Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "natural wind" wg kryterium: Temat


Wyświetlanie 1-21 z 21
Tytuł:
Experimental study of the aerodynamics of sail in natural wind
Autorzy:
Zeng, X.
Zhang, H..
Powiązania:
https://bibliotekanauki.pl/articles/259718.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
natural wind
wind sail
aerodynamics
sail assisted ship
Opis:
In order to evaluate the impacts of a motor vessel after installing wind sails, the aerodynamics of the sail should be accurately calculated. However most of the research on sails are based on stable wind instead of natural wind which is changing horizontally and vertically. In this paper wind tunnel tests are carried out based on stable wind field and simulated natural wind field, the results shown that there are 16–44% decrease in natural wind in terms of lifting coefficient and 11–42% decrease for drag coefficient. This would provide a valuable reference to the effectiveness evaluation of the impact of sails for sail assisted ships.
Źródło:
Polish Maritime Research; 2018, S 2; 17-22
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwarunkowania przyrodnicze lokalizacji elektrowni wiatrowych w gminie Szadek
Natural determinants of the location of wind power stations in Szadek minicipality
Autorzy:
Granosik, Ewelina
Kobojek, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/2028734.pdf
Data publikacji:
2021-12-10
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
Wysoczyzna Łaska
Szadek municipality
wind power engineering
natural determinants of wind power stations location
gmina Szadek
energetyka wiatrowa
przyrodnicze czynniki lokalizacji elektrowni wiatrowych
Opis:
W artykule przedstawiono warunki przyrodnicze rozwoju energetyki wiatrowej w gminie Szadek w zachodniej części regionu łódzkiego. Podstawowe znaczenie dla decyzji o budowie siłowni wiatrowych mają warunki wietrzne występujące na obszarze gminy. Miasto Szadek i otaczające go tereny wiejskie gminy znajdują się w III strefie energetycznej wiatru, co oznacza, że wielkość wiatrowych zasobów energetycznych wynosi około 500‒1000 kWh/m2/rok. W tych warunkach budowa siłowni wiatrowych jest opłacalna z punktu widzenia ekonomicznego. Na terenie gminy wybudowano w związku z tym 26 wiatrowych urządzeń energetycznych. Większość z nich zlokalizowana jest w centrum gminy w szerokim pasie o przebiegu północ–południe. Siłownie wzniesiono na powierzchni równinnej wysoczyzny morenowej, zbudowanej z gliny zwałowej. Eksponowana na działanie wiatru równina użytkowana jest rolniczo. Występujące tu głównie uprawy zbóż i roślin okopowych nie hamują w sposób istotny ruchu powietrza, co sprzyja energetycznemu wykorzystaniu siły wiatru.
The article discusses the natural determinants of the development of wind energy in the municipality of Szadek. Of primary importance for the decision on the construction of wind power stations are wind conditions in the area. Szadek and the surrounding rural areas are in III zone of wind energy, which means that wind power resources are about 500–1000 kwh/m2/year. In these conditions the construction of wind power plants is economically profitable. 26 wind turbines have been constructed in Szadek municipality. The majority of them are located in the central belt of moraine heights on the axis north-south, which is an agriculturally used area, but the crops cultivated here do not have an adverse effect on air movement.
Źródło:
Biuletyn Szadkowski; 2021, 21; 109-125
1643-0700
Pojawia się w:
Biuletyn Szadkowski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The natural frequency analysis of a wind turbine with vertical axes
Autorzy:
Mazur, D.
Szczepański, A.
Rudy, M.
Powiązania:
https://bibliotekanauki.pl/articles/114730.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
natural frequency analysis
wind turbine
vibrations
Opis:
The natural frequency analysis of four analytical models of a home wind turbine is presented in this paper. These models are: the rotor of a generator without housing, the rotor of a generator with housing and a stator, the rotor of a wind turbine, and the entire assembly of the wind turbine. By comparison of the received results of these models, evaluation of the variation in natural frequencies was performed. Additionally, interaction of the natural frequencies of the models with excitations was investigated. Moreover, various forms of vibrations, such as bending and torsional mode of the wind turbine rotor, rotor generator and blades, were found. Simplified analytical calculations for evaluation of the bearing stiffness applied to the vibration models were also carried out. The natural frequency analysis was performed in the analytical environment of the Siemens NX software based on NX Advanced module by the use of NASTRAN solver.
Źródło:
Measurement Automation Monitoring; 2015, 61, 12; 535-537
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the chimney cap as a method of improving the effectiveness of natural ventilation in buildings
Autorzy:
Antczak-Jarząbska, Romana
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1573919.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
natural ventilation
chimney cap
ACH
wind effect
effectiveness
Opis:
Adequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the air inside a building fresh. A prediction of the performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long-term cost savings. The worst time in terms of the efficiency of natural ventilation is the spring-autumn transition period [7]. In order to improve the efficiency of natural ventilation, chimney caps are used, among others. They are designed to improve the chimney effect described in colloquial language as a chimney draft. The chimney effect is a physical phenomenon of the formation of a spontaneous flow of a warmer gas, e.g. air, from the bottom up in stem channels [12]. The article analyses the influence of the chimney cowl on the improvement of the chimney effect in an apartment of a multi-family building with natural ventilation. Long-term tests of the chimney draft were carried out for the case without and with a chimney cap. The paper presents the results of the performance (air change rate, ACH) of natural ventilation for a building with an inlet gap measured for the transitional season (between the heating and the summer season). The measurements were performed during a windy period.
Źródło:
Polish Maritime Research; 2020, 3; 168-175
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scenarios to reduce evaporation from class A evaporation pan by using windbreaks
Autorzy:
Oribi, Mustafa O.
Abdulkareem, Asraa K.
Powiązania:
https://bibliotekanauki.pl/articles/118708.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
evaporation basin
windbreaks natural
open water bodies
wind speed
Opis:
Evaporation from reservoirs and lakes is an important processes frequently occurring in dry, hot regions such as Iraq. In order to preserve the environment and to reduce the amount of evaporation from open water bodies in this study, simulation was performed to reduce evaporation from evaporation basin class A by using windbreaks natural (Conocarpus trees). Three basic scenarios were made that depended on the values of the atmospheric elements affecting the evaporation process in summer according to the modified Penman equation for the conditions of Iraq, the climate factors are temperature, solar radiation, wind speed, dew point, and the effect of the number of windbreaks and their height was also introduced in sub- scenario. Experiments have shown that the best sub-scenario for all basic scenarios is when the windbreaks are placed in a direct direction to the wind blowing on the evaporation basin in the form of three rows, each row contains three trees where the windbreaks are in case cross and the height of the trees is 100 cm and the distance between each tree and another, and between each row and row 15 × 15 cm, the results of this subscenario recorded the highest rate of evaporation reduction up to 35% of its original value before using windbreaks.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2020, 29, 3; 343-354
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CFD Analysis of an Innovative Wind Tower Design with Wind-Inducing Natural Ventilation Technique for Arid Climatic Conditions
Autorzy:
Obeidat, Bushra
Kamal, Hammam
Almalkawi, Amal
Powiązania:
https://bibliotekanauki.pl/articles/1839069.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wind tower
computational fluid dynamics
natural ventilation
wind pressure fluctuation
indoor air quality
passive ventilation system
Opis:
Wind towers are passive architectural elements traditionally used to ventilate buildings in the Middle East’s hot and arid regions. Some recent design initiatives in Jordan are particularly interested in using passive systems for natural ventilation. This paper focuses on an innovative wind tower design as a passive ventilation system, which will be integrated into a train station design in Aqaba, Jordan to improve the air quality in indoor spaces and reduce the cooling loads. The design uses wind-induced effects as the motivating forces to improve natural ventilation. The study optimized the wind tower and evaluated its performance using Autodesk Computational Fluid Dynamics (CFD) simulations and Grasshopper Rhino plug-ins. Airflow and distribution through the tower were analyzed using the CFD model. Grasshopper definitions were used to examine the tower efficiency in lowering the indoor air temperature. Simulations indicated the potential of the proposed wind tower to reduce the temperature by 6.164°C and supply the interior space with the required fresh air rates. This article outlines how wind towers can be used in contemporary architecture and incorporate the simulation methods to pave the way for architects to effectively validate the performance of their design proposals at the early design stage.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 86-97
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Residual strength assessment of wind turbine rotor blade composites under combined effects of natural aging and fatigue loads
Autorzy:
Gao, Jian-Xiong
An, Zong-Wen
Ma, Qiang
Bai, Xue-Zong
Powiązania:
https://bibliotekanauki.pl/articles/1841943.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
wind turbine rotor blade
natural aging
fatigue loads
residual strength
composite material
Opis:
In this paper, the combined effects of natural aging and fatigue loads are considered to assess the residual strength of wind turbine rotor blade composites under actual service environments. Firstly, a comprehensive environmental factor (CEF) methodology is adopted to quantify the combined effects of environmental factors on residual strength. Meanwhile, the artificial accelerated aging test data are used to determine the weight coefficients of the CEF. Subsequently, a two-variable function is presented to characterize the relationship among residual strength, aging time and the CEF. The natural aging test data are utilized to estimate the unknown parameters of the two-variable function. Finally, the combined effects of natural aging and fatigue loads are considered, and a residual strength model is proposed to analyze the strength degradation behaviors of the wind turbine rotor blade composites. The results indicate that fatigue loads have negative effect on the residual strength, while natural aging has both positive and negative effects on the residual strength.
Źródło:
Eksploatacja i Niezawodność; 2020, 22, 4; 601-609
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Performance of Natural Fiber Reinforced Composites for Wind Turbine Blade Applications
Autorzy:
Batu, Temesgen
Lemu, Hirpa G
Sirhabizuh, Belete
Powiązania:
https://bibliotekanauki.pl/articles/102545.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
natural fiber
reinforced composites
wind turbine blade
Qblade
włókno naturalne
wzmocniony kompozyt
łopatka turbiny wiatrowej
Opis:
The availability of some form of energy is essential for the human survival and social development. However, the way energy has been generated within the last century has brought forward the quest for the generation of energy without polluting the environment, which is nowadays considered to be the greatest global challenge. The materials used for wind turbine blades can be classified under this challenge of polluting the environment. One of the materials expected to reduce this problem is natural fiber reinforced composite (FRC). Thus, the focus of this paper was to evaluate the potential of different natural FRC materials for small wind turbine blade application. Eleven different natural fibers reinforced composite in epoxy resin were studied. A modified Halphin-Tsai semi-empirical model was used to compute the physical properties of the composites, since it has a good agreement with the experimental results. Stress, deformation, and weight of wind turbine blade under different loadings were analyzed aimed to search for a fiber type that may extend the life span of the blade. Finally, flap wise and edge wise, the longitudinal and torsional natural frequencies were computed numerically by using the finite element method in the Qblade software (QFEM) under different mode types and the effects were analysed. Upon comparing the results with a common composite material for wind turbine blade (E-glass/epoxy), it was observed that the selected natural fiber composites have equivalent and better mechanical performance. The environmental friendliness of natural fibers, i.e. biodegradability, constitutes their advantage as materials of wind turbine blades.
Źródło:
Advances in Science and Technology. Research Journal; 2020, 14, 2; 67-75
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air movement characteristics inside a cow barn with natural ventilation under no-wind conditions in the winter season
Autorzy:
Herbut, P.
Powiązania:
https://bibliotekanauki.pl/articles/61769.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
air movement
cow barn
natural ventilation
no-wind condition
winter season
air circulation
barn
building
Opis:
The paper presents results of air movement observations inside a cow barn (Fermbet construction type) adapted for a loose housing system. The conducted experiments made it possible to determine directions and characteristics of ventilated air flux in selected areas of the building as well as mark out areas where air stood still. In addition, the study offers recommendations regarding effective ventilation systems in the occupied zone under no-wind conditions.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural vibrations of a tower structure in mass-changing conditions due to the icing
Drgania własne konstrukcji wieżowej w warunkach zmieniającej się masy układu wskutek oblodzenia
Autorzy:
Kowalski, W.
Swierczek, E.
Powiązania:
https://bibliotekanauki.pl/articles/40218.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
natural vibration
tower structure
tower model
mass-changing condition
icing
transmission tower
wind-induced resonance
Opis:
The study analyzed the impact of additional tower structure masses on the change of the frequency of its natural vibrations; it also made attempts to mathematical description of this impact. Considerations apply to the tower supporting the lighting system of the city stadium in Ostrowiec Świętokrzyski. The source of additional masses is the icing (frost, rime) and non-structural components constituting the technical equipment of the tower. The analysis was made by modeling by means of the Finite Element Method (FEM) of the structure with the assumption of a one parameter variation of its mass (i.e., the additional mass of all components, structural and non-structural, changes in proportion to one parameter, which is the outer surface of the element on which the ice layer is deposited). Solving the problem of natural vibrations, for subsequent models, representing different intensity of tower's icing, the following natural frequencies have been established. Thus, the increase of the ice-layer thickness on the surfaces from 0 to 2.4 cm caused the reduction of basic natural frequencies by a value, consecutively: for f1 → 26.9%; for f → 27.2%. These values are important from the point of view of technical applications. The findings allow to formulate a postulate that, in the analysis of tower's structure susceptibility to gusts of wind, structure's mass variability resulting from its possible icing was taken into consideration.
W pracy dokonano analizy wpływu dodatkowych mas konstrukcji wieżowej na zmianę częstotliwości jej drgań własnych; dokonano też próby matematycznego opisu tego wpływu. Rozważania dotyczą wieży wsporczej oświetlenia stadionu miejskiego w Ostrowcu Świętokrzyskim. Źródłem dodatkowych mas jest oblodzenie (szron, szadź) oraz elementy niekonstrukcyjne stanowiące wyposażenie techniczne wieży. Analizy dokonano w drodze modelowania metodą elementów skończonych (MES) konstrukcji, przyjmując założenie o jednoparametrycznej zmienności jej masy (to znaczy, że dodatkowa masa wszystkich elementów, konstrukcyjnych i niekonstrukcyjnych zmienia się proporcjonalnie do jednego parametru, którym jest powierzchnia zewnętrzna elementu, na której odkłada się warstwa lodu). Rozwiązując zagadnienie własne drgań dla kolejnych modeli, reprezentujących różne intensywności oblodzenia wieży, wyznaczono wartości kolejnych częstotliwości drgań własnych. I tak, przyrost grubości warstwy lodu na powierzchniach, od 0 do 2,4 cm spowodował redukcję podstawowych częstotliwości drgań własnych o wartości kolejno: dla f1 → 26,9%; dla f2 → 27,2%. Są to istotne wartości z punktu widzenia zastosowań technicznych. Uzyskane wyniki pozwalają na sformułowanie postulatu, aby w analizach podatności konstrukcji wieżowych na porywy wiatru uwzględniana była zmienność masy konstrukcji wynikająca z możliwego jej oblodzenia.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2016, 15, 2
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural ventilation performance of family building in cold climate during windy days
Wydajność wentylacji naturalnej podczas dni wietrznych w budynkach mieszkalnych zlokalizowanych w klimacie chłodnym
Autorzy:
Antczak-Jarząbska, R.
Niedostatkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/328718.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
natural ventilation
CO2 concentration
ACH
wind effect
wentylacja naturalna
koncentracja CO2
efekt wiatru
Opis:
Adequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the fresh air inside a building. A prediction of performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long term cost savings. The paper presents results of performance (air change rate ACH) and effectiveness (CO2 concentration in the breathing zone ƞV and temperature distribution ɛt) of natural ventilation for a building with inlet gap measured for the transitional season (between the heating and the summer season). The measurements were performed during a windy period. The test apartment was located in cold climate. The measurement system measured local climate conditions, indoor climate conditions and air velocities in both vent inlet and outlet.
Odpowiednio zaprojektowana wentylacja naturalna jest najtańszym i najłatwiejszym sposobem skutecznego usuwania zanieczyszczeń wewnątrz pomieszczeń oraz utrzymywania świeżego powietrza wewnątrz budynku. Przewidywanie wydajności i skuteczności wentylacji w celu określenia projektu systemu wentylacyjnego może zapewnić rzeczywiste i długoterminowe oszczędności. W pracy przedstawiono wyniki działania (szybkość wymiany powietrza ACH) i efektywność (stężenie CO2 w strefie oddychania ƞV i rozkład temperatury ɛt) wentylacji naturalnej w budynku, który posiadał nawiewnik okienny. Badania prowadzone były w sezonie przejściowym (między sezonem grzewczym a letnim). Pomiary przeprowadzono podczas okresu wietrznego. Testowe mieszkanie zlokalizowane jest w klimacie chłodnym. System pomiarowy mierzył lokalne warunki klimatyczne, warunki klimatyczne w pomieszczeniach i prędkości powietrza zarówno na wlocie i wylocie z kanałów wentylacyjnych.
Źródło:
Diagnostyka; 2018, 19, 1; 103-116
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processes modelling in two-nave building with natural air exchange
Modelowanie procesów w budynkach dwunawowych z naturalną wymianą powietrza
Autorzy:
Biernacki, K.
Piotrowski, J. Z.
Powiązania:
https://bibliotekanauki.pl/articles/402403.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
natural ventilation
gravitational forces
wind action
multi-zone buildings
wentylacja naturalna
siły grawitacyjne
działanie wiatru
budynki wielostrefowe
Opis:
The paper explains ventilation air exchange driven by the gravitational force and wind, and the major factors affecting the phenomenon. A mathematical model, namely a system of equations, for computations of natural ventilation in two-bay building is presented. The model was used to make calculations of the amount of ventilation air and the pressure inside the building. The effect of external temperature and wind velocity on the amount of ventilation air and pressure values inside the building was analysed. Aerodynamics of multi-zone building ventilation is a complex process. It is difficult to both to determine the pressure prevailing inside the building and to select the area of ventilation openings. The literature does not provide dependences for making computations for such buildings, while computer methods are too time-consuming.
Źródło:
Structure and Environment; 2016, 8, 1; 52-58
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of sand p–y curves by predicting both monopile lateral response and OWT natural frequency
Autorzy:
Amel, Douifi
Djillali, Amar Bouzid
Subhamoy, Bhattacharya
Nasreddine, Amoura
Powiązania:
https://bibliotekanauki.pl/articles/2073761.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
FE analysis
p–y curve
Winkler model
cohesionless soil
monopile
offshore wind turbine
natural frequency
soil–monopile stiffness
Opis:
Extending the use of the p–y curves included in the regulation codes API and DNV to design large-diameter monopiles supporting offshore wind turbines (OWTs) was unsuccessful as it resulted in an inaccurate estimation of the monopile behavior. This had prompted many investigators to propose formulations to enhance the performances of Winkler model. In this paper, two case studies are considered. A case consisting of an OWT at Horns Rev (Denmark) supported by a monopile in a sandy soil was studied first. Taking the FEA using ABAQUS as reference, results of WILDOWER 1.0 (a Winkler computer code) using the recently proposed p–y curves giving design parameters were plotted and evaluated. In order to see the ability of proposed p–y curves to predict the monopile head movements, and consequently the first natural frequency (1st NF), a second case study consisting of a monopile supporting an OWT at North Hoyle (UK) was selected. The monopile head stiffness in terms of lateral, rocking, and cross-coupling stiffness coefficients, necessary for the 1st NF, were computed using both ABAQUS and WILDPOWER 1.0. Comparisons with the measured 1st NF showed that with the exception of one p–y model, none of other proposed Winkler methods is able to predict accurately this parameter.
Źródło:
Studia Geotechnica et Mechanica; 2022, 44, 1; 66--81
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Harmonic analysis of the wind-loaded bar dome at the Satellite Services Centre in Psary
Analiza harmoniczna kopuły prętowej Centrum Usług Satelitarnych w Psarach obciążonej wiatrem
Autorzy:
Szaniec, W.
Zielińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/231008.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
obciążenie wiatrem
analiza harmoniczna
rezonans
drgania własne
drgania wymuszone
wind load
harmonic analysis
resonance
natural vibrations
forced vibrations
Opis:
The research paper presents the results of the dynamic analysis of an existing bar dome subjected to wind loads. The calculation model of the structure was constructed using the finite element method. The dome was subjected to the standard wind pressure, assuming that it is operates in a harmonic manner. The numerical analyses were performed with the application of Autodesk Robot and MES3D. The analysis focused on the impact of selected factors such as the frequency of forcing, wind gustiness coefficient and structural damping on the behaviour of structures.
Kopuły prętowe to obiekty inżynierskie charakteryzujące się dużymi rozmiarami przy stosunkowo niewielkich przekrojach elementów i jednocześnie dużej lekkości całej konstrukcji. Ustroje te, ze wzglądu na swoją małą sztywność, są wrażliwe na działanie czynników atmosferycznych, w szczególności wiatru. Obciążenie to charakteryzuje się dużą zmiennością, jest w znacznym stopniu czynnikiem losowym, co w sposób istotny utrudnia wykonywanie obliczeń. W przypadku projektowania takich obiektów, na podstawie geometrii obiektu, położenia i charakterystyki terenu przyjmuje się obciążenie w postaci parcia wiatru i na tej podstawie wykonuje obliczenia statyczne. W przypadku rozpatrywanych konstrukcji takie podejście nie zawsze wydaje się uzasadnione, niekiedy wskazane jest wykonywanie analiz dynamicznych. Nawet przy niewielkich siłach wymuszających, czasem trudno zauważalnych, istnieje niebezpieczeństwo wystąpienia zjawiska rezonansu, zarówno całej konstrukcji, jak i jej poszczególnych elementów. Obciążenie wiatrem może być przedstawione jako iloczyn statycznego parcia wiatru oraz funkcji zmieniającej tę wartość w czasie. W pracy przyjęto ją w postaci harmonicznej. Ze względu na brak rzeczywistych charakterystyk wiatrowych przyjęto dość szeroki zakres parametrów opisujących to obciążenie (częstość wymuszenia, współczynniki porywistości, prędkość bazowa).
Źródło:
Archives of Civil Engineering; 2016, 62, 1; 37-50
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wiatru na odprowadzanie spalin gazu z mieszkań - studium pewnego przypadku
Effect of wind on evacuation of burned gas from home gas appliances - a case study
Autorzy:
Krajewski, G.
Żurański, J. A.
Powiązania:
https://bibliotekanauki.pl/articles/362629.pdf
Data publikacji:
2010
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
wiatr
odprowadzenie spalin gazu
wentylacja naturalna
zatrucie
obliczenia numeryczne
CFD
wind
drain of combustion gas
natural ventilation
poisoning
numerical calculations
Opis:
Na przykładzie obliczeń numerycznych odprowadzenia spalin gazu z mieszkania w warunkach silnego wiatru przedstawiono wpływ szczególnego ukształtowania dachu na działanie wentulacji naturalnej. Przedstawiono także wpływ zmian w układzie wentylacji mieszkań na odprowadzenie spalin gazu.
The aim of the article is an analysis of natural ventilation system and fumes exhaust from the flat, during the strong wind weather and influence of the roof shape on it. There is shown an influence of some changes in ventilation system inside building, on the way how it works.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2010, T. 5, nr 3, 3; 41-44
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości komplementarnego wykorzystania gazu ziemnego i odnawialnych źródeł energii
The possibility of complementary use of natural gas and renewable energy sources
Autorzy:
Piskowska-Wasiak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1835203.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
odnawialne źródła energii
gaz ziemny
energia wiatrowa
energia słoneczna
komplementarność
synergia
renewables
natural gas
solar power
wind power
complementarity
synergy
Opis:
Przedmiotem artykułu jest określenie możliwości stosowania gazu ziemnego jako nośnika energetycznego, uzupełniającego wykorzystanie odnawialnych źródeł energii. Przedstawiono światowe tendencje w zakresie rozwoju niestabilnych źródeł energii odnawialnej. Omówiono rozwiązania zapewniające komplementarność gazu ziemnego z odnawialnymi źródłami energii i uwarunkowania współpracy systemów elektroenergetycznego oraz gazowego. Poddano analizie perspektywy wdrożenia komplementarnych technologii wykorzystujących gaz ziemny i OZE w Polsce w aspekcie obowiązujących, a także prawdopodobnych przyszłych regulacji prawnych.
The subject of the article is to present the possibility of using natural gas as an energy carrier supplementing the use of renewable energy sources. The world trends in the development of unstable renewable energy sources are presented. Solutions to ensure the complementarity of natural gas with renewables and conditions for the cooperation of the electricity and gas systems are discussed. An analysis was made of the prospects for the implementation of complementary technologies using natural gas and RES in Poland in terms of present and probable future legal regulations.
Źródło:
Nafta-Gaz; 2018, 74, 4; 290-297
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lekcje dla Polski z niemieckiej transformacji energetycznej „Energiewende”
Lessons for Poland from German energy transition “Energiewende”
Autorzy:
Strupczewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2055812.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
finansowanie transformacji energetycznej
transformacja energetyczna w Niemczech
Energiewende
energia wiatrowa
odnawialne źródła energii
cisza wiatrowa
wiatraki prądotwórcze
środowisko naturalne
financing energy transformation
energy transformation in Germany
wind energy
renewable energy sources
wind quiet zone
windmills generators
natural environment
Opis:
Ogromne koszty finansowania niemieckiej transformacji energetycznej “Energiewende” w 2020 r. przekroczyły nawet oczekiwania zwolenników energetyki wiatrowej i słonecznej, osiągając ponad 30 mld euro rocznie. Ale energetyka wiatrowa nie może zapewnić ciągłości zasilania elektrycznego. Wykresy w artykule pokazują okresy ciszy wiatrowej na lądzie i na morzu, sięgające 120 godzin w morskich farmach wiatrowych i 170 godzin w wiatrakach na lądzie. Dlatego Niemcy muszą uzupełniać produkcję energii elektrycznej, spalając węgiel brunatny i importowany gaz. Nie jest to droga do ochrony środowiska. Wiatraki mają negatywny wpływ na zdrowie ludzi i na środowisko, powodując setki tysięcy zgonów ptaków, nietoperzy i owadów. Strategię Energiewende ostro krytykują niemieccy eksperci energetyczni, zarówno z uczelni technicznych, jak i z przemysłu.
The extreme costs of German energy transition “Energiewende” in 2020 exceeded even the expectations of advocates of renewable energy sources and reached above 30 billion euro per year. However, the wind cannot assure continuity of electric power supply. The graphs in the paper show the periods of wind lulls on the land and on the sea reaching into 120 hours at offshore wind mills or 170 hours on land. Thus Germany has to provide electric energy by burning lignite and imported gas. This is no way for environment protection. The wind mills have a negative impact on human health and environment, causing hundreds of thousands kills of birds, bats and insects. The strategy of Energiewende is sharply criticised by German energy experts, both from technical universities and from the industry.
Źródło:
Postępy Techniki Jądrowej; 2021, 1; 23--28
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oddziaływanie wiatru na przepływ powietrza w tunelach drogowych wentylowanych naturalnie w warunkach pożaru
Wind influence on the flow inside the road tunnels in the case of the fire
Autorzy:
Sztarbała, G.
Powiązania:
https://bibliotekanauki.pl/articles/391161.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
wentylacja naturalna tuneli
tunel drogowy
oddziaływanie wiatru
komputerowa mechanika płynów
pożar w tunelu
natural ventilation in tunnel
road tunnel
wind action on tunnel
physical modelling
Opis:
W niniejszej pracy przedstawiono wyniki obliczeń numerycznych rozprzestrzeniania się dymu i ciepła w odniesieniu do niezagłębionych, krótkich tuneli drogowych o przekroju prostokątnym wentylowanych naturalnie. Obliczenia numeryczne przeprowadzono w sposób pozwalający na jednoczesne uwzględnienie oddziaływania wiatru i warunków pożaru. Struktura oddziaływującego na tunel wiatru została opisana profilem logarytmicznym, zaś pożar za pomocą modelu objętościowego. Rozważana w pracy prędkość wiatru zawierała się w zakresie od 2,0 m/s do 6,0 m/s, zaś przyjęte moce pożaru odnosiły się odpowiednio do pożaru jednego samochodu osobowego, jednego samochodu typu „van” oraz jednego autobusu. Wyniki przeprowadzonych badań wykazały, że zjawisko stratyfikacji dymu w tunelach wentylowanych naturalnie występuje tylko w warunkach bezwietrznych a system wentylacji naturalnie nie jest w stanie zapewnić wymaganego poziomu bezpieczeństwa pożarowego.
An important factor in ensuring the fire safety of a construction works, such as a tunnel, is the effective evacuation of smoke and heat to allow people to evacuate and enable to fight a fire. In short tunnels natural ventilation is used, where the flow of air is caused by natural convection phenomena and weather conditions. The results of this research show that the stratification phenomenon in naturally ventilated tunnels occurs in windless conditions only. Flow blockage was observed for a wind angle equal to 90°, causing smoke and heat to remain in the tunnel. The use of natural ventilation to remove smoke and heat from short tunnels is inappropriate due to the ineffective functioning, in the case of the fire and wind action.
Źródło:
Budownictwo i Architektura; 2013, 12, 2; 157-164
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic response of the Stuttgart TV Tower measured by classical instruments and GPS technology
Pomiary odpowiedzi dynamicznej wieży telewizyjnej w Stuttgarcie za pomocą klasycznych przyrządów pomiarowych i technologią GPS
Autorzy:
Breuer, Peter
Chmielewski, Tadeusz
Górski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1853630.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wieża telewizyjna
Stuttgart
pomiar GPS
odpowiedź dynamiczna
odpowiedź spowodowana wiatrem
częstotliwości drgań własnych
liczba tłumienia drgań
television tower
GPS measurement
wind-induced response
dynamic response
natural frequency
damping ratio
Opis:
This paper compares the measurement results of dynamic characteristics, including natural frequencies, damping ratio, and wind-induced responses of the Stuttgart TV Tower (TV Tower), obtained by Lenk in 1959 using classical instruments with those obtained by the authors a few decades later using Global Positioning System (GPS). The objective of this paper was to monitor the response of the TV Tower under wind loading, which is an important tool for the validation of its design, construction, and structural health. During the authors’ GPS measurements, weak and moderate wind speeds occurred most of the time. Only in 2007, the stronger wind observed (90 < V < 100 km/h) at the head of the TV Tower (H=157 m), which caused displacements in the decimetre range. Further measurements in 2011 were carried out, using additional GPS receivers with a higher data rate. The results achieved by the GPS prove that the cross-wind response was larger than the along-wind component for all ranges of wind speed, which occurred during the measurement periods, i.e. from 2002 to 2015. The authors of this paper extended Lenk’s results, by the static and along-wind components, confirmed the first natural frequency, and damping ratio, evaluated by the Random Decrement technique. Mounting a GPS receiver, on the steel antenna mast tip, enabled detection of the second natural frequency fs2 = 0.800 Hz, which is the frequency of the mode shape of the TV Tower steel antenna mast. Lenk did not measure this frequency.
Wieża telewizyjna w Stuttgarcie została oddana do użytkowania w dniu 5 lutego 1956 roku. Konstrukcja wieży składa się z dwóch części: (a) trzonu żelbetowego z głowicą o wysokości 161 m i (b) stalowego masztu antenowego o wysokości 56 m. Całkowita wysokość wieży to 217 m. Średnica zewnętrzna trzonu żelbetonowego wynosi 10,8 m u podstawy trzonu i 5,04 m w górnej części trzonu (poniżej głowicy trzonu). Grubość ściany trzonu zmienia się od 60 cm do 19 cm. W latach 1953-1954 Leonhard zaproponował koncepcję i projekt wieży telewizyjnej. Biuro projektowe Pieckert zaprojektowało system konstrukcyjny. Koncepcję wieży telewizyjnej, jej układ konstrukcyjny, wszystkie założenia do obliczeń statycznych, oszacowanie nakładów finansowych i pierwsze pomiary osiadań fundamentów podane zostały w jednej z prac Leonhardta. W tej pracy zasugerowano także potrzebę pomiaru odpowiedzi wieży telewizyjnej na działanie wiatru. Jako pierwszy dokonał tego Lenk w 1959 roku. W latach 1977 i 1995 stwierdzono pionowe pęknięcia w żelbetowym trzonie wieży, które następnie zostały naprawione. Przyczyny tych pęknięć wyjaśniono jako konsekwencje promieniowania słonecznego i dobowych zmian temperatury powietrza działających na trzon wieży telewizyjnej, wywołujących deformacje płaszcza trzonu. Naprężenia termiczne spowodowały zmienną w czasie „owalizację” trzonu wieży, która z biegiem lat doprowadziła do zmęczenia materiału, czego skutkiem były wyraźnie widoczne podłużne pęknięcia po przeciwnych stronach trzonu wieży telewizyjnej. Autorom niniejszego artykułu nie są znane wcześniejsze pomiary charakterystyk dynamicznych wieży telewizyjnej związane z naprawą powstałych pęknięć. W związku z tym, w 1999 roku autorzy przeprowadzili pierwszą serię pomiarów przemieszczeń wierzchołka wieży telewizyjnej z zastosowaniem techniki satelitarnej GPS. Metodologia pomiarów była podobna do metodologii stosowanej przez innych badaczy. Na tej podstawie autorzy potwierdzili możliwość zastosowania systemu GPS do monitorowania przemieszczeń statycznych, quasi-statycznych i dynamicznych oraz do określania podstawowych charakterystyk dynamicznych (częstotliwości drgań własnych i współczynników tłumienia drgań) istniejących dużych konstrukcji w skali naturalnej. Autorzy cyklicznie monitorowali przedmiotową wieżę telewizyjną do roku 2015. Jednak pomimo podjętego wysiłku w celu zebrania dodatkowych danych pomiarowych, niestety w 2013 i 2015 r. nie było możliwości pomiaru przemieszczeń wieży telewizyjnej pod wpływem silnego wiatru. Niemniej jednak autorzy dokonali analizy danych pomiarowych zgromadzonych w latach 2002, 2005, 2006, 2007, 2008 i 2011, które obejmowały pomiary w zakresie prędkości wiatru od małej do dużej. W dniach 18-19 stycznia 2007 r. w pobliżu wieży zarejestrowano porywy wiatru o prędkości 26 m/s, co spowodowało jej przemieszczenia w zakresie decymetrów.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 7-38
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększenie wydajności wentylacji naturalnej poprzez stosowanie nasady kominowej
Reasons for discussing the efficiency of natural ventilation using the cowl
Autorzy:
Antczak-Jarząbska, R.
Niedostatkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/162269.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
wentylacja naturalna
efektywność
czynnik wpływu
nasada kominowa
warunki pogodowe
temperatura powietrza
szybkość wiatru
badanie eksperymentalne
natural ventilation
effectiveness
influence factor
chimney pot
weather conditions
air temperature
wind velocity
experimental investigation
Opis:
Wentylacja naturalna (grawitacyjna) jest najbardziej popularną metodą wentylowania pomieszczeń mieszkalnych w Polsce. Ten rodzaj wentylacji działa pod wpływem sił natury, w związku z tym trudno jest ją kontrolować i przewidywać. Wentylacja naturalna działa najlepiej zimą oraz w wietrzne dni, gdy prędkość wiatru Vw przekracza 3 m/s. Najgorszy pod względem wydajności wentylacji naturalnej jest okres przejściowy wiosenno-jesienny. W celu poprawy wydajności wentylacji naturalnej stosuje się między innymi nasady kominowe. Mają one za zadanie poprawić efekt kominowy określany w języku potocznym jako ciąg kominowy. Efekt kominowy jest to zjawisko fizyczne powstawania spontanicznego przepływu cieplejszego gazu, np. powietrza, z dołu do góry w kanałach trzonów. W artykule przeprowadzono analizę wpływu nasady kominowej na poprawę efektu kominowego w eksploatowanym mieszkaniu budynku wielorodzinnego z wentylacją naturalną. Długoterminowe badania ciągu kominowego wykonano dla przypadku bez nasady i z nasadą kominową.
Natural (gravity) ventilation is the most popular method of ventilation of living spaces in Poland. This type of ventilation works under the influence of natural forces, so it is difficult to control or to predict. Natural ventilation works best in winter and windy days when the wind speed exceeds 3 m/s. Spring and autumn transition period is the worst possible time for natural ventilation. In order to improve the efficiency of natural ventilation, the chimney cowls are used. They are designed to improve the chimney effect, which – in colloquial language – is defined as chimney draught. The chimney effect is a physical phenomenon of the spontaneous formation of a warmer gas, e.g. air, from the bottom up in the shafts. The paper discusses the impact of cowl on the improvement of the chimney effect in the multi-family house with natural ventilation. Long-term tests of the chimney draught were made in both cases: with and without the cowl.
Źródło:
Przegląd Budowlany; 2017, 88, 12; 32-36
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Państwa nieuznawane w badaniach analityczno-prognostycznych rynku paliwowo-energetycznego Południowego Kaukazu. Zaopatrzenie energetyczne Osetii Pd. i Abchazji vs. Republiki Górskiego Karabachu
Unrecognized Countries in the Analytical and Prognostic Research of the South Caucasus Fuel and Energy Market. Energy Supply of Ossetia South and Abkhazia vs. The Republic of Nagorno-Karabakh
Autorzy:
Kwiatkiewicz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/31339481.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
crude oil
natural gas
electricity
power plants
hydroelectricity
wind power
South Caucasus
Armenia
Georgia
Azerbaijan
South Ossetia
Abkhazia
the Nagorno-Karabakh Republic
ropa naftowa
gaz ziemny
energetyka
elektrownie
hydroenergetyka
energetyka wiatrowa
Kaukaz Pd.
Osetia Pd.
Abchazja
Republika Górskiego Karabachu
Opis:
Kaukaz Południowy i badania nad jego gospodarką niosą za sobą trudności wynikające ze specyfiki politycznej tego regionu. Konflikt zbrojny między Armenią i Azerbejdżanem, ograniczone relacje z otoczeniem zewnętrznym – Armenia–Turcja, Gruzja–Rosja; nie sprzyjają wymianie handlowej i transparentności zawieranych transakcji. Wyzwanie dla poszukiwań naukowych stanowi istnienie tzw. państw nieuznawanych. Nie sposób określić precyzyjnie wielkości konsumpcji paliwowej czy zużycia energii elektrycznej, gdyż nie są zaopatrywane energetycznie przez państwa, w których granicach de jure są położone. Ich legalna przynależność nie pozwala by były pomijane we wszelkiego typu zestawach, co rzutuje na wyniki końcowe poszukiwań analityczno-prognostycznych w obszarze energetyki, które są zależne od jakości przekazywanych danych oraz trafności prognoz rozwoju gospodarczego. Omawiane przykłady Abchazji i Osetii Pd. oraz Republiki Górskiego Karabachu są tego dowodem. Zestawienie tych dwóch przypadków pozwala wyeksponować różnice między nimi.
The Southern Caucasus and its economic research entails difficulties due to the political uniqueness of the region. Armed conflicts between Armenia and Azerbaijan and limited relations with the external environment of Armenia–Turkey and Georgia–Russia do not favor trade and transparency of concluded transactions. The existence of the so-called unrecognized countries poses a challenge to scientific research. It is impossible to determine precisely the amount of fuel consumption or electricity consumption, because they are not supplied by the countries within which they are located. Their legal affiliation does not allow them to be omitted in all types of sets, which affects the final results of analytical and prognostic research in the field of energy, which depend on the quality of data and economic development forecasts accuracy. The examples of Abkhazia, South Ossetia, and the Republic of Nagorno- Karabakh are proof of this. The combination of these two cases makes it possible to highlight the differences between them, which result from a different approach to the issue of meeting the energy needs of the local population by their home countries.
Źródło:
Środkowoeuropejskie Studia Polityczne; 2022, 4; 155-168
1731-7517
Pojawia się w:
Środkowoeuropejskie Studia Polityczne
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-21 z 21

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies