Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "modelowanie dyspersji atmosferycznej" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Ocena modelu dyspersji zanieczyszczeń powietrza OSPM: studium przypadku, Polska, Kraków
Evaluation of the OSPM Air Pollutants Dispersion Model: Case Study, Krakow, Poland
Autorzy:
Rzeszutek, M.
Bogacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818043.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ocena modelu
OSPM
modelowanie dyspersji atmosferycznej
kanion uliczny
zanieczyszczenie powietrza
evaluation of model
modeling of atmospheric dispersion
street canyon
air pollution
Opis:
The study represents the evaluation of the OSPM model on the basis of the simulation results carried out for the street canyon located in the Zygmunt Krasinski alley in Krakow. Road emission was estimated based on the data from 2012 in regard to the traffic volume and the types of vehicles. Meteorological data were acquired from the station located in the vicinity of the examined canyon. Ambient air quality was determined based on the monitoring data from the urban background station in Krakow. The calculation results were compared with the 1-hour concentration measurements from the traffic station located on the green belt between the two lanes of the analysed canyon. The analysis was restricted to the nitrogen dioxide (NO2) and the PM10 and PM2.5 particulate matter concentrations. Model evaluation was carried out according to the methodology of the air quality models assessment. Values of OSPM model statistical evaluation parameters fall within the range of “good models”, which indicates a very good quality of this model calculation results. A very strong correlation between the results of calculations and the observations was found, particularly for the particulate matter PM10 and PM2.5. Correlation coefficient values for these pollutants are 0.90 and 0.91, respectively. A detailed analysis revealed that the overall quality of the model is better with respect to nitrogen dioxide than for the analysed dust pollutants. However, this model is burdened with a tendency to underestimate 1-hour concentrations of particulate matter, which can be associated with: negligence of the lifting effect of the dust deposited on the road surface, the effect of removing the particulate filters from vehicles and the adequate ambient air quality for the analysed monitoring site. Very good agreement of the simulation results and observations indicates that the OSPM modelling system can be successfully applied to support the air quality management system in Krakow.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 351-362
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie systemu modeli CALMET/CALPUFF o wysokiej rozdzielczości do oceny wpływu na jakość powietrza spalarni odpadów komunalnych w Krakowie
Use of the high resolution system of CALMET/CALPUFF models to air quality impact assessment for the municipal solid waste incineration plant in Krakow
Autorzy:
Rzeszutek, M.
Oleniacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/297199.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
spalanie odpadów
ZTPOK
zanieczyszczenie powietrza
ocena oddziaływania
modelowanie dyspersji atmosferycznej
CALMET
CALPUFF
waste incineration
MSWI plant
air pollution
impact assessment
atmospheric dispersion modeling
Opis:
W pracy przedstawiono kompleksową ocenę wpływu na jakość powietrza planowanego do uruchomienia pod koniec 2015 roku Zakładu Termicznego Przekształcania Odpadów Komunalnych (ZTPOK) w Krakowie, którego budowa ruszyła jesienią 2013 r. Modelowanie rozprzestrzeniania się zanieczyszczeń w powietrzu atmosferycznym przeprowadzono przy wykorzystaniu zaawansowanego wielowarstwowego gaussowskiego modelu obłoku CALPUFF, którego algorytmy uwzględniają m.in. zróżnicowanie ukształtowania terenu. Dane przestrzenne powierzchni terenu w przyjętej domenie obliczeniowej pozyskano z numerycznego modelu terenu Shuttle Radar Topography Mission (SRTM3) oraz bazy danych pokrycia terenu CORINE Land Cover 2006 (CLC 2006) o rozdzielczości około 100 m. Warunki meteorologiczne wyznaczono za pomocą diagnostycznego modelu meteorologicznego CALMET na podstawie danych meteorologicznych, pochodzących ze stacji naziemnych oraz sondaży radarowych. Wyniki obliczeń wykonanych w siatce o bardzo dużej gęstości wskazują, że emisja zanieczyszczeń z ZTPOK w Krakowie, przyjęta na maksymalnym dopuszczalnym poziomie, nie przyczyni się do istotnego pogorszenia jakości powietrza w Aglomeracji Krakowskiej i sąsiednich gminach.
In this paper there was presented a comprehensive assessment of the impact on air for the Municipal Solid Waste Incineration (MSWI) plant in Krakow with the planned start of operation by the end of 2015. Construction of the plant started in autumn 2013 in the district of Nowa Huta in Krakow. Modeling of the spread of pollutants in ambient air was conducted using an advanced multi-layer cloud CALPUFF Gaussian model, whose algorithms include, among other things, diversity of terrain. Spatial data of land area in the admitted computational domain are obtained from digital terrain model Shuttle Radar Topography Mission (SRTM3) and land cover database CORINE Land Cover 2006 (CLC 2006) with resolution of about 100 m. Meteorological conditions were determined using a diagnostic meteorological model CALMET based on meteorological data from subsurface stations and radar surveys. Spatial variability of the hourly, daily and annual averages of air pollutant concentrations was obtained in computing grid with very high density. The results of calculations indicate that pollutant emissions from MSWI plant in Krakow adopted at the maximum allowable level will not cause exceedances of acceptable levels or reference values in the air and will not also contribute to a significant deterioration of air quality in the Agglomeration of Krakow and neighboring municipalities.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 1; 5-22
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of chemical transformation modules for secondary inorganic aerosol formation in CALPUFF model
Ocena modułów przemian chemicznych tworzenia się wtórnych aerozoli nieorganicznych w modelu CALPUFF
Autorzy:
Oleniacz, R.
Rzeszutek, M.
Bogacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/126846.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
air pollution
chemical transformations
secondary inorganic aerosols
atmospheric dispersion modeling
CALPUFF
ISORROPIA
RIVAD
MESOPUFF
zanieczyszczenie powietrza
przemiany chemiczne
wtórne aerozole nieorganiczne
modelowanie dyspersji atmosferycznej
Opis:
Air quality impact assessment is usually carried out with the application of simplified stationary dispersion models, which omit the chemical transformation process of air pollutants. Omission of this effect in the calculation process increases the uncertainty of the obtained results, and hinders the decision making process, related to air quality management. The paper presents a comparison of atmospheric dispersion modeling related to pollutants emitted from high industrial emitters, performed with and without consideration of various chemical transformation modules pertaining to the formation of inorganic aerosols, available in the CALMET/CALPUFF modeling system. A mechanism of inorganic aerosol formation in a liquid phase, considered in the ISORROPIA/RIVAD+AQUA module was observed to exert strong influence on calculation results referring to concentration levels of some air contaminants. The following was found out: more than a double decrease of the annual average concentration of SO2, and even more significant increase (from 7 to 10 times) of the annual average concentration of PM10 (as a sum of primary and secondary particles) in comparison to other considered chemical transformation modules (MESOPUFF, RIVAD/ARM3, ISORROPIA/RIVAD), and a variant with a chemical transformation module switched off (without taking into account the secondary inorganic aerosol formation).
Ocena wpływu źródeł emisji na jakość powietrza wykonywana jest zwykle przy użyciu uproszczonych stacjonarnych modeli dyspersji, pomijających procesy przemian chemicznych zanieczyszczeń powietrza. Pominięcie tych efektów w procesie obliczeniowym powoduje zwiększenie niepewności uzyskanych wyników oraz utrudnia proces podejmowania prawidłowych decyzji związanych z zarządzaniem jakością powietrza. Praca przedstawia porównanie wyników modelowania dyspersji atmosferycznej zanieczyszczeń emitowanych z wysokich emitorów przemysłowych prowadzonych bez uwzględniania i z uwzględnianiem różnych modułów przemian chemicznych tworzenia się nieorganicznych aerozoli, dostępnych w systemie modelowania CALMET/CALPUFF. Wykazano istotny wpływ mechanizmu tworzenia się wtórnego aerozolu nieorganicznego w fazie wodnej, uwzględnianego w module ISORROPIA/RIVAD+AQUA, na wyniki obliczeń poziomów stężeń niektórych zanieczyszczeń w powietrzu. Stwierdzono m.in. ponad 2-krotny spadek średniego poziomu stężeń średniorocznych SO2 i jeszcze większy (od 7 do 10 razy) wzrost średnich wartości stężeń średniorocznych pyłu PM10 (suma cząstek pierwotnych i wtórnych) w porównaniu z innymi rozpatrywanymi modułami przemian chemicznych (MESOPUFF, RIVAD/ARM3, ISORROPIA/RIVAD) oraz wariantem z wyłączonym modułem przemian chemicznych (bez uwzględniania tworzenia się wtórnego aerozolu nieorganicznego).
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 57-66
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies