Continuation of Prof. Władysław Latek’s research – revitalization of old power units
Autorzy:
Krok, R.
Pasko, M.
Powiązania:
https://bibliotekanauki.pl/articles/200213.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
turbogenerator design
modernization of power units
increase of installed power
turbogenerator
modernizacja bloków energetycznych
wzrost mocy zainstalowanej
Opis:
The research conducted by Prof. Władysław Latek (1916‒1991) has contributed greatly to development in turbogenerator design. The economical transformation taking place in Poland after 1991 initiated the process of revitalization of old power units in electric power stations. For the past 25 years, a team of scientists continuing the work on perfecting the turbogenerator design and design methods has been working in the Faculty of Electrical Engineering of Silesian University of Technology. The work of this team has led to proposing and implementing many modernization projects for turbogenerators operating in Polish power plants, as well as in power plants in European Union and Asian states. Numerous novel and innovative solutions have made it possible to significantly increase turbogenerator power, improve effectiveness of electrical energy production and reliability and safety of operation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 4; 957-962
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja i rewitalizacja istniejących bloków węglowych ważnym warunkiem stabilności sektora wytwarzania elektryczności
The modernization and revitalization of existing coal – fired plants are an important requirement for the stability of the electricity generation sector
Autorzy:
Chmielniak, T.
Rusin, A.
Łukowicz, H.
Powiązania:
https://bibliotekanauki.pl/articles/283390.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
bloki węglowe
modernizacja bloków
bezpieczeństwo systemu energetycznego
coal-fired unit
modernization of power units
security of energy system
Opis:
Polskie technologie wytwarzania elektryczności wykorzystują głównie paliwa kopalne. Mimo istotnego wzrostu zainstalowanej mocy ze źródeł odnawialnych, stanowi ona nadal ponad 90% całego wolumenu wytwarzanej elektryczności. Drugą istotną charakterystyką infrastruktury wytwarzania jest zaawansowany wiek przeważającej liczby bloków (zwłaszcza bloków 200 MW). W stadium realizacji są obecnie cztery bloki na węgiel kamienny o mocy rzędu 1000 MW, jedna jednostka 500 MW na węgiel brunatny jest planowana. Rachunek ekonomiczny pokazuje, że dla tych bloków inwestycja ma swe uzasadnienie przy cenie elektryczności 240 270 zł/MWh. Obserwacja cen hurtowych wskazuje natomiast, że są one istotnie niższe, z ciągłą tendencją do spadku, (rys. 4) (www.ure.gov.pl). Rodzi to wątpliwości co do zasadności – z ekonomicznego punktu widzenia przy obecnych cenach węgla – wprowadzania do systemu nowych bloków dużej mocy. W konsekwencji wskazano na celowość poszukiwań innych rozwiązań pomostowych. Jednym z nich jest przedłużenie eksploatacji istniejącej infrastruktury bloków 200 MW. W artykule przedstawiono przesłanki do podjęcia programu modernizacji i rewitalizacji bloków klasy 200 MW celem przedłużenia ich eksploatacji do 2035–2040 r. Wskazano na podstawowe problemy konieczne do rozwiązania dla spełnienia przez nie odpowiednich kryteriów ekologicznych (w tym konkluzji BAT) i technologicznych (głównie dotyczących zwiększenia elastyczności cieplnej). Naszkicowano zakres badań naukowych i przemysłowych.
Polish power technologies mainly use fossil fuels. Despite a significant increase in the installed capacity from renewable sources, it still makes up more than 90% of the total volume of the electricity produced. Another important characteristic of the generation infrastructure is the advanced age of the majority of the blocks (especially 200 MW). At the stage of implementation are currently four coal-fired blocks with a capacity of approximately 1000 MW. Morever one lignite unit of 500 MW is planned. Economic calculations show that the investment for these blocks is justified by the price of electricity PLN 240–270 / MWh. The observation of the wholesale price indicates, however, that they are significantly lower, with the continuous trend of decline (fig. 4). This means that the introduction of new blocks of high-power to the system at the current price of coal is rather unjustified. Consequently, it pointed to the desirability of other technological solutions. One of them is the extension of the operation of the existing infrastructure by 200 MW. The article presents evidence to undertake a program of modernization and revitalization of the 200 MW class units for the extension of their use to 2035–2040. The fundamental problems needed to be resolved for the fulfilment of appropriate environmental criteria (including BAT conclusions) and technological ones (mainly increase the flexibility of the heat) have been specified. The paper also outlined the scope of scientific research and industrial applications.
Źródło:
Polityka Energetyczna; 2016, 19, 3; 49-60
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe uzwojenie stojana turbogeneratora przeznaczonego do pracy elastycznej
New stator winding of turbogenerator dedicated to elastic operation
Autorzy:
Krok, Roman
Powiązania:
https://bibliotekanauki.pl/articles/268943.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rewitalizacja bloków energetycznych
elastyczna praca bloku
modernizacja turbogeneratorów
revitalization of power units
elastic operation of power unit
turbogenerator modernization
Opis:
W artykule przedstawiono nowe uzwojenie stojana turbogeneratora o mocy 200 MW umożliwiające elastyczną pracę bloku po podwyższeniu mocy. Wykonane obliczenia oraz pomiary nagrzewania turbogeneratora zmodernizowanego i fabrycznego wykazały bardzo duże obniżenie temperatury nowego uzwojenia stojana w porównaniu do fabrycznego pomimo znacznego podwyższenia mocy turbogeneratora z 200 do 240 MW. Bardzo niska temperatura uzwojenia stojana oraz wykonanie wszystkich przewodów elementarnych pełnych i drążonych z jednego materiału (miedzi) zapewnia bezawaryjną pracę zmodernizowanego turbogeneratora przy pracy elastycznej. Innowacyjne rozwiązanie prętów uzwojenia stojana wykorzystano przy modernizacjach turbogeneratorów związanych z realizacją programu dla polskiej energetyki „Bloki 200+”.
A proposal for changing the construction of turbogenerator stator winding is set forth in the paper. This is a winding of turbogenerator rated at 200 MW and proposed modernization should ensure elastic operation of the power unit and, at the same time, significant increase of power. This proposed design leads to reduction of power losses in stator winding bars (in relation to the original winding). In order to achieve a significant decrease of stator winding temperature it is additionally proposed to use new rotor fans (with improved efficiency) to enhance cooling of turbogenerator stator core. The conducted calculations and thermal (heating) measurements of original and modernized turbogenerators show a significant decrease of new stator winding temperature in relation to the original winding, even though turbogenerator’s power has been raised from 200 to 240 MW (power factor has been maintained at its nominal value). The innovative design of stator winding bars and rotor fans was used in modernizing Polish turbogenerators in the framework of the Polish power industry programme „Bloki 200+” („200+ power units”). New stator winding and fans have also been assembled into many turbogenerators operating not only in Poland, but in EU countries as well. Experimental verification of modernized turbogenerators operating in power plants and long-term periods of reliable, failure-free operation fully confirm the correctness of design assumptions.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 163-166
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies