Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "noise attenuation" wg kryterium: Temat


Tytuł:
Attenuation of Humming-Type Noise and Vibration in Vehicle HVAC System Using a Tuneable Dynamic Vibration Absorber
Autorzy:
Aziz, Muhammad Safwan Abdul
Mazlan, Ahmad Zhafran Ahmad
Satar, Mohd Hafiz Abdul
Paiman, Muhammad Abdul Rahman
Ghapar, Mohd Zukhairi Abd
Powiązania:
https://bibliotekanauki.pl/articles/31339994.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
HVAC
humming noise
vibration attenuation
AC pipe
TDVA
Opis:
Heating, ventilation, air conditioning (HVAC) is one of crucial system in a vehicle. Unfortunately, its performance can be affected by the vibration of HVAC components, which subsequently produced unwanted noises. This paper presents an innovative design solution which called as tuneable dynamic vibration absorber (TDVA) to reduce the humming-type noise and vibration in the HVAC system. A detail investigation is carried by developing a lab-scale HVAC model that has the capability to imitate the real HVAC operation in a vehicle. An alternated air-condition (AC) with a fixed blower speed is implied in the study. The analysis of humming-type noise and vibration induced from the HVAC components are performed, and the TDVA is designed and tuned according to the natural frequency of the AC pipe before the attachment. The humming-type noise and vibration characteristics of the HVAC components are compared before and after the implementation of the TDVA. The findings shown that the HVAC model data compares well with the vehicle data, whereby the implementation of TDVA is found to reduce the vibration of the AC pipe by 79% and 61% in both idle and operating conditions and this subsequently improved the humming-type noise of the HVAC system. It also been observed that the TDVA has an effective frequency range around 75–255 Hz and 100–500 Hz for the HVAC model and vehicle systems, respectively.
Źródło:
Archives of Acoustics; 2022, 47, 3; 331-342
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Protectors: Topicality and Research Needs
Autorzy:
Canetto, P.
Powiązania:
https://bibliotekanauki.pl/articles/89860.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
occupational noise
hearing protectors
human behaviour
attenuation
real world
derating
subject-fit
comfort
research
Opis:
Occupational noise specialists do not generally recommend hearing protection devices (HPDs) as a preferred solution to noise risk prevention. Nevertheless, these devices are widely used and are in fact often necessary. Selection of an HPD should take into account comfort and the capacity for perceiving external signals, when they are worn. Current European regulations require that HPD attenuation be considered, when comparing noise exposure to limit values. However, HPD attenuation is effectively unknown under real-world conditions. Some methods are designed to give approximate attenuation values and these provide results within a wide statistical range. Field measurement methods and current standards have been developed to deal with this situation. The specific characteristic of impulse noise requires establishment of dedicated criteria and tools for HPD selection and testing. This paper introduces a number of avenues for research, which could be of assistance in improving HPD selection, qualification and design.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 2; 141-153
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected aspects of modeling mufflers for exhaust systems of vehicles
Autorzy:
Gągorowski, A.
Melon, A.
Powiązania:
https://bibliotekanauki.pl/articles/245148.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
vehicles
noise reduction
exhaust system
mufflers
efficiency of attenuation
Opis:
The world used several solutions exhaust systems of motor vehicles. Today, in addition to the core function of which is to discharge exhaust gases from a combustion engine and noise reduction, these systems must comply with the functions associated with aftertreatment and impact on the characteristics of the engine. Requirements increase for noise suppression, at the tendency to increase engine efficiency and reduce fuel consumption. On the other hand, it seeks to reduce production costs. All this forces the search for new solutions and improve existing ones. In the process of the combustion gases discharge it is also important to eliminate frequency bands especially harmful to people and the environment (including other living organisms). Our goal is to develop a new design muffler of exhaust system that will meet these expectations of producers and users of vehicles. For this purpose, mathematical analysis of a classical systems with circular holes in the perforated pipes and proposed by the authors of the longitudinal gaps systems was performed. The paper presents some aspects of mufflers modeling for reducing acoustic noise emitted from the vehicle. Basic criterion for assessing was therefore the damping effect. Built theoretical models have allowed a rough estimate of acoustic performance at specific frequency bands by determining the transfer impedances. Because the noise reduction in automobiles is a complex, for the construction of such systems one of the important elements is to eliminate these frequency bands of acoustic waves in the process of the exhaust gases discharge which are the most dangerous to humans. The comparative analysis of these systems has allowed to determine the direction of further structural changes.
Źródło:
Journal of KONES; 2013, 20, 2; 97-103
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of the effectiveness of the seismic noise attenuation by means of Karhunen-Loeve (K-L) transform
Analiza skuteczności tłumienia zakłóceń sejsmicznych za pomocą transformacji Karhunena-Loevego (K-L)
Autorzy:
Kasina, Z.
Powiązania:
https://bibliotekanauki.pl/articles/183773.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
geofizyka
metoda sejsmiczna
przetwarzanie
transformacja K-L
tłumienie szumu
geophysics
seismic methods
processing
K-L transform
noise attenuation
Opis:
In the paper the analysis of the effectiveness of multiples and random noise attenuation using Karhunen-Loeve (K-L) transform is presented. The K-L transform is realized with application the process Eigenimage Filter in seismic data processing system ProMAX. The basic part of the paper is directed to the analysis of multiples attenuation by means of the K-L transform applied to field data. In the analysis the common shot point gathers (seismic records) were used as well as the traces of the CDP gathers. In the case of CDP gathers the main attention was paid on the multiple attenuation in the averaged CDP gathers (supergathers) prepared for the interactive velocity analysis. The influence of the K-L filter parameters was defined on the effectiveness of multiples removing from the velocity analysis wave images. Finally the effectiveness of the K-L filter was estimated in improving the coherent to random signals ratio on the seismic records.
W prezentowanej pracy przedstawiono analizę efektywności tłumienia fal wielokrotnych i szumu przypadkowego za pomocą filtracji Karhunena-Loevego (K-L), realizowanej z wykorzystaniem procedury Eigenimage Filter systemu przetwarzania ProMAX. Zasadniczą część pracy poświęcono analizie efektywności tłumienia fal wielokrotnych za pomocą filtracji K-L, zastosowanej do danych polowych. W analizie wykorzystano zarówno trasy kolekcji wspólnego punktu wzbudzenia (rekordy sejsmiczne), jak i trasy kolekcji wspólnego punktu odbicia (kolekcje CDP). W przypadku kolekcji CDP uwagę skoncentrowano na osłabianiu fal wielokrotnych w uśrednionych kolekcjach CDP (superkolekcje CDP), przygotowanych do interaktywnej analizy prędkości. Określono wpływ parametrów filtracji K-L na skuteczność usuwania fal wielokrotnych z obrazu falowego analiz prędkości. W końcowym etapie pracy oceniono skuteczność filtracji K-L w poprawianiu stosunku sygnałów koherentnych do zakłóceń przypadkowych na rekordach sejsmicznych.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2010, 36, 2; 203-221
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensor Hop-based Energy Efficient Networking Approach for Routing in Underwater Acoustic Communication
Autorzy:
Kohli, S.
Bhattacharya, P. P.
Powiązania:
https://bibliotekanauki.pl/articles/309397.pdf
Data publikacji:
2017
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
attenuation
clustering
multi-hop routing
signal-to-noise ratio
transmission loss
Opis:
Underwater Wireless Sensor Networks are deployed to explore the world under the water, measure different parameters and communicate the data to the surface, in the widespread applications. The main operating technology of these networks is the acoustic communication. The communication among the sensors and finally to the surface station requires a routing protocol. The sensors being battery limited and unfeasible to be replaced under the water requires an energy efficient routing protocol. Clustering imparted in routing is an energy saving technique in sensor networks. The routing may involve single or multi hop communication in the sensor networks. The paper gives a comparative study of the benchmark protocol multi-hop LEACH with the proposed Sensor Hop-based Energy Efficient Networking Approach (SHEENA) for the shallow as well as deep water in three dimensional Underwater Wireless Sensor Networks. The network energy model for the Underwater Wireless Sensor Networks is based among the different acoustic channel characteristics. The proposed approach is found to give better response.
Źródło:
Journal of Telecommunications and Information Technology; 2017, 1; 44-49
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Effective Noise Exposure of Workers Wearing Ear-Muffs
Autorzy:
Kotarbińska, E.
Kozłowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/90912.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
noise exposure
hearing protectors
earmuffs
real-world attenuation
Opis:
This paper presents the methodology and the results of binaural measurements of exposure to noise for 91 industry workers wearing ear-muffs. The results revealed that 18.7% of the workers were exposed to noise of equivalent A-weighted sound pressure levels of over 80 dB(A) and 7.7% to levels of over 85 dB(A). The measured levels were compared with those calculated with the octave-band method according to Standard No. EN 458:2004. The differences ranged from – 3 dB(A) to 26.5 dB(A); their statistical distribution did not indicate any data which could suggest derating laboratory measurements. The main causes of exposure to noise higher by over 3 dB(A) than that theoretically predicted were the bad technical condition of ear-muffs (32.2% of the cases) and an incorrect way of wearing them (15.2%).
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 2; 193-200
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Attenuation of earmuffs used simultaneously with safety spectacles in exposure to impulse noise
Badania eksperymentalne tłumienia nauszników przeciwhałasowych stosowanych łącznie z okularami ochronnymi w warunkach występowania hałasu impulsowego
Autorzy:
Kozłowski, E.
Młyński, R.
Powiązania:
https://bibliotekanauki.pl/articles/210323.pdf
Data publikacji:
2018
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
acoustics
noise protection
impulse noise
hearing protectors
earmuffs
noise attenuation
akustyka
ochrona przed hałasem
hałas impulsowy
ochronniki słuchu
nauszniki przeciwhałasowe
tłumienie hałasu
Opis:
Impulse noise is particularly hazardous to the hearing of exposed individuals. In many real-life scenarios, the only protective measure used to reduce the level of impulse noise is hearing protectors. These scenarios include firing ranges. Aside from hearing protectors, shooters use personal safety spectacles. The purpose of this paper was to determine the effect of the simultaneous use of earmuffs and safety spectacles on the sound attenuation of earmuffs during exposure to impact noise. The research was completed with the MIRE method and included the determination of sound attenuation changes in five different models of earmuffs, used simultaneously with three different models of safety spectacles and prescription glasses. The impulse noise source used was a starting pistol, which generated C-weighted peak sound pressure level at a mean of 136.7 dB. The tests demonstrated that the simultaneous use of safety spectacles and earmuffs reduces the impulse noise attenuation of the earmuffs by up to 9 dB. Such sound attenuation changes occurred during simultaneous use of earmuffs with safety spectacles, which feature temples with a rectangular cross-section. The tests also demonstrated that the effect of prescription glasses on sound attenuation was unusually high; prescription glasses reduced the impulse sound attenuation of earmuffs by as much as 18 dB.
Hałas impulsowy jest szczególnie niebezpieczny dla słuchu osób na niego eksponowanych. W wielu sytuacjach jedynym środkiem ograniczania hałasu impulsowego są ochronniki słuchu. Taka sytuacja występuje na przykład na strzelnicach. Poza ochronnikami słuchu strzelcy również często korzystają z indywidualnych ochron oczu. Celem przedstawionych badań było określenie jak jednoczesne stosowanie nauszników przeciwhałasowych i okularów wpływa na zmianę tłumienia nauszników w sytuacji występowania hałasu impulsowego. Badania zostały przeprowadzone z wykorzystaniem metody MIRE i obejmowały wyznaczenie zmian tłumienia dźwięku pięciu modeli nauszników przeciwhałasowych stosowanych jednocześnie z trzema modelami okularów ochronnych oraz okularami korekcyjnymi. Źródłem hałasu impulsowego był pistolet startowy, który generował dźwięk o szczytowym poziomie dźwięku C wynoszącym średnio 136,7 dB. Przeprowadzone badania wykazały, że jednoczesne używanie okularów ochronnych i nauszników obniża tłumienie hałasu impulsowego wnoszone przez nauszniki maksymalnie do 9 dB. Takie zmiany występowały podczas jednoczesnego stosowania nauszników i okularów charakteryzujących się zausznikami o prostokątnym przekroju. Badania także wykazały wyjątkowo duży wpływ okularów korekcyjnych na tłumienie nauszników, które spowodowały pogorszenie tłumienia hałasu impulsowego wnoszonego przez nauszniki nawet o 18 dB.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2018, 67, 1; 43-52
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania prawidłowego umieszczania wkładek przeciwhałasowych w przewodzie słuchowym z użyciem przenośnego urządzenia
Tests for the correct insertion of earplugs in the ear canal performed with the use of a portable device
Autorzy:
Kozłowski, Emil
Młyński, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/2087519.pdf
Data publikacji:
2021-11-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
hałas
ochronniki słuchu
wkładki przeciwhałasowe
tłumienie dźwięku
inżynieria środowiska
ochrona słuchu
noise
hearing protectors
earplugs
sound attenuation
environmental engineering
hearing conservation
Opis:
WstępCelem badań było przeprowadzenie oceny poprawności umieszczania wkładek przeciwhałasowych w przewodzie słuchowym przez osoby dysponujące różną wiedzą w tym zakresie. Stosowanie ochronników słuchu prowadzi do obniżenia ryzyka uszkodzenia słuchu, co wpisuje się w zagadnienia inżynierii środowiska.Materiał i metodyPrzeprowadzono pomiary tłumienia dźwięku wkładek przeciwhałasowych z udziałem 21 osób bez doświadczenia w ich stosowaniu. Pomiary powtórzono po zapoznaniu się badanych z instrukcją użytkowania wkładek, a następnie po przeszkoleniu w ich poprawnym umieszczaniu w przewodzie słuchowym. Badania przeprowadzono za pomocą nowo opracowanego przenośnego urządzenia służącego do szybkiego pomiaru tłumienia dźwięku.WynikiZapoznanie się badanych z instrukcją użytkownika spowodowało, że wartość tłumienia dźwięku była większa o 6,7 dB i 3,3 dB, odpowiednio, dla częstotliwości 250 Hz i 4000 Hz w stosunku do pomiaru, podczas którego wkładki były umieszczane w przewodzie słuchowym bez jakichkolwiek wskazówek. Jeszcze większy wzrost tłumienia (odpowiednio, 9,2 dB i 5,4 dB) zaobserwowano, gdy badani przeszli szkolenie z poprawnego umieszczania wkładek. W większości przypadków zmiany tłumienia dźwięku w wyniku udzielania badanym wskazówek były istotne statystycznie.WnioskiOsoby niemające żadnego doświadczenia w stosowaniu wkładek przeciwhałasowych mają znaczny problem z ich poprawnym umieszczaniem. Zapoznanie się z instrukcją użytkownika także tego nie gwarantuje. Dopiero szkolenie polegające na dokładnym pokazaniu, jak poprawnie umieszcza się wkładki, powoduje, że w większości przypadków badani potrafią zrobić. Med. Pr. 2021;72(5):521–528
BackgroundThe aim of the study was to assess the correct insertion of earplugs in the ear canal by people with different knowledge regarding this matter. The use of hearing protectors leads to a reduction in the risk of hearing loss, which is part of environmental engineering.Material and MethodsMeasurements of sound attenuation by earplugs were carried out with the participation of 21 people with no experience in the use of earplugs. The measurements were repeated until the subjects had read the instructions for the use of earplugs, and then after the subjects had been trained in the correct insertion of earplugs in the ear canal. The tests were carried out using a newly developed portable device for quick measurements of sound attenuation.ResultsFamiliarizing the subjects with the instructions for use resulted in a sound attenuation value being 6.7 and 3.3 dB higher, at 250 and 4000 Hz, respectively, compared to the measurement when the subjects inserted earplugs in the ear canal without any guidance. An even greater increase in attenuation was observed when the subjects were trained to insert earplugs, at 9.2 dB (250 Hz) and 5.4 dB (4000 Hz), respectively. In most cases, the changes in attenuation as a result of providing guidance were statistically significant.ConclusionsPersons who have no experience in using earplugs have significant problems with their correct insertion. Reading the instructions for use does not guarantee that earplugs will be inserted correctly. Only the training showing how to insert the earplugs correctly results in people being able to do it correctly in most cases. Med Pr. 2021;72(5):521–8
Źródło:
Medycyna Pracy; 2021, 72, 5; 521-528
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tłumienie hałasu ultradźwiękowego w zakresie częstotliwości 10–16 kHz przez wkładki przeciwhałasowe
Attenuation of ultrasonic noise in the 10–16 kHz frequency range by earplugs
Autorzy:
Kozłowski, Emil
Młyński, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/2162484.pdf
Data publikacji:
2018-08-20
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ochronniki słuchu
wkładki przeciwhałasowe
hałas ultradźwiękowy
tłumienie dźwięku
ochrona słuchu
REAT
hearing protectors
earplugs
ultrasonic noise
sound attenuation
hearing conservation
Opis:
Wstęp Celem badań było określenie tłumienia hałasu ultradźwiękowego o częstotliwościach środkowych z zakresu 10–16 kHz przez wkładki przeciwhałasowe. Materiał i metody Wykonano pomiary tłumienia wkładek przeciwhałasowych w pasmach 1/3-oktawowych dla częstotliwości środkowych z zakresu 10–16 kHz z użyciem metody REAT (real-ear attenuation at threshold) polegającej na pomiarach progów słyszenia z udziałem osób. Badania przeprowadzono dla 29 modeli powszechnie stosowanych w przemyśle wkładek przeciwhałasowych różnych producentów, w tym dla 13 modeli wkładek piankowych, 10 skrzydełkowych, 5 ze sprężyną dociskową i dla 1 modelu ze trzpieniem. Wyniki Tłumienie wkładek przeciwhałasowych wynosiło 12,9–33,2 dB dla pasma 1/3-oktawowego o częstotliwości środkowej 10 kHz, 22,8–35,2 dB dla pasma 12,5 kHz i 29,5–37,2 dB dla pasma 16 kHz. W zakresie częstotliwości 10–16 kHz tłumienie wkładek przeciwhałasowych przyjmowało większe wartości (istotne statystycznie) w przypadku wkładek piankowych niż wkładek skrzydełkowych (p = 0,0003 vs p = 0,0006) czy wkładek ze sprężyną dociskową (p = 0,0002 vs p = 0,04). Wnioski Wyniki badań wykazały brak jednorodnego związku między tłumieniem dźwięku w zakresie częstotliwości 10–16 kHz a katalogowym parametrem H (tłumieniem wysokoczęstotliwościowym) wkładek przeciwhałasowych. W związku z tym nie ma możliwości prostego wyznaczania tłumienia hałasu ultradźwiękowego w zakresie częstotliwości 10–16 kHz, np. wykorzystując dane dotyczące tłumienia dźwięku dla standardowo rozpatrywanego zakresu częstotliwości (do 8 kHz). Med. Pr. 2018;69(4):395–402
Background The aim of the study was to determine attenuation of earplugs for ultrasonic noise in the frequency range of 10–16 kHz. Material and Methods The attenuation of earplugs in 1/3-octave-bands with the centre frequencies of 10 kHz, 12.5 kHz, and 16 kHz using the REAT (real-ear attenuation at threshold) method based on the measurements of hearing threshold of subjects. The study was carried out for 29 models of earplugs commonly used in the industry designed by various manufacturers, including 13 models of foam earplugs, 10 models of flanged earplugs, 5 models of headband earplugs and one model of no-roll earplugs. Results The values of the measured attenuation of earplugs are in the range 12.9–33.2 dB for the 10 kHz frequency band, 22.8–35.2 dB for the 12.5 kHz frequency band and 29.5–37.2 dB for the 16 kHz frequency band. The attenuation of earplugs in the frequency range 10–16 kHz has higher values (statistically significant changes) for foam earplugs than flanged earplugs (p = 0.0003 vs. p = 0.0006) or headband earplugs (p = 0.0002 vs. p = 0.04). Conclusions The tests indicated that there is no uniform relation between the sound attenuation in the frequencies range of 10–16 kH and the catalogue H parameter (high-frequency attenuation value) of earplugs. Therefore, it is not possible to easily predict the attenuation of ultrasonic noise in the frequency range of 10–16 kHz using the sound attenuation data for the normally considered frequency range (up to 8 kHz). Med Pr 2018;69(4):395–402
Źródło:
Medycyna Pracy; 2018, 69, 4; 395-402
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Impulse Noise Hazard and the Use of Hearing Protection Devices in Workplaces where Forging Hammers are Used
Autorzy:
Młyński, R.
Kozłowski, E.
Adamczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/176721.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impulse noise
noise attenuation
hearing protection device
die forging hammer
Opis:
The impulse noise is agent harmful to health not only in the case of shots from firearms and the explosions of explosive materials. This kind of noise is also present in many workplaces in the industry. The paper presents the results of noise parameters measurements in workplaces where four different die forging hammers were used. The measured values of the C-weighted peak sound pressure level, the A-weighted maximum sound pressure level and A-weighted noise exposure level normalized to an 8 h working day (daily noise exposure level) exceeded the exposure limit values. For example, the highest measured value of the C-weighted peak sound pressure level was 148.9 dB. In this study possibility of the protection of hearing with the use of earplugs or earmuffs was assessed. The measurement method for the measurements of noise parameters under hearing protection devices using an acoustical test fixture instead of testing with the participation of subjects was used. The results of these measurements allows for assessment which of two tested earplugs and two tested earmuffs sufficiently protect hearing of workers in workplaces where forging hammers are used.
Źródło:
Archives of Acoustics; 2014, 39, 1; 73-79
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Attenuation of Noise by Motorcycle Safety Helmets
Autorzy:
Młyński, R.
Kozłowski, E.
Żera, J.
Powiązania:
https://bibliotekanauki.pl/articles/89964.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
noise attenuation
measurements on subjects
motorcycle helmets
motorcyclist conditions of work
Opis:
For workers such as police motorcyclists or couriers, traffic and engine noise reaching the ears is an important factor contributing to the overall condition of their work. This noise can be reduced with motorcycle helmets. In this study, insertion loss of motorcycle helmets was measured with the microphone-in-real-ear technique and sound attenuation with the real-ear-at-threshold method. Results for 3 Nolan helmets show essentially no protection against external noise in the frequency range <250 Hz. In the frequency range >500 Hz, attenuation increases linearly at a rate of 8–9 dB per octave, to ~30 dB at 8 kHz. Lack of attenuation in the low-frequency range may cause annoying effects. In addition, high attenuation in the high-frequency range may decrease intelligibility of speech signals for a rider in a helmet. Attenuation measured in this study does not take into account noise generated by turbulent wind around the helmet. Thus, the measured values of attenuation represent a motorcycle rider’s best conditions of hearing.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 3; 287-293
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining Attenuation of Impulse Noise With an Electrical Equivalent of a Hearing Protection Device
Autorzy:
Młyński, R.
Kozłowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/91027.pdf
Data publikacji:
2013
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
impulse noise
noise attenuation
hearing protectors
transfer function of hearing protection device
hałas impulsowy
ochrona słuchu
ochrona przed hałasem
środki ochrony indywidualnej
tłumienie hałasu
Opis:
Determining the effectiveness of impulse noise attenuation with hearing protection devices (HPDs) is an important part of their selection. Measuring impulse noise parameters under an HPD would involve exposing subjects to impulses with a high peak sound pressure level. This paper presents a computational method of determining impulse noise parameters under the cups of earmuffs. Calculations are done using the transfer function of earmuffs, determined with Shaw's electrical equivalent of an HPD, taking into account the design parameters of earmuffs. The developed method was used for calculations in the presence of impulse noise generated by gunshots. To verify the computational method, the results of these calculations were compared with the results of measurements.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2013, 19, 1; 127-141
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tłumienie dźwięku hełmofonu czołgisty
Sound attenuation of tanker’s headphone
Autorzy:
Młyński, R.
Kozłowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/210392.pdf
Data publikacji:
2015
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
akustyka
ochrona przed hałasem
hałas
tłumienie dźwięku
acoustics
noise control
noise
sound attenuation
Opis:
Załoga pojazdu bojowego, która jest narażona na hałas związany z pracą silnika, jak i z wystrzałami z broni palnej, ma na swoim wyposażeniu hełmofony. W artykule przedstawiono wyniki badań ograniczania hałasu przez hełmofon HC-98 w przypadku hałasu ustalonego oraz impulsowego. Stosowano dwie metody badań: pomiary tłumienia dźwięku z udziałem osób oraz pomiary tłumienia przenoszenia impulsów akustycznych przeprowadzane z użyciem testera akustycznego - urządzenia odwzorowującego głowę. Dane dla hełmofonu porównano ze skutecznością ograniczania hałasu przez dwa różne, powszechnie stosowane nauszniki przeciwhałasowe (jeden słabo, drugi silnie ograniczający hałas). Wyniki wskazały, że hełmofon spełnia wymagania, które pozwalają traktować go jako ochronnik słuchu, jednak nie zapewnia on ochrony słuchu takiej jak nauszniki przeciwhałasowe. Otrzymano stosunkowo niskie wartości tłumienia impulsów akustycznych przez badany hełmofon względem wyników dla nauszników przeciwhałasowych. Ponadto, w przypadku hełmofonu, w zakresie częstotliwości 63-2000 Hz, uzyskano niższe od około 2 do nawet 19 dB wartości tłumienia hałasu ustalonego w porównaniu z wartościami tłumienia nauszników.
Crew of military vehicles, which is exposed to the noise associated with the engine running, as well as to shots from firearms, is equipped with headphones. The article presents the results of noise reduction by HC-98 headphone for steady state and impulsive noise. Two methods of research were used: sound attenuation measurements with participation of subjects and transmission loss measurements with the use of acoustic test fixture - device reflecting the properties of the head. Data for headphone were compared with noise reduction of two different, commonly used earmuffs (one light, the other strong limiting noise). The results indicated that measured headphone meets the requirements that allow for treating it as hearing protection, however, this headphone does not provide hearing protection such as earmuffs. Relatively low values of attenuation of acoustic impulses through the headphone versus the results for earmuffs were observed. Furthermore, in the case of headphone, in the frequency range 63-2000 Hz, the lower values of steady state noise sound attenuation, from about 2 up to even a 19 dB with respect to the attenuation of ear muffs were measured.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2015, 64, 1; 79-90
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noise reduction at the shooting range by means of level-dependent hearing protectors
Autorzy:
Młyński, Rafał
Kozłowski, Emil
Powiązania:
https://bibliotekanauki.pl/articles/2162681.pdf
Data publikacji:
2019-06-14
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
impulse noise
earplugs
attenuation
earmuffs
noise reduction
level-dependent hearing protectors
Opis:
Background The aim of the tests was to establish the possibilities of reducing impulse noise by using level-dependent hearing protectors at a shooting range. The tests included 9 models of level-dependent earmuffs and 2 models of level-dependent earplugs. They were conducted in the presence of impulse noise generated by 7 types of firearms (pistols, a submachine gun, rifles, a shotgun). Material and Methods The tests were conducted at an outdoor shooting range, using an acoustic test fixture that meets the requirements of the ANSI/ASA S12.42-2010 standard. Noise parameters were established for the noise reaching the microphones installed in the ear simulators of the acoustic test fixture: uncovered and protected by the tested hearing protectors. Results All 11 tested level-dependent hearing protectors allow to satisfactorily (below the exposure limit values) reduce the C-weighted peak sound pressure level and A-weighted maximum sound pressure level parameters of noise produced during shots from the 7 types of firearms included in the study. Moreover, in the most unfavorable case, the permissible number of impulses due to the value of the A-weighted noise exposure level normalized to an 8-h working day parameter exceeds 5000 per day. Conclusions Level-dependent hearing protectors constitute the appropriate means to protect the hearing of people at a shooting range, while maintaining the functionality of these protection devices to transmit speech signals. Med Pr. 2019;70(3):265–73
Źródło:
Medycyna Pracy; 2019, 70, 3; 265-273
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data partitioning based weighted averaging for noise suppression in biomedical signals
Autorzy:
Momot, A.
Jezewski, J.
Wrobel, J.
Powiązania:
https://bibliotekanauki.pl/articles/951703.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
ważone uśrednianie
tłumienie hałasu
weighted averaging
noise attenuation
quasi-cyclic biomedical signal
Opis:
In the case of biomedical signals with a quasi-cyclic character, such as electrocardiographic signals, the high resolution electrocardiograms or electrical potentials recorded from the nervous system of patients (estimating brain activity evoked by a known stimulus), as a method of averaging in the time domain may be used for noise attenuation. In this paper there is presented input data partitioning applied to a few different methods of weighted averaging. This procedure usually leads to improve the quality of the resulting averaged signal, especially when fuzzy partitioning is used. Below it is presented the computational study of weighted averaging with traditional (sharp) and fuzzy partition of the input data in the presence of non-stationary noise. The performance of presented methods is experimentally evaluated for analytical signal of EN 60601-2-51 (2003), namely ANE20000 ECG record.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 20; 85-91
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies