Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model of vibratory unit" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Power Consumption Comparison of Model Vibratory Unit in Power Supply System with and without Inverter for Frequency Setting of 50 Hz
Autorzy:
Ziółkowski, E.
Skrzyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/106929.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
model of vibratory unit
selected energy parameters
Opis:
The article presents the instantaneous voltage and current values recorded in the power-supply system of a vibratory unit directly from the power grid or through an inverter for a frequency setting of 50 Hz. The obtained measurement data was used to perform digital signal processing algorithms, calculations of effective voltages, currents, power (active, reactive, and apparent), and power factor tgφ. The results of the calculations were used to compare the two power systems examined.
Źródło:
Journal of Casting & Materials Engineering; 2017, 1, 2; 53-58
2543-9901
Pojawia się w:
Journal of Casting & Materials Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Selected Energy Parameters in the Supply System of a Model Vibratory Unit
Autorzy:
Ziółkowski, E.
Skrzyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/380714.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
model of vibratory unit
selected energy parameters
active power consumption
apparent power consumption
model jednostki wibracyjnej
wybrane parametry energii
zużycie energii
pobór mocy
Opis:
The article presents the results of selected energy parameters calculations, carried out for the recorded values of instantaneous voltages and currents in the three-phase power supply of the model vibratory unit. The parameters were the values of active and apparent power taken from the drive consisting of two electric motors supplied by the inverter for selected frequency settings and directly from the power grid. In addition, calculations of tgφ power factor values were made to evaluate the compensation of reactive power consumption in the tested power systems. Measurements and calculations lead to the conclusion that if the frequency of the inverter output voltage rises, the active and apparent power consumed by the model vibratory drive unit increases. The active and apparent power for setting the output frequency of the inverter from 50 Hz was less than the active and apparent power taken by the model vibratory unit that was powered directly from the power grid. The power factor tgφ in the power supply system was approximately 6, except one case (f = 30 Hz).
Źródło:
Archives of Foundry Engineering; 2018, 18, 1; 145-150
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies