Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "optical analysis" wg kryterium: Temat


Tytuł:
Scanning optical and electron microscopes with computer image acquisition
Autorzy:
Konstankiewicz, K.
Pukos, A.
Powiązania:
https://bibliotekanauki.pl/articles/25623.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
electron microscope
scanning optical microscope
microscopic method
tandem scanning reflected light microscope
computer image analysis
scanning electron microscopy
biological material
rotary microtome
confocal microscopy
Źródło:
International Agrophysics; 1995, 09, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical methods in the grain-size analysis of fine-grained sediments
Autorzy:
Issmer, K.
Powiązania:
https://bibliotekanauki.pl/articles/2059416.pdf
Data publikacji:
2000
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
optical method
grain-size analysis
Kołmogorow-Smirnow non-parametric test
Opis:
Optical methods now dominate the grain-size analysis of fine-grained sediments, because of their rapidity. The growing application of optical methods leads to statistical comparison of their results against those from sedimentation methods. Here, the Kołmogorow-Smirnow non-parametric test is demonstrated. Most agreement exists in the 50-20 and 20-6 mm fraction. In order to compare the optical and the combined methods, correlation ratios were calculated for all commonly used grain-size fractions. Regression equations were established for the 50-20 mm fraction.
Źródło:
Geological Quarterly; 2000, 44, 2; 205-210
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie analizy obrazu w badaniach obiektów i procesów
Aplication of image analyse in object and process investigation
Autorzy:
Mikołajczyk, T.
Powiązania:
https://bibliotekanauki.pl/articles/329088.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
analiza obrazu
pomiary optyczne
rozpoznawanie obrazu
image analysis
optical measure
image recognition
Opis:
W pracy przedstawiono niektóre przykłady zastosowania analizy obrazu do badań obiektów i procesów zrealizowane w Katedrze Inżynierii Produkcji ATR Bydgoszcz. Przy użyciu kamery cyfrowej i specjalnie opracowanego oprogramowania dokonywano pomiarów obiektów na podstawie analizy ich obrazów. Uzyskiwana dokładność pomiaru była wystarczająca do identyfikacji obiektów, a także oceny wymiaru w warunkach warsztatowych. Z zastosowaniem procedur rozpoznawania obrazu dokonywano też oceny obrazów przedmiotów czy też twarzy w oparciu o obrazy zawarte w bazie danych. Przy użyciu sieci neuronowej poszukiwano na obrazie ostrza obrazu jego zużycia.
Aplications to image analyse was presented in this work. With use digital camera was measured the cutting angle of turning tool. Special recognizing procedure was used to object and human face recognize by compare with image in knowledge base. Was short presented special software to area of tool wear recognition with neural network use.
Źródło:
Diagnostyka; 2005, 33; 123-129
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A QMS-compliant multiparameter system for optical inspection of manufactured products
System wieloparametrycznej kontroli wyrobów w procesie produkcji z wykorzystaniem metod optycznej inspekcji przystosowanej do wymagań systemów zarządzania jakością
Autorzy:
Zając, J.
Małkiński, W.
Dworak, M.
Powiązania:
https://bibliotekanauki.pl/articles/256666.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
systemy wizji maszynowej
przetwarzanie obrazów
analiza obrazów
automatyczna inspekcja optyczna
swobodny spadek
akwizycja poruszających się obiektów
baza danych
system zarządzania jakością
machine vision systems
image processing
image analysis
automated optical inspection
free fall
acquisition of moving objects
database
quality management system
Opis:
The system described in this paper provides automated optical inspection of free-falling products. It was designed to inspect plastic nose pads for eyeglasses. The solutions relating to the integrated image acquisition and the processing and analysis techniques allow achieving high inspection efficiency. The system also assures the possibility of full archiving of the inspection results for further reference, processing or statistical analysis.
Opisany w artykule system automatycznej inspekcji optycznej przeznaczony jest do inspekcji jakości swobodnie spadających detali. Zrealizowano aplikację, w której inspekcji podlegają plastikowe noski do okularów. Zastosowane rozwiązania w zakresie akwizycji obrazów oraz technik przetwarzania i analizy umożliwiły uzyskanie dużej wydajności inspekcji. Opracowany system zapewnia również możliwość pełnego archiwizowania wyników inspekcji w celu późniejszego porównywania, przetwarzania czy analizy statystycznej.
Źródło:
Problemy Eksploatacji; 2006, 4; 215-230
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda rejestracji, przetwarzania i analizy obrazu do cyfrowego opisu powierzchni manekina
The method of recording, converting and images analysis for digital model of phantom surface
Autorzy:
Lesiakowska-Jabłońska, M.
Powiązania:
https://bibliotekanauki.pl/articles/151392.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza obrazu
przetwarzanie obrazu
skanowanie 3D
cyfrowe modele obiektów 3D
pomiarowe metody optyczne
images analysis
3D scanning
digital model of 3D objects
optical representation method
Opis:
Zapis powierzchni fantomów - manekinów (stosowanych powszechnie w odzieżownictwie fizycznych modeli budowy ciała ludzkiego o określo-nej uśrednionej charakterystyce wymiarowej) jest konieczny z punktu widzenia prac nad inżynierskimi metodami konstrukcji wykrojów odzieży. Potwierdzają to liczne prace z tego obszaru prowadzone przez szereg placówek naukowych i badawczych świata [1, 2, 3]. Dzięki badaniom prowadzonym w Katedrze Odzieżownictwa PŁ opracowano metodę fotogrametryczną pozwalającą na rejestrację, przetworzenie, analizę, opis cech wymiarowych i odwzorowanie 3D (three dimensional) powierzchni manekinów [4].
Phantom surface representation based on computer analysis of phantom 2D images is a very challenging problem. The representation of phantom surface is necessary for development of engineering techniques for constructing shapes of clothes. The phantoms are widely used in clothing science as a model of human body. This is confirmed by large number of publications from many research institutes [1, 2, 3]. At the Clothing Department, Technical University of Łódź, the new method of digital representation of phantom surface was developed [4]. Thus optical representation method was used to obtain a digital phantom surface model. The indirect method of 3D surface measurement was proposed, where geometrical features of an analysed object were estimated based on analysis of series of its 2D images. The 2D image is a central projection of the analysed object. The most important problem is to register such a projection and then perform an appropriate analysis. To obtain a digital model of objects with size comparable to the human body, the measurement bench was assembled as shown in Fig. 1. This bench contains: analysed object (1); a projector (2) which is a source of two light half-planes (bright and dark); they are projected onto analysed object (1) and are called as "horizontal light half-plane"; a TV camera (9) as a video signal source for the computer (10); it is moved along with a projector during measurement process and it is at an angle ? in relation to light half-plane; two stepper motors (3, 4) with a driving system (5), used to move a camera (with Δζ step) and rotate a phantom (with an angle Δφ); mechanical circuit, which is used to move a camera and a projector; computer (10) used to control whole a system, equipped with two monitors (6, 7), add-on cards and specialised software; vertical reference half-plane, firmly fixed to measure a distance from the analysed object. This measurement bench was used for acquisition and analysis of images of investigated objects.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 44-47
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optyczno-elektroniczny sposób określania składu granulometrycznego gruntów i możliwości zastosowania w geologii inżynierskiej
Optical-electronic way of soil grain size composition determination and its possible application in engineering geology
Autorzy:
Kamiński, S.
Trzciński, J.
Powiązania:
https://bibliotekanauki.pl/articles/184093.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
skład granulometryczny
krzywa uziarnienia
system analizatorów optyczno-elektronicznych
pomiar wielkości cząstek
symulacja analizy sitowej i areometrycznej
analiza kształtu cząstek 3D
grain composition
grains-size distribution
Elsieve - system of optical-electronic analyzers
measurement of particles size
simulation of sieve and sedimentation analysis
3D analysis of particles' shape
Opis:
Obecnie istnieją już techniczne możliwości uniknięcia trudnych manualnie i pracochłonnych pomiarów składu granulometrycznego gruntów (np. analiza sitowa czy areometryczna). Parametr ten można badać za pomocą urządzeń optyczno-elektronicznych typu Elsieve, które coraz powszechniej używane są w Polsce. Takie urządzenia pomiarowe wykorzystuje się do wyznaczenia krzywej granulometrycznej ziaren o wymiarach od 0.5 mim do 100 mm. Dodatkowo istnieje możliwość określenia kształtu ziaren według pomiarów 3D oraz innych parametrów uziarnienia. System pomiarowy może składać się z dowolnej liczby urządzeń połączonych indywidualnie z komputerem rejestrującym. Każdy indywidualny komputer przyrządu pomiarowego połączony jest z komputerem centralnym pełniącym rolę serwera. Stworzona sieć komputerów pozwala jednocześnie rejestrować wyniki pomiarowe na komputerze obsługującym dane urządzenie pomiarowe, jak również na pozostałych komputerach. Taki system pomiarowy jest używany do badań uziarnienia gruntów i innych geomateriałów w laboratorium Instytutu Hydrogeologii i Geologii Inżynierskiej Wydziału Geologii UW.
Nowadays there are available technical possibilities to avoid manually difficult and work-consuming measurements of soil grain composition (e.g. sieve or sedimentation analysis). Such measurements can be replaced by optical-electronic instruments called Elsieve that are more common in Poland. The instruments are used for determination of grain-size distribution of gains and particles with diameter form 0.5 mim to 100 mm. Additionally there is possibility to determine shape of grains by 3D measurements and other graining parameters. The measuring system can consist of any number of instruments, connected with recording computer. Every computer of any measuring instruments is connected with the server. The created network allows to save measuring results at computer that works with particular instrument and at other computers. Such a system is used for measurements of soil and other geomaterials grain composition in laboratory at Institute of Hydrogeology and Engineering Geology, Faculty of Geology, University of Warsaw.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2008, 34, 4; 623-632
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Filters’ Influence on Digital Image Quality in High Temperature Measurements of Surface Properties
Autorzy:
Fabijanska, A
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/108736.pdf
Data publikacji:
2009
Wydawca:
Społeczna Akademia Nauk w Łodzi
Tematy:
digital image processing
image quality
optical filters
image quantitative analysis
image noise
Opis:
This paper is concerned with high temperature image quantitative analysis systems. Particular attention is paid to computerised system for surface properties (wetting angle and surface tension) determination. A brief description of the system is given. The specificity of the performed measurements based on images presenting heat-emitting objects is considered. Moreover, the significance of optical filters’ usage is explained. Infrared and neutral density filters are regarded. Influence of these filters on digital image quality is deliberated. Especially image noise presence is considered. The detailed analysis of noise properties change due filters usage is carried out. Finally, results of the analysis are presented and discussed.
Źródło:
Journal of Applied Computer Science Methods; 2009, 1 No. 2; 53-63
1689-9636
Pojawia się w:
Journal of Applied Computer Science Methods
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zautomatyzowany system kontroli wizyjnej tabletek i kapsułek pakowanych w przezroczyste blistry
Automated optical system for tablets and capsules packaging inspection
Autorzy:
Zając, J.
Małkiński, W.
Wójcik, J.
Karliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/256633.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
wizja maszynowa
inspekcja optyczna
przetwarzanie obrazu
analiza obrazu
inspekcja pakowania
tabletka
kapsułka
system zarządzania jakością
machine vision
optical inspection
image processing
image analysis
tablet
capsule
packaging inspection
quality management system
Opis:
W artykule przedstawiono charakterystykę zautomatyzowanego systemu przeznaczonego do kontroli wizyjnej tabletek i kapsułek pakowanych w przezroczyste blistry. Inspekcja jakości pakowania obejmuje: wykrywanie braku tabletek w gnieździe lub ich nieprawidłowe ułożenie, wykrywanie tabletek o niewłaściwym kolorze lub wymiarach, wykrywanie zanieczyszczeń blistra oraz sprawdzenie prawidłowości oznakowania blistra. Omówiono właściwości podstawowych składników sprzętowych systemu. Zaprezentowano moduły programowe związane z projektowaniem nastaw systemu, tworzeniem nowych zadań inspekcji, a także wizualizacją przebiegu inspekcji w trybie automatycznym. Przedstawiono właściwości i parametry techniczne systemu. Opracowany system umożliwia pełną archiwizację nastaw oraz wyników inspekcji.
The system described in the paper provides automated optical inspection of tablets and capsules packed in transparent blisters. The packaging inspection includes: detection of tablets/capsules presence in nests, detection of improper position of tablets, detection of tablets which have improper color or size, detection of blister contaminations, and marking inspection of blisters. Features of basic hardware components of the system are discussed. Software modules related to projects of system settings, creation of new inspection tasks and visualization of the inspection stream in automatic mode are presented as well. Main features and technical data of the system are described. The system also assures the possibility of full archiving of the inspection settings and results.
Źródło:
Problemy Eksploatacji; 2009, 1; 197-208
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zachowania dynamicznego układu wstęgi papierniczej z wykorzystaniem pomiaru optycznego
Dynamic analysis of paper web with utilization of optical measurement
Autorzy:
Cedrowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/152638.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar optyczny
badania dynamiczne
częstotliwości drgań własnych układu
optical measurement
dynamic analysis
natural frequencies
Opis:
W pracy przedstawiono wyniki analiz dynamicznych drgań płyty wykonanej z tektury falistej. Rezultaty obliczeń teoretycznych częstości drgań własnych płyty, w których wykorzystano model kompozytowy tektury, porównano z wynikami badań doświadczalnych. Do badań doświadczalnych opracowano metodę wyznaczania częstości własnych w oparciu o pomiar optyczny z wykorzystaniem kamery cyfrowej. Ze względu na własności fizyczne materiałów papierniczych, pomiar optyczny jest szczególnie użyteczny przy prowadzeniu badań dynamicznych. Pomiary z użyciem kamery do przebiegów szybkozmiennych pozwalają na wyznaczenie częstości i odpowiadających im postaci drgań z dużą dokładnością.
Theoretical and experimental results of dynamic analysis of rectan-gular plate made of corrugated board were presented in this paper. The composite model of corrugated board was applied to theoretical calculations. In order to determine physical parameters of cardboard, papers of wave from central layers were subjected to homogenization process. Due to the fact that corrugated board and paper have small bending stiffness, a method based on optical measurement of determination the natural frequencies of the plate was used in experimental investigations. Rectangular plate with two straight supported and two free edges was fixed to the vibrating table. Analysis of natural modes enables the observation of vibrations in the vicinity of resonance frequencies. Using optical measurement of fast motion the natural frequency of the plate and amplitudes of vibrations can be measured with high precision. Three films for three different frequencies near the resonance peak are performed to allocate the top of parabola. Optical measurement precisely records dynamic behaviour of the plate made of corrugated board. The introduced results of dynamic investigations show that composite model of corrugated board is not enough precise, especially for higher frequencies.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 905-906
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrooptyczny efekt Kerra w chemii
Electrooptic Kerr effect in chemistry
Autorzy:
Prezhdo, O.
Olan, K.
Zubkowa, W.
Preżdo, W.
Powiązania:
https://bibliotekanauki.pl/articles/171825.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
elektrooptyczny efekt Kerra
analiza konformacyjna
wewnątrzcząsteczkowe oddziaływania
oddziaływania wewnątrzcząsteczkowe
oddziaływania międzycząsteczkowe
polaryzowalność
moment dipolowy
stała Kerra
electro-optical Kerr effect
conformational analysis
intra-molecular interactions
intermolecular interactions
polarizability
dipole moment
Kerr constant
Opis:
The electro-optical Kerr effect finds wide application in conformational analysis of molecules and molecular aggregates [1–5], particularly in cases where the standard X-ray and NMR techniques cannot be used. For instance, NMR allows to establish conformations of linear and cyclic unsaturated organic compounds. However, it is less effective in an analysis of molecular complexes, particularly of those that have several rotational symmetry axes. In such cases a combination of techniques based on molecular dipole moments, electro-optical Kerr effect, optical Kerr effect, IR spectroscopy, and Rayleigh scattering can be applied [6]. The foundations of conformational analysis of molecular complexes using several complementary physical approaches are developed in Ref. [7]. The electro-optical methods are particularly useful for an investigation of intramolecular interactions [8–18]. The strength, direction and other details of intramolecular interactions can be determined by analyzing the deviations of the experimental molar Kerr constant (mK) from its value calculated according to the tensor-additive scheme that operates with polarizability tensors of molecular cores and functional groups [19, 20]. For instance, using this approach it has been shown that weakening of conjugation in an electron donor-acceptor chain can lead to flattening of the molecular structure [21]. The Kerr constant is also very sensitive to intermolecular interactions [22–29]. In order to assess quantitatively an extent of the solvent effect on the mK values, both molecular and continuum models of solution structure have been used [30, 31]. The mK values are greatly affected by the mutual orientation of solvent and solute molecules, which interact by dispersive, inductive and dipole-dipole forces [32]. Hydrogen and donor-acceptor bonding have an even stronger influence on the mK values [33]. The equimolar mixtures approach developed in Ref. [34] allows to determine the molar Kerr constant (mK), dipole moment (m), equilibrium constant (K) and, ultimately, structure of a molecular complex based on measurements of the Kerr constant (B), dielectric permittivity (e), density (d) and refractive index (n) of a series of dilute solutions of the complex. Future trends in the development of the electro-optical methods in chemistry are discussed. Theories that relate the electric-optic proprieties of molecules with their reactivity are particularly important. Such theories should be able to predict the changes in the polarizabilities and dipole moments of bonds, molecules and molecular aggregates during the course of chemical reactions.
Źródło:
Wiadomości Chemiczne; 2011, 65, 1-2; 1-31
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja systemu wizyjnego do monitorowania procesów zgrzewania tarciowego
Concept of the vision system for monitoring of friction stir welding process
Autorzy:
Giesko, T.
Pietras, A.
Mężyk, J.
Kowieski, S.
Powiązania:
https://bibliotekanauki.pl/articles/256857.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
zgrzewanie tarciowe FSW
kontrola jakości
inspekcja optyczna
analiza termograficzna
friction stir welding (FSW)
quality inspection
optical inspection
thermal analysis
Opis:
W artykule zaprezentowano koncepcję metody i systemu do monitorowania procesów zgrzewania tarciowego FSW z wykorzystaniem analizy obrazów w podczerwieni i paśmie widzialnym. Termogramy pokazujące rozkład i zmiany temperatury w obrębie zgrzeiny zawierają kompleksowe informacje o przebiegu procesu zgrzewania tarciowego oraz o strukturze zgrzeiny. Połączona analiza obrazów zgrzeiny, zarejestrowanych za pomocą kamery termowizyjnej i kamery wizyjnej umożliwi monitorowanie on-line procesu zgrzewania tarciowego oraz detekcję wad powierzchniowych i podpowierzchniowych zgrzeiny. W artykule omówiono najważniejsze zagadnienia modelowania systemu wizyjnego i algorytmu inspekcji.
The paper presents the idea of a method and system for monitoring of friction stir welding FSW with the use of analysis of infrared and vision images. Thermal images present a temperature distribution and fluctuation within a weld joint, and contain complex information about welding process and weld structure. The combined analysis of infrared and vision images of weld will enable the on-line process monitoring and detection of surface and subsurface defects. The key aspects of modeling of a vision system and inspection algorithm are described in the paper.
Źródło:
Problemy Eksploatacji; 2011, 4; 91-102
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda optycznej inspekcji w procesie montażu łożysk tocznych
The optical inspection method in the process of assembly of roller bearings
Autorzy:
Czajka, P.
Garbacz, P.
Powiązania:
https://bibliotekanauki.pl/articles/256861.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
inspekcja optyczna
analiza obrazów
detekcja wad
łożysko toczne
optical inspection
image analysis
fault detection
roller bearing
Opis:
W artykule zaprezentowano opracowaną metodę optycznej inspekcji poprawności montażu łożysk tocznych. W celu weryfikacji metody zostało wykonane eksperymentalne stanowisko badawcze. Do kontroli wizyjnej został zastosowany modułowy sterownik wizyjny z monochromatyczną kamerą CCD i oświetlaczem pierścieniowym. Opracowano algorytm detekcji wad, który został zaimplementowany w oprogramowaniu systemu. Zaprezentowano działanie algorytmu z podziałem na poszczególne etapy procesu inspekcji. Opisano zastosowane funkcje z zakresu przetwarzania i analizy obrazów. Przeanalizowano zachowanie algorytmu inspekcji w sy-tuacjach nietypowych, które mogą wystąpić w warunkach przemysłowych. Zaprezentowano przykłady inspekcji łożysk z wykorzystaniem opracowanej metody. Przedstawiono wyniki prób systemu kontroli wizyjnej w warunkach eksploatacyjnych na przemysłowej linii montażu łożysk tocznych.
The article presents the optical inspection method for correct assembly of roller bearings. The experimental research stand was made for verification of the method. The modular vision controller with the monochromatic CCD camera and the ring lighting were used for optical inspection. The algorithm for detecting faults was developed and was implemented in the software of the vision system. The operation of the algorithm was presented for each of the individual stages of inspection process. The applied functions from the field of image processing and analysis were described. The functioning of the inspection algorithm was analysed for untypical situations, which can occur in industry conditions. Examples of bearing inspections, with use of the developed method, were presented. Results of tests of the system for optical inspection were presented in working conditions on the industrial line for assembly of bearings.
Źródło:
Problemy Eksploatacji; 2011, 4; 65-78
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A non-contact laser method based on the imaging and analysis of scattered light used for assessment of surface imperfections
Bezstykowa metoda laserowa wykorzystująca obrazowanie i analizę rozpraszania światła przeznaczona do oceny skaz powierzchni
Autorzy:
Kapłonek, W.
Nadolny, K.
Valicek, J.
Powiązania:
https://bibliotekanauki.pl/articles/153486.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metody optyczne
skaterometria laserowa
przetwarzanie i analiza obrazu
skazy powierzchni
powierzchnia obrobiona
optical methods
laser scatterometry
image processing and analysis
surface imperfections
machined surfaces
Opis:
In the work laser scatterometry supported by image processing and analysis techniques was used for assessment of surface imperfections (SIM) of machined surfaces presented and discussed. During the experiment the ground and polished samples made from aluminium, brass, cast iron and steel, with visible SIM, were used. Surface topographies (Talysurf CLI 2000 - Fig. 1) and images of scattered light (experimental setup - Fig. 2) were acquired for selected areas of those surfaces. Analysis of the data obtained was carried out using Image-ProŽ Plus and TalyMap Silver software (Fig. 3). The results of the experiment enabled us to conclude that the methods used were both useful and could offer an interesting assessment of machine parts characterized by various types of SIM.
Jednym z ważniejszych problemów we współczesnym wytwarzaniu i eksploatacji maszyn oraz urządzeń jest ich odpowiednia diagnostyka. Proces diagnostyczny może dotyczyć m.in. detekcji i analizy skaz powierzchni powstających w sposób niezamierzony lub przypadkowy podczas obróbki, przechowywania lub użytkowania powierzchni części maszyn. Ocena skaz powierzchni może być przeprowadzana z wykorzystaniem szeregu metod pomiarowych. Ważną rolę odgrywają tutaj metody optyczne w największym stopniu wykorzystywane w warunkach produkcyjnych. W pracy pokazano, iż optyczne metody skaterometrii laserowej wspomagane przez techniki przetwarzania i analizy obrazu mogą stanowić ciekawą alternatywę w przypadku oceny części maszyn, charakteryzujących się występowaniem różnego rodzaju skaz powierzchni. W pracy opisano metodę ARS wykorzystującą obrazowanie i analizą światła rozproszonego przeznaczoną do detekcji skaz powierzchni elementów maszyn obrabianych różnymi technikami obróbkowymi. Zaproponowana metoda charakteryzowała się m.in. dużą czułością, bezstykowym sposobem pomiaru oraz krótkim czasemprzeprowadzenia oceny. Parametry uzyskane z analizy obrazu (oprogramowanie Image ProŽ-Plus) porównywano z wybranymi dwu- i trójwymiarowymi mapami powierzchni skaz (oprograowanie TalyMap Silver) rejestrowanymi profilometrem optycznym Talyscan CLI2000 firmy Taylor Hobson. Przeprowadzone badania potwierdziły dużą użyteczność zastosowanej metody rozpraszania światła, mogącej stanowić jedną z propozycji rozwiązania problemu diagnostyki części maszyn i urządzeń w warunkach laboratoryjnych lub
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 6, 6; 554-558
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Analysis of Material and Manufacturing Factors in Riveted Joints Under the Imperja Project
Autorzy:
Szymczyk, E.
Bogusz, P.
Sławiński, G.
Jachimowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/97935.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
riveted joints
fatigue strength
optical methods
SEM analysis
Opis:
The aim of the project was to improve fatigue performance of riveted joints in airframes. Fatigue strength of a joint depends on structural, material and manufacturing factors. The project involved numerical and experimental analysis of material factors and manufacturing imperfections. The paper deals with the analysis of material structure and properties by means of the optical and SE methods. Static monotonic tests for sheet and rivet materials were carried out. ARAMIS optical system was used for the study of deformation and strain fields in the material during loading. This tool offers the possibility of a non-contact measurement with 3D image correlation methods (digital image correlation, DIC) using high-resolution digital CCD cameras. In ductile materials (such as aluminium alloy), subjected to appropriate loading conditions, voids may form, which grow and coalesce leading to crack formation and potential failure. A micro crack may be initiated at the inclusion particles and then voids grow around it. Experimental studies showed that these processes are strongly influenced by hydrostatic stress (Gurson’s material model). SEM analysis of material structure was carried out after performing static tests. In the paper, the authors present the influence of a material model on the results of numerical simulation of the tensile loaded samples with open and riveted holes. The application of Gurson’s material model allows observation of crack growth in the sample cross-section and determination of the sheet rupture as the moment when constraint force decreases to zero (material separation occurs).
Źródło:
Fatigue of Aircraft Structures; 2012, 4; 100-113
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical-Experimental Analysis of Plastic Flow Beginning Phase Round the Hole in the Thin Shield Under Tension
Autorzy:
Bućko, S.
Jodłowski, H.
Trzebicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/387063.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
identyfikacja odkształceń plastycznych
interferencja optyczna
koncentracja naprężeń
badania eksperymentalne
analiza MES
plastic strain identification
optical interference
stress concentration
experimental research
FEM analysis
Opis:
The method of recognition of plastic strains with the use of optical interference was characterized in the work. The idea of the method was shown on the example test for 15HM steel tension. The results of experimental testing of plastic strains initiation in the thin shield with opening of O20 diameter under tension, especially considering round the hole zone were presented in further part of the work. The experiment was carried out with the use of method mentioned above. In the experiment the stresses initializing plastic deformations and the shape of plastic zone were determined. The stress state analysis in the hole zone in the specimen under tension was realized with the use of finite element method. The calculations were done for two significantly different hole diameters. The results of FEM calculations allow for certification that for the holes of diameters significantly bigger than the shield thickness round the hole plane stress state occurs.
Źródło:
Acta Mechanica et Automatica; 2012, 6, 1; 21-25
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies