Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model wastewater" wg kryterium: Temat


Tytuł:
Kinetic Model of Wastewater Treatment in Horizontal Flow Flotation Tank
Autorzy:
Antonova, Ekaterina Sergeevna
Sazonov, Dmitry Vasil'evich
Powiązania:
https://bibliotekanauki.pl/articles/123615.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
flotation
mathematical model
wastewater treatment
horizontal flotation tank
Opis:
The flotation wastewater treatment was considered in the paper. The main stages and parameters of flotation process were pointed out. The multistage flotation model considering all main stages of flotation process is presented. However, its main disadvantage is that for the definition of constant characterizing the bubble-particle aggregate formation, the constant value of superficial gas velocity was used, which is incorrect for horizontal flow flotation tank. The modified multistage flotation model with superficial gas velocity as the function of time was proposed. The experiments were carried out on a laboratory setup with a pneumohydraulic system of aeration in order to verify the proposed model. The comparison of experimental and theoretical results proved the importance of superficial gas velocity change consideration.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 190-196
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of quantitative and qualitative wastewater monitoring in water protection on the example of Lodz
Autorzy:
Brzezińska, Agnieszka
Sakson, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/105317.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
sewer system
wastewater monitoring
rainfall monitoring
predictive model
system ściekowy
monitoring ścieków
monitoring opadów
model predykcyjny
Opis:
Widely understood protection of water, and in particular surface waters, most exposed to direct pollution, requires many operations carried out both in the catchment area and in sewage systems as well as wastewater treatment plants. Due to its character and working conditions, it should be monitored not only in terms of hydraulics, but also in terms of the quality of transported wastewater. During atmospheric precipitation, large volumes of domestic and industrial wastewater as well as rainwater in various proportions flow through the canals, changing not only their quantity but also their composition. In such cases, the issue of monitoring becomes particularly vital. The article presents an analysis of the needs and tasks resulting from the application of quantitative and qualitative monitoring in the assessment of the functioning of sewage systems. Methods and tools used in Lodz that may be useful in water protection are presented. The benefits of using this type of solutions as well as the limitations and difficulties are discussed.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2019, 66, 2; 21-34
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of Quantitative and Qualitative Wastewater Monitoring in Water Protection on the Example of Lodz
Stosowanie ilościowego i jakościowego monitorowania ścieków w ochronie wód na przykładzie Łodzi
Autorzy:
Brzezińska, Agnieszka
Sakson, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1811582.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
sewer system
wastewater monitoring
rainfall monitoring
predictive model
system kanalizacyjny
monitoring ścieków
monitoring opadów
model predykcyjny
Opis:
Widely understood protection of water, and in particular surface waters, most exposed to direct pollution, requires many operations carried out both in the catchment area and in sewage systems as well as WWTPs. Due to its character and working conditions, it should be monitored not only in terms of hydraulics, but also in terms of the quality of transported wastewater. During atmospheric precipitation, large volumes of domestic and industrial wastewater as well as rainwater in various proportions flow through the canals, changing not only their quantity but also their composition. In such cases, the issue of monitoring becomes particularly vital. The article presents an analysis of the needs and tasks resulting from the application of quantitative and qualitative monitoring in the assessment of the functioning of sewage systems. Methods and tools used in Lodz that may be useful in water protection are presented. The benefits of using this type of solutions as well as the limitations and difficulties are discussed.
Szeroko rozumiana ochrona wód, a zwłaszcza wód powierzchniowych, najbardziej narażonych na bezpośrednie zanieczyszczenie, wymaga wielu działań przeprowadzanych zarówno w zlewni, jak i w systemach kanalizacyjnych oraz w oczyszczalniach ścieków. Ze względu na swój charakter i warunki pracy system kanalizacji należy monitorować nie tylko pod względem hydraulicznym, ale także pod względem składu transportowanych ścieków. Podczas opadów atmosferycznych przez kanały, w różnych proporcjach, przepływają znaczne ilości ścieków bytowych, przemysłowych oraz deszczowych, zmieniając przy tym także swój skład. W takich przypadkach kwestia monitorowania staje się szczególnie istotna. W artykule przedstawiono analizę potrzeb i zadań wynikających z zastosowania monitorowania ilościowego i jakościowego w ocenie funkcjonowania systemów kanalizacyjnych oraz metody i narzędzia stosowane w Łodzi, które mogą być przydatne w ochronie wód. Omówiono zalety korzystania z tego typu rozwiązań, a także ograniczenia i trudności.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 1; 431-443
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear stabilizing control of an uncertain bioprocess model
Autorzy:
Dimitrova, N.
Krastanov, M.
Powiązania:
https://bibliotekanauki.pl/articles/930090.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
stabilność asymptotyczna
sterowanie nieliniowe
wastewater treatment model
local bifurcations of steady states
asymptotic stabilization
extremum seeking
uncertain data
Opis:
In this paper we consider a nonlinear model of a biological wastewater treatment process, based on two microbial populations and two substrates. The model, described by a four-dimensional dynamic system, is known to be practically verified and reliable. First we study the equilibrium points of the open-loop system, their stability and local bifurcations with respect to the control variable. Further we propose a feedback control law for asymptotic stabilization of the closed-loop system towards a previously chosen operating point. A numerical extremum seeking algorithm is designed to stabilize the dynamics towards the maximum methane output flow rate in the presence of coefficient uncertainties. Computer simulations in Maple are reported to illustrate the theoretical results.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2009, 19, 3; 441-454
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic modelling of an anaerobic reactor treating coffee wet wastewater via multiple regression model
Autorzy:
Guardia-Puebla, Yans
Llanes-Cedeño, Edilberto
Domínguez-León, Ana Velia
Arias-Cedeño, Quirino
Sánchez-Girón, Victor
Morscheck, Gert
Eichler-Löbermann, Bettina
Powiązania:
https://bibliotekanauki.pl/articles/1841946.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
coffee wet wastewater
modelling
multiple regression model
upflow anaerobic sludge blanket
UASB
Opis:
A multiple regression model approach was developed to estimate buffering indices, as well as biogas and methane productions in an upflow anaerobic sludge blanket (UASB) reactor treating coffee wet wastewater. Five input variables measured (pH, alkalinity, outlet VFA concentration, and total and soluble COD removal) were selected to develop the best models to identify their importance on methanation. Optimal regression models were selected based on four statistical performance criteria, viz. Mallow’s Cp statistic (Cp), Akaike information criterion (AIC), Hannan–Quinn criterion (HQC), and Schwarz–Bayesian information criterion (SBIC). The performance of the models selected were assessed through several descriptive statistics such as measure of goodness-of-fit test (coefficient of multiple determination, R2; adjusted coefficient of multiple determination, Adj-R2; standard error of estimation, SEE; and Durbin–Watson statistic, DWS), and statistics on the prediction errors (mean squared error, MSE; mean absolute error, MAE; mean absolute percentage error, MAPE; mean error, ME and mean percentage error, MPE). The estimated model reveals that buffering indices are strongly influenced by three variables (volatile fatty acids (VFA) concentration, soluble COD removal, and alkalinity); while, pH, VFA concentration and total COD removal were the most significant independent variables in biogas and methane production. The developed equation models obtained in this study, could be a powerful tool to predict the functionability and stability for the UASB system.
Źródło:
Journal of Water and Land Development; 2021, 50; 229-239
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba zwiększenia skuteczności usuwania fosforu w modelu oczyszczalni ścieków
Experiment of increasing effectiveness of phosphorus removal in a model of wastewater treatment plant
Autorzy:
Jóźwiakowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/286701.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
fosfor
oczyszczanie ścieków
opoka
badanie modelowe
phosphorus
wastewater treatment
model studies
Opis:
W pracy przedstawiono wstępne wyniki badań, dotyczące niekonwencjonalnego sposobu usuwania fosforu, przy wykorzystaniu skały wapiennej - opoki, wcześniej poddanej dekarbonizacji w temperaturze 900°C. Badania prowadzono w okresie 6 tygodni na modelowej oczyszczalni ścieków ze złożem piaskowym bez opoki i z opoką. Podczas badań analizowano stężenie fosforu w ściekach dopływających i odpływających z oczyszczalni. Wyniki badań wykazały, że opoka bardzo dobrze sorbuje fosfor ze ścieków bytowych. Średnia skuteczność usuwania fosforu ogólnego w modelowej oczyszczalni ścieków z opoką (90,9%) była ponad dwukrotnie większa, niż w tej samej oczyszczalni bez opoki (42,4%). Szersze zastosowanie tej skały, do usuwania fosforu, wymaga jednak prowadzenia dalszych, szczegółowych badań, które powinny mieć m.in. na celu określenie długości czasu sorpcji fosforu przez opokę.
The paper presents preliminary results of the study on an alternative method of phosphorus removal by using limestone which was first decarbonized at 900°C. The 6-week research was conducted in a model sewage treatment plant with a sandy bed with and without the application of calcareous rock. Phosphorus concentration in sewage influents and effluents was analized. The results suggest that limestone is a very good sorbing agent in relation to phosphorus occurring in domestic sewage. The model sewage treatment plant was on average twice as efficient (90.9%) when calcareous rock was used as it was without the application of the rock (42.4%). However, the use of this rock in phosphorus removal on a large scale requires further, more detailed research which, among other things, should determine the duration of phosphorus sorption by calcareous rock.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 5(80), 5(80); 249-256
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tryptophan-Based Organoclay for Aqueous Naphthol Blue Black Removal – Preparation, Characterization, and Batch Adsorption Studies
Autorzy:
Julinawati, Julinawati
Febriani, Febriani
Mustafa, Irfan
Fathurrahmi, Fathurrahmi
Rahmi, Rahmi
Sheilatina, Sheilatina
Ahmad, Khairunnas
Puspita, Kana
Iqhrammullah, Muhammad
Powiązania:
https://bibliotekanauki.pl/articles/27323827.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
amino acids
bentonite
diazo dye
freundlich
Sips isotherm model
montmorillonite
textile wastewater
Opis:
To prevent the serious threat of textile wastewater, researchers have developed adsorption-based wastewater treatment using cheap, yet effective, adsorbent materials. Of which is natural bentonite, that has the advantages for adsorption due to its porous structure and functional groups but still suffers from its low affinity against anionic and hydrophilic azo dyes. Herein, we aimed of improving the affinity by amino acid tryptophan embedment into the locally isolated natural bentonite collected from Aceh Province, Indonesia. The prepared bentonite samples were characterized using Fourier transform infrared, X-ray diffraction, and scanning electron microscopy. Adsorptive removal was performed on naphthol blue black (NBB) in a batch system with variations of contact time, pH, and adsorbent dosage. The isotherm studies were carried out at optimum conditions (contact time=15 minutes; pH 1; adsorbent dosage=0.2 g) with several models including Langmuir, Freundlich, Sips, and Redlich-Peterson isotherm models. The characterization results revealed that the modification altered its functional group, crystallinity, and micro-surface morphology that add more benefits for adsorption. At optimum conditions, 99.2% NBB has been successfully removed from the aqueous solution. The isotherm studies suggested that the NBB adsorption onto the tryptophane-modified natural bentonite was dependent on Sips isotherm model (R2=0.999; root-mean-square-errors=1.11×10-4 mg/g).
Źródło:
Journal of Ecological Engineering; 2023, 24, 7; 274--284
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical Prediction of Sorption Processes of Heavy Metals on Cation Exchangers Using the Thomas Model
Autorzy:
Koliehova, Anastasiia
Trokhymenko, Hanna
Gomelya, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/1955572.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
heavy metals
ion exchange
sorption
Thomas model
wastewater treatment
Opis:
On a production scale, it is advisable to use mathematical models for predicting the treatment of effluents from heavy metal ions, which will increase the efficiency of enterprises. The sorption processes of copper, zinc, nickel and cadmium ions on the KU-2-8 cation exchange resin in the acid form at different concentrations were studied in this scientific work. At the same time, the sorption curves calculated were constructed using the Thomas model. The study results showed that this model very clearly describes the sorption processes of metals on the resin. Thus, it can be used to predict the processes of wastewater treatment in production.
Źródło:
Journal of Ecological Engineering; 2021, 22, 9; 232-236
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Ability of Peat in Adsorption of Biogenic Elements from Water Environment
Autorzy:
Matsuska, Oksana
Suchorska, Olga
Gumnitsky, Jaroslaw
Powiązania:
https://bibliotekanauki.pl/articles/124877.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
ammonium nitrogen
phosphates
adsorption
peat
adsorption isotherms
coefficient of determination
Langmuir model
Freundlich model
Opis:
The possibilities of using a natural sorbent – peat for the wastewater treatment of ammonium ions and phosphates discharged from runoff into natural reservoirs at high concentrations were investigated. The peat of from the Vereshchytsya-Yanovske deposit of Ukraine of two depths: lowland and upland, was studied. It was established that the lowland samples of peat have higher sorption properties to the investigated pollutants from the aquatic environment than the upland ones. A greater moisture loss in the lowland peat species was observed, as well as the major part of the plant fibers in its structure, which explains its sorption properties. Due to the high content of humic substances, the extraction of cations from the water by peat can occur due to the ion exchange. The adsorption isotherms of both ammonium and phosphate ions on the top and lowland peat species of the Vereshchytsya-Yanovske deposit were constructed and presented. The adsorption isotherm obtained in the experimental studies was used to mathematically establish the isotherm equation, using the Langmuir and Freundlich models to describe the equilibrium of the sorption processes under study. The degree of appropriation of linear equations to the experimental data was evaluated on the basis of the deterministic coefficient, which enabled to determine that in each case the Langmuir equations describe the adsorption isotherms more adequately.
Źródło:
Journal of Ecological Engineering; 2020, 21, 4; 224-230
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling performance in reverse osmosis wastewater treatment post-trial coke in the integrated systems based on the assumptions of the relaxation model
Modelowanie wydajności procesu odwróconej osmozy w oczyszczaniu poprocesowych wód koksowniczych w układzie zintegrowanym w oparciu o założenia modelu relaksacyjnego
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/395870.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków koksowniczych
koagulacja objętościowa
model relaksacyjny
odwrócona osmoza
coking wastewater
volume coagulation
advanced oxidation
relaxation model
reverse osmosis
Opis:
The paper presents the results of studies on coking wastewater, coming from the coke plant "Koksownia Czestochowa Nowa" in two integrated systems associating coagulation volume and advanced oxidation with reverse osmosis. The process of coagulation were performed using iron sulfate (III), (PIX 113) of 400 mg/dm3 and wastewater acidity at pH = 9. The second processes - advanced oxidation was carried out using Fenton's reagent. The concentration of iron (II) was 0.8 g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke post-process water after its initial treatment was subjected to high-pressure membrane filtration. In the process of reverse osmosis a flat polyamide membrane ADF of Osmonics was used. Transmembrane pressure was 2 MPa and the linear speed of water on the membrane surface of 2m/s. Comparison of the effectiveness of wastewater treatment in both tested systems has shown that the system combining the advanced oxidation with reverse osmosis is more effective. In addition, this study attempts to model effectiness of the process of reverse osmosis in both studied systems, based on the assumptions of a relaxation model. An experimentally determined dependence of changes in volume of treated wastewater fluxes from the time of the high-pressure membrane filtration, and the values of time constant efficiency of the process characterized by a decrease to below economic viability allowed us fo verify this model.
W pracy zaprezentowano wyniki badań oczyszczania ścieków koksowniczych, pochodzących z zakładu koksowniczego "Koksownia Częstochowa Nowa", w dwóch układach zintegrowanych kojarzących koagulację objętościową oraz pogłębione utlenianie z procesem odwróconej osmozy. Proces koagulacji realizowano z zastosowaniem siarczanu żelaza (III), (PIX 113) o dawce 400 mg/dm3 i pH ścieków na poziomie pH=9. Drugi z procesów - pogłębione utlenianie przeprowadzono stosując odczynnik Fentona. Stężenie jonów żelaza (II) wynosiło 0,8 g/dm3 natomiast nadtlenku wodoru 2,4 g/dm3. Poprocesowe wody koksownicze po ich wstępnym oczyszczeniu poddawano wysokociśnieniowej filtracji membranowej. W procesie odwróconej osmozy stosowano poliamidową membranę płaską ADF amerykańskiej firmy Osmonics. Ciśnienie transmembranowe wynosiło 2 MPa natomiast liniowa prędkość ścieków nad powierzchnią membrany 2m/s. Porównanie efektywności oczyszczania przedmiotowych ścieków w obu układach badawczych wykazało, że skuteczniejszym okazał się system łączący pogłębione utlenianie z odwrócona osmozą. Ponadto w niniejszej pracy podjęto próbę modelowania wydajności procesu odwróconej osmozy w obu przebadanych układach w oparciu o założenia modelu relaksacyjnego. Wyznaczone na drodze doświadczalnej zależności zmiany wielkości strumieni oczyszczanych ścieków od czasu prowadzenia wysokociśnieniowej filtracji membranowej oraz wartości stałych czasowych charakteryzujących spadek wydajności procesu poniżej opłacalności ekonomicznej pozwoliły na weryfikację tego modelu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 19-32
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of Design Model Constants for a Constructed Wetland with Palm Kernel Shell as Substrate for Slaughterhouse Wastewater Treatment
Autorzy:
Okoye, Nelson Mbanefo
Madubuike, Chimaobi Nnaemeka
Nwuba, Ifeanyi Uba
Powiązania:
https://bibliotekanauki.pl/articles/1161604.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Constructed Wetland
Eichhornia crassipes
Palm Kernel Shell
Physicochemical Parameters
Slaughterhouse Wastewater
Thalia geniculate
k-C* Model
Opis:
Design of horizontal subsurface flow constructed wetlands using the state of the art k-C* first order model requires the use of correct model constants to ensure that the design systems meets the required treatment standards. The aim of the study was to estimate the model constants for the design of a field scale horizontal subsurface flow constructed wetland to treat slaughterhouse wastewater using palm kernel shell as substrate. A 40 days column incubation was conducted and the model was fitted to experimental data. Rate constant (k20) values of 0.604/day, 0.623/day, 0.278/day, 0.323/day and 0.306/day were obtained for BOD, TSS, NH4-N, NO3-N and PO43-. Estimated model constants were compared to the universal values in the literature which revealed very significant variations in the obtained wetland surface area.
Źródło:
World Scientific News; 2018, 112; 153-164
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic simulation for wastewater treatment plants management: Case of Souk-Ahras region, north-eastern Algeria
Dynamiczna symulacja zarządzania oczyszczalniami ścieków: przykład regionu Souk-Ahras w północno-wschodniej Algierii
Autorzy:
Sabri, D.
Yassine, D.
Yahia, H.
Dounia, M.
Powiązania:
https://bibliotekanauki.pl/articles/292322.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
activated sludge
Algeria
ASM1
simulation
wastewater
Algieria
model ASM1
osad czynny
symulacja
ścieki
Opis:
Treatment performances of two wastewater treatment plants (WWTPs), located in North-Eastern Algeria (Souk-Ahras and Sedrata) were tested using ASM1 model. The model, to be considered as a decision tool for the appropriate management of activated sludge systems, served for the prediction of both WWTP behaviours under different operating conditions. In Sedrata WWTP the first management scenarios is based on an increase of inflow rate, taking into account a new transfer volume from a nearby zone. In a second scenerio, the ultimate flow of 40 000 m3∙d–1 is estimated. Regarding Souk-Ahras WWTP, three scenarios were tested. The first tested the impact of an increase of the extraction flow rate and yielded a reduction by 37% of sludge production. The second dealt with the management of the mass budget of substrata and biomass. Finally, the third application was devoted to the estimation of the plant ultimate capacity, estimated to be 60 000 m3∙d–1.
Stosując model ASM1, testowano działanie dwóch oczyszczalni ścieków zlokalizowanych w północnowschodniej Algierii w miejscowościach Souk-Ahras i Sedrata. Model, traktowany jako narzędzie w podejmowaniu decyzji co do właściwego zarządzania systemem osadu czynnego, służył przewidywaniu zachowania się obu oczyszczalni w różnych warunkach operacyjnych. W oczyszczalni Sedrata w pierwszym scenariuszu zarządzania założono zwiększoną prędkość przepływu uwzględniającą dodatkową objętość ścieków dostarczaną z pobliskiej strefy. W drugim oszacowano końcową przepustowość równą 40 000 m3∙d–1. W odniesieniu do oczyszczalni w Souk-Ahras testowano trzy scenariusze. W pierwszym rozpatrywano wpływ zwiększonej prędkości przepływu, w efekcie uzyskano 37-procentowe zmniejszenie produkcji osadu. Drugi scenariusz dotyczył zarządzania bilansem masy podłoża i biomasy. Trzeci z kolej polegał na ocenie docelowej przepustowości ścieków szacowanej na 60 000 m3∙d–1.
Źródło:
Journal of Water and Land Development; 2017, 34; 221-231
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption of Lead, Zinc, and Nickel Ions from Wastewater Using Coriander Seeds as an Adsorbent
Autorzy:
Shamkhi, Hibatallah Jamil
Hussein, Tamara Kawther
Powiązania:
https://bibliotekanauki.pl/articles/2025731.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
coriander seed
adsorption
heavy metals
isotherm model
wastewater
kinetic model
Opis:
This research focused on using coriander seeds as low cost adsorbent to remove heavy metals ions such as lead, zinc, and nickel from wastewater. Different parameters were studied to obtain the best results, such as pH, contact time, adsorbent dosage, concentration of initial metals and agitation speed. The highest results were obtained at pH 6, 105 min contact time, 1 g/100 ml dosage, 50 mg/l initial concentration of metal ions and 200 rpm agitation speed at temperature 25 ± 2 °C, which were 95.926%, 89.799% and 79.255% for lead, zinc and nickel ions, respectively. The results were also categorized as the Langmuir and Freundlich models, and found that the Freundlich isotherm fit the experimental data better than the Langmuir isotherm. The pseudo-second order was shown to have a high degree of fitness based on kinetic data. The adsorbent was characterized using a variety of techniques, including Fourier transform infrared spectroscopy (FTIR), Field Emission Scanning Electron Microscope (FESEM).
Źródło:
Journal of Ecological Engineering; 2022, 23, 1; 158-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie sztucznych sieci neuronowych do modelowania procesu oczyszczania ścieków w małej oczyszczalni ścieków
Using Artificial Neural Networks for Modeling Wastewater Treatment in Small Wastewater Treatment Plant
Autorzy:
Skoczko, I.
Ofman, P.
Szatyłowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/1817960.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczalnia ścieków
model black box
sztuczne sieci neuronowe
wastewater treatment plant
artificial neural networks
Opis:
Celem pracy było opracowanie modelu „Black Box” dla Miejskiej Oczyszczalni Ścieków w Stawiskach. Badana oczyszczalnia ścieków na podstawie równoważnej liczby mieszkańców (RLM) zaliczana jest do obiektów z II grupy, zgodnie z Rozporządzeniem Ministra Środowiska z 11 listopada 2014 roku, w których monitoring jakości ścieków oczyszczonych obejmuje ilość zawiesin ogólnych, BZT5 i ChZTCr. Model matematyczny został opracowany na podstawie badań prowadzonych w latach 2005-2013, które dotyczyły jakości ścieków surowych i oczyszczonych. W modelu jako zmienne wejściowe uwzględniono ilość mieszkańców miejscowości, ilość ścieków dopływających systemem kanalizacyjnym oraz ilość ścieków dowożonych. Opracowana sieć neuronowa wykazywała bardzo dobre dopasowanie do parametrów rzeczywistych. Opracowany model regresyjnym odznaczał się dobrym dopasowanie wartości przewidywanych do obserwowanych. Współczynniki korelacji uzyskane dla tych par zmiennych równe były dla BZT5 0,99, dla ChZTCr 0,94 i dla zawiesin ogólnych 0,97, przy wartościach średniego błędu bezwzględnego równego dla poszczególnych zmiennych odpowiednio 0,37; 5,49 i 1,72.
The aim of this study was to develop a model of "Black Box" for Municipal Wastewater Treatment Plant in Stawiskach. This sewage treatment plant based on of population equivalent (pe) is among the objects from the second group, in accordance with the Regulation of the Minister of Environment of 11 November 2014, in which monitoring of the effluent includes the amount of total suspended solids, BOD5 and COD. A mathematical model was developed based on research conducted in the years 2005-2013, which concerned the quality of raw sewage and sewage. In the model as input variables takes into account the number of inhabitants of the village, the amount of sewage influent sewer system and the amount of waste imported from the city. The developed neural network showed a very good fit to the actual parameters. Developed regression model was characterized by a good fit to the observed predicted values. The correlation coefficients obtained for these couples variables were equal to 0.99 BOD, COD norm of 0.94 and 0.97 for total suspended solids, with values of average absolute error for each variable equal to 0.37; 5.49 and 1.72.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 1; 493-506
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chronopotentiometric and chronoamperometric electrocoagulation of wastewater in a static system
Statyczna elektrokoagulacja ścieków modelowych
Autorzy:
Smoczyński, L.
Zaborowska-Piworowicz, A.A.
Wardzyńska, R.
Załęska-Chróst, B.
Dłużyńska, K.T.
Powiązania:
https://bibliotekanauki.pl/articles/388537.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elektrokoagulacja
system statyczny
ścieki modelowe
electrocoagulation
chronopotentiometr
chronoamperometr
static system
model wastewater
Opis:
This study presents the results of electrochemical treatment of model wastewater. It compares the parameters and the results of wastewater electrolysis performed by chronopotentiometric electrocoagulation (CHRP) at constant current intensity (I = const) and chronoamperometric electrocoagulation (CHRA) at constant voltage (U = const). Electrolysis was carried out in a static system with the use of an electrolyzer with aluminum electrodes. A six-electrode electrolyzer (three cathodes and three anodes) was applied. The chemical oxygen demand (COD), turbidity, color intensity, suspended solids and total phosphorus concentration of the solution were determined after electrocoagulation and sludge sedimentation.
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const) oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-eIektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 3; 231-238
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies