Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "open-circuit" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Open-circuit fault diagnosis in three-phase induction motor using model-based technique
Autorzy:
Aswad, Raya A. K.
Jassim, Bassim M. H.
Powiązania:
https://bibliotekanauki.pl/articles/949900.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
model-based diagnosis
number of turns
open-circuit fault
Opis:
The presence of an open-circuit fault subjects a three-phase induction motor to severely unbalanced voltages that may damage the stator windings consecutively causing total shutdown of systems. Unplanned downtime is very costly. Therefore, fault diagnosis is essential for making a predictive plan for maintenance and saving the required time and cost. This paper presents a model-based diagnosis technique for diagnosing an open-circuit fault in any phase of a three-phase induction motor. The proposed strategy requires only current signals from the faulty machine to compare them with the healthy currents from an induction motor model. Then the errors of comparison are used as an objective function for a genetic algorithm that estimates the parameters of a healthy model, which they employed to identify and localize the fault. The simulation results illustrate the behaviours of basic parameters (stator and rotor resistances, self-inductances, and mutual inductance) and the number of stator winding turn parameters with respect to the location of an open-circuit fault. The results confirm that the number of stator winding turns are the useful parameters and can be utilized as an identifier for an open-circuit fault. The originality of this work is in extracting fault diagnosis features from the variations of the number of stator winding turns.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 815-827
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of single and multiple IGBTs open-circuit faults in a field-oriented controlled induction motor drive
Autorzy:
Sobański, P.
Orłowska-Kowalska, T.
Powiązania:
https://bibliotekanauki.pl/articles/140648.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
field-oriented control
condition monitoring
open-circuit
fault
fault diagnosis
Opis:
In this paper a transistor open-circuit fault diagnosis method in a rotor field oriented controlled induction motor drive, fed by a two-level voltage inverter has been proposed. The diagnostic procedure ensures detection and localization of single or multiple power switch failures in time shorter than one period of a stator current fundamental harmonic, without regard to a drive operation point. A new simple scheme of the diagnostic system is proposed. In order to validate the proposed transistor fault diagnostic method, a detailed simulation as well as experimental tests of the field-oriented control drive system were carried out and some of them are shown in this paper.
Źródło:
Archives of Electrical Engineering; 2017, 66, 1; 89-104
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Microstructural Evolution on the Corrosion Resistance of Cold Drawn Copper Single Crystals in NaCl
Autorzy:
Koralnik, M.
Dobkowska, A.
Adamczyk-Cieslak, B.
Mizera, J.
Powiązania:
https://bibliotekanauki.pl/articles/353064.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
copper single crystal
microstructure evolution
texture evolution
impedance spectroscopy
potentiodynamic polarization
open circuit potential
Opis:
The aim of the present work was to determine the influence of the microstructural evolution of copper single crystals with the initial orientations of <001> and <111> after cold drawing on their corrosion resistance. Transmission electron microscopy, X-ray diffraction, and electron backscattering diffraction were used to characterize the microstructural changes. To evaluate the corrosion resistance after deformation, open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization analyses were conducted. The microstructural observations showed the presence of dislocation cell structures and shear bands indeformed sample with initial orientation <001> single crystal, as well as a strongly-developed substructure in sample <111>. The material with initial orientation of <001> was more resistive in analyzed medium than material with the initial orientation of <111>.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 1; 55-64
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault-tolerant control for three-phase three-level T-type inverters with a redundant leg
Autorzy:
Chen, Danjiang
Zheng, Liyuan
Powiązania:
https://bibliotekanauki.pl/articles/2172799.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault diagnosis
fault-tolerant control
open-circuit fault
phase-leg fault
redundant leg
T-type inverter
Opis:
Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 931--948
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Underwater Noises of Open-Circuit Scuba Diver
Autorzy:
Korenbaum, Vladimir
Kostiv, Anatoly
Gorovoy, Sergey
Dorozhko, Veniamin
Shiryaev, Anton
Powiązania:
https://bibliotekanauki.pl/articles/177264.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
underwater acoustics
diver
respiratory noises
noises of fins
open-circuit scuba
breathing apparatus
detection
monitoring
bearing
Opis:
The features of respiratory noises and noises of fins for open-circuit scuba divers, indicating a multipole character of noises emission, are specified in cameral conditions. It demonstrates a possibility to detect low-frequency components of noises of fins with pressure gradient sensor in near field. A possibility of estimating the respiratory rate of an open-circuit scuba diver is demonstrated at distances up to 100 m in real sea. It gives an opportunity of estimating the bearing (time delay in a pair of hydrophones) for the open-circuit scuba diver by respiratory noises at distances up to 150 m in real sea. Thus, low-frequency underwater noises of open-circuit scuba divers may be successfully applied to monitor the safety of diving and to prevent waterside intrusion by trespassers.
Źródło:
Archives of Acoustics; 2020, 45, 2; 349-357
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of T-type three-level inverter based on bridge voltages
Autorzy:
Chen, Danjiang
Liu, Yutian
Zhang, Shaozhong
Powiązania:
https://bibliotekanauki.pl/articles/1841372.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bridge voltage
fault diagnosis
fault signal
open-circuit fault
T-type three-level inverter
napięcie mostka
błędna diagnoza
sygnał błędu
błąd obwodu otwartego
falownik trójpoziomowy typu T
Opis:
Multilevel inverters have been widely used in various occasions due to their advantages such as low harmonic content of the output waveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, anda diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when anopen-circuit fault of the device occurred, and the effect on the circuit switching states andthe bridge voltages were analyzed. Then comprehensively considered the bridge voltages,and proposed a fault diagnosis method for a T-type three-level inverter based on specificfault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of theinverter device, and has the advantage of being easy to implement.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 73-87
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies