Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "nonlinear load" wg kryterium: Temat


Tytuł:
Influences of porosity and tangential edge constraint on thermo-torsional postbuckling of FGM toroidal shell segments surrounded by an elastic medium
Autorzy:
Nhu Trang, L. T.
Van Tung, H.
Powiązania:
https://bibliotekanauki.pl/articles/38697106.pdf
Data publikacji:
2023
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
nonlinear buckling
porous FGM
toroidal shell segment
tangential edge constraint
torsional load
Opis:
For the first time, simultaneous influences of porosities, tangential constraints of boundary edges, surrounding elastic media and elevated temperature on the buckling and postbuckling behaviors of a functionally graded toroidal shell segment are investigated in this paper. Porosities exist in the functionally graded material (FGM) according to even and uneven distributions. Properties of constituent materials are assumed to be temperature dependent and effective properties of the porous FGM are determined using a modified rule of mixture. Governing equations are based on the classical shell theory taking into account geometrical nonlinearity and interactive pressure from surrounding elastic medium. Multi-term analytical solutions are assumed to satisfy simply supported boundary conditions and the Galerkin method is adopted to derive nonlinear load – deflection relations and buckling loads. Parametric studies are carried out to analyze the effects of porosity, shell geometry, degree of tangential edge constraint, elevated temperature and elastic media on the buckling resistance and postbuckling strength of toroidal shell segments under a torsional load. The study reveals that tangential edge restraints have considerably beneficial and detrimental influences on the nonlinear stability of torsion-loaded FGM shells at room and elevated temperatures, respectively. The results also find out that the shear layer and the elastic layer of surrounding medium significantly enhances and alleviates the buckling resistance capacity and severity of the snap-through response of the torsion-loaded porous FGM toroidal shell segment, respectively.
Źródło:
Archives of Mechanics; 2023, 75, 4; 401-429
0373-2029
Pojawia się w:
Archives of Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear postbuckling behavior of auxetic-core toroidal shell segments with Graphene reinforced face sheets under axial loads
Autorzy:
Nam, V. H.
Duc, V. M.
Doan, C. V.
Thanh Xuan, N. T.
Phuong, N. T.
Powiązania:
https://bibliotekanauki.pl/articles/38693072.pdf
Data publikacji:
2022
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
axial compressive
tensile load
nonlinear buckling
graphene reinforced composite
auxetic-core
face sheet
toroidal shell segment
Opis:
The main aim of this paper is to provide an analytical approach for the nonlinear buckling behaviors of toroidal shell segments made by three layers included honeycomb auxetic-core and two Graphene reinforced face sheets under axial compressive or tensile loads. The auxetic core is designed in a honeycomb form and three distribution laws of Graphene are considered for two symmetric face sheets. The homogenization technique for honeycomb auxetic plates and shells is applied to establish the stiffness formulations of the core. By approximating the doubly curved coordinate to the simpler coordinate with the Stein and McElman assumption, the nonlinear basic equations are formulated using the nonlinear Donnell shell theory and the model of the two-parameter foundation. The Galerkin method can be performed three times for three states of buckling responses and the expressions of the load-deflection postbuckling curves can be determined. The numerical examinations present that the bifurcation buckling occurs with both axial tensile and compressive loads for convex and concave shells and the significantly beneficial effects of auxetic core and functionally graded Graphene reinforced face sheets on nonlinear buckling responses of shell segments.
Źródło:
Archives of Mechanics; 2022, 74, 2-3; 89-108
0373-2029
Pojawia się w:
Archives of Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal selection of inner-branches parameters of matching circuits under the minimum branch-current RMS values and zero active-power conditions
Autorzy:
Jaraczewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201906.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-terminal-network compensators
optimization
nonlinear load
Opis:
The article is a continuation of a study on the synthesis of matching multi-terminal networks, also known as compensators. The reactive four-terminal-network compensators for linear loads were introduced in previous publications, but it appeared they operate effectively with nonlinear loads too. The methods to create a compensator for a mono-harmonic source, which allows complete independence of the input from output waveforms, ensuring optimal operating conditions for the source, are presented herein. The work for the first time presents the optimal four-terminal-network compensator applied to a nonlinear load.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 777-783
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza oddziaływań w obwodzie systemu elektroenergetycznego z obciążeniem nieliniowym
Analysis of interactions in the circuit of the power system with nonlinear load
Autorzy:
Wciślik, Mirosław
Strząbała, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/267057.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
obciążenie nieliniowe
wyższe harmoniczne
kompensacja mocy biernej
analiza oddziaływań
nonlinear load
higher harmonics
reactive power compensation
interaction analysis
Opis:
W pracy analizowany jest obwód prądu przemiennego z przykładowym obciążeniem nieliniowym i filtrem biernym LC. Przyjęto obciążenie nieliniowe, którego napięcie na zaciskach zasilania jest proporcjonalne do funkcji signum prądu. Charakterystyka napięciowo - prądowa takiego obciążenia jest jednoznaczna (bez histerezy). Przeprowadzono analizę jakościową przebiegów napięć i prądów obwodu. Wykonano analizy przepływu mocy czynnej i biernej dla harmonicznej podstawowej i wyższych harmonicznych w obwodzie.
The paper deals with the AC circuit with an example of a non-linear load and an LC passive filter. The voltage on the nonlinear load terminals is proportional to the signum function of the current. The voltage - current characteristic of such load is unambiguous (without hysteresis). The quality analysis of the voltage and current waveforms of the circuit was carried out. The analysis of active and reactive power flow for fundamental and higher harmonics in the circuit were carried out.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 79-82
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Asymetria napięciowo - prądowa w torze zasilania pieca łukowego AC
Voltage-current asymmetry in the AC arc furnace supply line
Autorzy:
Jagieła, Kazimierz
Rak, Janusz
Gała, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1196732.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
piec łukowy AC
nieliniowe obciążenie
składowe symetryczne
współczynniki asymetrii
AC arc furnace
nonlinear load
symmetrical components
asymmetry coefficients
Opis:
AC arc furnaces are loads of high-power electric power with chaotic non-sinusoidal currents, especially in the first phase of steel melting. This type of work causes a negative impact on the supply network in the form of voltage fluctuations, asymmetry and distortion of the sinusoidal voltage waveform. The paper presents the analysis of asymmetry of voltages and currents in the power supply path of an AC arc furnace.The basic harmonics of voltage and current waveforms at individual points of the power line were calculated using the Fast Fourier Transform on the basis of computer-recorded measurement data. Next, the symmetrical components of the consistent and opposite order, the asymmetry coefficients and the mean values of phase impedances at the low and medium voltage level were determined for the melting and refining state.
Piece łukowe AC są odbiornikami energii elektrycznej dużej mocy o chaotycznym poborze prądów niesinusoidalnych, zwłaszcza w pierwszej fazie topienia stali. Taki charakter pracy powoduje negatywne oddziaływanie na sieć zasilającą w postaci wahań napięcia, asymetrii oraz odkształcenia przebiegu napięcia od sinusoidy. W artykule przedstawiono analizę asymetrii napięć i prądów w torze zasilania pieca łukowego AC. Na podstawie zarejestrowanych komputerowo danych pomiarowych obliczono za pomocą szybkiej transformaty Fouriera podstawowe harmoniczne przebiegów napięć i prądów w poszczególnych punktach toru zasilania. Następnie wyznaczono składowe symetryczne kolejności zgodnej i przeciwnej, współczynniki asymetrii oraz średnie wartości impedancji fazowych na poziomie niskiego i średniego napięcia dla stanu roztapiania i rafinacji.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 2, 122; 123-129
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear component of free vibration frequency of a partially tensioned system with consideration of rotational stiffness of support
Autorzy:
Uzny, Sebastian
Osadnik, Michał
Powiązania:
https://bibliotekanauki.pl/articles/122407.pdf
Data publikacji:
2019
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
slender nonlinear systems
amplitude of vibrations
Euler’s load
układ smukły
amplituda wibracji
obciążenie Eulera
Opis:
The nonlinear vibrations of a slender system subjected to Euler’s load which is partially tensioned is discussed in this paper. The longitudinal displacement and rotation on both of the system ends are limited by the discrete elements in the form of translational and rotational springs. The results of numerical simulations concern the first vibration frequency (linear and non-linear components) in relation to the location and magnitude of external load application and different rotational spring stiffness. This nonlinear system is based on the screw drive used in the newly designed vertical platform lifts.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2019, 18, 3; 89-96
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear vibrations of the partially tensioned system taking into account the asymmetry of the stiffness of supports
Autorzy:
Uzny, Sebastian
Osadnik, Michał
Powiązania:
https://bibliotekanauki.pl/articles/128293.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
slender nonlinear systems
free vibrations
Euler’s load
nieliniowe układy smukłe
drgania swobodne
obciążenie Eulera
Opis:
The nonlinear vibrations of the partially tensioned slender column are presented in this paper. The considered system is subjected to Euler’s load, which direction of action is consistent with the non-deformed axis of the column. The magnitude of the external load is variable and its application point is located at different heights between the upper and lower supports. In addition, the longitudinal displacement and rotation of both of the system ends are limited by the discrete elements in the form of translational and rotational springs. This nonlinear system is based on the screw drive used in the vertical lift platform for disabled people or cargo lift equipped with an engine room located in the lower part of the frame. The boundary problem of free vibrations of the mentioned system has been formulated on the basis of Bernoulli - Euler theory and due to nonlinear expressions the solution of the problem was conducted with small parameter method. The results of numerical simulations are concern on linear and nonlinear component of vibrations in relation to the location of external load application and influence of asymmetric value of supports stiffness on the free vibration frequency.
Źródło:
Vibrations in Physical Systems; 2019, 30, 2; 1-8
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena asymetrii napięć i prądów w instalacji zasilania pieca łukowego AC
Evaluation of voltage and current asymmetry in the AC arc furnace power supply installation
Autorzy:
Rak, Janusz
Gała, Marek
Jagieła, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/304936.pdf
Data publikacji:
2019
Wydawca:
Wydawnictwo Druk-Art
Tematy:
piec łukowy AC
nieliniowe obciążenie
składowe symetryczne
współczynnik asymetrii
AC arc furnace
nonlinear load
symmetrical components
asymmetry coefficient
Opis:
Elektryczny piec łukowy AC, ze względu na dynamiczny charakter pracy łuku elektrycznego, negatywnie oddziałuje na sieć zasilającą w postaci generowania wyższych harmonicznych, wahań napięcia oraz asymetrii. W artykule przedstawiono analizę asymetrii napięć i prądów w instalacji zasilania pieca łukowego AC. Na podstawie zarejestrowanych komputerowo danych pomiarowych obliczono za pomocą szybkiej transformaty Fouriera podstawowe harmoniczne przebiegów napięć i prądów w poszczególnych punktach toru zasilania. Następnie wyznaczono współczynniki asymetrii napięć i prądów oraz średnie wartości impedancji fazowych na poziomie niskiego i średniego napięcia dla stanów roztapiania i rafinacji.
The electric AC arc furnace, due to the dynamic nature of the electric arc operation, has a negative impact on the supply network in the form of generating higher harmonics, voltage fluctuations and asymmetry. The paper presents the analysis of asymmetry of voltages and currents in the power supply installation of an AC arc furnace. The basic harmonics of voltage and current waveforms at individual points of the power line were calculated using the Fast Fourier Transform on the basis of computer-recorded measurement data. Next, the voltage and current asymmetry coefficients as well as mean values of phase impedances at the low and medium voltage levels were determined for the melting and refining states.
Źródło:
Napędy i Sterowanie; 2019, 21, 10; 92-100
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Assessment of Steel Moment Connections Retrofitted With Various Reduced Section Patterns
Autorzy:
Sivandi-Pour, Abbas
Powiązania:
https://bibliotekanauki.pl/articles/396627.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
steel connector
performance assessment
load-bearing systems
reduced beam section
energy damping
cyclic behavior
nonlinear analysis
złącze stalowe
wzmocnienia
system nośny
analiza nieliniowa
Opis:
It is of high importance in seismic retrofitting of lateral load-bearing systems to increase the connections performance. The crucial point in the steel frame retrofitting process is to create plastic hinges in these types of frames. The formation of plastic hinges in beams and near columns generates large strains on column flanges as well as welding metal and heated surroundings, which can lead to brittle failure. The connection should be designed in such a way as to allow plastic hinge formation at certain points of the beam. One such method suggested for retrofit connections is to reduce the beam section locally away from the connection zone. There are various patterns available to locally reduce the beam section, such as circular, elliptical, and symmetric/asymmetric. In recent years, different proposals have been presented to design these connections which vary from older instructions. For this study, radiused cuts in the flange and slotted holes in the web of connection beams were selected for retrofitting analysis. Cyclic behavior, energy damping levels, and ductility of these connections were studied and compared before and after the retrofit by using nonlinear dynamic analysis. The results showed that the symmetrical circular hole pattern in the beam flanges demonstrated reliable performance.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 4; 1-17
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Buckling deformation of thin layer coverings of small curvatures used in aircraft construction
Autorzy:
Kopecki, Tomasz
Lis, Tomasz
Mazurek, Przemysław
Bakunowicz, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/103189.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
buckling
isogrid
loss of stability
aircraft load-bearing structures
finite elements method
nonlinear numerical analysis
wyboczenie
utrata stabilności
konstrukcje nośne statków powietrznych
metoda elementów skończonych
nieliniowa analiza numeryczna
Opis:
This paper presents the results of experimental and numerical analysis in terms of the finite element method of plating components of aircraft load bearing structures. The subject matter of the study was composite panels with stiffeners in the form of a regular grid of oriented longitudinal elements in accordance with the directions of the principal stresses in the covering. The analysis was conducted in the buckling states of structural deformation which showed that structures with stiffeners exhibit much more favorable behavior in buckling deformation states than in laminar structures. This translates into stress distributions and their gradients, which are milder in forms of stiffened structures.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 1; 293-302
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współpraca transformatora trójfazowego z obciążeniem nieliniowym
Cooperation of a three-phase transformer with non-linear load
Autorzy:
Daniluk, M.
Drabek, T.
Lerch, T.
Powiązania:
https://bibliotekanauki.pl/articles/93070.pdf
Data publikacji:
2018
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
transformator suchy
obciążenie nieliniowe
współczynnik K
obciążalność
dry transformer
nonlinear load
K-factor
load
Opis:
W artykule przedstawiono podstawy teoretyczne i wyprowadzenie wyrażenia pochodzącego z normy amerykańskiej, stosowanego do określenia termicznie dopuszczalnej obciążalności prądowej trójfazowych transformatorów suchych, w sytuacji obciążenia ich odbiorami nieliniowymi. Przedstawiono wyniki weryfikacji pomiarowej tego wyrażenia, przy różnych kształtach prądów obciążających badane transformatory suche. Wyniki badań potwierdziły poprawność wyrażenia dla transformatorów współcześnie produkowanych.
The paper presents the theoretical basics and the derivation of the American standard expression used to determine the thermally permissible current of three-phase dry transformers with nonlinear loads. The results of the measurement verification of this expression are presented, with different shapes of loading currents of the dry transformers under test. The results of the tests confirmed the correctness of the expression for contemporary transformers only.
Źródło:
Science, Technology and Innovation; 2018, 3, 2; 13-20
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and numerical analysis of compression thin-walled composite plates weakened by cut-outs
Doświadczalno-numeryczna analiza ściskanej cienkościennej płyty kompozytowej osłabionej otworem
Autorzy:
Falkowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/230307.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
konstrukcja cienkościenna
obciążenie krytyczne
analiza nieliniowa
kompozyt
badanie eksperymentalne
MES
metoda elementów skończonych
analiza numeryczna
płyta z wycięciem
thin-walled structure
buckling load
nonlinear analysis
composite
experimental investigations
FEM
finite element method
numerical analysis
plate with cut-out
Opis:
Buckling and postbuckling response of thin-walled composite plates investigated experimentally and determinated analytically and numerically is compared. Real dimension specimens of composite plates weakened by cut-out subjected to uniform compression in laboratory buckling tests have been modelled in the finite element method and examined analytically based on P-w2 and P-w3 methods. All results were obtained during the experimental investigations and the numerical FEM analysis of a thin-walled composite plate made of a carbon-epoxy laminate with a symmetrical eight-layer arrangement of [90/-45/45/0]s. The instrument used for this purpose was a numerical ABAQUS® program.
W pracy zajmowano się oryginalną koncepcją płytowego elementu cienkościennego z centralnym wycięciem, do zastosowania jako element sprężysty. Badania obejmowały liniową i nieliniową analizę numeryczną konstrukcji z wykorzystaniem metody elementów skończonych oraz eksperymentalną weryfikację obliczeń MES. Przedmiot badań stanowiła cienkościenna płyta z centralnym prostokątnym wycięciem, wykonana z kompozytu węglowo-epoksydowego. Struktura laminatu złożona była z 8 warstw o jednakowej grubości wynoszącej 0.131 [mm] w symetrycznym układzie warstw względem płaszczyzny środkowej pakietu. Badania prowadzono na płycie kompozytowej o konfiguracji warstw kompozytu [90/-45/45/0]s. Zakres pracy obejmował badania eksperymentalne na rzeczywistej konstrukcji oraz wykonanie symulacji numerycznej z wykorzystaniem metody elementów skończonych. Analizowano stan krytyczny ściskanej osiowo cienkościennej płyty kompozytowej z centralnym prostokątnym wycięciem, podpartej przegubowo na obydwu końcach oraz rozwiązanie zagadnienia nieliniowej stateczności, w którym obliczenia prowadzono na modelach z zainicjowaną imperfekcją geometryczną odpowiadającą wyższej, giętno-skrętnej postaci wyboczenia konstrukcji.
Źródło:
Archives of Civil Engineering; 2017, 63, 4; 161-172
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu indukcyjności zasilania na pracę prostownika mostkowego
Analysis of the Influence of a Power Inductance on the Operation of a Bridge Rectifier
Autorzy:
Wciślik, M.
Strząbała, P.
Powiązania:
https://bibliotekanauki.pl/articles/160185.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
odbiornik nieliniowy
prostownik mostkowy
praca ciągła
modelowanie
nonlinear load
bridge rectifier
continuous operation
modeling
Opis:
Układ prostownika dwupołówkowego mostkowego jest jednym z najczęściej stosowanych odbiorników nieliniowych. Głównym obszarem zastosowań tego układu są jednofazowe zasilacze sieciowe, które stanowią wyposażenie większości urządzeń elektronicznych. Pobór energii tego typu urządzeń nie jest duży. Jednak znaczna ich ilość jednocześnie pracująca w systemie elektroenergetycznym sprawia, że całkowity efekt negatywnych zjawisk wprowadzanych do systemu zasilania jest znaczący. W celu zbadania zjawisk w systemie, propagacji wyższych harmonicznych oraz mocy biernej, opracowano model umożliwiający symulację obwodu z prostownikiem dwu-połówkowym mostkowym, zasilanym przez dodatkową indukcyjność. W pierwszym etapie obwód był modelowany w programie PSpice. Wyniki porównano z przebiegami w obwodzie rzeczywistym. Zaproponowano nieliniowy model prostownika mostkowego. W pracy przedstawiono stosowane modele obwodów z prostownikiem mostkowym oraz sposoby ich analizy. Opracowano model matematyczny analizowanego obwodu oraz przedstawiono metodykę formowania równań opisujących obwód z wykorzystaniem zmiennych bezwymiarowych. Na podstawie modelu matematycznego utworzono schemat operacyjny obwodu w programie Simulink. Przeprowadzono analizę pracy ciągłej prostownika oraz wykonano bilanse mocy czynnej oraz biernej.
A full-wave bridge rectifier is one of the most often used non-linear load. A main area of its using are single-phase power suppliers which are a part of the most of electronic devices. The power consumption of these devices is not large. However a large number of them that work simultaneously in the power system may cause that the total effect of voltage disturbances in the power system is significant. For the purpose of investigation of the propagations of higher harmonics and the reactive power phenomena in the system, the model of the circuit with the full-wave rectifier bridge with an additional inductance connected in-series supplied from AC voltage source was worked out. In the first step, the circuit was modeled in PSpice system. The result were compared with the waveforms of the real circuit. The non-linear model of the bridge rectifier was proposed. The models of circuit and methods of their analysis were presented. The mathematical model of the analysed circuit was worked out. Methodology of circuit equations forming with the use of dimensionless variables was shown. On the basis of the mathematical model the operational diagram in Simulink of the circuit was created. The operation analysis of the continuous work of the rectifier was carried out. The balances of active and reactive power were performed.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 272; 49-62
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-buckling deformation states of semi-monocoque cylindrical structures with large cut-outs under operating load conditions. Numerical analysis and experimental tests
Stany zakrytycznych deformacji półskorupowych konstrukcji walcowych z dużymi wykrojami w warunkach obciążeń eksploatacyjnych. Analiza numeryczna i badania eksperymentalne
Autorzy:
Kopecki, T.
Mazurek, P.
Lis, T.
Chodorowska, D.
Powiązania:
https://bibliotekanauki.pl/articles/1365848.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
operating loads
loss of stability
thin-walled structures
aircraft load-bearing structures
torsional deflection
finite element method
nonlinear numerical analyses
operating stability
obciążenia eksploatacyjne
utrata stateczności
ustroje cienkościenne
lotnicze struktury nośne
skręcanie
metoda elementów skończonych
nieliniowe analizy numeryczne
trwałość eksploatacyjna
Opis:
The paper is a presentation of experimental model studies on thin-walled cylindrical structures containing large cut-outs subject to torsional deflection. The effect of rigidity of the frame reinforcing a cut-out on form and magnitude of post-buckling deformations occurring in operation conditions is analysed. A methodology based on numerical tools is proposed for determining alternative solutions in the design of structure skeleton leading to improvement of operation stability.
W pracy zaprezentowano wyniki modelowych badań eksperymentalnych cienkościennych, skręcanych struktur walcowych zawierających duże wykroje. Przeanalizowano wpływ sztywności ramy wzmacniającej wykrój na postać i wielkość deformacji zakrytycznych, występujących w warunkach eksploatacji. Zaproponowano metodykę określania alternatywnych rozwiązań konstrukcyjnych szkieletu struktury, zapewniające poprawę trwałości eksploatacyjnej, w oparciu o narzędzia numeryczne.
Źródło:
Eksploatacja i Niezawodność; 2016, 18, 1; 16-24
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of higher mode effects and lateral load patterns in pushover analysis of steel frames with steel shear wall
Autorzy:
Ghanoonibagha, M.
Gol, M. R. A.
Ranjbar, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/102543.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
load patterns
steel shear wall
static nonlinear
dynamic nonlinear
Opis:
When an earthquake occurs, the structure will enter into a nonlinear stage; therefore, new approaches based on nonlinear analysis are needed to flourish with the purpose of more realistic investigations on seismic behavior and destruction mechanism of structures. According to the modern philosophy, “Performance-based Earthquake Engineering” is formed in which simple nonlinear static analyses are mostly used in order to determine the structure’s behavior in nonlinear stage. This method assumes that the structure response is only controlled by the main mode and the shape of this mode will remain the same, while it enters the nonlinear stage. Both of these assumptions are approximations, especially in high buildings, which have a long period. It seems that constant load pattern used in these methods cannot consider all of the effects properly. In this paper, an attempt was made to study the accuracy of these methods in comparison to nonlinear dynamic analysis, by considering various load patterns existing in FEMA, also load patterns proportional to higher modes in nonlinear static method, and employing an approximative method of MPA modal analysis, study the accuracy of these methods in comparison to nonlinear dynamic analysis. For this purpose, three steel frames of 4, 8, and 12-stories with steel shear wall have been studied.
Źródło:
Advances in Science and Technology. Research Journal; 2016, 10, 29; 13-27
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies