Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "open plan offices" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Study of the Acoustic Suitability of an Open Plan Office Based on STI and DL2 Simulations
Autorzy:
Passero, C. R. M.
Zannin, P. H. T.
Powiązania:
https://bibliotekanauki.pl/articles/178137.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
open plan offices
acoustic evaluation
acoustic improvement
Opis:
Many business offices around the world are organized as open plan offices. Therefore, studies about the acoustic comfort of the people who work in them have become increasingly important. The focus of this work is the acoustic evaluation of an open plan office combining several architectural characteristics and levels of ambient noise. This evaluation was performed through a computational model calibrated from a real office. The rate of spatial decay of sound pressure levels per distance doubling (DL2) and the speech transmission index (STI) were simulated for the acoustic evaluation of the office, allowing for the determination of the radius of distraction (rD). These parameters were simulated for 6 situations using different floor and ceiling covering materials and inserting or withdrawing screens between workstations. In addition, STI and rD were simulated under two conditions of ambient noise. The results indicated that the DL2 and rD are adequate acoustic parameters for the acoustic evaluation and improvement of an open plan office. The DL2 was strongly influenced by the presence or absence of screens between workstations and by the ceiling covering material. The rD was more sensitive to changes in ambient noise.
Źródło:
Archives of Acoustics; 2012, 37, 2; 237-243
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości akustycznej pomieszczeń biurowych typu open space z uwzględnieniem normy ISO 22955:2021
Evaluation of the acoustic quality of open plan offices spaces, taking into account the ISO 22955 standard
Autorzy:
Mikulski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/31342480.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
akustyka pomieszczeń
biura open space
hałas
chłonność akustyczna
czas pogłosu
room acoustics
open plan offices
noise
sound absorption
reverberation time
Opis:
W PN-B-2151-4:2015 wyróżnia się dwa typy wielkopowierzchniowych pomieszczeń pracy: grupę 1 - pomieszczenia biurowe open space (inaczej zwane otwartymi pomieszczeniami do prac administracyjnych), sale operacyjne banków i urzędów, biura obsługi klienta, oraz grupę 2 - centra obsługi telefonicznej. W każdej z tych grup określona jest minimalna chłonność akustyczna pomieszczenia. W PN-EN ISO 3382-3:2012 wprowadzono cztery inne kryteria akustyczne pomieszczeń, dotyczące grupy 2. Do stanowisk pracy lub wymienionych pomieszczeń odnoszą się także kryteria związane z dopuszczalnym hałasem, określone w PN-N-01307:1994 oraz PN-B-02151-2:2018. Omawiane kryteria opracowano od 28 do czterech lat wstecz i w wielu przypadkach nie są one w pełni dostosowane do obecnie eksploatowanych pomieszczeń. Skutkiem tego było wprowadzenie w nowej normie ISO 22955:2021 nowego podziału wielkopowierzchniowych pomieszczeń pracy na sześć klas, w tym klasy pomieszczeń przeznaczonych do pracy biurowej, ale bez wyposażenia. W artykule omówiono wymagania oraz podano kryteria oceny pomieszczeń biurowych open space według ISO 22955:2021 oraz norm: PN-N-01307, PN-B-02151-2, PN-B-02151-4 i PN-EN ISO 3382-3.
The Polish standard PN-B-02151-4: 2015 distinguishes two types of large-area work rooms: 1 - open plan offices, operating rooms for banks and offices, customer service offices and 2 - call centres. In each of these types, criteria for the minimum sound absorption of the room are defined. The PN-EN ISO 3382-32012 specifies four other acoustic criteria for rooms, but referring only to rooms type 2. For workplaces or the above-mentioned the rooms are also subject to the criteria for permissible noise specified in the PN-N-01307:1994 and the PN-B-02151-2:2018 standards. Above the criteria were developed from 28 to 4 years ago and in many cases are not fully adapted to the currently used rooms. As a result, the new ISO 22955: 2021 introduced a new division of open plan offices spaces/rooms. There are five types of used rooms and an additional class i.e. a room intended for office work, but without equipment. The article will discuss the acoustic requirements and the evaluation criteria of the rooms according to ISO 22955:2021 and the standards: PN-N-01307, PN-B-02151-2, PN-B-02151-4 and PN-EN ISO 3382-3.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2022, 12; 22-27
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ dźwięku maskującego na zrozumiałość niepożądanych dźwięków mowy w biurach typu open space - wyniki badań własnych
The impact of sounds masking speech intelligibility on acoustic environment in open plan offices
Autorzy:
Mikulski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/2202795.pdf
Data publikacji:
2020
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
akustyka pomieszczeń
czas pogłosu
chłonność akustyczna
wskaźnik transmisji mowy STI
dźwięki maskujące
biura open space
room acoustic
reverberation time
sound absorption
speech transmission index STI
masking sounds
open plan offices
Opis:
W artykule przedstawiono wyniki badania obliczeniowego, wpływu zastosowania dźwięków maskujących na zrozumiałość mowy na stanowiskach pracy w typowym pomieszczeniu biurowym open space. Jako dźwięki maskujące uwzględniono dźwięki o czterech charakterach widm częstotliwości i o poziomach dźwięku A z zakresu 25-45 dB. Kryteria oceny akustycznej biurowych pomieszczeń open space przyjęto wg PN-EN ISO 3382-3:20121 i PN -8-02151-4:2015 (właściwości akustyczne pomieszczenia) oraz PN-B-02151-2:2Q18 (poziom tła akustycznego, w tym i dźwięku maskującego). Wykazano, że jest możliwe uzyskanie odpowiednich warunków środowiska pracy (w tym własności akustycznych pomieszczenia) przy poziomie dźwięku A dźwięku maskującego z zakresu31-37dB (w zależności od rozpatrywanego jednego z czterech typów charakteru widma dźwięku maskującego).
The article presents computational research results of the impact of the use of sounds masking speech intelligibility at workplaces located in typical open plan office areas. Four types of masking sounds at frequency spectrum and A-weighted sound pressure levels within the range of 25-45 d8 were used. The criteria for the acoustic evaluation of open plan office rooms were adopted according to the EN ISO 3382-3:2012 and the Polish standards: PN-B-02151-4:2015 (room acoustic properties) and PN-B-02151-2: 2018 (background level, including masking sound). It has been shown that it is possible to obtain appropriate work environment conditions (including room acoustic properties) at the A-weighted sound pressure level of masking sound in the range of 31-37 dB (depending on the one of the four types of masking frequency spectrum considered).
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2020, 12; 22-26
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies