Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model wastewater" wg kryterium: Temat


Tytuł:
Electrocoagulation of model wastewater using aluminum electrodes
Autorzy:
Smoczyński, L.
Muńska, K. T.
Pierożyński, B.
Kosobucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/779115.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
model wastewater
dose of aluminum electrocoagulant
Opis:
Electrocoagulation makes an alternative method to chemical coagulation. This paper presents the results obtained during the electrocoagulation of the model wastewater using aluminum electrodes. The wastewater was treated by means of chronopotentiometric electrocoagulation process in a static system, at the constant current I = 0.3 A; therefore higher doses of electrocoagulant required longer electrocoagulation time. Changes in zeta potential, pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the aluminum electrocoagulant was proposed through application of the third degree polynomial function rather than the parabolic equation. An increase in the electrocoagulant dose raised the share of sweep fl occulation in the studied treatment process, resulting in the effective removal over 90% of phosphorus compounds from the system.
Źródło:
Polish Journal of Chemical Technology; 2012, 14, 3; 66-70
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statyczna elektrokoagulacja ścieków modelowych
Statical electrocoagulation of model wastewater
Autorzy:
Smoczyński, L.
Zaborowska-Piworowicz, A.
Wardzyńska, R.
Załęska-Chróst, B.
Dłużyńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/126390.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elektrokoagulacja
system statyczny
ścieki modelowe
electrocoagulation
static system
model wastewater
Opis:
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const), oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-elektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
This paper presents the results of electrochemical treatment of model wastewater. Parameters and results of electrolytic treatment of the model wastewater under chronopotentiometric (CHRP) conditions, ie at constant current (I = const), and under chronoamperomtric (CHRA) conditions, ie at constant voltage (U = const), were compared in the study. Electrolysis was performed in a static system, using an electrolyser with aluminium electrodes. Six-electrode (three cathodes and three anodes) electrolyzers were applied. Chemical oxygen demand (COD), color, turbidity, suspended solids and total phosporus concentration were measured after electrocoagulation and sludge sedimentation. The process of static electrocoagulation was found to be an effective method for model wastewater treatment.
Źródło:
Proceedings of ECOpole; 2009, 3, 2; 501-507
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrocoagulation of Model Wastewater Using Iron Elect
Elektrokoagulacja ścieków modelowych na elektrodach żelaznych
Autorzy:
Smoczyński, L.
Muńska, K. T.
Pierożyński, B.
Kosobucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/388987.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
model wastewater
dose of iron electrocoagulant
ścieki modelowe
dawka elektrokoagulantu żelazowego
Opis:
This paper presents the results of electrocoagulation of model wastewater using iron electrodes under laboratory conditions. The investigated wastewater was susceptible to electrolytic treatment, and the model system supported the performance of analyses in seven replications, generating a database for reliable statistical and mathematical processing. Wastewater was treated by chronopotentiometric electrocoagulation in a static system at constant current intensity I = 0.3 A. Changes in supply voltage for I = const were registered over time. Changes in pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the iron electrocoagulant was proposed by relying on the third degree polynomial function rather than the parabolic equation. The proposed method, justified theoretically and demonstrated practically, enabled precise determination of the electrocoagulant dose. An increase in the electrocoagulant dose increased the share of sweep electrocoagulation in the wastewater treatment process.
W pracy przedstawiono wyniki badań laboratoryjnych procesu elektrokoagulacji ścieków modelowych na elektrodach żelaznych. Użyte ścieki okazały się podatne na oczyszczanie elektrolityczne i tym samym, jako układ modelowy, umożliwiły prowadzenie badań aż w 7 powtórzeniach, co z kolei zapewniło bazę danych nadającą się do wiarygodnej obróbki statystyczno-matematycznej. Oczyszczanie ścieków prowadzono w statycznych warunkach chronopotencjometrycznych, tj. przy stałym prądzie I = 0,3 A. Każdorazowo rejestrowano zmiany napięcia zasilania w czasie zapewniające I = const. Oznaczano zmiany pH, zawiesin i mętności, ChZT oraz fosforu ogólnego w oczyszczanych ściekach. W odróżnieniu od metody wyznaczania dawki koagulantu z równania odpowiedniej paraboli, dla badanego procesu elektrokoagulacji zaproponowano oryginalną, nową metodę obliczania dawki optymalnej elektrokoagulantu żelazowego z równania wielomianu III stopnia. Metoda ta, uzasadniona teoretycznie i praktycznie, umożliwiała każdorazowo bardzo precyzyjne określenie takiej dawki. Stwierdzono, że wzrost dawki elektrokoagulantu żelazowego w układzie prowadzi do zwiększenia udziału elektrokoagulacji „zamiatającej” w badanym procesie oczyszczania ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2013, 20, 10; 1143-1152
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chronopotentiometric and chronoamperometric electrocoagulation of wastewater in a static system
Statyczna elektrokoagulacja ścieków modelowych
Autorzy:
Smoczyński, L.
Zaborowska-Piworowicz, A.A.
Wardzyńska, R.
Załęska-Chróst, B.
Dłużyńska, K.T.
Powiązania:
https://bibliotekanauki.pl/articles/388537.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elektrokoagulacja
system statyczny
ścieki modelowe
electrocoagulation
chronopotentiometr
chronoamperometr
static system
model wastewater
Opis:
This study presents the results of electrochemical treatment of model wastewater. It compares the parameters and the results of wastewater electrolysis performed by chronopotentiometric electrocoagulation (CHRP) at constant current intensity (I = const) and chronoamperometric electrocoagulation (CHRA) at constant voltage (U = const). Electrolysis was carried out in a static system with the use of an electrolyzer with aluminum electrodes. A six-electrode electrolyzer (three cathodes and three anodes) was applied. The chemical oxygen demand (COD), turbidity, color intensity, suspended solids and total phosphorus concentration of the solution were determined after electrocoagulation and sludge sedimentation.
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const) oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-eIektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 3; 231-238
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Destabilizacja ścieków modelowych w procesie koagulacji chemicznej
Destabilization of model wastewater in the chemical coagulation process
Autorzy:
Smoczyński, L.
Muńska, K. T.
Kosobucka, M.
Pierożyński, B.
Wardzyńska, R.
Załęska-Chróst, B.
Powiązania:
https://bibliotekanauki.pl/articles/127099.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
koagulacja chemiczna
ścieki modelowe
dawka koagulantu
chemical coagulation
model wastewater
coagulant dose
Opis:
W niniejszej pracy przedstawiono, opisano i zinterpretowano wyniki badań laboratoryjnych procesu koagulacji-flokulacji ścieków modelowych. Zastosowane ścieki modelowe okazały się podatne na oczyszczanie metodą koagulacji chemicznej. Zastosowano i porównano dwa komercyjne koagulanty: PAC - wyprodukowany w zakładach chemicznych DEMPOL-ECO oraz PIX - wyprodukowany przez firmę KEMIPOL. Do przedstawienia i analizy uzyskanej bazy danych doświadczalnych z powodzeniem zastosowano model matematyczny w postaci wielomianu drugiego stopnia. Minimum takiej paraboli każdorazowo stanowiła dawka koagulantu precyzyjnie obliczana i traktowana jako dawka optymalna. Zastosowanie wyższej, aniżeli optymalna, dawki koagulantu prowadziło każdorazowo do obniżenia stopnia oczyszczenia koagulowanych ścieków. Szczegółowa analiza wyników usuwania mętności, zawiesin, fosforu ogólnego i zanieczyszczeń określanych w skali ChZT pokazała, że PAC skuteczniej i wydajniej, aniżeli PIX, koagulował badane ścieki modelowe.
This paper discusses the results of laboratory analyses of the coagulation and flocculation of model wastewater. The investigated wastewater was susceptible to treatment by chemical coagulation. The effectiveness of two commercial coagulants, PAC produced at the DEMPOL-ECO Chemical Plant and PIX manufactured by KEMIPOL, was compared. A mathematical model relying on a second-degree polynomial was used to describe and analyze experimental data. In each case, the parabola minimum point was a precisely determined coagulant dose, regarded as the optimal dose. The application of a coagulant dose higher than the optimal dose reduced the effectiveness of wastewater treatment by coagulation. A detailed analysis of turbidity, suspended solids, total phosphorus and pollutant removal measured by the COD test revealed that PAC was a more effective and a more efficient coagulant than PIX.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 399-404
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrokoagulacja ścieków modelowych na elektrodach żelaznych
Electrocoagulation of model wastewater using iron electrodes
Autorzy:
Smoczyński, L.
Muńska, K. T.
Pierożyński, B.
Kosobucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/125995.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ścieki modelowe
dawka elektrokoagulantu żelazowego
elektrokoagulant żelazowy
model wastewater
dose of iron electrocoagulant
Opis:
Przedstawiono wyniki badań laboratoryjnych procesu elektrokoagulacji ścieków modelowych na elektrodach żelaznych. Użyte ścieki okazały się podatne na oczyszczanie elektrolityczne i tym samym, jako układ modelowy, umożliwiły prowadzenie badań aż w 7 powtórzeniach, co z kolei zapewniło bazę danych, nadającą się do wiarygodnej obróbki statystyczno-matematycznej. Oczyszczanie ścieków prowadzono w statycznych warunkach chronopotencjometrycznych, tj. przy stałym natężeniu prądu I = 0,3 A. Każdorazowo rejestrowano zmiany napięcia zasilania w czasie, zapewniające I = const. Oznaczano zmiany pH, zawiesin i mętności, ChZT oraz fosforu ogólnego w oczyszczanych ściekach. W odróżnieniu od metody wyznaczania dawki koagulantu z równania odpowiedniej paraboli dla badanego procesu elektrokoagulacji zaproponowano oryginalną, nową metodę obliczania dawki optymalnej elektrokoagulantu żelazowego z równania wielomianu III stopnia. Metoda ta, uzasadniona teoretycznie i praktycznie, umożliwiała każdorazowo bardzo precyzyjne określenie takiej dawki. Stwierdzono, że wzrost dawki elektrokoagulantu żelazowego w układzie prowadzi do zwiększenia udziału elektrokoagulacji „zamiatającej” w badanym procesie oczyszczania ścieków.
This paper presents the results of electrocoagulation of model wastewater using iron electrodes under laboratory conditions. The investigated wastewater was susceptible to electrolytic treatment, and the model system supported the performance of analyses in seven replications, generating a database for reliable statistical and mathematical processing. Wastewater was treated by chronopotentiometric electrocoagulation in a static system at constant current intensity I = 0.3 A. Changes in supply voltage for I=const were registered over time. Changes in pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the iron electrocoagulant was proposed by relying on the third degree polynomial function rather than the parabolic equation. The proposed method, justified theoretically and demonstrated practically, enabled precise determination of the electrocoagulant dose. An increase in the electrocoagulant dose increased the share of sweep electrocoagulation in the wastewater treatment process.
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 402-408
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption of Lead, Zinc, and Nickel Ions from Wastewater Using Coriander Seeds as an Adsorbent
Autorzy:
Shamkhi, Hibatallah Jamil
Hussein, Tamara Kawther
Powiązania:
https://bibliotekanauki.pl/articles/2025731.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
coriander seed
adsorption
heavy metals
isotherm model
wastewater
kinetic model
Opis:
This research focused on using coriander seeds as low cost adsorbent to remove heavy metals ions such as lead, zinc, and nickel from wastewater. Different parameters were studied to obtain the best results, such as pH, contact time, adsorbent dosage, concentration of initial metals and agitation speed. The highest results were obtained at pH 6, 105 min contact time, 1 g/100 ml dosage, 50 mg/l initial concentration of metal ions and 200 rpm agitation speed at temperature 25 ± 2 °C, which were 95.926%, 89.799% and 79.255% for lead, zinc and nickel ions, respectively. The results were also categorized as the Langmuir and Freundlich models, and found that the Freundlich isotherm fit the experimental data better than the Langmuir isotherm. The pseudo-second order was shown to have a high degree of fitness based on kinetic data. The adsorbent was characterized using a variety of techniques, including Fourier transform infrared spectroscopy (FTIR), Field Emission Scanning Electron Microscope (FESEM).
Źródło:
Journal of Ecological Engineering; 2022, 23, 1; 158-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear stabilizing control of an uncertain bioprocess model
Autorzy:
Dimitrova, N.
Krastanov, M.
Powiązania:
https://bibliotekanauki.pl/articles/930090.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
stabilność asymptotyczna
sterowanie nieliniowe
wastewater treatment model
local bifurcations of steady states
asymptotic stabilization
extremum seeking
uncertain data
Opis:
In this paper we consider a nonlinear model of a biological wastewater treatment process, based on two microbial populations and two substrates. The model, described by a four-dimensional dynamic system, is known to be practically verified and reliable. First we study the equilibrium points of the open-loop system, their stability and local bifurcations with respect to the control variable. Further we propose a feedback control law for asymptotic stabilization of the closed-loop system towards a previously chosen operating point. A numerical extremum seeking algorithm is designed to stabilize the dynamics towards the maximum methane output flow rate in the presence of coefficient uncertainties. Computer simulations in Maple are reported to illustrate the theoretical results.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2009, 19, 3; 441-454
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetic Model of Wastewater Treatment in Horizontal Flow Flotation Tank
Autorzy:
Antonova, Ekaterina Sergeevna
Sazonov, Dmitry Vasil'evich
Powiązania:
https://bibliotekanauki.pl/articles/123615.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
flotation
mathematical model
wastewater treatment
horizontal flotation tank
Opis:
The flotation wastewater treatment was considered in the paper. The main stages and parameters of flotation process were pointed out. The multistage flotation model considering all main stages of flotation process is presented. However, its main disadvantage is that for the definition of constant characterizing the bubble-particle aggregate formation, the constant value of superficial gas velocity was used, which is incorrect for horizontal flow flotation tank. The modified multistage flotation model with superficial gas velocity as the function of time was proposed. The experiments were carried out on a laboratory setup with a pneumohydraulic system of aeration in order to verify the proposed model. The comparison of experimental and theoretical results proved the importance of superficial gas velocity change consideration.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 190-196
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical Prediction of Sorption Processes of Heavy Metals on Cation Exchangers Using the Thomas Model
Autorzy:
Koliehova, Anastasiia
Trokhymenko, Hanna
Gomelya, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/1955572.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
heavy metals
ion exchange
sorption
Thomas model
wastewater treatment
Opis:
On a production scale, it is advisable to use mathematical models for predicting the treatment of effluents from heavy metal ions, which will increase the efficiency of enterprises. The sorption processes of copper, zinc, nickel and cadmium ions on the KU-2-8 cation exchange resin in the acid form at different concentrations were studied in this scientific work. At the same time, the sorption curves calculated were constructed using the Thomas model. The study results showed that this model very clearly describes the sorption processes of metals on the resin. Thus, it can be used to predict the processes of wastewater treatment in production.
Źródło:
Journal of Ecological Engineering; 2021, 22, 9; 232-236
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies