Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "nawiew" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Study on 3-D Flow Patterns in Yarn Channels of an Interlacer
Badania charakterystyki przepływu 3D w dyszy komory przędącej urządzenia przeplatającego
Autorzy:
Qiu, H
Liu, Y.
Zhang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/233558.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
interlacer
flow patterns
computational fluid dynamics (CFD)
performance
przepływ strumienia powietrza
nawiew
obliczeniowa dynamika płynów
wydajność
Opis:
The aim of the present work was to determine the flow characteristics of compressible airflow in the yarn channel of an interlacer by numerical simulations to make clear the effects of cross-sectional shapes of the yarn channel on the performance of interlacers. CFD (Computational Fluid Dynamics) software package ANSYS CFX was used to calculate flow patterns in the yarn channel. Relations between the performance of the interlacer and distribution of the velocity vector, airflow speed and particle trace of the flow were clarified to provide knowledge to design better interlacers.
Celem pracy było określenie charakterystyk przepływu strumienia powietrza w dyszy komory przędącej urządzeń przeplatających za pomocą numerycznych symulacji dla wyjaśnienia wpływu kształtu przekroju kanałów prowadzących przędze na jakość pracy urządzenia przeplatającego. Program CFD (komputerowe określanie dynamiki przepływu) oparty na ANSYS CFX stosowano dla obliczeń przebiegów przepływu w dyszach przędzy. Dla uzyskania wiedzy potrzebnej dla lepszego projektowania urządzeń przeplatających badano zależności pomiędzy pracą tych urządzeń, rozkładem wektorów prędkości, szybkości przepływu oraz kształtu strumieni.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 1 (103); 56-61
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systemy oddymiania klatek schodowych – zalety i ograniczenia stosowanych rozwiązań technicznych
Stairwell Smoke Exhaust Ventilation Systems– Advantages and Limits of Applied Technical Solutions
Autorzy:
Kubicki, G.
Kiełbasa, T.
Wiche, J.
Powiązania:
https://bibliotekanauki.pl/articles/372888.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
klatki schodowe
oddymianie grawitacyjne
nawiew mechaniczny
wentylator oddymiający
stairwell
natural smoke ventialation
mechanical air supply
smoke exhaust fan
Opis:
Cel: Celem artykułu jest przedstawienie właściwości różnych systemów odprowadzania dymu i ciepła z przestrzeni klatek schodowych. Wprowadzenie: Oddymianie klatek schodowych stanowi fakultatywne rozwiązanie dopuszczone przez krajowe przepisy jako alternatywa dla doskonalszych, ale droższych systemów różnicowania ciśnienia. W artykule skoncentrowano się głównie na ograniczeniach i poważnych zagrożeniach związanych z nieświadomym zastosowaniem różnych konfiguracji urządzeń służących do oddymiania. Analizie poddano systemy oddymiania grawitacyjnego, oddymiania z wykorzystaniem wentylatorów wyciągowych oraz najnowsze rozwiązania oddymiania pionowych dróg ewakuacji wspomaganych zmiennym nawiewem. Metodologia: Postawione w artykule tezy wynikają m.in. z wieloletnich doświadczeń eksploatacyjnych. Słuszność przedstawionych założeń udowodniona została na podstawie wyników prowadzonych przy udziale autorów testów obiektowych i pełnowymiarowych prób pożarowych in-situ oraz analiz numerycznych. Podczas realizacji programu badawczego pt. „Bezpieczna ewakuacja” zostały porównane m.in. zasady działania wymienionych wyżej systemów oddymiania klatek schodowych, w różnych warunkach rozwoju pożaru i przy dynamicznie zmieniającym się stanie szczelności klatki schodowej (zmianie położenia drzwi na kondygnacji objętej pożarem i na poziomie wyjścia z budynku oraz po wypadnięciu okien w pomieszczeniu testowym). Przeprowadzone badania były realizowane w obiekcie rzeczywistym, o architekturze reprezentatywnej dla najwyższych budynków klasyfikowanych jako średniowysokie (SW wg [1]). Stanowisko badawcze zostało wyposażone w aparaturę pomiarową oraz urządzenia do monitoringu, sterowania oraz zbierania i archiwizacji danych. Równolegle do badań obiektowych prowadzone były analizy numeryczne oparte o modele walidowane w czasie prób dymowych i testów pożarowych. Wnioski: Wszystkie przeprowadzone testy wyraźnie wskazują na najwyższą skuteczność systemów oddymiania klatek schodowych wspomaganych nawiewem mechanicznym, przy czym systemy tego typu muszą zostać wyposażone w wentylatory o zmiennym wydatku. Więcej ograniczeń efektywności działania wykazuje oddymianie grawitacyjne. Ograniczenia te dotyczą m.in. wyraźnego spadku efektywności oddymiania przy niskich temperaturach gazów pożarowych (w warunkach nie w pełni rozwiniętego pożaru), przy niekorzystnym układzie różnicy temperatury w przestrzeni klatki schodowej i na zewnątrz budynku oraz podatności systemu na oddziaływanie wiatru. Za niewłaściwe, a nawet niebezpieczne, należy uznać wykorzystanie wentylatorów oddymiających do ukierunkowania przepływu powietrza i dymu przez klatki schodowe. Artykuł może stanowić przydatne źródło informacji dla wszystkich osób uczestniczących w wyborze oraz projektowaniu systemów oddymiania klatek schodowych.
Aim: The aim of this article is to present the characteristics of various stairwell heat and smoke exhaust ventilation systems. Introduction: Stairwell smoke exhaust ventilation represents a facultative solution approved by Polish law as an alternative to more effective, but expensive pressure reduction systems. The article concentrates on limits and serious threats associated with unaware use of various configurations of smoke ventilation devices. The analysis involved: natural smoke and heat exhaust ventilation systems, exhaust ventilation systems with powered ventilators (fans) as well as the newest solutions for smoke removal from vertical escape routes with mechanically-aided air supply. Methodology: All arguments presented in this paper are based on the authors’ many years operational experience. Provided information was confirmed by the results of numerical analyses as well as field research and full-size in-situ fire tests carried out in the presence of the authors. Realisation of the research programme “Bezpieczna ewakuacja” (Safe Evacuation) involved a comparison of, i.a., the operation principles of the stairwell smoke ventilation systems in various conditions of fire development and during dynamically changing stairwell leaktightness (by adjustment of doors position on the floor of fire origin and on the bottom floor as well as after a window break in the test room). The tests were carried out in a real building, characterized by the architecture features representative for the tallest buildings in Poland classified as SW (medium-height), according to [1]. The test stand was equipped with measuring, monitor, control, data collection and archive systems. Together with the field research, the authors performed numerical analyses based on models, validated in the course of hot smoke and fire tests. Conclusions: All performed tests clearly show that stairwell ventilation systems aided by a mechanical air supply work the most efficiently, but they should be equipped with performance-regulated fans. Natural smoke exhaust systems have the most limitations. They include clear loss of efficiency at low temperatures of combustion gases (in the initial phase of fire development), at disadvantageous difference of temperatures between a stairwell and outside area, and system’s vulnerability to wind influence. The use of powered mechanical ventilators (fans) for exhaust of air and smoke from the building stairwell ought to be considered inappropriate or even dangerous. Presented paper may constitute a useful source of information for everyone who participates in a choice or design of stairwell smoke ventilation systems.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 142-153
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nawiewu bocznego wspomagającego na skuteczność usuwania zanieczyszczeń powietrza ze stanowiska spawalniczego
The impact of the use of side air supply on the efficiency of removing air pollution emission from a welding station
Autorzy:
Jankowski, Tomasz
Sobiech, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/31342474.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
nawiew powietrza
miejscowa wentylacja wywiewna
prędkość powietrza
dym spawalniczy
air supply
local exhaust ventilation
air velocity
welding fumes
Opis:
Prawidłowe zaprojektowanie systemu wentylacji na stanowisku spawania wymaga ustalenia przepływu dymów spawalniczych oraz określenia podstawowych parametrów procesowych spawania. Na podstawie przeglądu rozwiązań wentylacyjnych, stosowanych do ochrony człowieka przed zanieczyszczeniami powietrza, występującymi podczas prac spawalniczych, oraz przeprowadzonej analizy środowiska pracy spawaczy, wytycznych i dokumentów normatywnych możliwy jest wybór najlepszego wariantu przepływu powietrza przez urządzenia i odciągi miejscowe. Dotychczasowe rozwiązania dotyczące instalacji wentylacji stanowisk spawalniczych okazują się nie w pełni skuteczne pod kątem wychwytywania cząstek pyłów i dymów spawalniczych. Jeżeli już zapewniają efektywne usuwanie dymów spawalniczych, wymagane jest zastosowanie dużych strumieni powietrza wywiewanego. Na podstawie wyników badań stwierdzono, że wspomaganie bocznym nawiewem umożliwia zwiększenie skuteczności wychwytu i skrócenie czasu przepływu dymów spawalniczych ze strefy roboczej spawania do strefy górnej. Zastosowanie nawiewu wspomagającego pozwoliło na poprawienie zasięgu skutecznego działania odciągu miejscowego w procesie spawania.
The correct design of the ventilation system at the welding station requires the determination of the welding fumes flows and the definition of the basic welding process parameters. On the basis of the review of ventilation solutions used to protect man against air pollution occurring during welding work and conducted analysis of the work environment of welders, guidelines and normative documents, it is possible to choose the best variant of air flow through the devices and local exhausts. The existing solutions for the installation of ventilation of welding stations are not fully effective in terms of capturing particles of welding dust and fumes. If they already provide a sufficiently effective removal of welding fumes, this requires the use of large exhaust air streams. Based on the test results, it was found that the lateral supply support allows to increase the capture efficiency and reduce the flow of welding fumes from the welding work zone to the upper zone. The use of supportive ventilation allowed to improve the range of effective local exhaust ventilation in the welding process.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2022, 3; 20-25
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of energy-saving air supply in small-size rooms with high-heat locations
Opracowanie energoefektywnego dopływu powietrza do pomieszczeń o niedużej objętości ze źródłami ciepła
Autorzy:
Dovhaliuk, V.
Mileykovsky, V.
Klymenko, G.
Powiązania:
https://bibliotekanauki.pl/articles/2065361.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
air distribution
high-heat area
displacement ventilation
low-speed air distributor
turbulent jet
nawiew powietrza
wentylacja wyporowa
dystrybutor powietrza
Opis:
It is well known that the most effective method of air distribution in high-heat areas is displacement ventilation with a variable air loss according to changeable operating conditions. Dense equipment arrangement makes requirements to air distribution even higher. The necessity of spreading jets till they reach convective flows is shown. To slow down these jets uniform air supply is required at the exit of an air distributor. Modern devices do not fully meet this requirement. The suggested method of air supply ensures uniform air distribution and thorough ventilation of the area at a changed expenditure of inflowing air.
Wiadomo, że najbardziej skutecznym sposobem nawiewu powietrza do pomieszczeń ze źródłami ciepła jest wentylacja wyciągowa ze zmiennym przepływem powietrza w zmiennych warunkach eksploatacyjnych. Zwiększanie szczelności pomieszczeń podwyższa wymagania do nawiewu powietrza. Aby zmniejszyć prędkość strumieni, należy zapewnić równomierny przepływ powietrza na wyjściu z jednostki nawiewu powietrza. Stosowane metody wentylacji na ogół nie spełniają tego wymogu. Zaproponowany sposób dopływu powietrza pozwala zapewnić równomierność dostarczania powietrza i likwidację nieprzewietrzanych stref przy zmianie wydatku przepływu powietrza.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 15--23
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies