial inland water bodies in order to maintain high safety standards is a difficult and expensive task. The tests aimed at determining beach pollution caused by solid wastes through analysis of toxic and chemical concentrations, are time-consuming and usually require several days before the results are available. In addition, the maintenance of the beach area involving beach raking or grooming, and the seasonal replenishment of sand makes it difficult to realistically determine the chemical or bacterial contamination of the tested material. Solid pollutants, such as glass, caps, cans, thick foil, metal, and plastic fragments, pose a greater health risk to beachgoers. The above-mentioned pollutants, especially small ones, are hardly visible on the surface or they are buried at shallow depths. Beach garbage poses a serious threat that can lead to infections from cuts and scratches. These injuries can become infected, further jeopardizing the health and lives of beachgoers due to risks like tetanus, staphylococcus, etc. The authors presented a new petrographic method aimed at assessing the quality of sand by examining the content of solid pollutants. The obtained results allowed us to conclude that the mentioned procedure can be used for a quick quantitative estimation of the content of potentially dangerous and undesirable pollutants in beach sands. Consequently, the method implemented to determent the amount of solid pollutants in beach sands has proven to be a valuable tool for recreational facility administrators, helping them in taking necessary measures to ensure the safety of beach users. Petrographic analysis of beach sands revealed the presence of pollutants of plant origin (0.4–1.8%), plastic (0.1–0.4%), paper (0.1–0.6%), charcoal (0.1–0.5%), glass (0.1–0.4%), metals (0.1–0.4%), rust (0.1–0.3%), ash and slag (0.1–0.3%), and fossil coals (0.1–0.2%).
Źródło:
Archives of Environmental Protection; 2023, 49, 3; 50--63
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geometrical and optical analysis of small-sized parabolic trough collector using ray tracing tool SolTrace
Autorzy:
Singh, Raman Kumar
Chandra, Prakash
Powiązania:
https://bibliotekanauki.pl/articles/27312206.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
parabolic trough collector
SolTrace
Monte Carlo ray tracing method
nonuniform heat flux distribution
optical analysis
geometrical analysis
Opis:
The present work is aimed at geometrical optimization and optical analysis of a small-sized parabolic trough collector (PTC). Improving the performance of parabolic trough collectors can greatly justify the use of solar energy. An optimized curvature geometry, the location of the absorber tube, and the heat flux distribution along the circumference of the absorber tube are major features in the geometric optimization and optical modelling of parabolic trough collectors. Rim angle, aperture width, the diameter of the absorber tube, receiver position, and the optimum value of heat flux are the major parameters considered in this work for geometrical and optical analysis. The Monte Carlo ray tracing method has been adopted for analysis. The non-uniform heat flux distribution profile obtained from optical analysis of the proposed parabolic trough collector has been compared with the profile available in the literature, and good agreement has been obtained, which proves the feasibility and reliability of the model and method used for this study. An experimental new small-sized parabolic trough collector has been fabricated for the optimized rim angle of 90 deg after a successful laser light feasibility test. The effect of the absorber tube position along the optical axis on the heat flux profile was analysed and found to be substantial. Furthermore, the sensitivity analysis of the parabolic trough collector using the software applied has been discussed separately.
Źródło:
Archives of Thermodynamics; 2023, 44, 3; 35--61
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia zawodowego na węgiel elementarny w zakładach stosujących maszyny i urządzenia z silnikami wysokoprężnymi
Assessment of occupational exposure to elemental carbon in plants using diesel machinery and equipment
Autorzy:
Szewczyńska, Małgorzata
Kowalska, Joanna
Pośniak, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2188905.pdf
Data publikacji:
2023-05-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
narażenie zawodowe
ocena narażenia
węgiel elementarny
spaliny silników wysokoprężnych
analiza termo-optyczna
marker spalin Diesla
occupational exposure
exposure assessment
elemental carbon
diesel exhaust
thermo-optical analysis
diesel exhaust marker
Opis:
Wstęp W artykule przedstawiono i omówiono wyniki oznaczania węgla elementarnego (elemental carbon – EC) emitowanego w spalinach silników Diesla (SSD) do powietrza stanowisk pracy, na których były wykorzystywane maszyny i urządzenia z takimi silnikami. Narażenie zawodowe na EC jako marker SSD oceniono, obejmując pomiarami 51 naziemnych stanowisk pracy z obsługą lub konserwacją silników Diesla. Przeprowadzono również pomiary na 9 stanowiskach pracy w kopalniach niewęglowych. Materiał i metody Do pobierania próbek powietrza na stanowiskach pracy maszyn i urządzeń emitujących SSD zlokalizowanych na powierzchni do oznaczania EC wykorzystano próbnik kasetowy bez impaktora z filtrem kwarcowym, a w przypadku pomiarów w kopalniach niewęglowych – próbnik do frakcji respirabilnej typu Higgins-Dewell Cyclone FH022. Do oznaczania EC zastosowano metodę analizy termo-optycznej węgla z wykorzystaniem detektora płomieniowo-jonizacyjnego. Wyniki Analiza wyników pomiarów na stanowiskach pracy zlokalizowanych na powierzchni, tj. w warsztatach samochodowych i hucie stali, wykazała, że największe stężenia EC występowały na stanowiskach pracy związanych z obsługą starych wózków widłowych. Oznaczone tam stężenia EC wynosiły, odpowiednio, 353 μg/m³ i 78 μg/m³. W kopalniach niewęglowych stężenie EC wynosiło natomiast 7,5–50 μg/m³. Wnioski Ocena narażenia na badanych stanowiskach w hucie stali wykazała największe, 7-krotne, przekroczenie najwyższego dopuszczalnego stężenia (NDS) na stanowisku operatora spalinowego wózka widłowego. Na pozostałych badanych stanowiskach pracy w warsztatach samochodowych oznaczone stężenia wynosiły 0,1–0,5 NDS lub <0,1 NDS. W kopalniach niewęglowych oznaczone stężenia odpowiadały natomiast 0,12–1 krotności NDS. Med. Pr. 2023;74(2)
Background This paper presents and discusses the results of the determination of elemental carbon emitted in diesel engine exhaust into the air of workplaces where machines and equipment with diesel engines are used. In order to assess occupational exposure to elemental carbon (EC) as a marker of exhaust gases emitted by diesel engines, 51 ground-based workplaces where people who operate or maintain equipment with this type of engine work were measured. Measurements were also carried out at 9 workplaces in non-coal mines. Material and Methods For air sampling at workplaces of diesel exhaust emitting machines and equipment located on the surface, a cartridge sampler without an impactor with a quartz filter was used for elemental carbon determination, while for measurements in non-coal mines the Higgins-Dewell Cyclone FH022 respirable fraction sampler was used. The thermo-optical carbon analysis method using a flame ionisation detector was used to determine elemental carbon. Results Analysis of the results of the determined elemental carbon concentrations at workplaces located on the ground, i.e., in car repair shops, and in the steelworks where combustion forklifts are operated, showed that the highest concentrations of elemental carbon were determined at the old forklift workplaces in the steelworks. The determined EC concentrations at these workstations were 353 μg/m³ and 78 μg/m³, respectively. In the non-coal mines, elemental carbon concentrations were in the range of 7.5–50 μg/m³. Conclusions Exposure assessment at the surveyed workplace in the steelworks showed the highest 7-fold exceedance of the maximum admissible concentration (MAC) at the position of the combustion forklift operator. At the other surveyed workplaces in the car repair shop the marked concentrations were in the range of 0.1–0.5 MAC or <0.1 MAC. In non-coal mines, the determined concentrations ranged 0.12–1 times the MAC. Med Pr. 2023;74(2)
Źródło:
Medycyna Pracy; 2023, 74, 2; 93-102
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative accuracy analysis of triangulated surface models of a fossil skull digitized with various optic devices
Autorzy:
Garashchenko, Yaroslav
Kogan, Ilja
Rucki, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/2052109.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Madygenerpeton
optical measurement
triangulated model
polygonal analysis
accuracy
Opis:
Digital metrology was applied for evaluate 3D models of the unique skull of a fossil tetrapod, Madygenerpeton pustulatum, generated using various 3D digitization methods. The skull surface is covered by minute tubercles making it challenging for digitization with appropriate accuracy. Uniqueness and fragility of the specimen preclude the use of tactile measuring systems for creating a standardized reference model. To overcome this problem, comparative analysis of the triangulated models generated from the clouds of points obtained with seven different devices was conducted using the Geomagic Studio and Autodesk PowerShape CAD software. In the proposed approach, geometrically and dimensionally closest-fitting models underwent detailed statistical analysis between surface polygons in three steps. First, 3D models obtained from different scanning methods were compared with each other in couples. Next, statistical analysis of the differences between the coupled models was performed. Finally, a rating list of the models related to the required accuracy was prepared. The proposed approach is applicable to any other scanned object, especially in palaeontological applications, where each object is unique and exhibits individual features.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 37-51
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological analysis of additively manufactured copies of a fossil skull
Autorzy:
Rucki, Mirosław
Garashchenko, Yaroslav
Kogan, Ilja
Ryba, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173724.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additive manufacturing
Madygenerpeton
optical measurement
statistical analysis
produkcja dodatkowa
pomiar optyczny
analiza statystyczna
Opis:
This paper presents the results of a metrological analysis of the additively manufactured (AM) copies of a complex geometrical object, namely the fossil skull of Madygenerpeton pustulatum. This fossil represents the unique remains of an extinct “reptiliomorph amphibian” of high importance for palaeontological science. For this research, the surface was scanned and twelve different copies were 3D-printed using various devices, materials, and AM techniques. The same digitized model was used as a reference to compare with the surfaces obtained by Mitutoyo Coordinate Measuring Machine (CMM) CRYSTA-Apex S 9166 for each copy. The fidelity of the copies was assessed through statistical analysis of the distances between compared surfaces. The methodology provided a good background for the choice of the most accurate copies and the elimination of the less accurate ones. The proposed approach can be applied to any object of complex geometry when reproduction accuracy is to be assessed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 6; art. no. e143827
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shape accuracy in single point incremental forming of conical frustums from titanium CP2 sheets
Dokładność kształtu w jednopunktowym kształtowaniu przyrostowym stożków ściętych z blach tytanowych CP2
Autorzy:
Szpunar, Marcin
Balcerzak, Maciej
Żaba, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2204384.pdf
Data publikacji:
2022
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
incremental sheet forming
titanium
springback
optical forming analysis
X-ray tomography
kształtowanie przyrostowe blach
tytan
sprężynowanie
analizy optyczne kształtowania
tomografia komputerowa
Opis:
This paper presents frustum cone drawpiece analysis made of titanium CP2 sheet by a single incremental sheet forming. Central composite design has been adopted to carry out an experiment containing 20 runs, then multi-criteria parameter optimization has been done. Optimal parameters have been validated and responses deviations do not exceed 4% compared to created models. For the drawpiece formed with optimal parameters, AGRUS optical measurement and X-ray tomography has been applied to check the obtained of the part wall thickness and general deviations compared to the CAD model. The wall angle discrepancy of the cone generatrix has also been analyzed. No gaps or ruptures have been confirmed by X-ray. The blank rolling direction has a significant effect on the drawpiece deviations. The measurement results showed deviations of the drawpiece wall angle +0.27°/- 0.06°, sheet thickness on the cone +0.012/-0.04 mm and +0.151/-0.096 mm from the reference CAD geometry.
W pracy przedstawiono analizę wytłoczek w kształcie stożka ściętego wykonanego z blachy tytanowej CP2 metodą jednopunktowego przyrostowego kształtowania. Do przeprowadzenia eksperymentu obejmującego 20 przebiegów przyjęto centralny plan kompozycyjny, następnie dokonano wielokryterialnej optymalizacji parametrów. Dokonano walidacji optymalnych parametrów, a uzyskane wyniki nie przekraczają 4% w odniesieniu do stworzonych modeli. Dla wytłoczki uformowanej z optymalnymi parametrami zastosowano pomiar optyczny AGRUS oraz tomografię rentgenowską w celu sprawdzenia uzyskanej grubości ścianki wytłoczki i odchyłek w porównaniu z modelem CAD. Przeanalizowano również rozbieżność kątów ścian tworzących stożka. Za pomocą skanu rentgenowskiego potwierdzono brak szczelin i pęknięć wytłoczki. Kierunek walcowania półfabrykatu ma istotny wpływ na odchyłki. Wyniki pomiarów wykazały odchylenia kąta ścianki wytłoczki +0,27/-0,06°, grubości ścianki na stożku +0.012/-0.04 mm oraz +0.151/-0.096 mm od geometrii referencyjnej CAD.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2022, z. 94; 63--75
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectral analysis for tilted fiber Bragg gratings in the corrosion detection for concrete structure
Autorzy:
Kwong, Kok Zee
Udos, Waldo
Lim, Kok-Sing
Lee, Foo Wei
Tan, Chee Ghuan
Samion, Muhamad Zharif
Ahmad, Harith
Powiązania:
https://bibliotekanauki.pl/articles/2172827.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tilted fibre Bragg grating
optical spectral analysis
Fourier transform
corrosion
steel bar
Opis:
An effective corrosion monitoring technique is sought after by the engineers for assessing the steel bar corrosion at the early stage for the maintenance and repair works, especially in the corrosive environments, such as coastal and marine. In this work, tilted fiber Bragg grating (TFBG) with the optical sensor is employed in corrosion monitoring of a reinforced concrete structure. Taking advantage of the high sensitivity of TFBG cladding resonance wavelengths to the change in the surrounding medium, the sensor is mounted on the steel bar that is embedded in a concreted block during an accelerated corrosion process. The acquired transmission spectrum of the TFBG during the procedure is digitally processed using Fourier Transform to produce an index that is sensitive to the generated corrosion product surrounding the TFBG sensor. This eases the analysis of the sophisticated TFBG transmission spectra. The generated index can be used as an indicator (indicator J ) for the corrosion process of the embedded steel bar in the concrete structure. This indicator J can act as an indicator to describe the corrosion activity and corrosion level at a specific point of the steel bar in concrete structures.
Źródło:
Optica Applicata; 2022, 52, 3; 429--439
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Forum ophthalmicum - how to take control over accumulation of diagnostic data from macular OCT with benefit for both doctor and patient?
Forum ophthalmicum – jak uporządkować natłok informacji z badania OCT plamki z korzyścią dla lekarza i pacjenta?
Autorzy:
Kaczmarek, Dorota Maria
Powiązania:
https://bibliotekanauki.pl/articles/2040407.pdf
Data publikacji:
2021-09-30
Wydawca:
Medical Education
Tematy:
wAMD
optical coherent tomography
anti-VEGF therapy
medical data analysis
optyczna koherentna tomografia
terapia anty-VEGF
analiza danych medycznych
Opis:
Wet age-related macular degeneration (wet AMD) is a disease which requires regular diagnostic tests such as macular optical coherent tomography which is extremely important both in diagnosis and disease monitoring. With constant aging of the population, we are dealing with an increasing incidence rate of AMD, which makes it even more important to have a tool allowing for quick and precise analysis of anatomical changes in macular region, particularly in the current complicated epidemiological situation when diagnostic time should be used most efficiently to plan the follow-up treatment. Forum® software allows for the precise analysis of many tests performed in a single patient and combining it with treatment effectiveness assessment which substantially accelerates the diagnostics.
Wysiękowa postać zwyrodnienia plamki związanego z wiekiem to schorzenie, które wymaga regularnej diagnostyki okulistycznej, głównie w postaci okresowo wykonywanej optycznej koherentnej tomografii plamki. Rola tego badania jest niezmiernie ważna zarówno w procesie diagnostyki, jak i monitorowania. Jako że wraz ze starzeniem się populacji mamy do czynienia ze wzrostem zachorowalności na wysiękową postać zwyrodnienia plamki związanego z wiekiem, coraz bardziej istotna staje się potrzeba szybkiej i precyzyjnej analizy zmian anatomicznych obszaru plamkowego, tak aby w dodatkowo skomplikowanej sytuacji epidemiologicznej maksymalnie efektywnie wykorzystać czas przeznaczony na diagnostykę oraz zaplanować dalsze etapy leczenia. Dzięki oprogramowaniu o nazwie Forum® zyskujemy możliwość precyzyjnej analizy wielu badań wykonanych u danego pacjenta, łącznie z oceną skuteczności leczenia na przestrzeni czasu, co znacznie przyspiesza procesy diagnostyczne.
Źródło:
OphthaTherapy; 2021, 8, 3; 160-165
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kamera termowizyjna wspomagająca nawigację pojazdów UAV
Thermal Imaging Camera Supporting the Navigation of UAVs
Autorzy:
Bieszczad, Grzegorz
Sawicki, Krzysztof
Gogler, Sławomir
Ligienza, Andrzej
Mścichowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2068623.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
termowizja
nawigacja
analiza obrazu
przetwarzanie obrazu
UAV
przepływ optyczny
thermal imaging
navigation
image analysis
image processing
optical flow
Opis:
Tematem artykułu jest ocena skuteczności opracowanego czujnika przeznaczonego do wspomagania nawigacji bezzałogowych statków powietrznych (BSP). Jego działanie opiera się na przetwarzaniu obrazów pozyskiwanych z kamery termowizyjnej pracującej w paśmie długofalowej podczerwieni (LWIR) umieszczonej pod podwoziem pojazdu. Przemieszczenie przestrzenne pojazdu określane jest poprzez analizę ruchu charakterystycznych punktów promieniowania cieplnego (grunt, las, budynki itp.) na zdjęciach uzyskanych za pomocą kamery termowizyjnej. Zakres i kierunek przemieszczenia uzyskuje się poprzez przetwarzanie strumienia kolejnych obrazów za pomocą algorytmu opartego na przepływie optycznym wyznaczanym w czasie rzeczywistym. Analiza rozkładu promieniowania pozwala na obliczenie wektora translacji kamery w przestrzeni. Zaletami systemów pomiarowych opartych na analizie obrazu termicznego, w porównaniu z tradycyjnymi inercyjnymi czujnikami nawigacyjnymi, jest brak efektu dryftu, odporność na zmiany pola magnetycznego, mała podatność na zakłócenia elektromagnetyczne oraz na zmiany warunków atmosferycznych. W przeciwieństwie do czujników czułych na światło widzialne, czujnik termowizyjny oferuje pracę w całkowitej ciemności (noce o złej pogodzie i w pomieszczeniach).
The topic of this paper is an evaluation of developed sensor intended for navigation aid of unmanned aerial vehicles (UAVs). Its operation is based on processing images acquired with a thermal camera operating in the long-wave infrared band (LWIR) placed underneath a vehicle’s chassis. The vehicle’s spatial displacement is determined by analyzing movement of characteristic thermal radiation points (ground, forest, buildings, etc.) in pictures acquired by the thermal camera. Magnitude and direction of displacement is obtained by processing the stream of consecutive pictures with optical-flow based algorithm in real time. Radiation distribution analysis allows to calculate camera’s self-translation vector. Advantages of measuring translation based on thermal image analysis is lack of drift effect, resistance to magnetic field variations, low susceptibility to electromagnetic interference and change in weather conditions as compared to traditional inertial navigation sensors. As opposed to visible light situational awareness sensors, it offers operation in complete darkness (harsh weather, nights and indoors). The topic of this paper is an evaluation of developed sensor intended for navigation aid of unmanned aerial vehicles (UAVs). Its operation is based on processing images acquired from a thermal camera operating in the long-wave infrared band (LWIR) placed underneath a vehicle’s chassis. The vehicle’s spatial displacement is determined by analyzing movement of characteristic thermal radiation points (ground, forest, buildings, etc.) in pictures acquired by the thermal camera. Magnitude and direction of displacement is obtained by processing the stream of consecutive pictures with optical-flow based algorithm in real time. Radiation distribution analysis allows to calculate camera’s self-translation vector. Advantages of measuring translation based on thermal image analysis is lack of drift effect, resistance to magnetic field variations, low susceptibility to electromagnetic interference and change in weather conditions as compared to traditional inertial navigation sensors. As opposed to visible light situational awareness sensors, it offers operation in complete darkness (harsh weather, nights and indoors).
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 3; 43--50
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody grawimetryczne i optyczne w pomiarach stężenia aerozoli
The use of optic and gravimetric methods relevant in aerosol concentration measurements
Autorzy:
Oberbek, Przemysław
Jakubiak, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/2202808.pdf
Data publikacji:
2021
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
analiza grawimetryczna
ocena jakości powietrza
niskokosztowe sensory optyczne
systemy monitorowania zagrożeń
pomiary w czasie rzeczywistym
gravimetric analysis
air quality assessment
low-cost optical sensors
systems for risk monitoring
real-time measurements
Opis:
Zgodnie z danymi GUS o zatrudnionych w warunkach zagrożenia na koniec 2019 r., 2. pod względem częstości występowania czynnikiem szkodliwym były pyły, na które narażonych było 50,4 tys. osób (15,9%). Ocena narażenia na pyły w środowisku pracy polega na wykonaniu grawimetrycznych pomiarów stężeń na stanowiskach pracy dla zidentyfikowanych rodzajów pyłów, określeniu wskaźników narażenia na pyły i porównaniu uzyskanych wartości wskaźników narażenia z wartościami najwyższych dopuszczalnych stężeń pyłów. Wadami metody grawimetrycznej jest m.in. brak informacji o zmianach stężenia w czasie, podatność na dodatkowe źródła emisji, długi czas potrzebny na uzyskanie wyniku. Mierniki stężenia pyłów, przedstawiające dane pomiarowe w czasie rzeczywistym lub zbliżonym do rzeczywistego, znajdują coraz więcej zastosowań. Produkowane są już na dużą skalę niskokosztowe, niewielkie sensory, które można stosować do wytwarzania relatywnie dokładnych mierników środowiskowych, a także stacjonarnych i mobilnych sieci sensorowych. Tego typu urządzenia mogą stanowić istotne wsparcie dla grawimetrycznej oceny stężenia pyłów na stanowiskach pracy.
According to the data of the Statistics Poland on employees exposed to the risks arising from work environment at the end of 2019, the second most frequent harmful factor was dust, to which 50,4 thousand people were exposed (15,9%). The assessment of exposure to dust in the work environment consists in performing gravimetric measurements of concentrations at workstations for the identified dust types, determining the dust exposure indicators and comparing the obtained exposure indicator values with the values of the maximum allowable dust concentrations. The disadvantage of the gravimetric method is the lack of information about changes in concentration over time, susceptibility to additional emission sources, long time needed to obtain the result and the inability to conduct continuous monitoring. Dust concentration meters presenting real time or near to real-time measurement data are finding more and more applications in monitoring of the external environment and working environment Small low-cost sensors are already produced on a large scale, which can be used to produce relatively accurate environmental meters, as well as stationary and mobile sensor networks. Such devices are also not without flaws, but they can provide important support for the gravimetric assessment of dust concentration at workstations.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2021, 2; 15-19
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical 3D scanning methods in biological research - selected cases
Metody skanowania optycznego 3D w badaniach biologicznych – opis przypadków
Autorzy:
Paśko, S.
Powiązania:
https://bibliotekanauki.pl/articles/3131489.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
3D scanner
biological research
optical method
algorithm
measurement system
point cloud
marker
data analysis
Źródło:
Acta Scientiarum Polonorum. Zootechnica; 2021, 20, 1; 3-14
1644-0714
Pojawia się w:
Acta Scientiarum Polonorum. Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and evaluation of a needle tip measurement system based on binocular vision
Autorzy:
Lin, Yuyang
Shi, Yunlai
Zhang, Jun
Wang, Fugang
Sun, Haichao
Powiązania:
https://bibliotekanauki.pl/articles/220501.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
needle tip measurement
binocular vision system
measurement capability analysis
non-contact optical positioning
Opis:
The precise location of the needle tip is critical in robot-assisted needle-based percutaneous interventions. An automatic needle tip measuring system based on binocular vision technology with the advantages of non-contact, excellent accuracy and high stability is designed and evaluated. First the measurement requirements of the prostate intervention robot are introduced. A laser interferometer is used as the reference for measuring the position of the needle tip whose relative position variation is described as the needle tip distance in the time domain. The parameters of the binocular cameras are obtained by Zhang’s calibration method. Then a robust needle tip extraction algorithm is specially designed to detect the pixel coordinates of the needle tip without installing the marked points. Once the binocular cameras have completed the stereo matching, the 3D coordinates of the needle tip are estimated. The measurement capability analysis (MCA) is used to evaluate the performance of the proposed system. The accuracy of the system can be controlled within 0.3621 mm. The agreement analysis is conducted by the Bland-Altman analysis, and the Pearson correlation coefficient is 0.999847. The P/T ratio value is 16.42% in the repeatability analysis. The results indicate that the accuracy and stability of the binocular vision needle tip measuring system are adequate to meet the requirement for the needle tip measurement in percutaneous interventions.
Źródło:
Metrology and Measurement Systems; 2020, 27, 3; 495-512
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation research of bionic image intensifier based on the retina structure of elephant-nose fish
Autorzy:
Zhang, Hongxia
Jin, Qingwen
Li, Peng
Jia, Dagong
Liu, Tiegen
Powiązania:
https://bibliotekanauki.pl/articles/1835814.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
geometric optical design
micro-optical device
image analysis
low-light night vision
bionic image intensifier
Opis:
Enhancing image brightness under low light conditions is crucial. The traditional night vision technology depends on the development of photoelectric materials and accurate image processing algorithms. Inspired by the structure of elephant-nose fish, we construct a bionic image intensifier (BII) model. The BII is a planar array based on the concentrating principle of the compound parabolic concentrator (CPC). This solution is based on pure optical design and independent. Through light tracing, the simulation results show that the brightness of the image is improved and good image uniformity is obtained. Quantitative analysis of the geometric concentration ratio (GCR) and the image uniformity is used to optimize CPC structure parameters. At the same time, we also discuss the influence of CPC structural parameters on image continuity, uniformity and geometric concentration ratio. The optimization results are as follows: the input port diameter is 50 μm, the output port diameter is 10 μm, the height is 90 μm, the GCR is 5.61, and the image uniformity is 95.30%. The comprehensive performance of the BII achieves the best.
Źródło:
Optica Applicata; 2020, 50, 4; 551-566
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies