Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "non-symmetry" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Existence and asymptotic behavior of solutions for hénon type equations
Autorzy:
Long, W.
Yang, J.
Powiązania:
https://bibliotekanauki.pl/articles/255754.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Henon equation
cylindrical symmetry
non-cylindrical symmetry
asymptotic behavior
Opis:
This paper is concerned with ground state solutions for the Hénon type equation [formula] in Ω, where Ω = Bk(0, 1) × Bn-k(0, 1) ⊂ Rn and x = (y, z) ∈ Rk × Rn-k. We study the existence of cylindrically symmetric and non-cylindrically symmetric ground state solutions for the problem. We also investigate asymptotic behavior of the ground state solution when p tends to the critical exponent [formula].
Źródło:
Opuscula Mathematica; 2011, 31, 3; 411-424
1232-9274
2300-6919
Pojawia się w:
Opuscula Mathematica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the harmonic composition of current in the zero-working wire at the input of the load node with the prevailing non-linear power consumers
Autorzy:
Yudaev, Igor V.
Rud, Evgeny V.
Yundin, Mikhail A.
Ponomarenko, Tamara Z.
Isupowa, Aleksandra M.
Powiązania:
https://bibliotekanauki.pl/articles/1841306.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
harmonic currents
non-linear power receiver
non-symmetry
three-phase fourwire network
zero working wire of the network
prądy harmoniczne
nieliniowy odbiornik mocy
niesymetria
sieć trójfazowa czteroprzewodowa
zerowy przewód roboczy sieci
Opis:
Due to the extensive use of nonlinear power consumers, there is currently an urgent problem of high harmonic content in power supply networks. The paper provides experimental investigations and a study of the nature of the change in the main harmonic components of the current in the neutral working wire of a three-phase four-wire network with a voltage of 0.38 kV. The purpose of this study is to compare the load readings on the amplitude-phase-frequency characteristics of the current in the neutral working wire of the 0.38 kV network with the linear and non-linear load. To study the effect of load changes on the amplitude-phase-frequency characteristics of currents in the linear and zero working wires at the input of the load node, measurements were carried out by certified electrical measuring instruments. The analysis of the results obtained for the load node whose power was formed mainly by a lighting system with fluorescent and LED lamps and a system of office electrical receivers (computers, copiers, printers, scanners, etc.) was performed. It can be concluded that a current comparable to the currents of the linear wires of the network flows from the load node with the predominant nonlinear power receivers through the zero-working wire. At the same time, in the zero-working wire of the network, the third harmonic currents prevail over the main frequency currents.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 463-473
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies