Tytuł:
Estimating solid contaminant levels in beach sands through petrographic analysis, screening evaluation, and optical imaging
Autorzy:
Kuś, Sebastian
Jelonek, Zbigniew
Jelonek, Iwona
Sierka, Edyta
Powiązania:
https://bibliotekanauki.pl/articles/27311567.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
beach
optical analysis
petrographic analysis
solid pollution
Opis:
Determining the level of solid pollution in beach sands located near artificial inland water bodies in order to maintain high safety standards is a difficult and expensive task. The tests aimed at determining beach pollution caused by solid wastes through analysis of toxic and chemical concentrations, are time-consuming and usually require several days before the results are available. In addition, the maintenance of the beach area involving beach raking or grooming, and the seasonal replenishment of sand makes it difficult to realistically determine the chemical or bacterial contamination of the tested material. Solid pollutants, such as glass, caps, cans, thick foil, metal, and plastic fragments, pose a greater health risk to beachgoers. The above-mentioned pollutants, especially small ones, are hardly visible on the surface or they are buried at shallow depths. Beach garbage poses a serious threat that can lead to infections from cuts and scratches. These injuries can become infected, further jeopardizing the health and lives of beachgoers due to risks like tetanus, staphylococcus, etc. The authors presented a new petrographic method aimed at assessing the quality of sand by examining the content of solid pollutants. The obtained results allowed us to conclude that the mentioned procedure can be used for a quick quantitative estimation of the content of potentially dangerous and undesirable pollutants in beach sands. Consequently, the method implemented to determent the amount of solid pollutants in beach sands has proven to be a valuable tool for recreational facility administrators, helping them in taking necessary measures to ensure the safety of beach users. Petrographic analysis of beach sands revealed the presence of pollutants of plant origin (0.4–1.8%), plastic (0.1–0.4%), paper (0.1–0.6%), charcoal (0.1–0.5%), glass (0.1–0.4%), metals (0.1–0.4%), rust (0.1–0.3%), ash and slag (0.1–0.3%), and fossil coals (0.1–0.2%).
Źródło:
Archives of Environmental Protection; 2023, 49, 3; 50--63
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geometrical and optical analysis of small-sized parabolic trough collector using ray tracing tool SolTrace
Autorzy:
Singh, Raman Kumar
Chandra, Prakash
Powiązania:
https://bibliotekanauki.pl/articles/27312206.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
parabolic trough collector
SolTrace
Monte Carlo ray tracing method
nonuniform heat flux distribution
optical analysis
geometrical analysis
Opis:
The present work is aimed at geometrical optimization and optical analysis of a small-sized parabolic trough collector (PTC). Improving the performance of parabolic trough collectors can greatly justify the use of solar energy. An optimized curvature geometry, the location of the absorber tube, and the heat flux distribution along the circumference of the absorber tube are major features in the geometric optimization and optical modelling of parabolic trough collectors. Rim angle, aperture width, the diameter of the absorber tube, receiver position, and the optimum value of heat flux are the major parameters considered in this work for geometrical and optical analysis. The Monte Carlo ray tracing method has been adopted for analysis. The non-uniform heat flux distribution profile obtained from optical analysis of the proposed parabolic trough collector has been compared with the profile available in the literature, and good agreement has been obtained, which proves the feasibility and reliability of the model and method used for this study. An experimental new small-sized parabolic trough collector has been fabricated for the optimized rim angle of 90 deg after a successful laser light feasibility test. The effect of the absorber tube position along the optical axis on the heat flux profile was analysed and found to be substantial. Furthermore, the sensitivity analysis of the parabolic trough collector using the software applied has been discussed separately.
Źródło:
Archives of Thermodynamics; 2023, 44, 3; 35--61
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distribution of EC and OC temperature fractions in different research material
Dystrybucja frakcji temperaturowych EC i OC w różnych materiałach badawczych
Autorzy:
Błaszczak, Barbara
Mathews, Barbara
Słaby, Krzysztof
Klejnowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27311564.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
wet deposition
carbonaceous matter
fine PM
thermal-optical analysis
mokra depozycja
analiza termooptyczna
materia węglowa
próbki węgla
Opis:
The aim of the study was to assess the profile of EC (elemental carbon) and OC (organic carbon) temperature fractions in PM1 and PM2.5 samples and in wet deposition samples (material collected on a filter). The research was conducted at the urban background station in Zabrze (southern Poland) in the period of Oct 2020–Oct 2021. PM samples were collected with high-volume samplers; the automatic precipitation collector NSA 181 by Eigenbrodt was used to collect the deposition samples. Concentrations of EC and OC were determined using thermal-optical method (carbon analyzer from Sunset Laboratory Inc., “eusaar_2” protocol). Regardless of the type of research material, organic carbon constituted the dominant part of the carbonaceous matter, and this dominance was more visible in the non-heating season. The profile of temperature fractions of OC and EC was clearly different for dust washed out by precipitation. Noteworthy is a much lower content of pyrolytic carbon (PC) in OC, which can be explained by the fact that PC is most often combined with the water soluble organic carbon. In addition, a high proportion of the OC3 fraction was observed, followed by OC4, which may indicate that these fractions are of a more regional origin. With regard to the EC fractions, the differences are less visible and concern, in particular, the higher share of EC4 and the lower of EC2. The obtained results may be a valuable source of information about the actual status of the carbonaceous matter and its transformation in the atmosphere .
Celem badań była ocena profilu frakcji temperaturowych EC (węgiel elementarny) i OC (węgiel organiczny) w próbkach PM1 i PM2,5 oraz w próbkach depozycji mokrej (materiał zgromadzony na sączku). Badania przeprowadzono na stacji tła miejskiego w Zabrzu w okresie X 2020–X 2021. Próbki PM pobierano za pomocą poborników wysoko-objętościowych. Do poboru próbek depozycji zastosowano automatyczny kolektor opadów NSA 181 firmy Eigenbrodt. Stężenia EC i OC oznaczono metodą termiczno-optyczną (analizator węgla firmy Sunset Laboratory Inc., protokół „eusaar_2”). Niezależnie od rodzaju materiału badawczego węgiel organiczny stanowił dominującą część materii węglowej, a dominacja ta była bardziej widoczna w sezonie niegrzewczym. Profil frakcji temperaturowych OC i EC różnił się wyraźnie dla pyłu z depozycji mokrej. Na uwagę zasługuje znacznie niższa zawartość węgla pirolitycznego (PC) w OC, co można tłumaczyć tym, że PC jest najczęściej łączony z rozpuszczalnym w wodzie węglem organicznym. Ponadto zaobserwowano wysoki udział frakcji OC3, a następnie OC4, co może wskazywać na bardziej regionalne pochodzenie tych frakcji. W przypadku frakcji EC różnice są mniej widoczne i dotyczą w szczególności wyższego udziału EC4 i mniejszego EC2. Uzyskane wyniki mogą być cennym źródłem informacji o materii węglowej i przemianom jakim podlega w atmosferze.
Źródło:
Archives of Environmental Protection; 2023, 49, 2; 95--103
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectral analysis for tilted fiber Bragg gratings in the corrosion detection for concrete structure
Autorzy:
Kwong, Kok Zee
Udos, Waldo
Lim, Kok-Sing
Lee, Foo Wei
Tan, Chee Ghuan
Samion, Muhamad Zharif
Ahmad, Harith
Powiązania:
https://bibliotekanauki.pl/articles/2172827.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tilted fibre Bragg grating
optical spectral analysis
Fourier transform
corrosion
steel bar
Opis:
An effective corrosion monitoring technique is sought after by the engineers for assessing the steel bar corrosion at the early stage for the maintenance and repair works, especially in the corrosive environments, such as coastal and marine. In this work, tilted fiber Bragg grating (TFBG) with the optical sensor is employed in corrosion monitoring of a reinforced concrete structure. Taking advantage of the high sensitivity of TFBG cladding resonance wavelengths to the change in the surrounding medium, the sensor is mounted on the steel bar that is embedded in a concreted block during an accelerated corrosion process. The acquired transmission spectrum of the TFBG during the procedure is digitally processed using Fourier Transform to produce an index that is sensitive to the generated corrosion product surrounding the TFBG sensor. This eases the analysis of the sophisticated TFBG transmission spectra. The generated index can be used as an indicator (indicator J ) for the corrosion process of the embedded steel bar in the concrete structure. This indicator J can act as an indicator to describe the corrosion activity and corrosion level at a specific point of the steel bar in concrete structures.
Źródło:
Optica Applicata; 2022, 52, 3; 429--439
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study on combustion characteristics of lean premixed CH4/air mixtures in RCM using spark ignition and turbulent jet ignition in terms of orifices angular position change
Autorzy:
Bueschke, Wojciech
Skowron, Maciej
Wisłocki, Krzysztof
Szwajca, Filip
Powiązania:
https://bibliotekanauki.pl/articles/973119.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
CNG
turbulent jet ignition
prechamber
optical analysis
flame development
heat release rate
turbulentny zapłon odrzutowy
komora wstępna
analiza optyczna
szybkość wydzielania ciepła
Opis:
The increase in ignitability consist a main aim of implementation of the turbulent jet ignition (TJI) in relation to the combustion of diluted charges. Such an ignition system has been introduced to the lean-burn CNG engine in the scope of GasOn-Project (Gas Only Internal Combustion Engines). In this study the impact of TJI application on the main combustion indexes has been investigated using RCM and analyzed on the bases of the indicating and optical observations data. The images have been recorded using LaVision HSS5 camera and post-processed with Davis software. Second part of the study based on indicating measurements consist the analysis of combustion regarding the variation in the geometry of pre-chamber nozzles. It has been noted, that combustion with TJI indicates significantly bigger flame luminescence and simultaneously - faster flame front development, than the combustion initiated with conventional SI. The positive impact of nozzles angular position on engine operational data has been found in the static charge movement conditions, regarding the combustion stability.
Źródło:
Combustion Engines; 2019, 58, 1; 36-41
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza termiczna – interpretacja krzywych. Cz. 4, Pomiary TGA
Autorzy:
Schulnell, M.
Powiązania:
https://bibliotekanauki.pl/articles/273952.pdf
Data publikacji:
2016
Wydawca:
Roble
Tematy:
analiza termiczna
analiza termograwimetryczna
TGA
skaningowa kalorymetria różnicowa
DSC
analiza termomechaniczna
TMA
dynamiczna analiza mechaniczna
DMA
analiza termooptyczna
TOA
thermal analysis
thermogravimetric analysis
differential scanning calorimetry
thermomechanical analysis
dynamic mechanical analysis
thermal-optical analysis
Opis:
W artykule omówiono różne kwestie odnoszące się do pomiarów TGA. Wykazano również, że inne techniki analizy termicznej takie jak różnicowa kalorymetria skaningowa (DSC), analiza termomechaniczna (TMA), dynamiczna analiza mechaniczna (DMA) i analiza termooptyczna (TOA) mogą w istotny sposób ułatwiać interpretację wyników pomiarów TGA.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2016, 21, 4; 6-13
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia zawodowego na węgiel elementarny w zakładach stosujących maszyny i urządzenia z silnikami wysokoprężnymi
Assessment of occupational exposure to elemental carbon in plants using diesel machinery and equipment
Autorzy:
Szewczyńska, Małgorzata
Kowalska, Joanna
Pośniak, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2188905.pdf
Data publikacji:
2023-05-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
narażenie zawodowe
ocena narażenia
węgiel elementarny
spaliny silników wysokoprężnych
analiza termo-optyczna
marker spalin Diesla
occupational exposure
exposure assessment
elemental carbon
diesel exhaust
thermo-optical analysis
diesel exhaust marker
Opis:
Wstęp W artykule przedstawiono i omówiono wyniki oznaczania węgla elementarnego (elemental carbon – EC) emitowanego w spalinach silników Diesla (SSD) do powietrza stanowisk pracy, na których były wykorzystywane maszyny i urządzenia z takimi silnikami. Narażenie zawodowe na EC jako marker SSD oceniono, obejmując pomiarami 51 naziemnych stanowisk pracy z obsługą lub konserwacją silników Diesla. Przeprowadzono również pomiary na 9 stanowiskach pracy w kopalniach niewęglowych. Materiał i metody Do pobierania próbek powietrza na stanowiskach pracy maszyn i urządzeń emitujących SSD zlokalizowanych na powierzchni do oznaczania EC wykorzystano próbnik kasetowy bez impaktora z filtrem kwarcowym, a w przypadku pomiarów w kopalniach niewęglowych – próbnik do frakcji respirabilnej typu Higgins-Dewell Cyclone FH022. Do oznaczania EC zastosowano metodę analizy termo-optycznej węgla z wykorzystaniem detektora płomieniowo-jonizacyjnego. Wyniki Analiza wyników pomiarów na stanowiskach pracy zlokalizowanych na powierzchni, tj. w warsztatach samochodowych i hucie stali, wykazała, że największe stężenia EC występowały na stanowiskach pracy związanych z obsługą starych wózków widłowych. Oznaczone tam stężenia EC wynosiły, odpowiednio, 353 μg/m³ i 78 μg/m³. W kopalniach niewęglowych stężenie EC wynosiło natomiast 7,5–50 μg/m³. Wnioski Ocena narażenia na badanych stanowiskach w hucie stali wykazała największe, 7-krotne, przekroczenie najwyższego dopuszczalnego stężenia (NDS) na stanowisku operatora spalinowego wózka widłowego. Na pozostałych badanych stanowiskach pracy w warsztatach samochodowych oznaczone stężenia wynosiły 0,1–0,5 NDS lub <0,1 NDS. W kopalniach niewęglowych oznaczone stężenia odpowiadały natomiast 0,12–1 krotności NDS. Med. Pr. 2023;74(2)
Background This paper presents and discusses the results of the determination of elemental carbon emitted in diesel engine exhaust into the air of workplaces where machines and equipment with diesel engines are used. In order to assess occupational exposure to elemental carbon (EC) as a marker of exhaust gases emitted by diesel engines, 51 ground-based workplaces where people who operate or maintain equipment with this type of engine work were measured. Measurements were also carried out at 9 workplaces in non-coal mines. Material and Methods For air sampling at workplaces of diesel exhaust emitting machines and equipment located on the surface, a cartridge sampler without an impactor with a quartz filter was used for elemental carbon determination, while for measurements in non-coal mines the Higgins-Dewell Cyclone FH022 respirable fraction sampler was used. The thermo-optical carbon analysis method using a flame ionisation detector was used to determine elemental carbon. Results Analysis of the results of the determined elemental carbon concentrations at workplaces located on the ground, i.e., in car repair shops, and in the steelworks where combustion forklifts are operated, showed that the highest concentrations of elemental carbon were determined at the old forklift workplaces in the steelworks. The determined EC concentrations at these workstations were 353 μg/m³ and 78 μg/m³, respectively. In the non-coal mines, elemental carbon concentrations were in the range of 7.5–50 μg/m³. Conclusions Exposure assessment at the surveyed workplace in the steelworks showed the highest 7-fold exceedance of the maximum admissible concentration (MAC) at the position of the combustion forklift operator. At the other surveyed workplaces in the car repair shop the marked concentrations were in the range of 0.1–0.5 MAC or <0.1 MAC. In non-coal mines, the determined concentrations ranged 0.12–1 times the MAC. Med Pr. 2023;74(2)
Źródło:
Medycyna Pracy; 2023, 74, 2; 93-102
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shape accuracy in single point incremental forming of conical frustums from titanium CP2 sheets
Dokładność kształtu w jednopunktowym kształtowaniu przyrostowym stożków ściętych z blach tytanowych CP2
Autorzy:
Szpunar, Marcin
Balcerzak, Maciej
Żaba, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2204384.pdf
Data publikacji:
2022
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
incremental sheet forming
titanium
springback
optical forming analysis
X-ray tomography
kształtowanie przyrostowe blach
tytan
sprężynowanie
analizy optyczne kształtowania
tomografia komputerowa
Opis:
This paper presents frustum cone drawpiece analysis made of titanium CP2 sheet by a single incremental sheet forming. Central composite design has been adopted to carry out an experiment containing 20 runs, then multi-criteria parameter optimization has been done. Optimal parameters have been validated and responses deviations do not exceed 4% compared to created models. For the drawpiece formed with optimal parameters, AGRUS optical measurement and X-ray tomography has been applied to check the obtained of the part wall thickness and general deviations compared to the CAD model. The wall angle discrepancy of the cone generatrix has also been analyzed. No gaps or ruptures have been confirmed by X-ray. The blank rolling direction has a significant effect on the drawpiece deviations. The measurement results showed deviations of the drawpiece wall angle +0.27°/- 0.06°, sheet thickness on the cone +0.012/-0.04 mm and +0.151/-0.096 mm from the reference CAD geometry.
W pracy przedstawiono analizę wytłoczek w kształcie stożka ściętego wykonanego z blachy tytanowej CP2 metodą jednopunktowego przyrostowego kształtowania. Do przeprowadzenia eksperymentu obejmującego 20 przebiegów przyjęto centralny plan kompozycyjny, następnie dokonano wielokryterialnej optymalizacji parametrów. Dokonano walidacji optymalnych parametrów, a uzyskane wyniki nie przekraczają 4% w odniesieniu do stworzonych modeli. Dla wytłoczki uformowanej z optymalnymi parametrami zastosowano pomiar optyczny AGRUS oraz tomografię rentgenowską w celu sprawdzenia uzyskanej grubości ścianki wytłoczki i odchyłek w porównaniu z modelem CAD. Przeanalizowano również rozbieżność kątów ścian tworzących stożka. Za pomocą skanu rentgenowskiego potwierdzono brak szczelin i pęknięć wytłoczki. Kierunek walcowania półfabrykatu ma istotny wpływ na odchyłki. Wyniki pomiarów wykazały odchylenia kąta ścianki wytłoczki +0,27/-0,06°, grubości ścianki na stożku +0.012/-0.04 mm oraz +0.151/-0.096 mm od geometrii referencyjnej CAD.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2022, z. 94; 63--75
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the optode array representation using optical properties at systole and diastole
Autorzy:
Jumadi, N A
Beng, G K
Mohd-Ali, M. A.
Zahedi, E
Powiązania:
https://bibliotekanauki.pl/articles/173805.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical simulation
optical properties
optode array
semi-infinite tissue layer
statistical
analysis
Opis:
The necessity to develop an optode array in order to probe the fetus oxygenation noninvasively regardless of the fetus position has been highlighted in previous literature. In this paper, a series of optical simulations are carried out to determine the best representation of optode array by using optical properties at systolic and diastolic states. The selection is based on the highest flux values accumulated at respective detectors. To accomplish the objective, a homogenous three-layer semi-infinite tissue model is implemented to represent the pregnant woman model. The geometry of the model as well as Monte Carlo simulation are carried out using commercial software, whereas the optical properties related to systolic and diastolic states are defined for all wavelengths. A statistical noise analysis is also introduced in order to find a sufficient number of rays to be launched into the optical tissue system.
Źródło:
Optica Applicata; 2013, 43, 4; 747-759
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Separation of isochromatics and isoclinics phasemaps for the photoelastic technique with use phase shifting and a large number of high precision images
Autorzy:
Magalhaes, C. A.
Neto, P. S.
Magalhaes Jr P. A., A.
de Barcellos, C. S.
Powiązania:
https://bibliotekanauki.pl/articles/220820.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photoelasticity
metrology
stress analysis
strain measurement
optical measurement systems
optical interferometry
experimental techniques
Opis:
Digital photoelasticity is an important optical metrology follow-up for stress and strain analysis using full-field digital photographic images. Advances in digital image processing, data acquisition, procedures for pattern recognition and storage capacity enable the use of the computer-aided technique in automation and facilitate improvement of the digital photoelastic technique. The objective of this research is to find new equations for a novel phase-shifting method in digital photoelasticity. Some innovations are proposed. In terms of phaseshifting, only the analyzer is rotated, and the other equations are deduced by applying a new numerical technique instead of the usual algebraic techniques. This approach can be used to calculate a larger sequence of images. Each image represents a pattern and a measurement of the stresses present in the object. A decrease in the mean errors was obtained by increasing the number of observations. A reduction in the difference between the theoretical and experimental values of stresses was obtained by increasing the number of images in the equations for calculating phase. Every photographic image has errors and random noise, but the uncertainties due to these effects can be reduced with a larger number of observations. The proposed method with many images and high accuracy is a good alternative to the photoelastic techniques.
Źródło:
Metrology and Measurement Systems; 2013, 20, 1; 127-138
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative accuracy analysis of triangulated surface models of a fossil skull digitized with various optic devices
Autorzy:
Garashchenko, Yaroslav
Kogan, Ilja
Rucki, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/2052109.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Madygenerpeton
optical measurement
triangulated model
polygonal analysis
accuracy
Opis:
Digital metrology was applied for evaluate 3D models of the unique skull of a fossil tetrapod, Madygenerpeton pustulatum, generated using various 3D digitization methods. The skull surface is covered by minute tubercles making it challenging for digitization with appropriate accuracy. Uniqueness and fragility of the specimen preclude the use of tactile measuring systems for creating a standardized reference model. To overcome this problem, comparative analysis of the triangulated models generated from the clouds of points obtained with seven different devices was conducted using the Geomagic Studio and Autodesk PowerShape CAD software. In the proposed approach, geometrically and dimensionally closest-fitting models underwent detailed statistical analysis between surface polygons in three steps. First, 3D models obtained from different scanning methods were compared with each other in couples. Next, statistical analysis of the differences between the coupled models was performed. Finally, a rating list of the models related to the required accuracy was prepared. The proposed approach is applicable to any other scanned object, especially in palaeontological applications, where each object is unique and exhibits individual features.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 37-51
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectral analysis by a video camera in a holographic optical tweezers setup
Autorzy:
Drobczynski, S
Dus-Szachniewicz, K
Symonowicz, K.
Glogocka, D
Powiązania:
https://bibliotekanauki.pl/articles/174701.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
holographic optical tweezers
power spectrum density
video analysis
Opis:
We discuss the basic parameters of the holographic tweezers equipped with a diode laser and cheap video camera. We compare these parameters with the system using a fast camera and high power Nd:YAG laser. The measured parameters are: the power spectra density calculated from tracing the position of the micron polystyrene beads and the trap stiffness. We show that this cheap optical tweezers system is sufficient for experiments in microbiology.
Źródło:
Optica Applicata; 2013, 43, 4; 739-746
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Analysis of Material and Manufacturing Factors in Riveted Joints Under the Imperja Project
Autorzy:
Szymczyk, E.
Bogusz, P.
Sławiński, G.
Jachimowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/97935.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
riveted joints
fatigue strength
optical methods
SEM analysis
Opis:
The aim of the project was to improve fatigue performance of riveted joints in airframes. Fatigue strength of a joint depends on structural, material and manufacturing factors. The project involved numerical and experimental analysis of material factors and manufacturing imperfections. The paper deals with the analysis of material structure and properties by means of the optical and SE methods. Static monotonic tests for sheet and rivet materials were carried out. ARAMIS optical system was used for the study of deformation and strain fields in the material during loading. This tool offers the possibility of a non-contact measurement with 3D image correlation methods (digital image correlation, DIC) using high-resolution digital CCD cameras. In ductile materials (such as aluminium alloy), subjected to appropriate loading conditions, voids may form, which grow and coalesce leading to crack formation and potential failure. A micro crack may be initiated at the inclusion particles and then voids grow around it. Experimental studies showed that these processes are strongly influenced by hydrostatic stress (Gurson’s material model). SEM analysis of material structure was carried out after performing static tests. In the paper, the authors present the influence of a material model on the results of numerical simulation of the tensile loaded samples with open and riveted holes. The application of Gurson’s material model allows observation of crack growth in the sample cross-section and determination of the sheet rupture as the moment when constraint force decreases to zero (material separation occurs).
Źródło:
Fatigue of Aircraft Structures; 2012, 4; 100-113
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel rogue optical network unit detection algorithm for gigabit passive optical networks
Autorzy:
Horvath, T.
Munster, P.
Dubravec, L.
Filka, M.
Powiązania:
https://bibliotekanauki.pl/articles/174637.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gigabit passive optical network
GPON
rogue optical network unit
ONU
data analysis
detection algorithm
Opis:
Passive optical networks are widely used as a promising solution for future access networks. Currently, the bandwidth is still increasing which means the current copper networks are not able to transfer new services such as 4K video, live streaming, etc. In other words, they reached their capacity limit. The passive optical networks rely on point-to-multipoint technology. That means each customer uses a share medium by time slots. Each time slot exactly specifies who and when is able to transfer data. In general, this control mechanism is implemented in the optical network unit by worst transmission convergence layer. On the other hand, there are cases when the optical network unit (it is called rogue optical network unit) does not follow instructions provided by the optical line termination, for example, if an attacker modifies a firmware of the end unit and/or when the control protocol is not loaded properly inside optical network unit. In worst case, the optical network unit transmits data in a continual mode (other optical network units cannot send data). Thestandard defines finding of the rogue optical network unit but it does not specify how the rogue optical network unit should be allocated because the frames of the rogue optical network unit do not contain the proper parameters. We realized a measurement in a real network with the rogue optical network unit and then we analyzed the captured data. A new algorithm for the rogue optical network unit allocation is presented. We do not consider any modification of the transmission convergence layer in gigabit passive optical networks.
Źródło:
Optica Applicata; 2016, 46, 3; 421-433
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation research of bionic image intensifier based on the retina structure of elephant-nose fish
Autorzy:
Zhang, Hongxia
Jin, Qingwen
Li, Peng
Jia, Dagong
Liu, Tiegen
Powiązania:
https://bibliotekanauki.pl/articles/1835814.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
geometric optical design
micro-optical device
image analysis
low-light night vision
bionic image intensifier
Opis:
Enhancing image brightness under low light conditions is crucial. The traditional night vision technology depends on the development of photoelectric materials and accurate image processing algorithms. Inspired by the structure of elephant-nose fish, we construct a bionic image intensifier (BII) model. The BII is a planar array based on the concentrating principle of the compound parabolic concentrator (CPC). This solution is based on pure optical design and independent. Through light tracing, the simulation results show that the brightness of the image is improved and good image uniformity is obtained. Quantitative analysis of the geometric concentration ratio (GCR) and the image uniformity is used to optimize CPC structure parameters. At the same time, we also discuss the influence of CPC structural parameters on image continuity, uniformity and geometric concentration ratio. The optimization results are as follows: the input port diameter is 50 μm, the output port diameter is 10 μm, the height is 90 μm, the GCR is 5.61, and the image uniformity is 95.30%. The comprehensive performance of the BII achieves the best.
Źródło:
Optica Applicata; 2020, 50, 4; 551-566
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical methods in the grain-size analysis of fine-grained sediments
Autorzy:
Issmer, K.
Powiązania:
https://bibliotekanauki.pl/articles/2059416.pdf
Data publikacji:
2000
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
optical method
grain-size analysis
Kołmogorow-Smirnow non-parametric test
Opis:
Optical methods now dominate the grain-size analysis of fine-grained sediments, because of their rapidity. The growing application of optical methods leads to statistical comparison of their results against those from sedimentation methods. Here, the Kołmogorow-Smirnow non-parametric test is demonstrated. Most agreement exists in the 50-20 and 20-6 mm fraction. In order to compare the optical and the combined methods, correlation ratios were calculated for all commonly used grain-size fractions. Regression equations were established for the 50-20 mm fraction.
Źródło:
Geological Quarterly; 2000, 44, 2; 205-210
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie zintegrowanych systemów CAD/CMM/RP do oceny wielkości rzeczywistych odkształceń na przykładzie prototypu szczęki chwytaka
Autorzy:
Dziubek, T.
Budzik, G.
Sobolewski, B.
Petranik, M.
Powiązania:
https://bibliotekanauki.pl/articles/314463.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
skaner optyczny
PolyJet
CAD
analiza odkształceń
optical scanner
deformation analysis
Opis:
W artykule przedstawiono badania dotyczące określenia wielkości odkształceń prototypu szczęki chwytaka, wykonanej z zastosowaniem addytywnej metody wytwarzania, PolyJet. W tym celu zamodelowano z systemie CAD geometrię testową, którą poddano analizom MES, mającym numerycznie określić wielkości odkształceń przedmiotu podczas jego pracy. W celu weryfikacji poprawności otrzymanych wyników numerycznych, wykonano stanowisko badawcze, umożliwiające symulację rzeczywistych warunków pracy szczęki. Po zamocowaniu prototypu na stanowisku badawczym, został on obciążony analogiczne jak w analizach MES. Obciążony statycznie i odpowiednio przygotowany prototyp, poddano procesowi pomiarowemu, wykonanemu z zastosowaniem optycznego skanera 3D Atos II Triple Scan. Przeprowadzono również pomiar geometrii szczęki bez obciążenia. Na podstawie otrzymanych danych pomiarowych wykonano analizy deformacji prototypu pod obciążeniem, jak również określono dokładność wykonania jego geometrii w odniesieniu do nominalnego modelu 3D-CAD. Przeprowadzone badania umożliwiają precyzyjne określenie modyfikacji geometrii modeli fizycznych w celu zapewnienia jak największej wytrzymałości części, przy jednoczesnej minimalizacji masy. Równocześnie wykonane analizy pozwalają na weryfikacje danych materiałowych przyjętych symulacji MES oraz możliwość ich korekty, w porównaniu do warunków rzeczywistych.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 10; 48-52
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-agent parallel implementation of VLSI CAD procedures
Autorzy:
Doudkin, A. A.
Petrovsky, A. I.
Otvagin, A V.
Sadyhov, R. Kh.
Powiązania:
https://bibliotekanauki.pl/articles/335739.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
manufacturing
software
parallel application models
graph models
optical inspection
image analysis
Opis:
The integrated framework for parallel processing of data describing integrated circuits layouts that based on a graphoriented parallel algorithm representation is represented. A parallel program is developed from single computational units (grains) in specialized visual editor. This visual schema is translated into XML form that is interpreted by multi agent runtime system, based on a MPI library. The runtime system realizes a dynamic optimization of parallel computations with the algorithm of virtual associative network. The proposed tools are well suited for rapid development, analysis and execution of parallel algorithms with adaptation to specific cluster architecture.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2013, 58, 1; 35-38
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental analysis by measurement of surface roughness variations in turning process of duplex stainless steel
Autorzy:
Krolczyk, G. M.
Legutko, S.
Powiązania:
https://bibliotekanauki.pl/articles/220659.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
turning
coatings
friction-reducing
optical microscopy
surface roughness analysis and models
Opis:
The objective of the investigation was to identify surface roughness after turning with wedges of coated sintered carbide. The investigation included predicting the average surface roughness in the dry machining of Duplex Stainless Steel (DSS) and the determination of load curves together with roughness profiles for various cutting conditions. The load curves and roughness profiles for various cutting wedges and variable cutting parameters were compared. It has been shown that dry cutting leads to a decrease in friction for lubricated surfaces, providing a small initial contact area where the surface is contacted. The study has been performed within a production facility during the production of electric motor parts and deep-well pumps.
Źródło:
Metrology and Measurement Systems; 2014, 21, 4; 759-770
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Filters’ Influence on Digital Image Quality in High Temperature Measurements of Surface Properties
Autorzy:
Fabijanska, A
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/108736.pdf
Data publikacji:
2009
Wydawca:
Społeczna Akademia Nauk w Łodzi
Tematy:
digital image processing
image quality
optical filters
image quantitative analysis
image noise
Opis:
This paper is concerned with high temperature image quantitative analysis systems. Particular attention is paid to computerised system for surface properties (wetting angle and surface tension) determination. A brief description of the system is given. The specificity of the performed measurements based on images presenting heat-emitting objects is considered. Moreover, the significance of optical filters’ usage is explained. Infrared and neutral density filters are regarded. Influence of these filters on digital image quality is deliberated. Especially image noise presence is considered. The detailed analysis of noise properties change due filters usage is carried out. Finally, results of the analysis are presented and discussed.
Źródło:
Journal of Applied Computer Science Methods; 2009, 1 No. 2; 53-63
1689-9636
Pojawia się w:
Journal of Applied Computer Science Methods
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deformation measurement system for UAV components to improve their safe operation
Autorzy:
Czyż, Zbigniew
Jakubczak, Patryk
Podolak, Piotr
Skiba, Krzysztof
Karpiński, Paweł
Droździel-Jurkiewicz, Magda
Wendeker, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/28328271.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
strength tests
deformation measurement
optical displacement
deformation analysis
digital image correlation
UAV
Opis:
The paper presents the authors’ method and test rig for performing the deformation analysis of unmanned aircraft fuselages. To conduct the analysis, the DIC system was used, as well as a test rig designed and constructed by the authors, equipped with a dedicated control and load control system. The article presents a description of the research capabilities of the test rig developed for testing the deformation of unmanned aircraft fuselages. Due to the specific operating conditions of the designed fuselage,the test rig developed allows the simulation of loads corresponding to different flight conditions. In addition, it is possible to change the forces acting on the fuselage simultaneously for all servos or each of them separately. Finally, results showing the displacement of component control points for the considered fuselage versions are presented. The tests carried out using the developed test rig allowed the verification of the maximum deformations. The two versions of the composite fuselage of an aerial vehicle have been compared in the paper. The created measurement system and performed analyzes have enabled us to identify and quantitatively analyze the weaknesses of the construction. The results have enabled us to geometrically modify the constructionso the mass of the fuselage reduced by 19% and a coefficient of construction balance increased by 22%.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 4; art. no. 172358
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie analizy obrazu w badaniach obiektów i procesów
Aplication of image analyse in object and process investigation
Autorzy:
Mikołajczyk, T.
Powiązania:
https://bibliotekanauki.pl/articles/329088.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
analiza obrazu
pomiary optyczne
rozpoznawanie obrazu
image analysis
optical measure
image recognition
Opis:
W pracy przedstawiono niektóre przykłady zastosowania analizy obrazu do badań obiektów i procesów zrealizowane w Katedrze Inżynierii Produkcji ATR Bydgoszcz. Przy użyciu kamery cyfrowej i specjalnie opracowanego oprogramowania dokonywano pomiarów obiektów na podstawie analizy ich obrazów. Uzyskiwana dokładność pomiaru była wystarczająca do identyfikacji obiektów, a także oceny wymiaru w warunkach warsztatowych. Z zastosowaniem procedur rozpoznawania obrazu dokonywano też oceny obrazów przedmiotów czy też twarzy w oparciu o obrazy zawarte w bazie danych. Przy użyciu sieci neuronowej poszukiwano na obrazie ostrza obrazu jego zużycia.
Aplications to image analyse was presented in this work. With use digital camera was measured the cutting angle of turning tool. Special recognizing procedure was used to object and human face recognize by compare with image in knowledge base. Was short presented special software to area of tool wear recognition with neural network use.
Źródło:
Diagnostyka; 2005, 33; 123-129
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological analysis of additively manufactured copies of a fossil skull
Autorzy:
Rucki, Mirosław
Garashchenko, Yaroslav
Kogan, Ilja
Ryba, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173724.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additive manufacturing
Madygenerpeton
optical measurement
statistical analysis
produkcja dodatkowa
pomiar optyczny
analiza statystyczna
Opis:
This paper presents the results of a metrological analysis of the additively manufactured (AM) copies of a complex geometrical object, namely the fossil skull of Madygenerpeton pustulatum. This fossil represents the unique remains of an extinct “reptiliomorph amphibian” of high importance for palaeontological science. For this research, the surface was scanned and twelve different copies were 3D-printed using various devices, materials, and AM techniques. The same digitized model was used as a reference to compare with the surfaces obtained by Mitutoyo Coordinate Measuring Machine (CMM) CRYSTA-Apex S 9166 for each copy. The fidelity of the copies was assessed through statistical analysis of the distances between compared surfaces. The methodology provided a good background for the choice of the most accurate copies and the elimination of the less accurate ones. The proposed approach can be applied to any object of complex geometry when reproduction accuracy is to be assessed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 6; art. no. e143827
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical Assessment of the Microstructure of Barite Aggregate from Different Deposits Using X-Ray Microtomography and Optical Microscopy
Autorzy:
Żołek, N.
Ranachowski, Z.
Ranachowski, P.
Jóźwiak-Niedźwiedzka, D.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351890.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
barite ore
barite aggregate
microstructure
optical microscopy
thin sections analysis
X-ray tomography
Opis:
Two different barite ore (barium sulfate BaSO4) specimens from different localizations were tested and described in this paper. Analysis of the microstructure was performed on polished sections, and on thin sections using X-ray microtomography (micro-CT), and optical microscopy (MO). Microtomography allowed obtaining three-dimensional images of the barite aggregate specimens. In the tomograms, the spatial distribution of the other polluting phases, empty space as well as cracks, pores, and voids – that exceeded ten micrometers of diameter-were possible to visualize. Also, the micro-CT allowed distinguishing between minerals of different density, like SiO2 and BaSO4. Images obtained and analyzed on thin sections with various methods using the optical microscopy in transmitted light delivered additional information on the aggregate microstructure, i.e. allow for estimation of the different kinds of inclusions (like the different density of the minerals) in the investigated specimens. Above methods, which were used in the tests, completed each another in order to supply a set of information on inclusions’ distribution and to present the important differences of the barite aggregate specimens microstructure.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 697-702
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and evaluation of a needle tip measurement system based on binocular vision
Autorzy:
Lin, Yuyang
Shi, Yunlai
Zhang, Jun
Wang, Fugang
Sun, Haichao
Powiązania:
https://bibliotekanauki.pl/articles/220501.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
needle tip measurement
binocular vision system
measurement capability analysis
non-contact optical positioning
Opis:
The precise location of the needle tip is critical in robot-assisted needle-based percutaneous interventions. An automatic needle tip measuring system based on binocular vision technology with the advantages of non-contact, excellent accuracy and high stability is designed and evaluated. First the measurement requirements of the prostate intervention robot are introduced. A laser interferometer is used as the reference for measuring the position of the needle tip whose relative position variation is described as the needle tip distance in the time domain. The parameters of the binocular cameras are obtained by Zhang’s calibration method. Then a robust needle tip extraction algorithm is specially designed to detect the pixel coordinates of the needle tip without installing the marked points. Once the binocular cameras have completed the stereo matching, the 3D coordinates of the needle tip are estimated. The measurement capability analysis (MCA) is used to evaluate the performance of the proposed system. The accuracy of the system can be controlled within 0.3621 mm. The agreement analysis is conducted by the Bland-Altman analysis, and the Pearson correlation coefficient is 0.999847. The P/T ratio value is 16.42% in the repeatability analysis. The results indicate that the accuracy and stability of the binocular vision needle tip measuring system are adequate to meet the requirement for the needle tip measurement in percutaneous interventions.
Źródło:
Metrology and Measurement Systems; 2020, 27, 3; 495-512
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deep data analysis in gigabit passive optical networks
Autorzy:
Horvath, T.
Krkos, R.
Dubravec, L.
Powiązania:
https://bibliotekanauki.pl/articles/174869.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
GPONXpert
gigabit passive optical networks
GPON
signalling
user plane
frame structure
payload analysis
Opis:
This paper focuses on practical aspects of gigabit passive optical networks (GPON) diagnostics during deployment, for root-cause analysis and for research purposes. While GPON signalling analysis is already quite commonly used for diagnostics, the aim of this work is a holistic approach, including both signalling and user plane (payload) analysis. User plane analysis, especially if targeted at payload Ethernet, IP and transport layers, enables detection of additional group of problems that could limit or even prevent GPON internetworking and thus degrade the user perceived service quality. Integrated signalling and payload analysis is also interesting from the research point of view, leading to the ability to study equipment idiosyncrasies that would be hard to detect otherwise and it is also one of the enablers of equipment security verification. The mentioned theories were tested during a practical diagnostic session on a real GPON network deployment and this paper presents the findings.
Źródło:
Optica Applicata; 2017, 47, 1; 157-170
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zachowania dynamicznego układu wstęgi papierniczej z wykorzystaniem pomiaru optycznego
Dynamic analysis of paper web with utilization of optical measurement
Autorzy:
Cedrowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/152638.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar optyczny
badania dynamiczne
częstotliwości drgań własnych układu
optical measurement
dynamic analysis
natural frequencies
Opis:
W pracy przedstawiono wyniki analiz dynamicznych drgań płyty wykonanej z tektury falistej. Rezultaty obliczeń teoretycznych częstości drgań własnych płyty, w których wykorzystano model kompozytowy tektury, porównano z wynikami badań doświadczalnych. Do badań doświadczalnych opracowano metodę wyznaczania częstości własnych w oparciu o pomiar optyczny z wykorzystaniem kamery cyfrowej. Ze względu na własności fizyczne materiałów papierniczych, pomiar optyczny jest szczególnie użyteczny przy prowadzeniu badań dynamicznych. Pomiary z użyciem kamery do przebiegów szybkozmiennych pozwalają na wyznaczenie częstości i odpowiadających im postaci drgań z dużą dokładnością.
Theoretical and experimental results of dynamic analysis of rectan-gular plate made of corrugated board were presented in this paper. The composite model of corrugated board was applied to theoretical calculations. In order to determine physical parameters of cardboard, papers of wave from central layers were subjected to homogenization process. Due to the fact that corrugated board and paper have small bending stiffness, a method based on optical measurement of determination the natural frequencies of the plate was used in experimental investigations. Rectangular plate with two straight supported and two free edges was fixed to the vibrating table. Analysis of natural modes enables the observation of vibrations in the vicinity of resonance frequencies. Using optical measurement of fast motion the natural frequency of the plate and amplitudes of vibrations can be measured with high precision. Three films for three different frequencies near the resonance peak are performed to allocate the top of parabola. Optical measurement precisely records dynamic behaviour of the plate made of corrugated board. The introduced results of dynamic investigations show that composite model of corrugated board is not enough precise, especially for higher frequencies.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 905-906
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical 3D scanning methods in biological research - selected cases
Metody skanowania optycznego 3D w badaniach biologicznych – opis przypadków
Autorzy:
Paśko, S.
Powiązania:
https://bibliotekanauki.pl/articles/3131489.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
3D scanner
biological research
optical method
algorithm
measurement system
point cloud
marker
data analysis
Źródło:
Acta Scientiarum Polonorum. Zootechnica; 2021, 20, 1; 3-14
1644-0714
Pojawia się w:
Acta Scientiarum Polonorum. Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the repeatability of fuel spray indexes in a spray-guided direct-injection spark-ignition engine
Autorzy:
Pielecha, I.
Powiązania:
https://bibliotekanauki.pl/articles/132912.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
spray atomization
optical research
image analysis
fuel penetration
rozpylanie
badania optyczne
analiza obrazu
przenikanie paliwa
Opis:
The development and research works on liquid fuel injection in spark-ignited direct injection (SIDI) engines, apart from so common in recent years simulation methods, still have a significant cognitive substrate. This is related to experimental research on repeatability of combustion process using multi- and mono-cylinder test engines and Rapid Compression Machines. The repeatability of preparation and delivery processes has immediate impact on repeatability of combustion process. Except for the necessity of obtaining the repeatability of fuel amounts, the repeatability of injected fuel spray is required. The penetration range and spray area in combustion chamber have direct impact on mixture creation and formation. The optical research on fuel injection has been made in order to determinate its repeatability. The research on unrepeatability of fuel spray propagation has been conducted using piezoelectric injectors of outward-opening type, being primary elements of the spray-guided combustion systems. The results of research were presented in the form of index of variation of the selected parameters. The evaluation of the results of the optical research concerns radial spray penetration and fuel spray velocity. Unrepeatability has been presented with coefficient of variation of radial penetration in relation to the time of injection duration. It has been observed that the coefficients of various parameters are lower with longer times of fuel injection.
Źródło:
Combustion Engines; 2016, 55, 1; 49-55
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Machine learning system for automated blood smear analysis
Autorzy:
Grochowski, Michał
Wąsowicz, Michał
Mikołajczyk, Agnieszka
Ficek, Mateusz
Kulka, Marek
Wróbel, Maciej S.
Jędrzejewska-Szczerska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/220750.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical microscopy
blood cells
biophotonics
image analysis
classification
eigenfaces
neural networks
decision support
nanodiamonds
bioimaging
Opis:
In this paper the authors propose a decision support system for automatic blood smear analysis based onmicroscopic images. The images are pre-processed in order to remove irrelevant elements and to enhancethe most important ones – the healthy blood cells (erythrocytes) and the pathologic ones (echinocytes). The separated blood cells are analysed in terms of their most important features by the eigenfaces method. The features are the basis for designing the neural network classifier, learned to distinguish between erythrocytes and echinocytes. As the result, the proposed system is able to analyse the smear blood images in a fully automatic way and to deliver information on the number and statistics of the red blood cells, both healthy and pathologic. The system was examined in two case studies, involving the canine and human blood, and then consulted with the experienced medicine specialists. The accuracy of classification of red blood cells into erythrocytes and echinocytes reaches 96%.
Źródło:
Metrology and Measurement Systems; 2019, 26, 1; 81-93
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda optycznej inspekcji w procesie montażu łożysk tocznych
The optical inspection method in the process of assembly of roller bearings
Autorzy:
Czajka, P.
Garbacz, P.
Powiązania:
https://bibliotekanauki.pl/articles/256861.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
inspekcja optyczna
analiza obrazów
detekcja wad
łożysko toczne
optical inspection
image analysis
fault detection
roller bearing
Opis:
W artykule zaprezentowano opracowaną metodę optycznej inspekcji poprawności montażu łożysk tocznych. W celu weryfikacji metody zostało wykonane eksperymentalne stanowisko badawcze. Do kontroli wizyjnej został zastosowany modułowy sterownik wizyjny z monochromatyczną kamerą CCD i oświetlaczem pierścieniowym. Opracowano algorytm detekcji wad, który został zaimplementowany w oprogramowaniu systemu. Zaprezentowano działanie algorytmu z podziałem na poszczególne etapy procesu inspekcji. Opisano zastosowane funkcje z zakresu przetwarzania i analizy obrazów. Przeanalizowano zachowanie algorytmu inspekcji w sy-tuacjach nietypowych, które mogą wystąpić w warunkach przemysłowych. Zaprezentowano przykłady inspekcji łożysk z wykorzystaniem opracowanej metody. Przedstawiono wyniki prób systemu kontroli wizyjnej w warunkach eksploatacyjnych na przemysłowej linii montażu łożysk tocznych.
The article presents the optical inspection method for correct assembly of roller bearings. The experimental research stand was made for verification of the method. The modular vision controller with the monochromatic CCD camera and the ring lighting were used for optical inspection. The algorithm for detecting faults was developed and was implemented in the software of the vision system. The operation of the algorithm was presented for each of the individual stages of inspection process. The applied functions from the field of image processing and analysis were described. The functioning of the inspection algorithm was analysed for untypical situations, which can occur in industry conditions. Examples of bearing inspections, with use of the developed method, were presented. Results of tests of the system for optical inspection were presented in working conditions on the industrial line for assembly of bearings.
Źródło:
Problemy Eksploatacji; 2011, 4; 65-78
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kamera termowizyjna wspomagająca nawigację pojazdów UAV
Thermal Imaging Camera Supporting the Navigation of UAVs
Autorzy:
Bieszczad, Grzegorz
Sawicki, Krzysztof
Gogler, Sławomir
Ligienza, Andrzej
Mścichowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2068623.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
termowizja
nawigacja
analiza obrazu
przetwarzanie obrazu
UAV
przepływ optyczny
thermal imaging
navigation
image analysis
image processing
optical flow
Opis:
Tematem artykułu jest ocena skuteczności opracowanego czujnika przeznaczonego do wspomagania nawigacji bezzałogowych statków powietrznych (BSP). Jego działanie opiera się na przetwarzaniu obrazów pozyskiwanych z kamery termowizyjnej pracującej w paśmie długofalowej podczerwieni (LWIR) umieszczonej pod podwoziem pojazdu. Przemieszczenie przestrzenne pojazdu określane jest poprzez analizę ruchu charakterystycznych punktów promieniowania cieplnego (grunt, las, budynki itp.) na zdjęciach uzyskanych za pomocą kamery termowizyjnej. Zakres i kierunek przemieszczenia uzyskuje się poprzez przetwarzanie strumienia kolejnych obrazów za pomocą algorytmu opartego na przepływie optycznym wyznaczanym w czasie rzeczywistym. Analiza rozkładu promieniowania pozwala na obliczenie wektora translacji kamery w przestrzeni. Zaletami systemów pomiarowych opartych na analizie obrazu termicznego, w porównaniu z tradycyjnymi inercyjnymi czujnikami nawigacyjnymi, jest brak efektu dryftu, odporność na zmiany pola magnetycznego, mała podatność na zakłócenia elektromagnetyczne oraz na zmiany warunków atmosferycznych. W przeciwieństwie do czujników czułych na światło widzialne, czujnik termowizyjny oferuje pracę w całkowitej ciemności (noce o złej pogodzie i w pomieszczeniach).
The topic of this paper is an evaluation of developed sensor intended for navigation aid of unmanned aerial vehicles (UAVs). Its operation is based on processing images acquired with a thermal camera operating in the long-wave infrared band (LWIR) placed underneath a vehicle’s chassis. The vehicle’s spatial displacement is determined by analyzing movement of characteristic thermal radiation points (ground, forest, buildings, etc.) in pictures acquired by the thermal camera. Magnitude and direction of displacement is obtained by processing the stream of consecutive pictures with optical-flow based algorithm in real time. Radiation distribution analysis allows to calculate camera’s self-translation vector. Advantages of measuring translation based on thermal image analysis is lack of drift effect, resistance to magnetic field variations, low susceptibility to electromagnetic interference and change in weather conditions as compared to traditional inertial navigation sensors. As opposed to visible light situational awareness sensors, it offers operation in complete darkness (harsh weather, nights and indoors). The topic of this paper is an evaluation of developed sensor intended for navigation aid of unmanned aerial vehicles (UAVs). Its operation is based on processing images acquired from a thermal camera operating in the long-wave infrared band (LWIR) placed underneath a vehicle’s chassis. The vehicle’s spatial displacement is determined by analyzing movement of characteristic thermal radiation points (ground, forest, buildings, etc.) in pictures acquired by the thermal camera. Magnitude and direction of displacement is obtained by processing the stream of consecutive pictures with optical-flow based algorithm in real time. Radiation distribution analysis allows to calculate camera’s self-translation vector. Advantages of measuring translation based on thermal image analysis is lack of drift effect, resistance to magnetic field variations, low susceptibility to electromagnetic interference and change in weather conditions as compared to traditional inertial navigation sensors. As opposed to visible light situational awareness sensors, it offers operation in complete darkness (harsh weather, nights and indoors).
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 3; 43--50
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja systemu wizyjnego do monitorowania procesów zgrzewania tarciowego
Concept of the vision system for monitoring of friction stir welding process
Autorzy:
Giesko, T.
Pietras, A.
Mężyk, J.
Kowieski, S.
Powiązania:
https://bibliotekanauki.pl/articles/256857.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
zgrzewanie tarciowe FSW
kontrola jakości
inspekcja optyczna
analiza termograficzna
friction stir welding (FSW)
quality inspection
optical inspection
thermal analysis
Opis:
W artykule zaprezentowano koncepcję metody i systemu do monitorowania procesów zgrzewania tarciowego FSW z wykorzystaniem analizy obrazów w podczerwieni i paśmie widzialnym. Termogramy pokazujące rozkład i zmiany temperatury w obrębie zgrzeiny zawierają kompleksowe informacje o przebiegu procesu zgrzewania tarciowego oraz o strukturze zgrzeiny. Połączona analiza obrazów zgrzeiny, zarejestrowanych za pomocą kamery termowizyjnej i kamery wizyjnej umożliwi monitorowanie on-line procesu zgrzewania tarciowego oraz detekcję wad powierzchniowych i podpowierzchniowych zgrzeiny. W artykule omówiono najważniejsze zagadnienia modelowania systemu wizyjnego i algorytmu inspekcji.
The paper presents the idea of a method and system for monitoring of friction stir welding FSW with the use of analysis of infrared and vision images. Thermal images present a temperature distribution and fluctuation within a weld joint, and contain complex information about welding process and weld structure. The combined analysis of infrared and vision images of weld will enable the on-line process monitoring and detection of surface and subsurface defects. The key aspects of modeling of a vision system and inspection algorithm are described in the paper.
Źródło:
Problemy Eksploatacji; 2011, 4; 91-102
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Forum ophthalmicum - how to take control over accumulation of diagnostic data from macular OCT with benefit for both doctor and patient?
Forum ophthalmicum – jak uporządkować natłok informacji z badania OCT plamki z korzyścią dla lekarza i pacjenta?
Autorzy:
Kaczmarek, Dorota Maria
Powiązania:
https://bibliotekanauki.pl/articles/2040407.pdf
Data publikacji:
2021-09-30
Wydawca:
Medical Education
Tematy:
wAMD
optical coherent tomography
anti-VEGF therapy
medical data analysis
optyczna koherentna tomografia
terapia anty-VEGF
analiza danych medycznych
Opis:
Wet age-related macular degeneration (wet AMD) is a disease which requires regular diagnostic tests such as macular optical coherent tomography which is extremely important both in diagnosis and disease monitoring. With constant aging of the population, we are dealing with an increasing incidence rate of AMD, which makes it even more important to have a tool allowing for quick and precise analysis of anatomical changes in macular region, particularly in the current complicated epidemiological situation when diagnostic time should be used most efficiently to plan the follow-up treatment. Forum® software allows for the precise analysis of many tests performed in a single patient and combining it with treatment effectiveness assessment which substantially accelerates the diagnostics.
Wysiękowa postać zwyrodnienia plamki związanego z wiekiem to schorzenie, które wymaga regularnej diagnostyki okulistycznej, głównie w postaci okresowo wykonywanej optycznej koherentnej tomografii plamki. Rola tego badania jest niezmiernie ważna zarówno w procesie diagnostyki, jak i monitorowania. Jako że wraz ze starzeniem się populacji mamy do czynienia ze wzrostem zachorowalności na wysiękową postać zwyrodnienia plamki związanego z wiekiem, coraz bardziej istotna staje się potrzeba szybkiej i precyzyjnej analizy zmian anatomicznych obszaru plamkowego, tak aby w dodatkowo skomplikowanej sytuacji epidemiologicznej maksymalnie efektywnie wykorzystać czas przeznaczony na diagnostykę oraz zaplanować dalsze etapy leczenia. Dzięki oprogramowaniu o nazwie Forum® zyskujemy możliwość precyzyjnej analizy wielu badań wykonanych u danego pacjenta, łącznie z oceną skuteczności leczenia na przestrzeni czasu, co znacznie przyspiesza procesy diagnostyczne.
Źródło:
OphthaTherapy; 2021, 8, 3; 160-165
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synteza, charakterystyka, właściwości termiczne i elektrochemiczne polimerów iminowych zawierających jednostki pirydynowe i pirymidynowe
Synthesis, characterization, thermal and electrochemical properties of imine polymers containing pyridine and pyrimidine units
Autorzy:
Karaer, H.
Kaya, I.
Aydın, H.
Powiązania:
https://bibliotekanauki.pl/articles/947552.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
poli(iminy)
poli(fenoksy-iminy)
właściwości optyczne
analiza termograwimetryczna
półprzewodnictwo
poly(imines)
poly(phenoxy-imines)
optical properties
thermogravimetric analysis
semiconductivity
Opis:
Polizasady Schiffa zsyntetyzowano metodą polimeryzacji utleniającej 2-hydroksybenzaldehydu (2-HBA) w środowisku alkalicznym, w obecności NaOCl jako utleniacza, a następnie szczepiono otrzymany polialdehyd za pomocą amin zawierających grupy pirydynowe i pirymidynowe. Uzyskane polimery charakteryzowano metodami GPC i SEM, a ich struktury potwierdzono za pomocą spektroskopii FT-IR, 1H NMR, 13C NMR i UV-Vis. Właściwości optyczne polizasad Schiffa analizowano spektroskopią fluorescencyjną i UV-Vis, a właściwości termiczne określono metodami TG, DTA i DSC. Korzystając z woltamperometrii cyklicznej (CV) oraz pomiarów przewodności ciała stałego metodą czteropunktową badano właściwości elektrochemiczne otrzymanych polimerów. Pomiary te wskazują na półprzewodnikowy charakter polimerów. Stwierdzono, że wartości liczbowo średniego ciężaru cząsteczkowego (Mn), wagowo średniego ciężaru cząsteczkowego (Mw) i stopnia polidyspersji (Đ) poli(2-hydroksybenzaldehydu) (P-2HBA) wyznaczone na podstawie analizy GPC są równe, odpowiednio, 5900, 5450 oraz 1,08. Szerokość elektrochemicznej przerwy energetycznej (E'g) oznaczono metodą CV, natomiast szerokość optycznej przerwy energetycznej (E'g) za pomocą spektroskopii UV-Vis.
Schiff bases polymers were synthesized from 2-hydroxybenzaldehyde (2-HBA) via oxidative polymerization method in an aqueous alkaline medium in the presence of NaOCl as an oxidant. Then, these polymeric Schiff bases were prepared from the polyaldehyde by grafting each of them with different amines containing pyridine and pyrimidine groups. The structures of polymers were confirmed by FT-IR, 1H NMR, 13C NMR, and UV-Vis measurements. The polymers were characterized by GPC and SEM analyses. Furthermore, their optical properties were determined by UV-Vis and fluorescence spectroscopy, their electrochemical properties by cyclic voltammetry (CV) analysis and solid state conductivity measurements by the four-point probe technique, their thermal behavior by TG, DTA, and DSC measurements. The electrical conductivity of the polymers was also measured and found that they are semiconductive. The number average molecular weight (M'n), the weight average molecular weight (M'w), and dispersity (Đ) values of the polymers were found from GPC analysis and were equal 5900, 5450 and 1.08, respectively, for poly(2-hydroxybenzaldehyde) (P-2HBA) polymer. Electrochemical energy gap (E'g) was found by CV, whereas optical band gap (E'g) was determined by UV-Vis measurements.
Źródło:
Polimery; 2017, 62, 3; 170-180
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
All-optical sensor based on nonlinear multimode interference coupler features
Autorzy:
Tajaldini, M
Jafri, M Z M
Powiązania:
https://bibliotekanauki.pl/articles/173957.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nonlinear multimode interference (NLMMI)
nonlinear modal propagation analysis (NMPA)
all-optical sensor
cladding refractive
chemical sensing
earthquake
air pollution
water-soluble
Opis:
In this study, we investigate the sensing applications in the presence of the nonlinear effects by proposing an all-optical sensor and considering nonlinear effects on modal propagation and output intensity based on an ultra-compact nonlinear multimode interference coupler. The sensor can be tuned to have the highest sensitivity in the wavelength and refractive index ranges and can detect water-soluble chemicals, air-pollutions, earthquake wave, blood parameters, and heart operation. The results indicate high output sensitivity to input wavelength whereas the nonlinear effects appear in the medium. This sensitivity led us to propose a wave sensor of both transverse and longitudinal waves, such as acoustic and light waves, when an external wave interacts with an input waveguide. For instance, this sensor can be implemented using a long input that is inserted in the land, and any wave could then be detected from the Earth. The visible changes in intensity at the output facet in various refractive indices of the surrounding layer show the high sensitivity to the refractive index of the surrounding layer, which is the foundation of introducing a sensor. Generally, the results show the high efficiency of nonlinear effects in all-optical sensing performances.
Źródło:
Optica Applicata; 2015, 45, 3; 327-340
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical-Experimental Analysis of Plastic Flow Beginning Phase Round the Hole in the Thin Shield Under Tension
Autorzy:
Bućko, S.
Jodłowski, H.
Trzebicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/387063.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
identyfikacja odkształceń plastycznych
interferencja optyczna
koncentracja naprężeń
badania eksperymentalne
analiza MES
plastic strain identification
optical interference
stress concentration
experimental research
FEM analysis
Opis:
The method of recognition of plastic strains with the use of optical interference was characterized in the work. The idea of the method was shown on the example test for 15HM steel tension. The results of experimental testing of plastic strains initiation in the thin shield with opening of O20 diameter under tension, especially considering round the hole zone were presented in further part of the work. The experiment was carried out with the use of method mentioned above. In the experiment the stresses initializing plastic deformations and the shape of plastic zone were determined. The stress state analysis in the hole zone in the specimen under tension was realized with the use of finite element method. The calculations were done for two significantly different hole diameters. The results of FEM calculations allow for certification that for the holes of diameters significantly bigger than the shield thickness round the hole plane stress state occurs.
Źródło:
Acta Mechanica et Automatica; 2012, 6, 1; 21-25
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowo opracowana metoda pomiaru rozkładu azotu i dodatków stopowych w warstwie azotowanej i węgloazotowanej w stopach żelaza
Newly developed method for measuring the decomposition of nitrogen and alloying elements in nitrated and carbonitrided layers of ferrous alloys
Autorzy:
Żebrowski, J.
Czawa, B.
Pawlińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/391762.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
optyczna spektrometria atomowa ze wzbudzeniem jarzeniowym
stal azotowana
analiza profilowa warstw powierzchniowych
glow discharge optical atomic emission spectrometry
nitrated steel
layer profile analysis
Opis:
W artykule przedstawiono metodę oceny warstwy azotowanej oraz węgloazotowanej na powierzchni badanego materiału (stali). W skład wyżej wymienionej metody wchodzi pomiar grubości warstwy, jak i rozkładu występujących w niej pierwiastków, z wykorzystaniem programu QDP (profilowa analiza ilościowa), w który wyposażony jest optyczny spektrometr emisyjny ze wzbudzeniem jarzeniowym GDS 850A firmy LECO Corp. Wyniki przedstawione w artykule pozwalają ocenić opracowaną metodę jako przydatną do badania warstw azotowanych i węgloazotowanych.
This article presents the evaluation method for nitrated and carbonitrided layer on the surface of the examined material (steel). The above mentioned method comprises the measurement of layer thickness, as well as decomposition of elements occurring in it, with the use of QDP program (quantitative profile analysis) with which GDS 850A glow discharge optical emission spectrometer is equipped. Conditions presented in this article enable us to assess the developed method as useful in the examination of nitrated and carbonitrided layers.
Źródło:
Prace Instytutu Odlewnictwa; 2014, T. 54, nr 4, 4; 89-98
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scanning optical and electron microscopes with computer image acquisition
Autorzy:
Konstankiewicz, K.
Pukos, A.
Powiązania:
https://bibliotekanauki.pl/articles/25623.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
electron microscope
scanning optical microscope
microscopic method
tandem scanning reflected light microscope
computer image analysis
scanning electron microscopy
biological material
rotary microtome
confocal microscopy
Źródło:
International Agrophysics; 1995, 09, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A non-contact laser method based on the imaging and analysis of scattered light used for assessment of surface imperfections
Bezstykowa metoda laserowa wykorzystująca obrazowanie i analizę rozpraszania światła przeznaczona do oceny skaz powierzchni
Autorzy:
Kapłonek, W.
Nadolny, K.
Valicek, J.
Powiązania:
https://bibliotekanauki.pl/articles/153486.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metody optyczne
skaterometria laserowa
przetwarzanie i analiza obrazu
skazy powierzchni
powierzchnia obrobiona
optical methods
laser scatterometry
image processing and analysis
surface imperfections
machined surfaces
Opis:
In the work laser scatterometry supported by image processing and analysis techniques was used for assessment of surface imperfections (SIM) of machined surfaces presented and discussed. During the experiment the ground and polished samples made from aluminium, brass, cast iron and steel, with visible SIM, were used. Surface topographies (Talysurf CLI 2000 - Fig. 1) and images of scattered light (experimental setup - Fig. 2) were acquired for selected areas of those surfaces. Analysis of the data obtained was carried out using Image-ProŽ Plus and TalyMap Silver software (Fig. 3). The results of the experiment enabled us to conclude that the methods used were both useful and could offer an interesting assessment of machine parts characterized by various types of SIM.
Jednym z ważniejszych problemów we współczesnym wytwarzaniu i eksploatacji maszyn oraz urządzeń jest ich odpowiednia diagnostyka. Proces diagnostyczny może dotyczyć m.in. detekcji i analizy skaz powierzchni powstających w sposób niezamierzony lub przypadkowy podczas obróbki, przechowywania lub użytkowania powierzchni części maszyn. Ocena skaz powierzchni może być przeprowadzana z wykorzystaniem szeregu metod pomiarowych. Ważną rolę odgrywają tutaj metody optyczne w największym stopniu wykorzystywane w warunkach produkcyjnych. W pracy pokazano, iż optyczne metody skaterometrii laserowej wspomagane przez techniki przetwarzania i analizy obrazu mogą stanowić ciekawą alternatywę w przypadku oceny części maszyn, charakteryzujących się występowaniem różnego rodzaju skaz powierzchni. W pracy opisano metodę ARS wykorzystującą obrazowanie i analizą światła rozproszonego przeznaczoną do detekcji skaz powierzchni elementów maszyn obrabianych różnymi technikami obróbkowymi. Zaproponowana metoda charakteryzowała się m.in. dużą czułością, bezstykowym sposobem pomiaru oraz krótkim czasemprzeprowadzenia oceny. Parametry uzyskane z analizy obrazu (oprogramowanie Image ProŽ-Plus) porównywano z wybranymi dwu- i trójwymiarowymi mapami powierzchni skaz (oprograowanie TalyMap Silver) rejestrowanymi profilometrem optycznym Talyscan CLI2000 firmy Taylor Hobson. Przeprowadzone badania potwierdziły dużą użyteczność zastosowanej metody rozpraszania światła, mogącej stanowić jedną z propozycji rozwiązania problemu diagnostyki części maszyn i urządzeń w warunkach laboratoryjnych lub
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 6, 6; 554-558
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology of increasing accuracy of gear models manufactured using additive FDM method
Metodyka poprawy dokładności modeli kół zębatych wytwarzanych z zastosowaniem addytywnej metody FDM
Autorzy:
Budzik, G.
Dziubek, T.
Kozik, B.
Sobolewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/951474.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gears
3D-CAD
RP techniques
FDM technology
optical measurement
accuracy analysis
koła zębate
3D CAD
techniki RP
technika FDM
pomiary optyczne
analiza dokładności
Opis:
The paper presents methodology of increasing the accuracy of models of gears made applying additive methods. As a part of activities related to this subject, it was necessary to develop 3D-CAD research gears, which were the basis for producing physical models made using incremental FDM manufacturing technology. The created models were verified in order to determine the accuracy of resulting geometry. Then modifications were introduced to models so as to increase their accuracy. On this basis, in an iterative process, compensation coefficients were calculated to ensure reduction of defects in geometry with respect to a nominal 3D-CAD model.
W artykule przedstawiono sposób poprawy dokładności modeli kół zębatych wytwarzanych z zastosowaniem metod addytywnych. Opracowano model 3D-CAD badawczych kół zębatych. Stanowiły podstawę do wytworzenia modeli fizycznych wykonywanych z zastosowaniem przyrostowej techniki wytwarzania FDM. Modele poddano weryfikacji w celu określenia dokładności ich wykonania. Wprowadzono modyfikację tych modeli dla podwyższenia ich dokładności. W procesie iteracyjnym ustalono wartości współczynnika kompensacji odkształceń. Zapewniono zmniejszenie błędów wykonania modelu w porównaniu z nominalnym modelem 3D-CAD.
Źródło:
Advances in Manufacturing Science and Technology; 2015, 39, 4; 37-52
0137-4478
Pojawia się w:
Advances in Manufacturing Science and Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie procedur przygotowania próbek herbat do analizy wielopierwiastkowej metodami ICP OES i FAAS
Autorzy:
Szymczycha-Madeja, A.
Wełna, M.
Pohl, P.
Stelmach, E.
Jędryczko, D.
Powiązania:
https://bibliotekanauki.pl/articles/273894.pdf
Data publikacji:
2015
Wydawca:
Roble
Tematy:
herbata
analiza wielopierwiastkowa
optyczna spektrometria emisyjna
spektrometria atomowa absorpcyjna płomieniowa
ICP-OES
FAAS
próbka badawcza
tea
multi-element analysis
optical emission spectrometry
flame atomic absorption spectrometry
Opis:
W pracy porównano różne procedury (klasyczne i alternatywne) przygotowania próbek herbaty czarnej i zielonej w ich analizie wielopierwiastkowej metodami ICP OES i FAAS. Analiza statystyczna wyników wraz z oceną wybranych parametrów walidacyjnych porównywanych metod analitycznych pozwoliła na wybór znacznie prostszej i szybszej procedury przygotowania próbek bez konieczności ich rozkładu mokrego.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2015, 20, 4; 20-23
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda rejestracji, przetwarzania i analizy obrazu do cyfrowego opisu powierzchni manekina
The method of recording, converting and images analysis for digital model of phantom surface
Autorzy:
Lesiakowska-Jabłońska, M.
Powiązania:
https://bibliotekanauki.pl/articles/151392.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza obrazu
przetwarzanie obrazu
skanowanie 3D
cyfrowe modele obiektów 3D
pomiarowe metody optyczne
images analysis
3D scanning
digital model of 3D objects
optical representation method
Opis:
Zapis powierzchni fantomów - manekinów (stosowanych powszechnie w odzieżownictwie fizycznych modeli budowy ciała ludzkiego o określo-nej uśrednionej charakterystyce wymiarowej) jest konieczny z punktu widzenia prac nad inżynierskimi metodami konstrukcji wykrojów odzieży. Potwierdzają to liczne prace z tego obszaru prowadzone przez szereg placówek naukowych i badawczych świata [1, 2, 3]. Dzięki badaniom prowadzonym w Katedrze Odzieżownictwa PŁ opracowano metodę fotogrametryczną pozwalającą na rejestrację, przetworzenie, analizę, opis cech wymiarowych i odwzorowanie 3D (three dimensional) powierzchni manekinów [4].
Phantom surface representation based on computer analysis of phantom 2D images is a very challenging problem. The representation of phantom surface is necessary for development of engineering techniques for constructing shapes of clothes. The phantoms are widely used in clothing science as a model of human body. This is confirmed by large number of publications from many research institutes [1, 2, 3]. At the Clothing Department, Technical University of Łódź, the new method of digital representation of phantom surface was developed [4]. Thus optical representation method was used to obtain a digital phantom surface model. The indirect method of 3D surface measurement was proposed, where geometrical features of an analysed object were estimated based on analysis of series of its 2D images. The 2D image is a central projection of the analysed object. The most important problem is to register such a projection and then perform an appropriate analysis. To obtain a digital model of objects with size comparable to the human body, the measurement bench was assembled as shown in Fig. 1. This bench contains: analysed object (1); a projector (2) which is a source of two light half-planes (bright and dark); they are projected onto analysed object (1) and are called as "horizontal light half-plane"; a TV camera (9) as a video signal source for the computer (10); it is moved along with a projector during measurement process and it is at an angle ? in relation to light half-plane; two stepper motors (3, 4) with a driving system (5), used to move a camera (with Δζ step) and rotate a phantom (with an angle Δφ); mechanical circuit, which is used to move a camera and a projector; computer (10) used to control whole a system, equipped with two monitors (6, 7), add-on cards and specialised software; vertical reference half-plane, firmly fixed to measure a distance from the analysed object. This measurement bench was used for acquisition and analysis of images of investigated objects.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 44-47
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zautomatyzowany system kontroli wizyjnej tabletek i kapsułek pakowanych w przezroczyste blistry
Automated optical system for tablets and capsules packaging inspection
Autorzy:
Zając, J.
Małkiński, W.
Wójcik, J.
Karliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/256633.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
wizja maszynowa
inspekcja optyczna
przetwarzanie obrazu
analiza obrazu
inspekcja pakowania
tabletka
kapsułka
system zarządzania jakością
machine vision
optical inspection
image processing
image analysis
tablet
capsule
packaging inspection
quality management system
Opis:
W artykule przedstawiono charakterystykę zautomatyzowanego systemu przeznaczonego do kontroli wizyjnej tabletek i kapsułek pakowanych w przezroczyste blistry. Inspekcja jakości pakowania obejmuje: wykrywanie braku tabletek w gnieździe lub ich nieprawidłowe ułożenie, wykrywanie tabletek o niewłaściwym kolorze lub wymiarach, wykrywanie zanieczyszczeń blistra oraz sprawdzenie prawidłowości oznakowania blistra. Omówiono właściwości podstawowych składników sprzętowych systemu. Zaprezentowano moduły programowe związane z projektowaniem nastaw systemu, tworzeniem nowych zadań inspekcji, a także wizualizacją przebiegu inspekcji w trybie automatycznym. Przedstawiono właściwości i parametry techniczne systemu. Opracowany system umożliwia pełną archiwizację nastaw oraz wyników inspekcji.
The system described in the paper provides automated optical inspection of tablets and capsules packed in transparent blisters. The packaging inspection includes: detection of tablets/capsules presence in nests, detection of improper position of tablets, detection of tablets which have improper color or size, detection of blister contaminations, and marking inspection of blisters. Features of basic hardware components of the system are discussed. Software modules related to projects of system settings, creation of new inspection tasks and visualization of the inspection stream in automatic mode are presented as well. Main features and technical data of the system are described. The system also assures the possibility of full archiving of the inspection settings and results.
Źródło:
Problemy Eksploatacji; 2009, 1; 197-208
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody grawimetryczne i optyczne w pomiarach stężenia aerozoli
The use of optic and gravimetric methods relevant in aerosol concentration measurements
Autorzy:
Oberbek, Przemysław
Jakubiak, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/2202808.pdf
Data publikacji:
2021
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
analiza grawimetryczna
ocena jakości powietrza
niskokosztowe sensory optyczne
systemy monitorowania zagrożeń
pomiary w czasie rzeczywistym
gravimetric analysis
air quality assessment
low-cost optical sensors
systems for risk monitoring
real-time measurements
Opis:
Zgodnie z danymi GUS o zatrudnionych w warunkach zagrożenia na koniec 2019 r., 2. pod względem częstości występowania czynnikiem szkodliwym były pyły, na które narażonych było 50,4 tys. osób (15,9%). Ocena narażenia na pyły w środowisku pracy polega na wykonaniu grawimetrycznych pomiarów stężeń na stanowiskach pracy dla zidentyfikowanych rodzajów pyłów, określeniu wskaźników narażenia na pyły i porównaniu uzyskanych wartości wskaźników narażenia z wartościami najwyższych dopuszczalnych stężeń pyłów. Wadami metody grawimetrycznej jest m.in. brak informacji o zmianach stężenia w czasie, podatność na dodatkowe źródła emisji, długi czas potrzebny na uzyskanie wyniku. Mierniki stężenia pyłów, przedstawiające dane pomiarowe w czasie rzeczywistym lub zbliżonym do rzeczywistego, znajdują coraz więcej zastosowań. Produkowane są już na dużą skalę niskokosztowe, niewielkie sensory, które można stosować do wytwarzania relatywnie dokładnych mierników środowiskowych, a także stacjonarnych i mobilnych sieci sensorowych. Tego typu urządzenia mogą stanowić istotne wsparcie dla grawimetrycznej oceny stężenia pyłów na stanowiskach pracy.
According to the data of the Statistics Poland on employees exposed to the risks arising from work environment at the end of 2019, the second most frequent harmful factor was dust, to which 50,4 thousand people were exposed (15,9%). The assessment of exposure to dust in the work environment consists in performing gravimetric measurements of concentrations at workstations for the identified dust types, determining the dust exposure indicators and comparing the obtained exposure indicator values with the values of the maximum allowable dust concentrations. The disadvantage of the gravimetric method is the lack of information about changes in concentration over time, susceptibility to additional emission sources, long time needed to obtain the result and the inability to conduct continuous monitoring. Dust concentration meters presenting real time or near to real-time measurement data are finding more and more applications in monitoring of the external environment and working environment Small low-cost sensors are already produced on a large scale, which can be used to produce relatively accurate environmental meters, as well as stationary and mobile sensor networks. Such devices are also not without flaws, but they can provide important support for the gravimetric assessment of dust concentration at workstations.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2021, 2; 15-19
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie maksymalnych szerokości rys w strefie czystego zginania belek żelbetowych obliczonych wg EC2 i uzyskanych z badań
Comparison of maximum crack width in pure bending zone of RC beams calculated with EC2 standard and achieved from tests
Autorzy:
Goszczyńska, Barbara
Tworzowska, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/162488.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
rysa
system pomiarowy optyczny
Aramis 3D
szerokość rysy
obliczanie
belka żelbetowa
analiza wyników
Eurokod 2
crack
optical measuring system
crack width
calculation
reinforced concrete beam
results analysis
Eurocode 2
Opis:
W artykule przedstawiono porównanie wyników szerokości rys otrzymanych w trakcie badań 6 belek żelbetowych z zastosowaniem systemu optycznego 3D typu ARAMIS z wynikami teoretycznymi obliczonymi na podstawie normy EC2. Obliczenie normowej szerokości rysy wykonano z wykorzystaniem grubości otuliny projektowanej oraz grubości otuliny pomierzonej w badanych belkach. Wykazano, jak duży wpływ ma grubość otuliny na wyniki szacowania maksymalnej szerokości rysy, a także, że szerokość rysy obliczana wg wzorów podanych w obowiązującej normie EC2 może być oszacowana po stronie niebezpiecznej.
The paper presents a comparison between calculated (according to EC2 standard) and measured with the use ARAMIS optical measuring system width of cracks in 6 RC beams. The design thickness of concrete cover and measured thickness was used to calculate the maximum theoretical crack width in the 6 analyzed beams. The results indicate that the concrete cover thickness has high influence on calculated crack width. Also the analysis shows that the theoretical crack width can be smaller than measured crack width so the calculation can generate hazardous results.
Źródło:
Przegląd Budowlany; 2019, 90, 11; 28-33
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrooptyczny efekt Kerra w chemii
Electrooptic Kerr effect in chemistry
Autorzy:
Prezhdo, O.
Olan, K.
Zubkowa, W.
Preżdo, W.
Powiązania:
https://bibliotekanauki.pl/articles/171825.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
elektrooptyczny efekt Kerra
analiza konformacyjna
wewnątrzcząsteczkowe oddziaływania
oddziaływania wewnątrzcząsteczkowe
oddziaływania międzycząsteczkowe
polaryzowalność
moment dipolowy
stała Kerra
electro-optical Kerr effect
conformational analysis
intra-molecular interactions
intermolecular interactions
polarizability
dipole moment
Kerr constant
Opis:
The electro-optical Kerr effect finds wide application in conformational analysis of molecules and molecular aggregates [1–5], particularly in cases where the standard X-ray and NMR techniques cannot be used. For instance, NMR allows to establish conformations of linear and cyclic unsaturated organic compounds. However, it is less effective in an analysis of molecular complexes, particularly of those that have several rotational symmetry axes. In such cases a combination of techniques based on molecular dipole moments, electro-optical Kerr effect, optical Kerr effect, IR spectroscopy, and Rayleigh scattering can be applied [6]. The foundations of conformational analysis of molecular complexes using several complementary physical approaches are developed in Ref. [7]. The electro-optical methods are particularly useful for an investigation of intramolecular interactions [8–18]. The strength, direction and other details of intramolecular interactions can be determined by analyzing the deviations of the experimental molar Kerr constant (mK) from its value calculated according to the tensor-additive scheme that operates with polarizability tensors of molecular cores and functional groups [19, 20]. For instance, using this approach it has been shown that weakening of conjugation in an electron donor-acceptor chain can lead to flattening of the molecular structure [21]. The Kerr constant is also very sensitive to intermolecular interactions [22–29]. In order to assess quantitatively an extent of the solvent effect on the mK values, both molecular and continuum models of solution structure have been used [30, 31]. The mK values are greatly affected by the mutual orientation of solvent and solute molecules, which interact by dispersive, inductive and dipole-dipole forces [32]. Hydrogen and donor-acceptor bonding have an even stronger influence on the mK values [33]. The equimolar mixtures approach developed in Ref. [34] allows to determine the molar Kerr constant (mK), dipole moment (m), equilibrium constant (K) and, ultimately, structure of a molecular complex based on measurements of the Kerr constant (B), dielectric permittivity (e), density (d) and refractive index (n) of a series of dilute solutions of the complex. Future trends in the development of the electro-optical methods in chemistry are discussed. Theories that relate the electric-optic proprieties of molecules with their reactivity are particularly important. Such theories should be able to predict the changes in the polarizabilities and dipole moments of bonds, molecules and molecular aggregates during the course of chemical reactions.
Źródło:
Wiadomości Chemiczne; 2011, 65, 1-2; 1-31
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optyczno-elektroniczny sposób określania składu granulometrycznego gruntów i możliwości zastosowania w geologii inżynierskiej
Optical-electronic way of soil grain size composition determination and its possible application in engineering geology
Autorzy:
Kamiński, S.
Trzciński, J.
Powiązania:
https://bibliotekanauki.pl/articles/184093.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
skład granulometryczny
krzywa uziarnienia
system analizatorów optyczno-elektronicznych
pomiar wielkości cząstek
symulacja analizy sitowej i areometrycznej
analiza kształtu cząstek 3D
grain composition
grains-size distribution
Elsieve - system of optical-electronic analyzers
measurement of particles size
simulation of sieve and sedimentation analysis
3D analysis of particles' shape
Opis:
Obecnie istnieją już techniczne możliwości uniknięcia trudnych manualnie i pracochłonnych pomiarów składu granulometrycznego gruntów (np. analiza sitowa czy areometryczna). Parametr ten można badać za pomocą urządzeń optyczno-elektronicznych typu Elsieve, które coraz powszechniej używane są w Polsce. Takie urządzenia pomiarowe wykorzystuje się do wyznaczenia krzywej granulometrycznej ziaren o wymiarach od 0.5 mim do 100 mm. Dodatkowo istnieje możliwość określenia kształtu ziaren według pomiarów 3D oraz innych parametrów uziarnienia. System pomiarowy może składać się z dowolnej liczby urządzeń połączonych indywidualnie z komputerem rejestrującym. Każdy indywidualny komputer przyrządu pomiarowego połączony jest z komputerem centralnym pełniącym rolę serwera. Stworzona sieć komputerów pozwala jednocześnie rejestrować wyniki pomiarowe na komputerze obsługującym dane urządzenie pomiarowe, jak również na pozostałych komputerach. Taki system pomiarowy jest używany do badań uziarnienia gruntów i innych geomateriałów w laboratorium Instytutu Hydrogeologii i Geologii Inżynierskiej Wydziału Geologii UW.
Nowadays there are available technical possibilities to avoid manually difficult and work-consuming measurements of soil grain composition (e.g. sieve or sedimentation analysis). Such measurements can be replaced by optical-electronic instruments called Elsieve that are more common in Poland. The instruments are used for determination of grain-size distribution of gains and particles with diameter form 0.5 mim to 100 mm. Additionally there is possibility to determine shape of grains by 3D measurements and other graining parameters. The measuring system can consist of any number of instruments, connected with recording computer. Every computer of any measuring instruments is connected with the server. The created network allows to save measuring results at computer that works with particular instrument and at other computers. Such a system is used for measurements of soil and other geomaterials grain composition in laboratory at Institute of Hydrogeology and Engineering Geology, Faculty of Geology, University of Warsaw.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2008, 34, 4; 623-632
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A QMS-compliant multiparameter system for optical inspection of manufactured products
System wieloparametrycznej kontroli wyrobów w procesie produkcji z wykorzystaniem metod optycznej inspekcji przystosowanej do wymagań systemów zarządzania jakością
Autorzy:
Zając, J.
Małkiński, W.
Dworak, M.
Powiązania:
https://bibliotekanauki.pl/articles/256666.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
systemy wizji maszynowej
przetwarzanie obrazów
analiza obrazów
automatyczna inspekcja optyczna
swobodny spadek
akwizycja poruszających się obiektów
baza danych
system zarządzania jakością
machine vision systems
image processing
image analysis
automated optical inspection
free fall
acquisition of moving objects
database
quality management system
Opis:
The system described in this paper provides automated optical inspection of free-falling products. It was designed to inspect plastic nose pads for eyeglasses. The solutions relating to the integrated image acquisition and the processing and analysis techniques allow achieving high inspection efficiency. The system also assures the possibility of full archiving of the inspection results for further reference, processing or statistical analysis.
Opisany w artykule system automatycznej inspekcji optycznej przeznaczony jest do inspekcji jakości swobodnie spadających detali. Zrealizowano aplikację, w której inspekcji podlegają plastikowe noski do okularów. Zastosowane rozwiązania w zakresie akwizycji obrazów oraz technik przetwarzania i analizy umożliwiły uzyskanie dużej wydajności inspekcji. Opracowany system zapewnia również możliwość pełnego archiwizowania wyników inspekcji w celu późniejszego porównywania, przetwarzania czy analizy statystycznej.
Źródło:
Problemy Eksploatacji; 2006, 4; 215-230
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies