Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "negative resistance" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
A 24 GHz PHEMT-based oscillator
Autorzy:
Lewandowski, A.
Kompa, G.
Mwema, W.
Wiatr, W.
Powiązania:
https://bibliotekanauki.pl/articles/309225.pdf
Data publikacji:
2003
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
generator mikrofalowy
opór ujemny
microwave oscillator
oscillator design method
negative resistance
describing function
nonlinear PHEMT model
microstrip components models
Opis:
We present a systematic nonlinear procedure for designing microwave oscillators utilising a nonlinear PHEMT model, the negative resistance approach and the describing function concept. The procedure is applied in the design of a 24 GHz oscillator, which is then realised in hybrid technology. Measurement results show - 6% shift in the frequency but an acceptable agreement in the output power. A detailed analysis shows that the frequency shift arises mainly from inadequate CAD models in the K band, for the microstrip components employed in our design.
Źródło:
Journal of Telecommunications and Information Technology; 2003, 1; 15-19
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on a magnetic field sensor with a frequency output signal based on a tunnel-resonance diode
Badania magnetycznego czujnika pola z sygnałem wyjściowym częstotliwościowym w oparciu o diodę tunelowo-rezonansową
Autorzy:
Osadchuk, Alexander. V.
Osadchuk, Vladimir. S.
Osadchuk, Iaroslav A.
Powiązania:
https://bibliotekanauki.pl/articles/1841342.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
self-oscillator
tunneling resonant diode
negative differential resistance
frequency
quantum heterostructure
samoscylator
tunelowa dioda rezonansowa
ujemna rezystancja różnicowa
częstotliwość
heterostruktura kwantowa
Opis:
Based on the consideration of physical processes in a tunnel-resonant diode under the action of a magnetic field, the construction of an autogenerating magnetic field sensor with a frequency output signalis proposed. The use of devices with negative differential resistance makes it possible to significantly simplify the design of magnetic field sensors in the entire RF frequency range. Depending on the operating modes of the sensor, anoutput signal can be obtained in the form of harmonic oscillations, as well as in the form of pulse oscillations of a special form.The study of the characteristics of the magnetic field sensor is based on the complete equivalent circuit of the tunnel-resonant diode.Theequivalent circuit takes into account both the capacitive and inductive properties of the tunneling resonant diode.The inductive component exists under any operating conditions, as a result of the fact that the current flowing through thedevice is always lagging behind the voltage that caused it, which corresponds to the inductive response of a tunnel-resonant diode.
Na podstawie uwzględnienia procesów fizycznych zachodzących w diodzie tunelowo-rezonansowej pod działaniem pola magnetycznego proponuje się skonstruowanie autogeneracyjnego czujnika pola magnetycznego o częstotliwościowym sygnale wyjściowym. Zastosowanie urządzeń o ujemnej rezystancji różnicowej pozwala znacznie uprościć konstrukcję czujników pola magnetycznego w całym zakresie częstotliwości RF. W zależności od trybu pracy czujnika sygnał wyjściowy można uzyskać w postaci oscylacji harmonicznych, a także w postaci oscylacji impulsów ospecjalnej postaci.Badanie charakterystyk czujnika pola magnetycznego opiera się na pełnym obwodzie zastępczym tunelowej diody rezonansowej. Obwód zastępczy uwzględnia zarówno właściwości pojemnościowe, jak i indukcyjnetunelowej diody rezonansowej. Składowa indukcyjna istnieje w każdych warunkach pracy, na skutek tego, że prąd przepływający przez urządzenie jest zawsze opóźniony w stosunku do napięcia, które go spowodowało, co odpowiada odpowiedzi indukcyjnej diody tunelowo-rezonansowej.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 4; 51-56
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on a magnetic field sensor with a frequency output signal based on a tunnel-resonance diode
Badania magnetycznego czujnika pola z sygnałem wyjściowym częstotliwościowym w oparciu o diodę tunelowo-rezonansową
Autorzy:
Osadchuk, Alexander. V.
Osadchuk, Vladimir. S.
Osadchuk, Iaroslav A.
Powiązania:
https://bibliotekanauki.pl/articles/1841376.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
self-oscillator
tunneling resonant diode
negative differential resistance
frequency
quantum heterostructure
samoscylator
tunelowa dioda rezonansowa
ujemna rezystancja różnicowa
częstotliwość
heterostruktura kwantowa
Opis:
Based on the consideration of physical processes in a tunnel-resonant diode under the action of a magnetic field, the construction of an autogenerating magnetic field sensor with a frequency output signalis proposed. The use of devices with negative differential resistance makes it possible to significantly simplify the design of magnetic field sensors in the entire RF frequency range. Depending on the operating modes of the sensor, anoutput signal can be obtained in the form of harmonic oscillations, as well as in the form of pulse oscillations of a special form.The study of the characteristics of the magnetic field sensor is based on the complete equivalent circuit of the tunnel-resonant diode.Theequivalent circuit takes into account both the capacitive and inductive properties of the tunneling resonant diode.The inductive component exists under any operating conditions, as a result of the fact that the current flowing through thedevice is always lagging behind the voltage that caused it, which corresponds to the inductive response of a tunnel-resonant diode.
Na podstawie uwzględnienia procesów fizycznych zachodzących w diodzie tunelowo-rezonansowej pod działaniem pola magnetycznego proponuje się skonstruowanie autogeneracyjnego czujnika pola magnetycznego o częstotliwościowym sygnale wyjściowym. Zastosowanie urządzeń o ujemnej rezystancji różnicowej pozwala znacznie uprościć konstrukcję czujników pola magnetycznego w całym zakresie częstotliwości RF. W zależności od trybu pracy czujnika sygnał wyjściowy można uzyskać w postaci oscylacji harmonicznych, a także w postaci oscylacji impulsów ospecjalnej postaci.Badanie charakterystyk czujnika pola magnetycznego opiera się na pełnym obwodzie zastępczym tunelowej diody rezonansowej. Obwód zastępczy uwzględnia zarówno właściwości pojemnościowe, jak i indukcyjnetunelowej diody rezonansowej. Składowa indukcyjna istnieje w każdych warunkach pracy, na skutek tego, że prąd przepływający przez urządzenie jest zawsze opóźniony w stosunku do napięcia, które go spowodowało, co odpowiada odpowiedzi indukcyjnej diody tunelowo-rezonansowej.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 4; 51-56
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self-oscillating parametric humidity sensor with frequency output signal
Samooscylacyjny parametrycznyczujnik wilgotności z częstotliwościowym sygnałem wyjściowym
Autorzy:
Osadchuk, Iaroslav O.
Osadchuk, Oleksandr V.
Osadchuk, Vladimir. S.
Krylik, Lyudmila. V.
Powiązania:
https://bibliotekanauki.pl/articles/27315405.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
self-oscillating parametric humidity sensor with frequency output
negative differential resistance
humidity-sensitive resistor
samooscylacyjny parametryczny czujnik wilgotności z wyjściem częstotliwościowym
ujemna rezystancja różnicowa
rezystor wrażliwy na wilgoć
Opis:
A self-oscillating parametric humidity sensor has been developed that implements the principle of "humidity-frequency" conversion into hybrid integrated circuit based on a microelectronic transistor structure with a negative differential resistance, in which the humidity-sensitive element is a resistor of the HR202 type. For the purposes of determining parameters self-oscillating parametric humidity sensor with frequency output a mathematical model has been developed that takes into account the effect of humidity on a sensitive resistive element, which is an integral element of the device. Based on the mathematical model, analytical expressions for the transformation function and the sensitivity equation are obtained. It is shown that the main contribution to the conversion function is made by relative humidity. The computer simulation and experimental studies of a self-oscillating parametric humidity sensor with a frequency output signal contributed to obtaining the main parameters and characteristics, such as the dependence of the generation frequency on changes in relative humidity in the range from 30% to 99%, the change in sensitivity on relative humidity, the dependence of the active and reactive components of the impedance in the frequency range from 50 kHz to 2 GHz; standing wave ratio, change in logarithmic magnitude and spectra of the output signal of a parametric humidity sensor with a frequency output signal in the LTE-800 Downlink frequency range. The obtained electrical characteristics confirm the operability of the developed device. The sensitivity of the developed self-oscillating parametric humidity sensor in the range of relative humidity change from 30% to 99% has a value from 332.8 kHz/% to 130.2 kHz/%.
Opracowano samooscylujący parametryczny czujnik wilgotności realizujący zasadę konwersji „wilgotność-częstotliwość” do hybrydowego układu scalonego opartego na mikroelektronicznej strukturze tranzystorowej o ujemnej rezystancji różnicowej, w której elementem czułym na wilgotność jest rezystor typu HR202 typ. Na potrzeby wyznaczania parametrów samooscylującego parametrycznego czujnika wilgotności z wyjściem częstotliwościowym opracowano model matematyczny uwzględniający wpływ wilgoci na czuły element rezystancyjny, będący integralną częścią urządzenia. Na podstawie modelu matematycznego uzyskuje się wyrażenia analityczne dla funkcji transformacji i równania wrażliwości. Pokazano, że główny udział w funkcji konwersji ma wilgotność względna. Symulacja komputerowa i badania eksperymentalne samooscylującego parametrycznego czujnika wilgotności z wyjściowym sygnałem częstotliwościowym przyczyniły się do uzyskania głównych parametrów i charakterystyk, takich jak zależność częstotliwości generacji od zmian wilgotności względnej w zakresie od 30% do 99%, zmiana czułości na wilgotność względną, zależność składowej czynnej i reaktywnej impedancji w zakresie częstotliwości od 50 kHz do 2 GHz; współczynnika fali stojącej, zmiany wielkości logarytmicznej i widma sygnału wyjściowego parametrycznego czujnika wilgotności przy częstotliwościowym sygnale wyjściowym w zakresie częstotliwości LTE-800 Downlink. Uzyskane charakterystyki elektryczne potwierdzają sprawność opracowanego urządzenia. Czułość opracowanego samooscylującego parametrycznego czujnika wilgotności w zakresie zmian wilgotności względnej od 30% do 99% przyjmuje wartość od 332,8 kHz/% do 130,2 kHz/%.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 1; 42--49
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The power of denial. From denial to creation: creative resistance in the city of Athens
Autorzy:
Zafeiris, Konstantinos
Powiązania:
https://bibliotekanauki.pl/articles/28407241.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
negative dialectic
creative resistance
self-organization
autonomy
Athens
Opis:
The crisis leads to multiple denials in the face of everyday life and the conditions of reproduction of work it imposes. In this paper, I describe the basic denials in spaces of creative resistance in Athens during multiple crises. Through a systematic study of collaborative economy spaces, solidarity structures, and independent art spaces, I discern a progression of individuals from denial to creation and ultimately to action. I also strive to articulate the emerging modes of mobilization within these spaces. Faced with this reality, the act of denial emerges as the primary and transformative catalyst, sparking the forces of creativity and resistance. The denials of everyday life imposed by neoliberalism, as witnessed in Athens during the crisis, resulted in the creation of autonomous and self-organized spaces.
Źródło:
Przegląd Krytyczny; 2023, 5, 2; 33-52
2657-8964
Pojawia się w:
Przegląd Krytyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Daptomycin-resistant Staphylococcus pettenkoferi of human origin
Autorzy:
Savini, Vincenzo
Kosecka, Maja
Siegwart, Ed
Marrollo, Roberta
Polilli, Ennio
Palmieri, Dalia
Fazii, Paolo
Carretto, Edoardo
Międzobrodzki, Jacek
Bukowski, Michal
Powiązania:
https://bibliotekanauki.pl/articles/1038817.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
daptomycin resistance
coagulase-negative staphylococci
Staphylococcus pettenkoferi
Klebsiella pneumoniae
Opis:
The importance of nosocomial infections caused by coagulase-negative staphylococci is constantly growing. The threat primarily affects immunocompromised patients, the elderly and neonates, particularly after invasive surgery. The problem is fundamentally exacerbated by expanding antibacterial drug resistance. A case report is presented of an 86-year-old patient who underwent a ruptured abdominal aortic aneurysm surgery and developed septicaemia upon surgical wound infection. The causal agent was likely a carbapenem-resistant Klebsiella pneumoniae, however, daptomycin-resistant Staphylococcus pettenkoferi was identified in blood cultures in the absence of daptomycin treatment. To the authors' knowledge, the case study presented is the first published episode of daptomycin-resistant S. pettenkoferi strain.
Źródło:
Acta Biochimica Polonica; 2016, 63, 2; 297-301
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multidrug-resistant strains of coagulase-negative staphylococci isolated from patients with chronic sinusitis – MDR, XDR, PDR strains
Autorzy:
Michalik, Michał
Podbielska-Kubera, Adrianna
Samet, Alfred
Konopka, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/1397490.pdf
Data publikacji:
2020
Wydawca:
Index Copernicus International
Tematy:
antibiotic resistance
chronic sinusitis
coagulase-negative staphylococci
epidemiology
nosocomial infections
virulence factors
Opis:
Introduction: The development of resistance to multiple antimicrobial agents in pathogenic bacteria has become a threat to public health. Multidrug-resistant strains that are particularly dangerous include MDR, XDR and PDR strains. Material and methods: Aspirate material from paranasal sinuses, obtained from patients with chronic sinusitis undergoing functional endoscopic sinus surgery (FESS) in Medical Center MML in Warsaw, was subjected to bacteriologic analysis. The isolated strains were identified to the species level and tested for antibiotic resistance. Then, minimal inhibitory concentration (MIC) was determined. R esults: The isolated strains of coagulase-negative staphylococci were resistant mainly to macrolides, aminoglycosides and tetracycline. Nine of the isolated strains exhibited multidrug-resistance. Discussion: Bacteria causing chronic sinusitis are becoming increasingly resistant to antimicrobial agents. The diagnostic process for coagulase-negative staphylococci (CNS) is often limited to the identification of species, or even genus of the bacteria. The CNS strains are considered to be non-pathogenic and they are not subject to eradication. This may lead to erroneous therapeutic decisions and, consequently, to the development of antibiotic resistance. CNS infections are classified as nosocomial and therefore, appropriate epidemiological procedures have to be followed. The authors highlight the necessity to determine MIC values for antibiotics and to introduce personalized treatment.
Źródło:
Polish Journal of Otolaryngology; 2020, 74, 2; 36-41
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies