Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model przejściowy" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Transient model of heat pump cycle
Autorzy:
Matysko, R.
Powiązania:
https://bibliotekanauki.pl/articles/95327.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
heat pump
transient model
refrigeration cycle
MIMO controller
pompa ciepła
model przejściowy
obieg chłodniczy
sterowanie MIMO
Opis:
This paper introduce a transient model of the propane heat pump cycle. The heat pump cycle model includes: a compressor model, a condenser model in lumped parameters, an evaporator model in lumped parameters, an expansion valve model, a heat source model (cooling chamber), a PID control system for heat recovery from superheated refrigerant vapour. The model allows estimate inertia of the heat pump cycle with the system of the heat recovery from superheated propane vapor. The presented theoretical model can determine unsteady and steady state conditions of the different subsystems in the heat pump cycle (condenser, evaporator, compressor). The article presents the results of calculations and determines the time of reaching steady states of the key systems of the heat pump system. The article also presents (in a graphical form) the behavior of the system where the setting was changed after reaching the steady state after 2000s from 50kW to 40kW at the thermal load of the additional heat recovery exchanger.
Źródło:
Journal of Mechanical and Energy Engineering; 2018, 2, 2; 139-146
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes of the thermodynamic parameters in failure conditions of the micro-CHP cycle
Autorzy:
Matysko, R.
Mikielewicz, J.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/239967.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
micro-CHP system
transient model
failure states
multifuel boiler system
heating system
układ mikro CHP
model przejściowy
stan awaryjny
kocioł
system ogrzewania
Opis:
The paper presents the calculations for the failure conditions of the ORC (organic Rankine cycle) cycle in the electrical power system. It analyses the possible reasons of breakdown, such as the electrical power loss or the automatic safety valve failure. The micro-CHP (combined heat and power) system should have maintenance-free configuration, which means that the user does not have to be acquainted with all the details of the ORC system operation. However, the system should always be equipped with the safety control systems allowing for the immediate turn off of the ORC cycle in case of any failure. In case of emergency, the control system should take over the safety tasks and protect the micro-CHP system from damaging. Although, the control systems are able to respond quickly to the CHP system equipped with the inertial systems, the negative effects of failure are unavoidable and always remain for some time. Moreover, the paper presents the results of calculations determining the inertia for the micro-CHP system of the circulating ORC pump, heat removal pump (cooling condenser) and the heat supply pump in failure conditions.
Źródło:
Archives of Thermodynamics; 2014, 35, 1; 43-59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical modelling of heat transfer in liquid flat-plate solar collector tubes
Autorzy:
Zima, W.
Dziewa, P.
Powiązania:
https://bibliotekanauki.pl/articles/240431.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kolektor słoneczny
model matematyczny
rozwiązanie dokładne
stan przejściowy
exact solution
mathematical model
solar collector
transient state
Opis:
The paper presents a one-dimensional mathematical model for simulating the transient processes which occur in the liquid flat-plate solar collector tubes. The proposed method considers the model of collector tube as one with distributed parameters. In the suggested method one tube of the collector is taken into consideration. In this model the boundary conditions can be time-dependent. The proposed model is based on solving the equation describing the energy conservation on the fluid side. The temperature of the collector tube wall is determined from the equation of transient heat conduction. The derived differential equations are solved using the implicit finite difference method of iterative character. All thermo-physical properties of the operating fluid and the material of the tube wall can be computed in real time. The time-spatial heat transfer coefficient at the working fluid side can be also computed on-line. The proposed model is suitable for collectors working in a parallel or serpentine tube arrangement. As an illustration of accuracy and effectiveness of the suggested method the computational verification was carried out. It consists in comparing the results found using the presented method with results of available analytic solutions for transient operating conditions. Two numerical analyses were performed: for the tube with temperature step function of the fluid at the inlet and for the tube with heat flux step function on the outer surface. In both cases the conformity of results was very good. It should be noted, that in real conditions such rapid changes of the fluid temperature and the heat flux of solar radiation, as it was assumed in the presented computational verification, do not occur. The paper presents the first part of the study, which aim is to develop a mathematical model for simulating the transient processes which occur in liquid flat-plate solar collectors. The experimental verification of the method is a second part of the study is not presented in this paper. In order to perform this verification, the mathematical model would be completed with additional energy conservation equations. The experimental verification will be carry out in the close future.
Źródło:
Archives of Thermodynamics; 2010, 31, 2; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Software reliability growth modeling for agile software development
Autorzy:
Rawat, S.
Goyal, N.
Ram, M.
Powiązania:
https://bibliotekanauki.pl/articles/329876.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
software reliability
nonhomogeneous poison process
transient faults
permanent faults
Musa model
niezawodność oprogramowania
błąd przejściowy
zwarcie trwałe
Opis:
The frequent incremental release of software in agile development impacts the overall reliability of the product. In this paper, we propose a generic software reliability model for the agile process, taking permanent and transient faults into consideration. The proposed model is implemented using the NHPP (non-homogenous Poisson process) and the Musa model. The comparison of the two implementations yields an effective, empirical and reliable model for agile software development.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2017, 27, 4; 777-783
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model matematyczny zjawisk cieplno-wilgotnościowych w ośrodkach porowatych z uwzględnieniem powietrza rozpuszczonego w wodzie
Mathematical model of hydro-thermal phenomena in porous media considering air dissolved in water
Autorzy:
Gawin, D.
Sanavia, L.
Powiązania:
https://bibliotekanauki.pl/articles/363000.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
powietrze rozpuszczone w wodzie
nasycone ośrodki porowate
stan przejściowy
procesy cieplno-wilgotnościowe
model numeryczny
air dissolved in water
saturated porous media
transient state
hydro-thermal phenomena
numerical model
Opis:
W pracy przedstawiono model matematyczny zjawisk cieplno-wilgotnościowych w odkształcalnym ośrodku porowatym. częściowo lub w pełni nasyconym wodą, uwzględniający rozpuszczone w niej powietrza, oraz metodę numerycznego rozwiązania równań tego modelu. Omówiono podstawy fizyczne rozpuszczalności powietrza w wodzie i tworzenia się pęcherzyków gazu po obniżeniu się ciśnienia wody, a także przedyskutowano wpływ ciśnienia kapilarnego na te zjawiska. Numerycznie przeanalizowano wpływ rozpuszczonego powietrza na przebieg procesu przejściowego między stanem całkowitego i częściowego nasycenia wodą podczas szybkiego grawitacyjnego wypływu wody przez dno kolumny wypełnionej materiałem porowatym.
A mathematical model of hydrothermal phenomena in defonnable porous media, partially or fully saturated with water, considering the air dissolved in water, and a method of numerical solution of the model equations are presented. Physical fundamentals of air dissolution in water and gas bubble fonnation after: a water pressure drop, as well as influ- ence of capillary pressure on these phenomena are described. The effect of the dissolved air on the transient from fully to partially saturated state, during a rapid, gravitational outflow of water from the bottom of a column filled with sand, is numerically analysed.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 53-60
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies