Tytuł:
Dedicated computer software to radiation dose optimization for the staff performing nuclear medicine procedures
Autorzy:
Matusiak, K.
Kosek, J.
Powiązania:
https://bibliotekanauki.pl/articles/146774.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dose optimization
nuclear medicine
radiation protection
Opis:
Nuclear medicine techniques allow physicians to observe and diagnose physiology of chosen organs as well as the whole body of a patient. This visualization is possible not only because radioisotopes are applied, but there is also a significant progress in the computer software possibility. The advantage of the cooperation between medicine and informatics can be implemented in the radiation protection field of medical staff. The presented computer software, so-called Optimizer, was dedicated to the medical staff responsible for radiopharmaceutical preparation. It is known that the doses obtained in the nuclear medicine "hot labs" can be higher in comparison with the doses obtained by the rest of the personnel in the same department. The main advantage of the presented program is that the time needed for radiopharmaceutical preparation can be shortened and, as a result, the doses absorbed by personel can be reduced. The information of the volume containing planned radioactivity at the time of the application can significantly reduce the number of checking (volume and radioactivity), which normally takes place before the final handing over the radiopharmaceutical to the application. A user-friendly interface provides control at each step of the preparation protocol. For the convenience of medical staff all current examinations were coloured in one of the three colours : red (an application has to be done now), yellow (waiting) and green (done). The Optimizer was created for the Nuclear Medicine Department in the 5th Military Hospital in Kraków (Poland). What is more, currently it is successfully used and final TLD (thermoluminescent dosimetry) tests have been performed.
Źródło:
Nukleonika; 2012, 57, 4; 497-502
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the current status and potential of nuclear medicine in Poland
Autorzy:
Pachocki, K.A.
Sackiewicz-Slaby, A.
Powiązania:
https://bibliotekanauki.pl/articles/874296.pdf
Data publikacji:
2013
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
present state
potential
nuclear medicine
radioisotope method
procedure
Polska
Opis:
Background. Through its use of ionising radiation, the field of nuclear medicine forms a unique and significant part of medical diagnostics and patient treatment. Objectives. To assess the operational potential of nuclear medicine in Poland based on existing database/literature sources together with conducting a survey on the relevant healthcare facilities available, staffing, expertise and performance. Material and Methods. To gather all available literature data on the medical use of ionising radiation in Poland several data bases were used, since currently, there are no single statistical data base devoted to this issue. Data on radiation hygiene were thus collected from the Statistical Bulletin of the Ministry of Health, Annual reports from the National Atomic Energy Agency and Central Statistics Office. Additionally, national and provincial reports were used, as well as those received from the European Society of Nuclear Medicine. Results. At present, the Public Healthcare system in Poland has 55 nuclear medicine departmental facilities operating and 8 that are private/non-public. These are staffed by 252 doctors, of whom 151are qualified as nuclear medicine specialists; constituting one specialist per 300,000 inhabitants. In addition, 170 highly qualified staff (biologists, chemists, physicists, electronics engineers and IT specialists) provide indispensable scientific/operational support and are vital for the development of nuclear medicine departments. They are mainly responsible for ensuring that all equipment functions effectively and for developing new diagnostic techniques, together with new radiopharmaceuticals. Furthermore, there are approximately 500 other staff at intermediate-level also involved in nuclear medicine departments, such as technicians, nurses and support workers. The survey demonstrated an average of 22 persons employed per nuclear medicine department. For all institutions, it is estimated that there are 127 gamma cameras, 10 PET/CT scanners and 16 hybrid SPECT/CT systems operating. In 2000, approximately 117,435 diagnostic procedures were performed, compared to 156,214 in 2008 and with the current number of around 170,000; up to 38% were simple thyroid scintigraphies, 25% were bone scans, 11% heart scintigraphies and 10% kidney scans. Conclusions. The number of diagnostic radioisotopic procedures in Poland are strongly expected to increase by 300% during the next 5-6 years. To meet this rise, additional equipment will thus be necessary, which includes having an extra 100 SPECT/CT gamma cameras.
Wprowadzenie. Stosując promieniowanie jonizujące medycyna nuklearna stanowi istotną i unikalną gałąź metod diagnostycznych i leczniczych. Cel badań. Celem podjętych badań było zebranie danych, na bazie dostępnych danych literaturowych oraz przeprowadzonego badania ankietowego i ocena potencjału w zakresie personelu i aparatury itp. jakim dysponuje medycyna nuklearna w Polsce. Materiał i metoda. W celu zebrania niezbędnych danych, ze względu na brak jednej statystycznej bazy danych dotyczącej medycznych zastosowań promieniowania jonizującego w Polsce, korzystano z kilku istniejących baz danych. Dane dotyczące higieny radiacyjnej pochodziły z Biuletynu Statystycznego Ministerstwa Zdrowia, Rocznych Raportów Państwowej Agencji Energii Atomowej i Głównego Urzędu Statystycznego. Dodatkowo korzystano z krajowych i wojewódzkich raportów oraz danych Europejskiego Towarzystwa Medycyny Nuklearnej. Wyniki. W Polsce funkcjonuje 55 zakładów medycyny nuklearnej działających w ramach publicznej służby zdrowia oraz 8 ośrodków niepublicznych. Obecnie w obszarze medycyny nuklearnej pracuje ok. 252 lekarzy, w tym ok. 151 posiadających specjalizację z zakresu medycyny nuklearnej. Oznacza to, że jeden lekarz specjalista przypada na 300 000 mieszkańców. W zakładach medycyny nuklearnej zatrudnionych jest także ok. 170 osób z wyższym wykształceniem (m.in. biolodzy, chemicy, fizycy, elektronicy, informatycy). Jest to grupa pracowników ważna dla rozwoju placówek medycyny nuklearnej, zajmująca się sprawnością aparatury, rozwojem nowych technik diagnostycznych oraz rozwojem radiofarmaceutyków. Personel średni (technicy i pielęgniarki) zatrudniony w pracowniach medycyny nuklearnej oraz personel pomocniczy szacuje się na ok. 500 pracowników. Z przeprowadzonych badań ankietowych wynika, iż średnio w zakładzie medycyny nuklearnej pracują 22 osoby. Szacuje się, że w placówkach tych funkcjonuje 127 gamma kamer, 10 skanerów PET/CT i 16 systemów hybrydowych SPECT/CT. W roku 2000 wykonano około 117 435 badań diagnostycznych, natomiast w roku 2008 liczba ta wzrosła do ok. 156 214 badań, z czego aż 38% stanowiły najprostsze badania scyntygraficzne tarczycy, 25% badania scyntygraficzne kości, 11% badania serca i 10% badania nerek. W Polsce obecnie z zakresu medycyny nuklearnej wykonuje się ok. 170 tys. badań rocznie. Wnioski. Liczba wykonywanych w Polsce diagnostycznych badań radioizotopowych powinna w ciągu 5-6 lat wzrosnąć o 300%. Konieczny będzie zakup dodatkowego sprzętu i aparatury, m.in. gamma kamer typu SPECT/CT w ilości ok. 100 aparatów.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2013, 64, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to ionizing radiation by service personnel working with cyclotrons used to produce radiopharmaceuticals in PET diagnostics
Autorzy:
Biegała, Michał
Jakubowska, Teresa
Wrzesień, Małgorzata
Albiniak, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2152980.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nuclear medicine
PET
equivalent dose
service
radiological protection
cyclotron
Opis:
Objectives While working with cyclotrons used for the production of radiopharmaceuticals, workers can experience significant exposure to the adverse effects of ionizing radiation. The aim of this paper was to determine the typical level of such exposure received by such personnel while servicing cyclotrons. Material and Methods Exposure was assessed using TLD detectors placed in an anthropomorphic phantom, as well as dose meter to determine whole body and eye lens exposure. The phantom was placed in locations receiving the greatest exposure to ionizing radiation during service activities. The time spent by employees during servicing was assessed based on routine visits by service technicians. The obtained results were compared with readings of detectors worn by employees during service activities. Results The highest equivalent doses in the thoracic area were found to be received by the lungs (211.16 μSv/year). In the head and neck area, the highest dose was measured in the eye lens (3410 μSv/year). The effective dose for the whole body was found to be 1154.4 μSv/year, based on the phantom, and 149 μSv per service visit (1192 μSv/year), based on the dose meters carried by the workers. Conclusions Service workers are exposed to significant doses of ionizing radiation, representing a clear radiological protection issue. To reduce exposure to eye lenses, it is recommended to use protective goggles when working with highly-radioactive elements.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 6; 753-760
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration of thermoluminescent detectors in Hp(0.07) units by using an X-ray tube and a ¹³⁷Cs source
Autorzy:
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2164013.pdf
Data publikacji:
2019-12-03
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
thermoluminescence
Hp(0.07)
calibration
X-ray
Dosimetry
nuclear medicine
Opis:
Background The method of measuring doses based on the thermoluminescence phenomenon is not an absolute method. For this reason, to obtain correct results, it is necessary to calibrate detectors in the known radiation field. This paper presents a method for calibrating thermoluminescent detectors used in the measurement of personal dose equivalents (Hp(0.07)) obtained by nuclear medicine facility personnel when handling the $\text{}^{99m} \text{Tc}$ radionuclide. Material and Methods The authors used self-developed high-sensitivity thermoluminescent detectors and a HF320C X-ray unit, as well as a rod phantom. Dosimeters were calibrated in accordance with the ISO 4037-3 standard. During the measurements a vial containing a $\text{}^{99m} \text{Tc}$ radionuclide with well-known activity was also used. The energy characteristics were supplemented by using a ¹³⁷Cs source (irradiator ⁶⁰Co/¹³⁷Cs). Results The value of the calibration coefficient for 118 keV energy energy was (1.90±0.02)×10⁻⁵ mSv/imp. Taking into account the correction factor specified for of 140 keV energy at 0.962, the value of the calibration coefficient for 140 keV energy was determined as (1.83±0.02)×10⁻⁵ mSv/imp. Conclusions Verification of the calibration coefficient determined for 140 keV energy carried out with a vial containing a $\text{}^{99m} \text{Tc}$ radionuclide confirmed the correctness of the procedure. Med Pr. 2019;70(6):669–73
Źródło:
Medycyna Pracy; 2019, 70, 6; 669-673
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instrumenty zarządzania w ochronie środowiskowej
Management Instruments in Environmental Protection
Autorzy:
Olkiewicz, M.
Bober, B.
Majchrzak-Lepczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818524.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ryzyko
zarządzanie
medycyna nuklearna
ochrona środowiska
risk
management
nuclear medicine
environmental protection
Opis:
The article presents the instruments for the assessment of environmental protection – the risk of nuclear medicine in the entities. Streamlining of processes in health care entities is the determinant of the concept of process management. It is based on the implementation of significant changes in the course of diagnostic and therapeutic processes, which result in their efficiency is raised (a measure of the cost and time), flexibility (the ability to process an adequate response of the body of the patient). Analyses show that the implementation of a comprehensive process approach to risk management and environmental protection can bring many tangible benefits to operators of nuclear medicine. Where the process of elimination of risk is not possible, they should be restricted, and the risk of residual control. Development of systems for environmental protection and risk assessment is never ending – is doomed to evolution. Factor causing this situation is the fact that they reflect the diagnostic and therapeutic subprocesses managing the process of providing medical services, they are also an expression of the attitude of the medical community conditioned the current state of knowledge.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 710-725
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cezary Pawłowski (1895-1981) radiolog, konstruktor, organizator, profesor
Cezary Pawłowski (1895-1981) radiologist, constructor, organizer, professor
Autorzy:
Marusak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1203118.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
radiologia
medycyna nuklearna
miernictwo radiologiczne
elektromedycyna
radiology
nuclear medicine
radiological metrology
biomedical engineering
Opis:
Cezary Pawłowski was a polish physicist, a specialist in radiology, radiological measurement, radiological protection, and electromedicine. He was born in Łomża, Poland, and died in Warsaw. He finished studies in Math-Phys Department at Odessa University in 1933. He received PhD and DSc degrees at the Warsaw University in 1926 and 1933, respectively, and the title of Professor — from University of Poznań (1946). He was a student of Professor Mary Skłodowska-Curie in Paris, as a French Government's scholar (1927- 1931). He became, with her recommendation, a chief of Physical Laboratory (1934) of Radium Institute in Warsaw. This Laboratory soon became a significant scientific center of the world. During German occupation (1939-1945) he made measurements of X-ray Radiation in hospitals and centers of health, and he also led secret teaching of university students. He had worked at Electric Department of Warsaw University of Technology, and he had starteded education in Biomedical Engineering from 1946, as the first in the world. He designed technology of production of Geiger counters and the radium beam radio-curie-therapy apparatus. He was a dean of Communication Department at WUT.
Cezary Pawłowski był polskim fizykiem, specjalistą w dziedzinie radiologii ogólnej i przemysłowej, miernictwie radiologicznym, ochronie radiologicznej oraz elektromedycynie. Urodzony w Łomży, studia ukończył na Wydziale Matematyczno-Fizycznym Uniwersytetu w Odessie. Doktorat (1926) w zakresie fizyki i habilitację (1933) uzyskał na Uniwersytecie Warszawskim, a tytuł profesora (1946) — na Uniwersytecie Poznańskim. Był uczniem Marii Skłodowskiej-Curie. Pracował w Jej laboratorium w Paryżu jako stypendysta rządu francuskiego (1927-1931). Z Jej rekomendacji, został kierownikiem Pracowni Fizycznej Instytutu Radowego w Warszawie powstającego wówczas (1934). Pracownia ta w krótkim czasie, stała się znaczącym ośrodkiem naukowym na świecie. W czasie okupacji niemieckiej (1939-1945) wykonywał pomiary promieniowania rentgenowskiego w szpitalach i w ośrodkach zdrowia oraz prowadził tajne nauczanie młodzieży akademickiej. Od roku 1946 pracował na Wydziale Elektrycznym Politechniki Warszawskiej (PW) i zorganizował pierwszą na świecie sekcję "Elektromedycyny". Opracował technologię produkcji liczników Geigera-Mullera i tzw. bombę radową, czyli aparat do radio-curie-terapii. Był dziekanem Wydziału Łączności PW.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 4, 116; 35-38
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie technik medycyny nuklearnej w ortopedii
Application of nuclear medicine techniques in orthopedics
Autorzy:
Cegła, Paulina
Kostiukow, Anna
Pietrasz, Katarzyna
Cholewiński, Witold
Powiązania:
https://bibliotekanauki.pl/articles/986641.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
ortopedia
obrazowanie
medycyna nuklearna
scyntygrafia
SPECT-CT
PET-CT
orthopedy
diagnosis
nuclear medicine
scintigraphy
Opis:
Główną zaletą obrazowania z zastosowaniem technik medycyny nuklearnej jest możliwość uchwycenia zmian funkcjonalnych, które pojawiają się przed zmianami anatomicznymi. W związku z tym wykorzystanie technik medycyny nuklearnej umożliwia wczesne wykrycie m.in. chorób układu mięśniowo-szkieletowego.
The major advantage of nuclear medicine imaging is that functional changes appear before an anatomical change. Therefore, imaging in nuclear medicine enables the early detection of diseases of the musculoskeletal system.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 2; 133-139
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of Reaching the Regulatory Limit for the Release of Radioactive Liquid Waste in Nuclear Medicines
Autorzy:
Alfayyadh, Linda
Naimi, Sepanta
Mizban, Fadhil
Al-Hamami, Naheel
Alguraibawi, Marwah
Powiązania:
https://bibliotekanauki.pl/articles/24201728.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
radioactive iodine
I-131
liquid waste
storage system
decay system
nuclear medicine
authorisation limit
Opis:
The research was conducted at one of Iraq’s nuclear medical facilities in Baghdad, which uses radioactive iodine (I-131) to treat thyroid patients, the major purpose of this research was to meet the national legal limit for the release of radioactive liquid waste into the environment, a high purity germanium reagent radiation detector was used to evaluate nine iodine I-131 samples. From 2021 and 2023, the concentration of waste prior to storage and disposal was between 24498 Bq/L and 5.7 Bq/L. Short-lived radionuclides, such as I-131 with an 8.04-day half-life, may be released into the sewage system in line with Iraq’s Nationally Approved Limits and Austria’s International Atomic Energy Agency (IAEA). Moreover, it is stored for 10 times the half-life, or four months, until the choice to release it into the environment is made.
Źródło:
Journal of Ecological Engineering; 2023, 24, 5; 329--336
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PET/CT w diagnostyce guzów mózgu
PET/CT imaging in the diagnosis of brain tumors
Autorzy:
Cegła, P.
Adamska, K.
Smoleń, M.
Pachowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/112371.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
diagnostyka medyczna
guzy mózgu
medycyna nuklearna
PET-CT
onkologia
diagnostic
brain tumors
nuclear medicine
oncology
Opis:
Wczesna diagnostyka zmian guzów zlokalizowanych w ośrodkowym układzie nerwowym jest bardzo istotna. Podstawowymi badaniami obrazowymi w diagnostyce guzów mózgu są tomografia komputerowa (TK) oraz rezonans magnetyczny (MR). Pomimo wykorzystania tych metod wykrywanie wznowy miejscowej oraz odróżnienie jej od zmian wywołanych zastosowanym leczeniem jest bardzo trudne. Obrazowanie z wykorzystaniem technik medycyny nuklearnej stanowi uzupełnienie do podstawowych metod obrazowania guzów ośrodkowego układu nerwowego (OUN). Po wprowadzeniu 18F-fluorodeoxyglukozy (18F-FDG) do diagnostyki i wykazaniu wartości diagnostycznej z użyciem tego znacznika, obrazowanie w neurologii stało się jednym z ważniejszych obszarów jego wykorzystania. Ze względu na wysoki fizjologiczny metabolizm glukozy w tkance mózgowej i związany z tym wysoki wychwyt FDG w obrębie mózgowia, wykrycie i zróżnicowanie zmian nowotworowych w ośrodkowym układzie nerwowym jest utrudnione. Wykorzystanie innych radiofarmaceutyków i obrazowania techniką pozytonowej tomografii emisyjnej PET (Positron Emission Tomography) pozwala na wykrycie hipoksji, dostarcza informacji na temat przemian biochemicznych aminokwasów lub proliferacji komórkowej. Dzięki temu zwiększa się czułość w diagnostyce guzów mózgu oraz poprawia ocena odpowiedzi na leczenie czy wczesnym wykrywaniu wznowy. W niniejszej pracy przedstawiono metody obrazowania guzów ośrodkowego układu nerwowego z użyciem techniki PET/CT.
Early diagnostic is critical in central nervous system tumors. Primary imaging modalities in brain tumors are computed tomography (CT) and magnetic resonance (MR). Despite use of these methods recurrence detection and differentiation between tumor and post-therapeutic changes is still challenging. Nuclear medicine modalities provide additional information unavailable in CT or MRI imaging. After FDG introduction the diagnostic value of this radiotracer was quickly proven and ever since positron emission tomography (PET) has become one of most important tools in brain tumor management. Due to the high physiologic activity of 18F-FDG in healthy brain tissue, it is difficult to differentiate the lesions within the brain. Positron emission tomography using other markers visualizing hypoxia, aminoacids metabolism or proliferation increases the sensitivity of brain tumor diagnostics and follow-up of the treated area to detect early recurrence. The paper presents methods for imaging central nervous system tumors using the PET/CT.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 5; 305-309
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieorganiczne nanocząstki w medycynie nuklearnej
Inorganic nanoparticles in nuclear medicine
Autorzy:
Kasperek, A.
Bilewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/172564.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
nanocząstki
medycyna nuklearna
system transportu leków
nośniki leków
nanoparticles
nuclear medicine
drug delivery systems
drug carriers
Opis:
Rapid and widespread growth in the use of nuclear medicine for both diagnosis and therapy of disease has been the driving force for a design of novel radiopharmaceuticals. Particularly, recent progress in nanotechnology gives the possibility of designing new carriers for delivering radionuclides in a manner to overcome some limitation such as nonspecific biodistribution and targeting, water insolubility, poor oral bioavailability and others. There are several perspective therapeutic and diagnostic radionuclides which cannot be bound to biomolecule via chemical bonds. Nanocarriers gives the opportunity for binding such radionuclides. Nanoparticles have to be designed with an optimal size (above 100 nm) and surface characteristic to easily penetrate the barriers in the body and prevent elimination by reticuloendothelial system. Among nanoparticles which are used for delivery and targeting are polymers, lipids, viruses, organometallic compounds, precious metals or metal oxides. This article presents a brief review of the applications, advantages, difficulties and future perspective of inorganic nanoparticles, which can be used as radionuclide delivery systems. The main direction of developing new nanostructures for nuclear medicine is to create multimodal agents which are suitable for such combined methods as PET /MRI or PET /NIRF. Also combination of diagnostic and therapeutic agents in one nanocontainer is possible.
Źródło:
Wiadomości Chemiczne; 2012, 66, 7-8; 697-714
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prostota czy złożoność procesu wytwarzania radiofarmaceutyków w świetle optymalizacji ochrony radiologicznej personelu – $ \text{}^\text{99m}\text{Tc} $ vs $ \text{}^\text{18}\text{F} $
Simplicity or complexity of the radiopharmaceutical production process in the light of optimization of radiation protection of staff – $ \text{}^\text{99m}\text{Tc} $ vs $ \text{}^\text{18}\text{F} $
Autorzy:
Wrzesień, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2162470.pdf
Data publikacji:
2018-05-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
medycyna nuklearna
detektor termoluminescencyjny
optymalizacja
radiofarmaceutyk
izotop
dawka równoważna
nuclear medicine
thermoluminescent detector
optimization
radiopharmaceutical
isotope
equivalent dose
Opis:
Wstęp Radiofarmaceutyk to produkt będący połączeniem niepromieniotwórczego związku chemicznego i znacznika izotopowego. Na bogatej liście izotopów mających zastosowane w medycynie na uwagę zasługują 2 – technet-99m ($ \text{}^\text{99m}\text{Tc} $) i fluor-18 ($ \text{}^\text{18}\text{F} $). Ich podobieństwo ogranicza się jedynie do diagnostycznego obszaru stosowalności, a dzieli je m.in. rodzaj i energia emitowanego promieniowania, czas połowicznego rozpadu czy w szczególności sposób produkcji. Izotop $ \text{}^\text{99m}\text{Tc} $ uzyskuje się dzięki generatorom nuklidów krótkożyciowych – molibdenu-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, a $ \text{}^\text{18}\text{F} $ powstaje w reakcji jądrowej zachodzącej w cyklotronie. Stosunkowo łatwy sposób obsługi generatora $ \text{}^\text{99}\text{Mo} $/$ \text{}^\text{99m}\text{Tc} $ w porównaniu z koniecznością wykorzystania cyklotronu wydaje się sprzyjać zasadzie optymalizacji ochrony radiologicznej personelu. Weryfikacja tezy dotyczącej wpływu automatyki zarówno produkcji znacznika $ \text{}^\text{18}\text{F} $, jak i procesu znakowania deoksyglukozy na zoptymalizowanie ochrony radiologicznej pracowników w porównaniu z manualnymi procedurami wykonywanymi podczas znakowania preparatów izotopem $ \text{}^\text{99m}\text{Tc} $. Materiał i metody Dawki równoważne Hp(0,07) zmierzono w 5 zakładach medycyny nuklearnej i 2 ośrodkach produkujących znaczniki pozytonowe, w szczególności $ \text{}^\text{18}\text{F} $. W pomiarach dozymetrycznych wykorzystano wysokoczułe detektory termoluminescencyjne wykonane z fluorku litu (LiF: Mg, Cu, P – MCP-N). Wyniki Wśród czynności wykonywanych przez pracowników zarówno placówek produkujących $ \text{}^\text{18}\text{F} $-fluorodeoksyglukozę ($ \text{}^\text{18}\text{F} $-FDG), jak i zakładów medycyny nuklearnej manualne procedury kontroli jakości oraz znakowanie preparatu mają największy wkład do zarejestrowanych wartości dawek Hp(0,07). Wnioski Prosty sposób uzyskania znacznika $ \text{}^\text{99m}\text{Tc} $ podobnie jak złożony (choć w pełni zautomatyzowany) proces produkcji $ \text{}^\text{18}\text{F} $-FDG optymalizuje ochronę radiologiczną personelu z wyłączeniem manualnych procesów znakowania związków chemicznych $ \text{}^\text{99m}\text{Tc} $ bądź kontroli jakości $ \text{}^\text{18}\text{F} $-FDG. Med. Pr. 2018;69(3):317–327
Background A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium- 99m ($ \text{}^\text{99m}\text{Tc} $) and fluorine-18 ($ \text{}^\text{18}\text{F} $) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The $ \text{}^\text{99m}\text{Tc} $ isotope is produced by a short-lived nuclide generator – molybdenum-99 ($ \text{}^\text{99}\text{Mo} $)/$ \text{}^\text{99m}\text{Tc} $, while $ \text{}^\text{18}\text{F} $ is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the $ \text{}^\text{99}\text{Mo} $ \text{}^\text{99m}\text{Tc} $ generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the $ \text{}^\text{18}\text{F} $ isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with $ \text{}^\text{99m}\text{Tc} $ need to be verified. Material and Methods Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P – MCP-N) were used to determine the doses. Results Among the activities performed by employees of both $ \text{}^\text{18}\text{F} $-fluorodeoxyglucose ($ \text{}^\text{18}\text{F} $-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with $ \text{}^\text{99m}\text{Tc} $ isotope manifest the greatest contribution to the recorded Hp(0.07). Conclusions The simplicity of obtaining the $ \text{}^\text{99m}\text{Tc} $ isotope as well as the complex, but fully automated production process of the $ \text{}^\text{18}\text{F} $-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with $ \text{}^\text{99m}\text{Tc} $ or quality control of $ \text{}^\text{18}\text{F} $-FDG. Med Pr 2018;69(3):317–327
Źródło:
Medycyna Pracy; 2018, 69, 3; 317-327
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na promieniowanie jonizujące techników obsługujących gammakamery
Evaluation of exposure to ionizing radiation among gamma camera operators
Autorzy:
Domańska, Agnieszka A.
Bieńkiewicz, Małgorzata
Olszewski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2166788.pdf
Data publikacji:
2014-11-04
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
promieniowanie jonizujące
medycyna nuklearna
dozymetria
dawka graniczna
ochrona radiologiczna
personel medyczny
ionizing radiation
nuclear medicine
Dosimetry
dose limit
radiation protection
medical staff
Opis:
Wstęp: Ochrona personelu placówki medycyny nuklearnej przed zagrożeniami wynikającymi ze stosowania promieniowania jonizującego jest istotnym aspektem ochrony radiologicznej osób fizycznych. Celem pracy była oceny narażenia zawodowego techników elektroradiologii wykonujących badania scyntygraficzne w Zakładzie Medycyny Nuklearnej Centralnego Szpitala Klinicznego UniwersytetuMedycznego w Łodzi, gdzie rocznie przeprowadzanych jest kilka tysięcy różnego rodzaju radioizotopowych badań diagnostycznych. Materiał i metody: W badanej placówce diagnostycznej zatrudnionych jest 10 techników (2013 r.), których narażenie podlega stałej kontroli za pomocą dozymetrii indywidualnej. Zebrano archiwalne dane dotyczące kwartalnych odczytów z dozymetrów na przestrzeni lat 2001-2010 i przeanalizowano dawki kwartalne wyrażone, jako równoważniki dawki Hp(10). Wyznaczono również dawki roczne oraz 5-letnie, odnosząc wyniki do obecnie obowiązujących norm prawnych. Dla wybranego okresu jednego roku zebrano również dane dotyczące liczby i rodzaju realizowanych w tym czasie badań, aby ocenić, czy istnieje zależność między łączną aktywnością radiofarmaceutyków podaną w tym czasie pacjentom a dawkami zarejestrowanymi u techników wykonujących te badania. Wyniki: W badanym 10-letnim okresie działalności placówki, najwyższa zarejestrowana u technika dawka roczna wynosiła 2 mSv, a najwyższa sumaryczna dawka 5-letnia - 7,1 mSv, co nie przekraczało 10% wartości granicznych dawki rocznej (20 mSv) i 5-letniej (100 mSv). Zaobserwowano dodatnią zależność liniową między wartościami kwartalnych dawek otrzymanych przez techników a łączną aktywnością radiofarmaceutyków podanych w tym okresie pacjentom. Wnioski: Przy zachowaniu zasad ochrony radiologicznej oraz warunków bezpiecznego stosowania promieniowania jonizującego dawki otrzymywane przez techników wykonujących badania scyntygraficzne są niskie, co potwierdza zaliczenie tej grupy zawodowej do pracowników kategorii B. Med. Pr. 2013;64(4):503–506
Background: Protection of nuclear medicine unit employees from hazards of the ionizing radiation is a crucial issue of radiation protection services. We aimed to assess the severity of the occupational radiation exposure of technicians performing scintigraphic examinations at the Nuclear Medicine Department, Central Teaching Hospital of Medical University in Łódź, where thousands of different diagnostic procedures are performed yearly. Materials and Methods: In 2013 the studied diagnostic unit has employed 10 technicians, whose exposure is permanently monitored by individual dosimetry. We analyzed retrospective data of quarterly doses in terms of Hp(10) dose equivalents over the years 2001-2010. Also annual and five-year doses were determined to relate the results to current regulations. Moreover, for a selected period of one year, we collected data on the total activity of radiopharmaceuticals used for diagnostics, to analyze potential relationship with doses recorded in technicians performing the examinations. Results: In a 10-year period under study, the highest annual dose recorded in a technician was 2 mSv, which represented 10% of the annual dose limit of 20 mSv. The highest total dose for a 5-year period was 7.1 mSv, less than 10% of a 5-year dose limit for occupational exposure. Positive linear correlation was observed between total activity of radiopharmaceuticals used for diagnostics in the period of three months and respective quarterly doses received by technicians performing examinations. Conclusions: Doses received by nuclear medicine technicians performing diagnostic procedures in compliance with principles of radiation protection are low, which is confirmed by recognizing the technicians of this unit as B category employees. Med Pr 2013;64(4):503–506
Źródło:
Medycyna Pracy; 2013, 64, 4; 503-506
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of exposure of workers to ionizing radiation from radioiodine and technetium in nuclear medicine departmental facilities
Ocena narażenia pracowników na promieniowanie jonizujące radiojodu i technetu w zakładach medycyny nuklearnej
Autorzy:
Krajewska, Grażyna
Pachocki, Krzysztof A.
Powiązania:
https://bibliotekanauki.pl/articles/2166302.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
radiojod 131I
technet 99mTc
medycyna nuklearna
dawka skuteczna
ekspozycja zawodowa
radioiodine 131I
technetium 99mTc
nuclear medicine
effective dose
occupational exposure
Opis:
Background: Due to its use of ionising radiation, the field of nuclear medicine is a unique and significant part of medical diagnostics and patient treatment. The aim of this study was to assess the internal exposure of nuclear medicine employees to radioiodine 131I and technetium 99mTc as well as to assess the external exposure doses. Material and Methods: The radioiodine 131I and technetium 99mTc contents in the thyroid of staff members (about 100 persons) dealing with these radionuclides have been measured in four departments of nuclear medicine. The measurements were conducted with a portable detection unit for in situ measurements of radioiodine and technetium. High sensitivity environmental thermoluminescent dosimeters (TLD) were used to measure the external exposure dose. Results: The average values and ranges of radioiodine 131I activity measured in the thyroids of all of the medical units' employees were: 83 Bq (range: 70-250 Bq), 280 Bq (range: 70-4000 Bq), 275 Bq (range: 70-1000 Bq) for technical staff, nuclear medicine staff and hospital services staff, respectively. The mean value of technetium 99mTc content in the thyroids of nuclear medicine staff was approximately 1500 Bq (range: 50- -1800 Bq). External exposure dose rates were in the range of 0.5-10 μGy/h. Conclusions: The calculated average effective dose for particular person caused by the inhalation of radioiodine 131I is below 5% of 20 mSv/year (occupational exposure limit). Med Pr 2013;64(5):625–630
Wprowadzenie: Ze względu na stosowanie promieniowania jonizującego medycyna nuklearna jest istotną i unikalną gałęzią metod diagnostycznych i leczniczych. Celem podjętych badań była ocena narażenia wewnętrznego pracowników zakładów medycyny nuklearnej na jod promieniotwórczy 131I i technet 99mTc oraz ocena dawek pochodzących z ekspozycji zewnętrznej. Materiał i metody: Pomiary zawartości radiojodu 131I i technetu 99mTc w tarczycy osób pracujących z tymi radionuklidami (ok. 100 osób) wykonano w 4 ośrodkach medycyny nuklearnej. Zastosowano przenośny zestaw detekcyjny mierzący radionuklidy in situ. Dawki pochodzące z ekspozycji zewnętrznej mierzono, wykorzystując środowiskowe dozymetry termoluminescencyjne (thermoluminescent dosimeters - TLD) o dużej czułości. Wyniki: Zawartość radiojodu 131I w tarczycy wynosiła średnio: 83 Bq (zakres aktywności: 70-250 Bq) w grupie personelu technicznego, 280 Bq (zakres: 70-4000 Bq) w grupie personelu medycznego i 275 Bq (zakres: 70-1000 Bq) w grupie personelu pomocniczego. Średnia zawartość technetu 99mTc w tarczycy wynosiła ok. 1500 Bq (zakres: 50-1800 Bq). Otrzymana moc dawek pochodzących z ekspozycji zewnętrznej mieściła się w zakresie 0,5-10 μGy/godz. Wnioski: Oszacowana średnia dawka skuteczna pochodząca z inhalacji radiojodu 131I stanowiła mniej niż 5% rocznego limitu dla narażenia zawodowego, które wynosi 20 mSv/rok. Med. Pr. 2013;64(5):625–630
Źródło:
Medycyna Pracy; 2013, 64, 5; 625-630
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Program zapewnienia kontroli jakości w medycynie nuklearnej. Testy podstawowe kontroli jakości planarnych kamer scyntylacyjnych oraz kamer SPECT i SPECT/CT
Quality Assurance in Nuclear Medicine. Routine tests of quality control of scintillation planar cameras and SPECT and SPECT/CT systems
Autorzy:
Matuszewski, Krzysztof
Szweda, Hubert
Cegła, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/986649.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
planarna kamera scyntylacyjna
SPECT
SPECT/CT
system kontroli jakości
medycyna nuklearna
poziom tła
okno energetyczne
jednorodność przestrzenna
położenie środka obrotu
rozdzielczość
liniowość
dopasowanie cięć
fantom Jaszczaka
planar scintilation camera
SPECT-CT
quality control system
nuclear medicine
background
energy window setting
field uniformity
center of rotation
COR
resolution
linearity
SPECT/CT alignment
Jaszczak phantom
Opis:
Regulacje prawne oraz zalecenia obligujące do tworzenia systemu kontroli jakości w medycynie nuklearnej mają na celu zapewnienie odpowiedniego poziomu jakości badań diagnostycznych. Podstawowe testy kontroli jakości są ważną częścią rutynowej pracy klinicznej. Celem niniejszej pracy jest przedstawienie procedur testów podstawowych kontroli jakości dla planarnych kamer scyntylacyjnych oraz systemów SPECT i SPECT/CT.
Regulations and recommendations that oblige to create a system of quality assurance in nuclear medicine, provide a sufficient level of quality diagnostic tests. The basic quality control tests are important part of routine clinical work. The aim of the work is to present quality control procedures for planar cameras and SPECT and SPECT/CT systems.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 4; 279-287
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Program zapewnienia kontroli jakości w medycynie nuklearnej. Testy podstawowe kontroli jakości skanerów PET i PET/CT
Quality Assurance in Nuclear Medicine. Routine tests of quality control of PET and PET/CT systems
Autorzy:
Matuszewski, Krzysztof
Szweda, Hubert
Cegła, Paulina
Radomiak, Dawid
Pawałowski, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/2146787.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
skaner PET
system kontroli jakości
medycyna nuklearna
stabilność detektora
normalizacja
jednorodność zrekonstruowanego obrazu
kalibracja koncentracji aktywności
jakość obrazu
fantom Jaszczaka
tomograficzna rozdzielczość przestrzenna w powietrzu
dopasowanie cięć
PET system
quality control system
nuclear medicine
PET detector stability
PET normalization
uniformity of the reconstructed image
radioactivity concentration calibration
image quality
Jaszczak phantom
tomographic spatial resolution in air
PET/CT alignment
Opis:
Jednym z warunków zapewnienia i utrzymania wysokiego poziomu jakości badań diagnostycznych w medycynie nuklearnej jest wykonywanie testów kontroli jakości zgodnie z zaleceniami i regulacjami prawnymi. Testy podstawowe kontroli jakości, będące jednym z elementów systemu kontroli jakości w zakładach medycyny nuklearnej, są nieodzowną częścią rutynowej pracy klinicznej. Niniejsza praca ma na celu przedstawienie procedur wykonywania testów podstawowych kontroli jakości dla skanerów PET i PET/CT.
One of the conditions for ensuring and maintaining a high level of quality diagnostic exams in nuclear medicine is to perform quality control tests in accordance with legal recommendations and regulations. Basic quality control tests, which are one of the elements of the quality control system in nuclear medicine departments, are a very important part of routine clinical work. This work aims to present the procedures for performing basic quality control tests for PET and PET/CT scanners.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 6; 459--465
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies